Anton Volniansky
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Anton Volniansky has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- An Tang
Department of Radiology, Centre Hospitalier de l’Université de Montréal (CHUM), Montreal, Canada
4 shared publications Emmanuel Montagnon
Centre de Recherche du Centre Hospitalier de l'Université de Montréal (CRCHUM) Montréal Canada
4 shared publications- Guillaume Gilbert
Department of Radiology, Radiation Oncology and Nuclear Medicine Université de Montréal Montréal Canada
4 shared publications Guy Cloutier
Department of Radiology, Radiation Oncology and Nuclear Medicine Université de Montréal Montréal Canada
3 shared publicationsJeanne-Marie Giard
Department of Hepatology and Liver Transplantation, Centre Hospitalier de l’Université de Montréal (CHUM), Montréal, QC H2X 0C1
3 shared publications- Marie-Pierre Sylvestre
Department of Social and Preventive Medicine Université de Montréal Montreal Quebec Canada
3 shared publications
Latest Publications
- Open Access
- 28 November 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 63 (4) , 996-1008
Prospective Comparison of DWI ‐Derived Virtual MR Elastography and Conventional MR Elastography in Metabolic Dysfunction‐Associated Steatotic Liver Disease and Healthy Volunteers
Background: Virtual MR elastography (VMRE) and MRE have been proposed for liver fibrosis staging in metabolic dysfunction‐associated steatotic liver disease (MASLD), but VMRE's diagnostic performance remains debated. Purpose: To assess the inter‐visit and inter‐reader reproducibility of fat‐uncorrected and fat‐corrected diffusion‐weighted imaging (DWI)‐based VMRE and to compare their diagnostic performance with MRE for liver fibrosis staging in the MASLD population. Study Type: Prospective. Population: Fifty four participants were enrolled: 43 with biopsy‐proven MASLD (age: 57.0 ± 9.0 years; 26 males) and 11 healthy volunteers (age: 31.0 ± 15.0 years; 4 males). Field Strength/Sequence: 3.0T, DWI ( b ‐values of 0, 200, and 1500 s/mm 2 ) for VMRE and phase‐contrast MRE at 60 Hz was performed. Assessment: VMRE‐derived shifted apparent diffusion coefficients (sADC) reproducibility and diagnostic performance; MRE‐derived stiffness diagnostic performance. Statistical Tests: Reproducibility was evaluated using intraclass correlation coefficients (ICC), within‐subject coefficient of variation (wCV), and bias and limits of agreement (LOA) in Bland–Altman analysis. Diagnostic performance was assessed with areas under the receiver operating characteristic curve (AUC) and compared with DeLong's test. p < 0.05 was considered statistically significant. Results: For inter‐visit agreement, the ICC of fat‐uncorrected and fat‐corrected sADC were 0.88 and 0.83; wCV were 0.120 ± 0.30 and 0.141 ± 0.31; bias and 95% LOA were (−0.03 ± 0.18) × 10 −3 mm 2 /s and (−0.05 ± 0.33) × 10 −3 mm 2 /s, respectively. For inter‐reader agreement, the ICC of fat‐uncorrected and fat‐corrected VMRE were 0.99 and 0.99; wCV were 0.028 ± 0.011 and 0.039 ± 0.012, respectively; bias and 95% LOA were (−0.01 ± 0.03) × 10 −3 mm 2 /s and (−0.02 ± 0.05) × 10 −3 mm 2 /s, respectively. AUC of fat‐uncorrected, fat‐corrected sADC, and MRE‐derived stiffness for distinguishing fibrosis stages F0 versus ≥ F1 were 0.70 ± 0.17, 0.56 ± 0.18, and 0.87 ± 0.10; ≤ F1 versus ≥ F2 were 0.61 ± 0.16, 0.49 ± 0.17, and 0.86 ± 0.10; ≤ F2 versus ≥ F3 were 0.54 ± 0.16, 0.50 ± 0.16, and 0.89 ± 0.09; and ≤ F3 versus F4 were 0.58 ± 0.16, 0.55 ± 0.17, and 0.85 ± 0.11, respectively. MRE had significantly higher diagnostic performance than fat‐uncorrected and fat‐corrected VMRE for all fibrosis stages. Data Conclusion: VMRE has good reproducibility, but has lower fibrosis staging accuracy than MRE. Evidence Level: 1. Technical Efficacy: Stage 2.
- 28 November 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 63 (4) , 996-1008
Open AccessProspective Comparison of DWI ‐Derived Virtual MR Elastography and Conventional MR Elastography in Metabolic Dysfunction‐Associated Steatotic Liver Disease and Healthy Volunteers
Background: Virtual MR elastography (VMRE) and MRE have been proposed for liver fibrosis staging in metabolic dysfunction‐associated steatotic liver disease (MASLD), but VMRE's diagnostic performance remains debated. Purpose: To assess the inter‐visit and inter‐reader reproducibility of fat‐uncorrected and fat‐corrected diffusion‐weighted imaging (DWI)‐based VMRE and to compare their diagnostic performance with MRE for liver fibrosis staging in the MASLD population. Study Type: Prospective. Population: Fifty four participants were enrolled: 43 with biopsy‐proven MASLD (age: 57.0 ± 9.0 years; 26 males) and 11 healthy volunteers (age: 31.0 ± 15.0 years; 4 males). Field Strength/Sequence: 3.0T, DWI ( b ‐values of 0, 200, and 1500 s/mm 2 ) for VMRE and phase‐contrast MRE at 60 Hz was performed. Assessment: VMRE‐derived shifted apparent diffusion coefficients (sADC) reproducibility and diagnostic performance; MRE‐derived stiffness diagnostic performance. Statistical Tests: Reproducibility was evaluated using intraclass correlation coefficients (ICC), within‐subject coefficient of variation (wCV), and bias and limits of agreement (LOA) in Bland–Altman analysis. Diagnostic performance was assessed with areas under the receiver operating characteristic curve (AUC) and compared with DeLong's test. p < 0.05 was considered statistically significant. Results: For inter‐visit agreement, the ICC of fat‐uncorrected and fat‐corrected sADC were 0.88 and 0.83; wCV were 0.120 ± 0.30 and 0.141 ± 0.31; bias and 95% LOA were (−0.03 ± 0.18) × 10 −3 mm 2 /s and (−0.05 ± 0.33) × 10 −3 mm 2 /s, respectively. For inter‐reader agreement, the ICC of fat‐uncorrected and fat‐corrected VMRE were 0.99 and 0.99; wCV were 0.028 ± 0.011 and 0.039 ± 0.012, respectively; bias and 95% LOA were (−0.01 ± 0.03) × 10 −3 mm 2 /s and (−0.02 ± 0.05) × 10 −3 mm 2 /s, respectively. AUC of fat‐uncorrected, fat‐corrected sADC, and MRE‐derived stiffness for distinguishing fibrosis stages F0 versus ≥ F1 were 0.70 ± 0.17, 0.56 ± 0.18, and 0.87 ± 0.10; ≤ F1 versus ≥ F2 were 0.61 ± 0.16, 0.49 ± 0.17, and 0.86 ± 0.10; ≤ F2 versus ≥ F3 were 0.54 ± 0.16, 0.50 ± 0.16, and 0.89 ± 0.09; and ≤ F3 versus F4 were 0.58 ± 0.16, 0.55 ± 0.17, and 0.85 ± 0.11, respectively. MRE had significantly higher diagnostic performance than fat‐uncorrected and fat‐corrected VMRE for all fibrosis stages. Data Conclusion: VMRE has good reproducibility, but has lower fibrosis staging accuracy than MRE. Evidence Level: 1. Technical Efficacy: Stage 2.
- Open Access
- 17 November 2025
- Published by Elsevier in Canadian Journal of Ophthalmology
- Vol. 61 (2) , 280-292
Canadian ophthalmology workforce trends from 1971 to 2022: longitudinal analysis of age, sex, and distribution compared to other surgical specialties
- 17 November 2025
- Published by Elsevier in Canadian Journal of Ophthalmology
- Vol. 61 (2) , 280-292
Open AccessCanadian ophthalmology workforce trends from 1971 to 2022: longitudinal analysis of age, sex, and distribution compared to other surgical specialties
- Open Access
- 10 November 2025
- Published by Oxford University Press (OUP) in Radiology Advances
- Vol. 2 (6) , umaf038
Multifrequency MR elastography for grading inflammation in metabolic dysfunction-associated steatotic liver disease: a pilot study
Background: Noninvasive grading of liver inflammation in metabolic dysfunction-associated steatotic liver disease (MASLD) remains an unmet clinical need. Purpose: To evaluate the diagnostic performance of multifrequency MR elastography (MMRE) for grading liver inflammation and diagnosing metabolic dysfunction-associated steatohepatitis (MASH). Materials and methods: In this prospective, single-site study, participants underwent MMRE at 30, 40, and 60 Hz on a 3T system. Multifrequency dispersion coefficient (α), storage modulus (G'), loss modulus (G”), and magnitude of the shear modulus (|G*|) were computed. The reference standard was histopathological analysis of needle biopsy specimens. The MASLD activity score was computed to assign MASH status. Univariate and multivariable correlation and areas under the receiver operating characteristic curve (AUCs) were assessed. Results: Of the 72 participants enrolled, 60 (12 healthy, 48 MASLD) were analyzable. Correlations of α, G', G”, and |G*| with lobular inflammation grades were ρ = −0.62, P < .001; ρ = 0.46, P < .001; ρ = 0.39, P < .01; and ρ = 0.44, P < .001; and the corresponding correlations with ballooning ρ = −0.42, P < .001; ρ = 0.42, P < .001; ρ = 0.40, P < .001; and ρ = 0.41, P < .001. The correlation between α and lobular inflammation remained after adjusting for steatosis, ballooning, and fibrosis (β = −0.06, P < .001); and with ballooning after adjusting for steatosis, lobular inflammation, and fibrosis (β = −0.02, P < .01). AUCs of α were 0.85, 0.96, and 0.94, respectively, for distinguishing lobular inflammation grades 0 vs ≥1, ≤1 vs ≥2, and ≤2 vs 3; 0.84 and 0.78 for distinguishing ballooning grades 0 vs ≥1 and ≤1 vs 2; and 0.81 to 0.85 for diagnosing MASH. Conclusion: The multifrequency dispersion coefficient α was associated with histologic inflammation and should be further evaluated with external validation as a possible clinical marker in MASLD.
- 10 November 2025
- Published by Oxford University Press (OUP) in Radiology Advances
- Vol. 2 (6) , umaf038
Open AccessMultifrequency MR elastography for grading inflammation in metabolic dysfunction-associated steatotic liver disease: a pilot study
Background: Noninvasive grading of liver inflammation in metabolic dysfunction-associated steatotic liver disease (MASLD) remains an unmet clinical need. Purpose: To evaluate the diagnostic performance of multifrequency MR elastography (MMRE) for grading liver inflammation and diagnosing metabolic dysfunction-associated steatohepatitis (MASH). Materials and methods: In this prospective, single-site study, participants underwent MMRE at 30, 40, and 60 Hz on a 3T system. Multifrequency dispersion coefficient (α), storage modulus (G'), loss modulus (G”), and magnitude of the shear modulus (|G*|) were computed. The reference standard was histopathological analysis of needle biopsy specimens. The MASLD activity score was computed to assign MASH status. Univariate and multivariable correlation and areas under the receiver operating characteristic curve (AUCs) were assessed. Results: Of the 72 participants enrolled, 60 (12 healthy, 48 MASLD) were analyzable. Correlations of α, G', G”, and |G*| with lobular inflammation grades were ρ = −0.62, P < .001; ρ = 0.46, P < .001; ρ = 0.39, P < .01; and ρ = 0.44, P < .001; and the corresponding correlations with ballooning ρ = −0.42, P < .001; ρ = 0.42, P < .001; ρ = 0.40, P < .001; and ρ = 0.41, P < .001. The correlation between α and lobular inflammation remained after adjusting for steatosis, ballooning, and fibrosis (β = −0.06, P < .001); and with ballooning after adjusting for steatosis, lobular inflammation, and fibrosis (β = −0.02, P < .01). AUCs of α were 0.85, 0.96, and 0.94, respectively, for distinguishing lobular inflammation grades 0 vs ≥1, ≤1 vs ≥2, and ≤2 vs 3; 0.84 and 0.78 for distinguishing ballooning grades 0 vs ≥1 and ≤1 vs 2; and 0.81 to 0.85 for diagnosing MASH. Conclusion: The multifrequency dispersion coefficient α was associated with histologic inflammation and should be further evaluated with external validation as a possible clinical marker in MASLD.
- Open Access
- 13 October 2025
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 98 (1176) , 2066-2071
Harnessing intrinsic cardiac motion vs. external mechanical vibrations: a comparison of MRI cine-tagging and MR elastography for liver fibrosis assessment
Objective: This study aims to assess and compare the diagnostic accuracy of MRI cine-tagging and magnetic resonance elastography (MRE) for staging histologically confirmed liver fibrosis in patients with chronic liver disease. Methods: MRI cine-tagging evaluates liver strain as the deformation induced by intrinsic cardiac motion on the left liver lobe, whereas MRE captures liver stiffness in response to externally applied vibrations from a mechanical driver. A head-to-head comparison of MRI cine-tagging and MRE was performed in 76 participants with biopsy-proven chronic liver disease. Spearman’s rank correlation coefficients and areas under the receiver operating characteristic curve (AUC) were assessed. AUCs were compared using the Delong method. Results: MRE-derived shear modulus increased, while strain obtained from tagged cine MRI decreased with higher fibrosis stages (ρ = 0.73 and ρ = −0.67, respectively; P < .0001). Both shear modulus and strain values exhibited significant differences across fibrosis stages (P < .0001) and correlated with each other (ρ = −0.44, P < .0001). MRE provided higher AUCs than MRI cine-tagging only for distinguishing stages ≤F3 vs. F4 (0.91 vs. 0.87, P = .043). There were no significant differences in AUCs for differentiating other dichotomized fibrosis stages, including stages F0 vs. ≥F1 (0.87 vs. 0.81, P = .083), ≤F1 vs. ≥F2 (0.84 vs. 0.84, P = .889), and ≤F2 vs. ≥F3 (0.89 vs. 0.86, P = .116). Conclusion: MRI cine-tagging provided a similar diagnostic performance compared to MRE for staging liver fibrosis, except for the diagnosis of cirrhosis (F4). It is possible to assess liver strain as part of abdominal MRI screening, offering additional insight into the left lobe without the need for additional equipment. Advances in knowledge: A head-to-head comparison of magnetic resonance elastography (MRE), the most accurate technique for the noninvasive staging of liver fibrosis, and MRI cine-tagging has not been performed yet. We found that MRI cine-tagging, having the advantage of not requiring any additional hardware, provides a similar diagnostic performance compared to MRE for staging liver fibrosis, except for the diagnosis of cirrhosis in patients with chronic liver disease.
- 13 October 2025
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 98 (1176) , 2066-2071
Open AccessHarnessing intrinsic cardiac motion vs. external mechanical vibrations: a comparison of MRI cine-tagging and MR elastography for liver fibrosis assessment
Objective: This study aims to assess and compare the diagnostic accuracy of MRI cine-tagging and magnetic resonance elastography (MRE) for staging histologically confirmed liver fibrosis in patients with chronic liver disease. Methods: MRI cine-tagging evaluates liver strain as the deformation induced by intrinsic cardiac motion on the left liver lobe, whereas MRE captures liver stiffness in response to externally applied vibrations from a mechanical driver. A head-to-head comparison of MRI cine-tagging and MRE was performed in 76 participants with biopsy-proven chronic liver disease. Spearman’s rank correlation coefficients and areas under the receiver operating characteristic curve (AUC) were assessed. AUCs were compared using the Delong method. Results: MRE-derived shear modulus increased, while strain obtained from tagged cine MRI decreased with higher fibrosis stages (ρ = 0.73 and ρ = −0.67, respectively; P < .0001). Both shear modulus and strain values exhibited significant differences across fibrosis stages (P < .0001) and correlated with each other (ρ = −0.44, P < .0001). MRE provided higher AUCs than MRI cine-tagging only for distinguishing stages ≤F3 vs. F4 (0.91 vs. 0.87, P = .043). There were no significant differences in AUCs for differentiating other dichotomized fibrosis stages, including stages F0 vs. ≥F1 (0.87 vs. 0.81, P = .083), ≤F1 vs. ≥F2 (0.84 vs. 0.84, P = .889), and ≤F2 vs. ≥F3 (0.89 vs. 0.86, P = .116). Conclusion: MRI cine-tagging provided a similar diagnostic performance compared to MRE for staging liver fibrosis, except for the diagnosis of cirrhosis (F4). It is possible to assess liver strain as part of abdominal MRI screening, offering additional insight into the left lobe without the need for additional equipment. Advances in knowledge: A head-to-head comparison of magnetic resonance elastography (MRE), the most accurate technique for the noninvasive staging of liver fibrosis, and MRI cine-tagging has not been performed yet. We found that MRI cine-tagging, having the advantage of not requiring any additional hardware, provides a similar diagnostic performance compared to MRE for staging liver fibrosis, except for the diagnosis of cirrhosis in patients with chronic liver disease.
- Open Access
- 28 July 2025
- Published by F1000 Research Ltd in MedEdPublish
- Vol. 15, 39
Resource stewardship learning needs in undergraduate medical training: a cross-sectional study
Background No clear guidelines for Canadian medical schools regarding the integration of resource stewardship (RS) in the training of tomorrow’s physicians exist. This study aimed to determine the learning needs of undergraduate medical students on RS in Quebec. Methods An online survey was distributed to all medical students in Quebec from January 12 th to April 27 th , 2021. A cross-sectional study was then performed. In total, 900 medical students (23.2% of all Quebec medical students) were included in this study. Results RS teaching was perceived as being insufficient. Despite 69% of students knowing the existence of Choosing Wisely, only 21.7% considered RS teaching to sufficiently develop their critical thinking. While students claimed that RS's current teaching methods are predominantly theoretical, a preference for more practical learning approaches was noted. Approximately 71% of students undergoing clerkship rotations acknowledged the significance of role models in fostering critical thinking skills related to RS. Heterogeneity was noted across medical schools. Conclusions This study confirms that according to students’ perspective, RS is important yet insufficiently and heterogeneously taught in Quebec. Establishing guidelines regarding RS teaching in medical schools could provide equal learning opportunities. Furthermore, encouraging role models to be part of this teaching effort may also strengthen student’s critical thinking regarding RS.
- 28 July 2025
- Published by F1000 Research Ltd in MedEdPublish
- Vol. 15, 39
Open AccessResource stewardship learning needs in undergraduate medical training: a cross-sectional study
Background No clear guidelines for Canadian medical schools regarding the integration of resource stewardship (RS) in the training of tomorrow’s physicians exist. This study aimed to determine the learning needs of undergraduate medical students on RS in Quebec. Methods An online survey was distributed to all medical students in Quebec from January 12 th to April 27 th , 2021. A cross-sectional study was then performed. In total, 900 medical students (23.2% of all Quebec medical students) were included in this study. Results RS teaching was perceived as being insufficient. Despite 69% of students knowing the existence of Choosing Wisely, only 21.7% considered RS teaching to sufficiently develop their critical thinking. While students claimed that RS's current teaching methods are predominantly theoretical, a preference for more practical learning approaches was noted. Approximately 71% of students undergoing clerkship rotations acknowledged the significance of role models in fostering critical thinking skills related to RS. Heterogeneity was noted across medical schools. Conclusions This study confirms that according to students’ perspective, RS is important yet insufficiently and heterogeneously taught in Quebec. Establishing guidelines regarding RS teaching in medical schools could provide equal learning opportunities. Furthermore, encouraging role models to be part of this teaching effort may also strengthen student’s critical thinking regarding RS.
- Open Access
- 24 January 2025
- Published by MDPI AG in Biomedicines
- Vol. 13 (2) , 284
A Future Picture: A Review of Current Generative Adversarial Neural Networks in Vitreoretinal Pathologies and Their Future Potentials
Machine learning has transformed ophthalmology, particularly in predictive and discriminatory models for vitreoretinal pathologies. However, generative modeling, especially generative adversarial networks (GANs), remains underexplored. GANs consist of two neural networks—the generator and discriminator—that work in opposition to synthesize highly realistic images. These synthetic images can enhance diagnostic accuracy, expand the capabilities of imaging technologies, and predict treatment responses. GANs have already been applied to fundus imaging, optical coherence tomography (OCT), and fluorescein autofluorescence (FA). Despite their potential, GANs face challenges in reliability and accuracy. This review explores GAN architecture, their advantages over other deep learning models, and their clinical applications in retinal disease diagnosis and treatment monitoring. Furthermore, we discuss the limitations of current GAN models and propose novel applications combining GANs with OCT, OCT-angiography, fluorescein angiography, fundus imaging, electroretinograms, visual fields, and indocyanine green angiography.
- 24 January 2025
- Published by MDPI AG in Biomedicines
- Vol. 13 (2) , 284
Open AccessA Future Picture: A Review of Current Generative Adversarial Neural Networks in Vitreoretinal Pathologies and Their Future Potentials
Machine learning has transformed ophthalmology, particularly in predictive and discriminatory models for vitreoretinal pathologies. However, generative modeling, especially generative adversarial networks (GANs), remains underexplored. GANs consist of two neural networks—the generator and discriminator—that work in opposition to synthesize highly realistic images. These synthetic images can enhance diagnostic accuracy, expand the capabilities of imaging technologies, and predict treatment responses. GANs have already been applied to fundus imaging, optical coherence tomography (OCT), and fluorescein autofluorescence (FA). Despite their potential, GANs face challenges in reliability and accuracy. This review explores GAN architecture, their advantages over other deep learning models, and their clinical applications in retinal disease diagnosis and treatment monitoring. Furthermore, we discuss the limitations of current GAN models and propose novel applications combining GANs with OCT, OCT-angiography, fluorescein angiography, fundus imaging, electroretinograms, visual fields, and indocyanine green angiography.
- Open Access
- 24 October 2024
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 61 (6) , 2525-2540
MR Elastography for Classification of Focal Liver Lesions Using Viscoelastic Parameters: A Pilot Study Based on Intrinsic and Extrinsic Activations
Background: Intrinsic activation MR elastography (iMRE) uses cardiovascular pulsations to assess tissue viscoelastic properties. Applying it to focal liver lesions extends its capabilities.Purpose: To assess the viscoelastic parameters of focal liver lesions measured by iMRE and compare its diagnostic performance with extrinsic MRE (eMRE) for differentiating malignant and benign lesions.Study type: Prospective.Population: A total of 55 participants underwent MRI with research MRE sequences; 32 participants with 17 malignant and 15 benign lesions underwent both iMRE and eMRE.Field Strength/Sequence: iMRE at ~1 Hz heart rate used a 3 T scanner with a modified four‐dimensional (4D)‐quantitative flow gradient‐echo phase contrast and low‐velocity encoding cardiac‐triggered technique. eMRE employed a gradient‐echo sequence at 30, 40, and 60 Hz.Assessment: Liver displacements were measured using 4D‐phase contrast and reconstructed via a nonlinear inversion algorithm to determine shear stiffness (SS) and damping ratio (DR). iMRE parameters were normalized to the corresponding values from the spleen. Lesions were manually segmented, and image quality was reviewed.Statistical Tests: Kruskal–Wallis, Mann–Whitney, Dunn's test, and areas under receiver operating characteristic curves (AUC) were assessed.Results: SS was significantly higher in malignant than benign lesions with iMRE at 1 Hz (3.69 ± 1.31 vs. 1.63 ± 0.45) and eMRE at 30 Hz (3.76 ± 1.12 vs. 2.60 ± 1.26 kPa), 40 Hz (3.76 ± 1.12 vs. 2.60 ± 1.26 kPa), and 60 Hz (7.32 ± 2.87 vs. 2.48 ± 1.12 kPa). DR was also significantly higher in malignant than benign lesions at 40 Hz (0.36 ± 0.11 vs. 0.21 ± 0.01) and 60 Hz (0.89 ± 0.86 vs. 0.22 ± 0.09). The AUC were 0.86 for iMRE SS, 0.87–0.98 for eMRE SS, 0.47 for iMRE DR, and 0.62–0.86 for eMRE DR.Data Conclusion: Cardiac‐activated iMRE can characterize liver lesions and differentiate malignant from benign lesions through normalized SS maps.Level of Evidence: 2Technical Efficacy: Stage 2
- 24 October 2024
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 61 (6) , 2525-2540
Open AccessMR Elastography for Classification of Focal Liver Lesions Using Viscoelastic Parameters: A Pilot Study Based on Intrinsic and Extrinsic Activations
Background: Intrinsic activation MR elastography (iMRE) uses cardiovascular pulsations to assess tissue viscoelastic properties. Applying it to focal liver lesions extends its capabilities.Purpose: To assess the viscoelastic parameters of focal liver lesions measured by iMRE and compare its diagnostic performance with extrinsic MRE (eMRE) for differentiating malignant and benign lesions.Study type: Prospective.Population: A total of 55 participants underwent MRI with research MRE sequences; 32 participants with 17 malignant and 15 benign lesions underwent both iMRE and eMRE.Field Strength/Sequence: iMRE at ~1 Hz heart rate used a 3 T scanner with a modified four‐dimensional (4D)‐quantitative flow gradient‐echo phase contrast and low‐velocity encoding cardiac‐triggered technique. eMRE employed a gradient‐echo sequence at 30, 40, and 60 Hz.Assessment: Liver displacements were measured using 4D‐phase contrast and reconstructed via a nonlinear inversion algorithm to determine shear stiffness (SS) and damping ratio (DR). iMRE parameters were normalized to the corresponding values from the spleen. Lesions were manually segmented, and image quality was reviewed.Statistical Tests: Kruskal–Wallis, Mann–Whitney, Dunn's test, and areas under receiver operating characteristic curves (AUC) were assessed.Results: SS was significantly higher in malignant than benign lesions with iMRE at 1 Hz (3.69 ± 1.31 vs. 1.63 ± 0.45) and eMRE at 30 Hz (3.76 ± 1.12 vs. 2.60 ± 1.26 kPa), 40 Hz (3.76 ± 1.12 vs. 2.60 ± 1.26 kPa), and 60 Hz (7.32 ± 2.87 vs. 2.48 ± 1.12 kPa). DR was also significantly higher in malignant than benign lesions at 40 Hz (0.36 ± 0.11 vs. 0.21 ± 0.01) and 60 Hz (0.89 ± 0.86 vs. 0.22 ± 0.09). The AUC were 0.86 for iMRE SS, 0.87–0.98 for eMRE SS, 0.47 for iMRE DR, and 0.62–0.86 for eMRE DR.Data Conclusion: Cardiac‐activated iMRE can characterize liver lesions and differentiate malignant from benign lesions through normalized SS maps.Level of Evidence: 2Technical Efficacy: Stage 2
- Open Access
- 23 August 2024
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 113, 110223
Inter-visit and inter-reader reproducibility of multi-parametric diffusion-weighted MR imaging in longitudinally imaged patients with metabolic dysfunction-associated fatty liver disease and healthy volunteers.
- 23 August 2024
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 113, 110223
Open AccessInter-visit and inter-reader reproducibility of multi-parametric diffusion-weighted MR imaging in longitudinally imaged patients with metabolic dysfunction-associated fatty liver disease and healthy volunteers.