PWPeter Wobrauschek

Peter Wobrauschek

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Peter Wobrauschek has a total of 67 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Elemental Mapping of Historical Daguerreotypes Using Monochromatic Micro‐ XRF : Imaging, Degradation, and Conservation Potential

    by Valentina Ljubić Tobisch, Dieter Ingerle, Peter Wobrauschek, Christina Streli, Andreas Steiger‐Thirsfeld, Karin Whitmore, Wolfgang Kautek, Klaudia Hradil

    The daguerreotype, introduced by Louis‐Jacques‐Mandé Daguerre in 1839, marked the beginning of photography. This early photographic process, based on halide‐sensitized silver‐coated copper plates developed with mercury vapor, produces highly reflective, image‐bearing surfaces that are both visually unique and chemically complex. As part of the interdisciplinary Heritage Science project PHELETYPIA, this study investigates the surface morphology and elemental composition of two historical daguerreotypes from the Varaždin City Museum (Croatia) using monochromatic micro‐x‐ray fluorescence (μXRF), scanning electron microscopy with energy‐dispersive x‐ray spectrometry (SEM/EDS), and optical microscopy. By comparing elemental distribution maps based on Hg‐L and Au‐L lines, we assess the relationship between image particle composition, visual contrast, and degradation patterns. Our results suggest that differences in image formation and preservation are linked to original manufacturing processes, including uneven thermal development and subsequent environmental exposure. High‐resolution elemental imaging reveals how visual information is distributed across tonal zones and how it may be affected by previous conservation interventions. These findings highlight the potential of non‐invasive analytical imaging to enhance our understanding of daguerreotype image structure, support condition assessment, and inform long‐term digital preservation strategies.

  • Open Access

    A new compact micro‐XRF spectrometer with polychromatic x‐ray sample excitation

    by Peter Wobrauschek, Dieter Ingerle, Josef Prost, Sangita Dhara, Nand Lal Mishra, Michael Iro, Christina Streli

    A new compact micro‐x‐ray fluorescence (μ‐XRF) spectrometer covering wide range of elements was developed and fabricated. The working capabilities of this new compact custom‐made μ‐XRF spectrometer are presented. The spectrometer uses a low power Rh target x‐ray tube for sample excitation. Polycapillary optics focuses the polychromatic beam down to 40 μm. The emitted radiation is measured by a peltier cooled silicon drift detector of 30 mm 2 crystal size. It was observed that the polychromatic excitation provides sufficient photons for an efficient excitation of the sample to achieve good detection limit and area resolution. The detection limits are comparable with that one obtained by TXRF for a thin film sample. The advantage of the present setup, is the fact that it is suitable for specific applications for example, for radioactive and toxic samples requiring instrument adoption in glove boxes or fume hoods because of its good analytical features accompanied by simple and compact instrumentation.


  • Open Access

    Correlation of μXRF and LA-ICP-MS in the analysis of a human bone-cartilage sample

    by Anna Turyanskaya, Stefan Smetaczek, Vanessa Pichler, Mirjam Rauwolf, Lukas Perneczky, Andreas Roschger, Paul Roschger, Peter Wobrauschek, Andreas Limbeck, Christina Streli

    In this study we combined μXRF and LA-ICP-MS on the very same human femoral head sample. Obtained spatial elemental distributions within bone and cartilage tissues are accompanied by absolute quantitative data.


  • A monochromatic confocal micro-x-ray fluorescence (μXRF) spectrometer for the lab

    by D. Ingerle, J. Swies, M. Iro, P. Wobrauschek, C. Streli, K. Hradil

    Confocal micro-x-ray fluorescence (μXRF) is a powerful tool to analyze the spatial distribution of major, minor, and trace elements in three dimensions. Typical (confocal) μXRF measurements in the lab use polychromatic excitation, complicating quantification and fundamental parameter-based corrections and furthermore deteriorating peak-to-background ratios due to scattered bremsstrahlung. The goal for the new setup was to remedy these problems, without sacrificing spatial resolution, and keep it flexible for different excitation energies and transportation to other sources. The source assembly consists of a water-cooled fine-focus x-ray diffraction tube and a parallel beam-mirror, which produces a quasi-parallel, monochromatic beam. The presented results were obtained using a 2 kW molybdenum tube and a mirror for Mo-Kα. The confocal setup itself consists of two polycapillary half-lenses, one for the source side and the other for the detector side, where a 50 mm2 silicon drift detector is mounted. Both polycapillaries have a focus size of ∼15 μm for Mo-Kα. The second polycapillary can also be exchanged for a custom-designed collimator in order to perform non-confocal μXRF. Details of the technical setup and results from technical and biological samples are presented. Detection limits for selected elements from Ca to Pb in the confocal and non-confocal mode were established (e.g., 1 μg/g non-confocal and 20 μg/g confocal for As) using the NIST standard reference materials (SRMs) 621 and 1412. Furthermore, the results of the measurements of SRM 621 were evaluated using the fundamental parameter based quantification software ATI-QUANT. The results are compared with the certified values and generally are in good agreement.


  • Measurement of the Th229 Isomer Energy with a Magnetic Microcalorimeter

    by Tomas Sikorsky, Jeschua Geist, Daniel Hengstler, Sebastian Kempf, Loredana Gastaldo, Christian Enss, Christoph Mokry, Jörg Runke, Christoph E. Düllmann, Peter Wobrauschek, et al.

    We present a measurement of the low-energy (0–60 keV) γ-ray spectrum produced in the α decay of U233 using a dedicated cryogenic magnetic microcalorimeter. The energy resolution of ∼10  eV, together with exceptional gain linearity, allows us to determine the energy of the low-lying isomeric state in Th229 using four complementary evaluation schemes. The most precise scheme determines the Th229 isomer energy to be 8.10(17) eV, corresponding to 153.1(32) nm, superseding in precision previous values based on γ spectroscopy, and agreeing with a recent measurement based on internal conversion electrons. We also measure branching ratios of the relevant excited states to be b29=9.3(6)% and b42<0.7%.


  • Open Access

    Total reflection X‐ray fluorescence analysis of elemental composition of herbal infusions and teas

    by Aleksandra Winkler, Mirjam Rauwolf, Johannes H. Sterba, Peter Wobrauschek, Christina Streli, Anna Turyanskaya

    BACKGROUND: The elemental composition of herbal infusions and teas has not been sufficiently investigated. It could potentially be used for defining fingerprints for individual herbal / tea infusions, differentiation of botanical families, detecting the influence of packaging, and other purposes. The objective of this study was to determine the elemental composition, including the trace element content, of various herbal infusions and teas by means of total reflection X‐ray fluorescence analysis (TXRF), with a chemometrics approach using principal component analysis (PCA).RESULTS: This study determined the elemental composition of various herbal infusions and teas, including trace elements, using total reflection X‐ray fluorescence (TXRF). The methodology for the sample preparation was established, including the multiple‐steepings procedure for the two tea samples (Oolong and Pu‐erh). Data from 29 samples were collected. We hypothesized that the elemental content of infusions could reflect certain features, such as the influence of processing and the type of tea.CONCLUSION: A chemometric approach (PCA) was applied, and differences between teas and herbal infusions were found. This was further corroborated by explicit differentiation of one botanical family, Theaceae. The influence of packaging (tea bags) on herbal material was identified. The three types of tea (Camellia sinensis) appeared to be separated with PCA, and elemental concentrations in Pu‐erh changed with multiple steepings.


  • Dual energy-band excitation from a low power Rh anode X-ray tube for the simultaneous determination of low Z and high Z elements (Na-U) using total-reflection X-ray fluorescence analysis (TXRF)

    by J. Prost, P. Wobrauschek, C. Streli

    This article presents results from an experimental setup for a dual energy-band vacuum spectrometer for total-reflection X-ray fluorescence analysis allowing simultaneous efficient excitation of low, medium, and high Z elements. The spectrometer is equipped with an air-cooled 35 W low power Rh X-ray tube and a 17 mm2 silicon drift detector with a thin 8 µm beryllium window. A Pd/B4C multilayer monochromator is used at the same time as a Bragg reflector for Rh-Kα radiation and as a high-energy cut-off reflector above 5 keV, where the characteristic Rh-L radiation is totally reflected and present in the spectrum of the exciting radiation. This leaves one broad low energy band below 5 keV and one high energy band around the energy of Rh-Kα. As Rh-L radiation would be absorbed on its path through air, a new beam entrance system was designed in order to guide the Rh-L photons into the vacuum chamber for efficient excitation of low Z elements. With this setup, elements down to sodium (Z = 11, E = 1.04 keV) could be detected. First results are presented, and spectra obtained in air as well as in vacuum are compared and discussed. Detection limits in the range of 1000 µg/kg for Na and around 140 µg/kg for Mg were achieved using the NIST SRM 1640 (trace elements in water).


  • Open Access

    Increased zinc accumulation in mineralized osteosarcoma tissue measured by confocal synchrotron radiation micro X‐ray fluorescence analysis

    by Mirjam Rauwolf, Bernhard Pemmer, Andreas Roschger, Anna Turyanskaya, Stephan Smolek, Angelika Maderitsch, Peter Hischenhuber, Martin Foelser, Rolf Simon, Susanna Lang, et al.

    Abnormal tissue levels of certain trace elements such as zinc (Zn) were reported in various types of cancer. Little is known about the role of Zn in osteosarcoma. Using confocal synchrotron radiation micro X‐ray fluorescence analysis, we characterized the spatial distribution of Zn in high‐grade sclerosing osteosarcoma of nine patients (four women/five men; seven knee/one humerus/one femur) following chemotherapy and wide surgical resection. Levels were compared with adjacent normal tissue. Quantitative backscattered electron imaging as well as histological examinations was also performed. On average, the ratio of medians of Zn count rates (normalized to calcium) in mineralized tumor tissue was about six times higher than in normal tissue. There was no difference in Zn levels between tumor fraction areas with a low fraction and a high fraction of mineralized tissue, which were clearly depicted using quantitative backscattered electron imaging. Moreover, we found no correlation between the Zn values and the type of tumor regression according to the Salzer‐Kuntschik grading. The underlying mechanism of Zn accumulation remains unclear. Given the emerging data on the role of trace elements in other types of cancer, our novel results warrant further studies on the role of trace elements in bone cancer. Copyright © 2016 The Authors. X‐Ray Spectrometry published by John Wiley & Sons Ltd.


  • A novel vacuum spectrometer for total reflection x-ray fluorescence analysis with two exchangeable low power x-ray sources for the analysis of low, medium, and high Z elements in sequence

    by P. Wobrauschek, J. Prost, D. Ingerle, P. Kregsamer, N. L. Misra, C. Streli

    The extension of the detectable elemental range with Total Reflection X-ray Fluorescence (TXRF) analysis is a challenging task. In this paper, it is demonstrated how a TXRF spectrometer is modified to analyze elements from carbon to uranium. Based on the existing design of a vacuum TXRF spectrometer with a 12 specimen sample changer, the following components were renewed: the silicon drift detector with 20 mm2 active area and having a special ultra-thin polymer window allowing the detection of elements from carbon upwards. Two exchangeable X-ray sources guarantee the efficient excitation of both low and high Z elements. These X-ray sources were two light-weighted easily mountable 35 W air-cooled low-power tubes with Cr and Rh anodes, respectively. The air cooled tubes and the Peltier-cooled detector allowed to construct a transportable tabletop spectrometer with compact dimensions, as neither liquid nitrogen cooling for the detector nor a water cooling circuit and a bulky high voltage generator for the X-ray tubes are required. Due to the excellent background conditions as a result of the TXRF geometry, detection limits of 150 ng for C, 12 ng for F, and 3.3 ng for Na have been obtained using Cr excitation in vacuum. For Rh excitation, the detection limits of 90 pg could be achieved for Sr. Taking 10 to 20 μl of sample volume, extrapolated detection limits in the ng/g (ppb) range are resulting in terms of concentration.