Prospective Comparison of DWI ‐Derived Virtual MR Elastography and Conventional MR Elastography in Metabolic Dysfunction‐Associated Steatotic Liver Disease and Healthy Volunteers
Open Access
- 28 November 2025
- journal article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 63 (4) , 996-1008
Abstract
Background: Virtual MR elastography (VMRE) and MRE have been proposed for liver fibrosis staging in metabolic dysfunction‐associated steatotic liver disease (MASLD), but VMRE's diagnostic performance remains debated. Purpose: To assess the inter‐visit and inter‐reader reproducibility of fat‐uncorrected and fat‐corrected diffusion‐weighted imaging (DWI)‐based VMRE and to compare their diagnostic performance with MRE for liver fibrosis staging in the MASLD population. Study Type: Prospective. Population: Fifty four participants were enrolled: 43 with biopsy‐proven MASLD (age: 57.0 ± 9.0 years; 26 males) and 11 healthy volunteers (age: 31.0 ± 15.0 years; 4 males). Field Strength/Sequence: 3.0T, DWI ( b ‐values of 0, 200, and 1500 s/mm 2 ) for VMRE and phase‐contrast MRE at 60 Hz was performed. Assessment: VMRE‐derived shifted apparent diffusion coefficients (sADC) reproducibility and diagnostic performance; MRE‐derived stiffness diagnostic performance. Statistical Tests: Reproducibility was evaluated using intraclass correlation coefficients (ICC), within‐subject coefficient of variation (wCV), and bias and limits of agreement (LOA) in Bland–Altman analysis. Diagnostic performance was assessed with areas under the receiver operating characteristic curve (AUC) and compared with DeLong's test. p < 0.05 was considered statistically significant. Results: For inter‐visit agreement, the ICC of fat‐uncorrected and fat‐corrected sADC were 0.88 and 0.83; wCV were 0.120 ± 0.30 and 0.141 ± 0.31; bias and 95% LOA were (−0.03 ± 0.18) × 10 −3 mm 2 /s and (−0.05 ± 0.33) × 10 −3 mm 2 /s, respectively. For inter‐reader agreement, the ICC of fat‐uncorrected and fat‐corrected VMRE were 0.99 and 0.99; wCV were 0.028 ± 0.011 and 0.039 ± 0.012, respectively; bias and 95% LOA were (−0.01 ± 0.03) × 10 −3 mm 2 /s and (−0.02 ± 0.05) × 10 −3 mm 2 /s, respectively. AUC of fat‐uncorrected, fat‐corrected sADC, and MRE‐derived stiffness for distinguishing fibrosis stages F0 versus ≥ F1 were 0.70 ± 0.17, 0.56 ± 0.18, and 0.87 ± 0.10; ≤ F1 versus ≥ F2 were 0.61 ± 0.16, 0.49 ± 0.17, and 0.86 ± 0.10; ≤ F2 versus ≥ F3 were 0.54 ± 0.16, 0.50 ± 0.16, and 0.89 ± 0.09; and ≤ F3 versus F4 were 0.58 ± 0.16, 0.55 ± 0.17, and 0.85 ± 0.11, respectively. MRE had significantly higher diagnostic performance than fat‐uncorrected and fat‐corrected VMRE for all fibrosis stages. Data Conclusion: VMRE has good reproducibility, but has lower fibrosis staging accuracy than MRE. Evidence Level: 1. Technical Efficacy: Stage 2.Keywords
Funding Information
- Fondation de l'Association des radiologistes du Québec (FRQS‐FARQ #298509)
- Canadian Institutes of Health Research (CIHR‐INMD #389385)
This publication has 33 references indexed in Scilit:
- Assessing liver fibrosis in chronic liver disease: Comparison of diffusion-weighted MR elastography and two-dimensional shear-wave elastography using histopathologic assessment as the reference standardAnnals of Hepatology, 2024
- Virtual MR Elastography and Multi-b-value DWI Models for Predicting Microvascular Invasion in Solitary BCLC Stage A Hepatocellular CarcinomaAcademic Radiology, 2024
- Simultaneous whole‐liver water T1 and T2 mapping with isotropic resolution during free‐breathingNMR in Biomedicine, 2024
- Diffusion‐Based Virtual MR Elastography in Subjects With Nonalcoholic Fatty Liver DiseaseJournal of Magnetic Resonance Imaging, 2022
- Prospective Evaluation of Virtual MR Elastography With Diffusion‐Weighted Imaging in Subjects With Nonalcoholic Fatty Liver DiseaseJournal of Magnetic Resonance Imaging, 2022
- B0 and B1 inhomogeneities in the liver at 1.5 T and 3.0 TMagnetic Resonance in Medicine, 2020
- Diagnostic Performance of Magnetic Resonance Elastography in Staging Liver Fibrosis: A Systematic Review and Meta-analysis of Individual Participant DataClinical Gastroenterology and Hepatology, 2015
- Magnetic resonance elastography of liver: Technique, analysis, and clinical applicationsJournal of Magnetic Resonance Imaging, 2013
- In vivo characterization of the liver fat 1H MR spectrumNMR in Biomedicine, 2010
- Index for rating diagnostic testsCancer, 1950