Zacharias G. Datsios
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zacharias G. Datsios has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Pantelis N. Mikropoulos
High Voltage Laboratory, School of Electrical and Computer Engineering, Aristotle University of Thessaloniki, Thessaloniki, Greece
26 shared publications - Thomas E. Tsovilis
High Voltage Laboratory, School of Electrical & Computer Engineering, Aristotle University of Thessaloniki, Thessaloniki, Greece
18 shared publications - Evangelos Theocharis Staikos
High Voltage Laboratory, School of Electrical and Computer Engineering, Aristotle University of Thessaloniki, Thessaloniki, Greece
5 shared publications - Theofilos A. Papadopoulos
Power Systems Laboratory, School of Electrical and Computer Engineering, Aristotle University of Thessaloniki, Thessaloniki, Greece
4 shared publications - Alexandros Y. Hadjicostas
High Voltage Laboratory, School of Electrical and Computer Engineering, Aristotle University of Thessaloniki, Thessaloniki, Greece
3 shared publications - Andreas. I. Chrysochos
R&D Department of Cablel, Hellenic Cables S.A., Viohalco Group, Sousaki Korinthias, Korinthos Greece
3 shared publications
Latest Publications
- Open Access
- 26 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (6) , 8832-8842
Dimensioning of Sheath Voltage Limiters for Single- Core Power Cables Connecting an Overhead Transmission Line to a 150 kV Substation
This case study evaluates the stresses of sheath voltage limiters installed at the open end of single-point bonding systems employed for two single-core power cable circuits (lengths: 120 m and 50 m). These cable circuits connect one circuit of a 150 kV double-circuit overhead transmission line to a 150/33 kV substation. Detailed simulations are performed using the ATP-EMTP software for four main scenarios: (i) steady-state operating conditions, (ii) single-phase and three-phase short circuits, (iii) lightning strikes to towers, and (iv) shielding failures at the incoming 150 kV overhead line. For the lightning-related scenarios (iii and iv), the residual voltage and the surge current through the sheath voltage limiters are computed, considering the effects of the instantaneous value of the AC operating voltage, the time to half value, and the amplitude of the lightning return-stroke current. Stress on the sheath voltage limiters is analyzed in terms of charge transfer and specific energy obtained through simulations. Finally, the minimum required characteristics of the sheath voltage limiters are determined and discussed in the context of appropriate dimensioning in engineering applications.
- 26 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (6) , 8832-8842
Open AccessDimensioning of Sheath Voltage Limiters for Single- Core Power Cables Connecting an Overhead Transmission Line to a 150 kV Substation
This case study evaluates the stresses of sheath voltage limiters installed at the open end of single-point bonding systems employed for two single-core power cable circuits (lengths: 120 m and 50 m). These cable circuits connect one circuit of a 150 kV double-circuit overhead transmission line to a 150/33 kV substation. Detailed simulations are performed using the ATP-EMTP software for four main scenarios: (i) steady-state operating conditions, (ii) single-phase and three-phase short circuits, (iii) lightning strikes to towers, and (iv) shielding failures at the incoming 150 kV overhead line. For the lightning-related scenarios (iii and iv), the residual voltage and the surge current through the sheath voltage limiters are computed, considering the effects of the instantaneous value of the AC operating voltage, the time to half value, and the amplitude of the lightning return-stroke current. Stress on the sheath voltage limiters is analyzed in terms of charge transfer and specific energy obtained through simulations. Finally, the minimum required characteristics of the sheath voltage limiters are determined and discussed in the context of appropriate dimensioning in engineering applications.
- 5 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-11
Implementation of Leader Development Models for Prediction of Insulation Flashover in Lightning Studies
The prediction of the behavior of long air gaps and insulators, when stressed by fast-front overvoltages of non-standard waveshape, is crucial for evaluating the effects of lightning to power systems. This can be achieved in an accurate manner by applying leader development models (LDMs), accounting for the associated physical processes. This work contributes to LDM application to different methodologies/techniques used for the simulation of lightning strikes to power systems, and hence, for insulation coordination studies. This is achieved by identifying and discussing important features related to LDM implementation in a generalized manner not tied to a specific methodology and a specific LDM. Finite Difference Time Domain (FDTD) and ATP-EMTP implementations are introduced to investigate the effects of these elements. They are then employed to assess the lightning performance of a 150 kV single-circuit overhead power line. For this purpose, the minimum lightning currents causing shielding failure flashover and backflashover to the line are computed by means of the two aforementioned simulation methods. Results are compared and discussed considering the differences between methods. For the shielding failure case, identical results were obtained. Differences from <1% up to ∼10% were found for the minimum backflashover current, and up to <5% for the backflashover rate.
- 5 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-11
Implementation of Leader Development Models for Prediction of Insulation Flashover in Lightning Studies
The prediction of the behavior of long air gaps and insulators, when stressed by fast-front overvoltages of non-standard waveshape, is crucial for evaluating the effects of lightning to power systems. This can be achieved in an accurate manner by applying leader development models (LDMs), accounting for the associated physical processes. This work contributes to LDM application to different methodologies/techniques used for the simulation of lightning strikes to power systems, and hence, for insulation coordination studies. This is achieved by identifying and discussing important features related to LDM implementation in a generalized manner not tied to a specific methodology and a specific LDM. Finite Difference Time Domain (FDTD) and ATP-EMTP implementations are introduced to investigate the effects of these elements. They are then employed to assess the lightning performance of a 150 kV single-circuit overhead power line. For this purpose, the minimum lightning currents causing shielding failure flashover and backflashover to the line are computed by means of the two aforementioned simulation methods. Results are compared and discussed considering the differences between methods. For the shielding failure case, identical results were obtained. Differences from <1% up to ∼10% were found for the minimum backflashover current, and up to <5% for the backflashover rate.
- Open Access
- 3 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (2) , 2324-2335
Surge Protection of Charging Stations Against Impinging Overvoltages Due to Lightning Strikes to Incoming Medium Voltage Overhead Line
A typical 1 MVA charging station for electric cars connected to the overhead distribution system through underground medium voltage cables is modeled in the ATP-EMTP environment. Fast-front overvoltages impinging on the AC and DC sides of charging station equipment due to a wide range of lightning strikes to the incoming overhead medium voltage line are computed; positive and negative recorded lightning stroke currents are also considered. The risk of failure is evaluated by considering the rated impulse withstand voltage level of the charging station equipment by assessing the effects of lightning polarity, peak current, and soil resistivity. A protection scheme involving the installation of surge protective devices is investigated to diminish the risk of failure of equipment and interconnected charging cars. The energy absorption capability of surge protective devices against remote lightning strikes is assessed and the necessity of integrating surge protective devices to electric vehicles offering dedicated surge protection is discussed.
- 3 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (2) , 2324-2335
Open AccessSurge Protection of Charging Stations Against Impinging Overvoltages Due to Lightning Strikes to Incoming Medium Voltage Overhead Line
A typical 1 MVA charging station for electric cars connected to the overhead distribution system through underground medium voltage cables is modeled in the ATP-EMTP environment. Fast-front overvoltages impinging on the AC and DC sides of charging station equipment due to a wide range of lightning strikes to the incoming overhead medium voltage line are computed; positive and negative recorded lightning stroke currents are also considered. The risk of failure is evaluated by considering the rated impulse withstand voltage level of the charging station equipment by assessing the effects of lightning polarity, peak current, and soil resistivity. A protection scheme involving the installation of surge protective devices is investigated to diminish the risk of failure of equipment and interconnected charging cars. The energy absorption capability of surge protective devices against remote lightning strikes is assessed and the necessity of integrating surge protective devices to electric vehicles offering dedicated surge protection is discussed.
- 3 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (6) , 8362-8370
Surge Current Withstand Capability of Natural Ester Oil: A Comparison to Gas-to-Liquid Transformer Oil
The basic electrical characteristics of a natural ester oil are experimentally investigated and compared to gas-to-liquid transformer oil with emphasis given to the endurance against surge events. An accelerated degradation test is conducted using a sequence of current impulses generated through a combination wave generator. This test is employed to investigate changes in the electrical conductivity of the oil, serving as a crucial performance indicator for assessing its surge current withstand capability. Experimental results on the surge degradation of the natural ester oil are compared to those of gas-to-liquid oil, which is commonly used in power transformers. A discussion is made on the possible use of natural ester oils as a liquid matrix for environmentally friendly surge-proof nanofluids to substitute transformer oils, which are commonly employed as insulating liquids and coolants in the power industry.
- 3 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (6) , 8362-8370
Surge Current Withstand Capability of Natural Ester Oil: A Comparison to Gas-to-Liquid Transformer Oil
The basic electrical characteristics of a natural ester oil are experimentally investigated and compared to gas-to-liquid transformer oil with emphasis given to the endurance against surge events. An accelerated degradation test is conducted using a sequence of current impulses generated through a combination wave generator. This test is employed to investigate changes in the electrical conductivity of the oil, serving as a crucial performance indicator for assessing its surge current withstand capability. Experimental results on the surge degradation of the natural ester oil are compared to those of gas-to-liquid oil, which is commonly used in power transformers. A discussion is made on the possible use of natural ester oils as a liquid matrix for environmentally friendly surge-proof nanofluids to substitute transformer oils, which are commonly employed as insulating liquids and coolants in the power industry.
- 19 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (6) , 8353-8361
Evaluation of the Electric Stress on an Insulating Down-Conductor Caused by Lightning Strikes Through ATP-EMTP Simulations
Electrically insulated lightning protection systems, LPS, utilize insulating stand-offs and insulating down-conductors to maintain the required separation distance from grounded objects. An equivalent separation distance offered by these insulating components can be determined through comparative tests, such as those suggested in IEC TS 62561-8:2018, where crossed-conductors air gaps under negative standard lightning impulse voltages are used as reference. However, in service the insulating components of an electrically insulated LPS are stressed by non-standard fast-front overvoltages related to lightning return-stroke currents. In this study the electric stress experienced by the insulating components of an electrically insulated LPS utilizing a single air terminal, connected to the grounding system via an insulating down-conductor, due to direct negative lightning flashes is assessed through ATP-EMTP simulations. The ground resistance of the LPS grounding system, the length and the resistance of the semiconductive screens of the insulating down-conductor, as well as the characteristics of the lightning return-stroke current were considered as parameters affecting the fast-front overvoltages. For an evaluated electrically insulated LPS the critical lightning currents causing failure of internal and external insulation can be determined; thus, creepages and clearances, as well as the dielectric strength of internal insulation ensuring a safe design against lightning overvoltages can be determined.
- 19 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (6) , 8353-8361
Evaluation of the Electric Stress on an Insulating Down-Conductor Caused by Lightning Strikes Through ATP-EMTP Simulations
Electrically insulated lightning protection systems, LPS, utilize insulating stand-offs and insulating down-conductors to maintain the required separation distance from grounded objects. An equivalent separation distance offered by these insulating components can be determined through comparative tests, such as those suggested in IEC TS 62561-8:2018, where crossed-conductors air gaps under negative standard lightning impulse voltages are used as reference. However, in service the insulating components of an electrically insulated LPS are stressed by non-standard fast-front overvoltages related to lightning return-stroke currents. In this study the electric stress experienced by the insulating components of an electrically insulated LPS utilizing a single air terminal, connected to the grounding system via an insulating down-conductor, due to direct negative lightning flashes is assessed through ATP-EMTP simulations. The ground resistance of the LPS grounding system, the length and the resistance of the semiconductive screens of the insulating down-conductor, as well as the characteristics of the lightning return-stroke current were considered as parameters affecting the fast-front overvoltages. For an evaluated electrically insulated LPS the critical lightning currents causing failure of internal and external insulation can be determined; thus, creepages and clearances, as well as the dielectric strength of internal insulation ensuring a safe design against lightning overvoltages can be determined.
- Open Access
- 1 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (2) , 2611-2620
Evaluation of the Backflashover Performance of a 150 kV Overhead Transmission Line Considering Frequency- and Current-Dependent Effects of Tower Grounding Systems
The influence of the frequency- and current-dependent response of tower grounding systems on evaluating the backflash over performance of a typical 150 kV overhead transmission line is investigated in this study. This is achieved by adopting different tower grounding system modeling approaches in ATP-EMTP simulations: 1) a simple resistor (constant resistance value), 2) the frequency dependent (FD) grounding system response with constant electrical properties of soil, 3) the FD response with FD soil properties, and 4) a soil ionization model. FD responses for concentrated and extended tower grounding systems are obtained via a hybrid method based on electromagnetic field analysis and circuit theory. Backflashover rate, BFR, is estimated by obtaining the minimum backflashover current of the line through ATP-EMTP simulations. Different first return-stroke currents of negative downward lightning flashes are employed in simulations, namely CIGRE WG 33.01 waveforms considering the statistical distributions of their parameters, recorded waveforms, and approximations of the latter with the CIGRE waveform. The impact of the lightning peak current distribution on BFR results is assessed. The evaluated backflashover performance is affected considerably by the FD tower grounding system response for extended systems, whereas by soil ionization for concentrated systems; for the latter, FD effects influence BFR mainly for low soil resistivity values.
- 1 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (2) , 2611-2620
Open AccessEvaluation of the Backflashover Performance of a 150 kV Overhead Transmission Line Considering Frequency- and Current-Dependent Effects of Tower Grounding Systems
The influence of the frequency- and current-dependent response of tower grounding systems on evaluating the backflash over performance of a typical 150 kV overhead transmission line is investigated in this study. This is achieved by adopting different tower grounding system modeling approaches in ATP-EMTP simulations: 1) a simple resistor (constant resistance value), 2) the frequency dependent (FD) grounding system response with constant electrical properties of soil, 3) the FD response with FD soil properties, and 4) a soil ionization model. FD responses for concentrated and extended tower grounding systems are obtained via a hybrid method based on electromagnetic field analysis and circuit theory. Backflashover rate, BFR, is estimated by obtaining the minimum backflashover current of the line through ATP-EMTP simulations. Different first return-stroke currents of negative downward lightning flashes are employed in simulations, namely CIGRE WG 33.01 waveforms considering the statistical distributions of their parameters, recorded waveforms, and approximations of the latter with the CIGRE waveform. The impact of the lightning peak current distribution on BFR results is assessed. The evaluated backflashover performance is affected considerably by the FD tower grounding system response for extended systems, whereas by soil ionization for concentrated systems; for the latter, FD effects influence BFR mainly for low soil resistivity values.
- 11 July 2023
- Published by Elsevier in Electric Power Systems Research
- Vol. 223
Transient induced voltages on aboveground pipelines parallel to overhead transmission lines
- 11 July 2023
- Published by Elsevier in Electric Power Systems Research
- Vol. 223
Transient induced voltages on aboveground pipelines parallel to overhead transmission lines