YJYolanda Jiménez

Yolanda Jiménez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yolanda Jiménez has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Coupled Thickness Shear Mode Resonators for Robust Differential and Multiplexed Acoustic Biosensing

    by Favián Leonardo Moncada Pinzón, Elena Ramírez Sánchez, Augusto Juste-Dolz, Yolanda Jiménez, Yolanda Moreno, Antonio Arnau, María Isabel Rocha-Gaso, Román Fernández

    Acoustic biosensors in liquid media are vulnerable to environmental perturbations that degrade frequency stability and detection resolution. Quartz crystal microbalance (QCM), the benchmark acoustic sensing technology, relies on single-resonator frequency shifts and is therefore sensitive to temperature and flow variations, often requiring external reference channels that add system complexity Here, we evaluate Coupled Thickness Shear Mode (CTSM) resonators as an intrinsically differential acoustic architecture and benchmark their performance against conventional QCM sensors. CTSM devices integrate two weakly coupled thickness-shear resonators within a single quartz substrate, in which asymmetric loading redistributes vibrational energy between coupled modes. This approach provides differential readout (ΔG) while retaining access to the resonance frequency measurement (fs1, fs2). Using a BSA-biotin/Neutravidin model system, CTSM achieves limits of detection (0.78 µg·mL⁻¹) comparable to QCM (0.63 µg·mL⁻¹), while demonstrating improved robustness against temperature and flow perturbations and enhanced long-term stability through intrinsic common-mode rejection. Furthermore, independent functionalization of each resonator enables dual-analyte discrimination within a single sensor, as demonstrated using mixtures of anti-OXA and anti-VIM antibodies on resonators functionalized with the corresponding clinically relevant OXA and VIM carbapenemases associated with antimicrobial resistance. These capabilities are achieved without increasing device footprint or duplicating electronics, as both resonators operate through a single electrical interface. Together, these results position CTSM as a compact, differential, and multiplexed acoustic platform for robust biosensing in liquid environments.

  • Open Access

    A Differential Mass Sensor Based on Two Weakly Coupled Thickness Shear Resonators

    by Roman Fernandez, Maria Calero, Augusto Juste-Dolz, Yolanda Jimenez, Antonio Arnau

  • Open Access

    High Fundamental Frequency (HFF) Monolithic Quartz Crystal Microbalance with Dissipation Array for the Simultaneous Detection of Pesticides and Antibiotics in Complex Food

    by María Calero, Román Fernández, María García, Marisol Juan-Borrás, Isabel Escriche, Antonio Arnau, Ángel Montoya, Yolanda Jiménez

    As in the case of the food industry in general, there is a global concern about safety and quality in complex food matrices, such as honey, which is driving the demand for fast, sensitive and affordable analytical techniques across the honey-packaging industry. Although excellent techniques such as liquid chromatography-tandem mass spectrometry (LC-MS/MS) are available, these are located in centralized laboratories and are still lacking in speed, simplicity and cost-effectiveness. Here, a new approach is presented where a competitive immunoassay is combined with a novel High Fundamental Frequency Quartz Crystal Microbalance with Dissipation (HFF-QCMD) array biosensor for the simultaneous detection of antibiotics and pesticides in honey. Concretely, thiabendazole and sulfathiazole residues were monitored in spiked honey samples. Results revealed that HFF-QCMD arrays provide a complementary and reliable tool to LC-MS/MS for the analysis of contaminants in these kinds of complex matrices, while avoiding elaborate sample pre-treatment. The good sensitivity achieved (I50 values in the 70–720 µg/kg range) and the short analysis time (60 min for 24 individual assays), together with the ability for multiple analyte detection (24 sensor array) and its cost-effectiveness, pave the way for the implementation of a fast on-line, in situ routine control of potentially hazardous chemical residues in honey.


  • Open Access

    A Real-Time Method for Improving Stability of Monolithic Quartz Crystal Microbalance Operating under Harsh Environmental Conditions

    by Román Fernández, María Calero, Yolanda Jiménez, Antonio Arnau

    Monolithic quartz crystal microbalance (MQCM) has recently emerged as a very promising technology suitable for biosensing applications. These devices consist of an array of miniaturized QCM sensors integrated within the same quartz substrate capable of detecting multiple target analytes simultaneously. Their relevant benefits include high throughput, low cost per sensor unit, low sample/reagent consumption and fast sensing response. Despite the great potential of MQCM, unwanted environmental factors (e.g., temperature, humidity, vibrations, or pressure) and perturbations intrinsic to the sensor setup (e.g., mechanical stress exerted by the measurement cell or electronic noise of the characterization system) can affect sensor stability, masking the signal of interest and degrading the limit of detection (LoD). Here, we present a method based on the discrete wavelet transform (DWT) to improve the stability of the resonance frequency and dissipation signals in real time. The method takes advantage of the similarity among the noise patterns of the resonators integrated in an MQCM device to mitigate disturbing factors that impact on sensor response. Performance of the method is validated by studying the adsorption of proteins (neutravidin and biotinylated albumin) under external controlled factors (temperature and pressure/flow rate) that simulate unwanted disturbances.


  • A Fast Method for Monitoring the Shifts in Resonance Frequency and Dissipation of the QCM Sensors of a Monolithic Array in Biosensing Applications

    by Roman Fernandez, Maria Calero, Jose Vicente Garcia-Narbon, Ilya Reviakine, Antonio Arnau, Yolanda Jimenez

    Improvement of data acquisition rate remains as an important challenge in applications with Quartz Crystal Microbalance (QCM) technology where high throughput is required. To address this challenge, we developed a fast method capable of measuring the response of a large number of sensors and/or overtones, with a high time resolution. Our method, which can be implemented in a low-cost readout electronic circuit, is based on the estimation of Δfr (frequency shift) and ΔD (dissipation shift) from measurements of the sensor response obtained at a single driving frequency. By replacing slow fitting procedures with a direct calculation, the time resolution is only limited by the physical characteristics of the sensor (resonance frequency and quality factor), but not by the method itself. Capabilities of the method are demonstrated by monitoring multiple overtones with a single 5 MHz sensor and a Monolithic QCM array comprising 24 50MHz-sensors. Accuracy of the method is validated and compared with the state-of-the-art, as well as with a reference method based on impedance analysis.


  • Open Access

    A Multichannel Microfluidic Sensing Cartridge for Bioanalytical Applications of Monolithic Quartz Crystal Microbalance

    by María Calero, Román Fernández, Pablo García, José Vicente García, María García, Esther Gamero-Sandemetrio, Ilya Reviakine, Antonio Arnau, Yolanda Jiménez

    Integrating acoustic wave sensors into lab-on-a-chip (LoC) devices is a well-known challenge. We address this challenge by designing a microfluidic device housing a monolithic array of 24 high-fundamental frequency quartz crystal microbalance with dissipation (HFF-QCMD) sensors. The device features six 6-µL channels of four sensors each for low-volume parallel measurements, a sealing mechanism that provides appropriate pressure control while assuring liquid confinement and maintaining good stability, and provides a mechanical, electrical, and thermal interface with the characterization electronics. We validate the device by measuring the response of the HFF-QCMD sensors to the air-to-liquid transition, for which the robust Kanazawa–Gordon–Mason theory exists, and then by studying the adsorption of model bioanalytes (neutravidin and biotinylated albumin). With these experiments, we show how the effects of the protein–surface interactions propagate within adsorbed protein multilayers, offering essentially new insight into the design of affinity-based bioanalytical sensors.


  • Open Access

    A considerable improvement of the traditional FPGA-based digital design methodology by using an Arduino sensor board

    by Marcos Martinez Peiro, Miguel Larrea Torres, Jose-Vte Lidón Roger, Yolanda Jiménez Jiménez, Rubén Torres-Curado, Angel Tebar Ruiz

    The traditional way to learn and teach Digital Systems has been changing over the last decades by the use of Hardware Description Languages (HDL) and Field Programmable Gate Array (FPGA) evaluation boards. The use of an Arduino development kit with different sensors connected to the FPGA upsizes the students experience in the area of Digital Systems. A temperature and humidity ambience sensor combined with an ultrasound sensor to measure distance can effectively be used by students to implement its first serial data converter that takes the sensor data and shows the obtained values from the Arduino in the seven segment display of the FPGA kit. After three years of experience in the new grade courses at the UPV Telecommunication School the number of students enjoying this new way to learn the subject Fundamentals of Digital Electronics (FSD) has dramatically risen up with an increase of a 20% in the number of students that pass the subject and that select the electronic branch of telecommunication studies in the future semesters

  • A novel bismuth-based lead-free piezoelectric transducer immunosensor for carbaryl quantification

    by D.A. Fernández-Benavides, L. Cervera-Chiner, Y. Jiménez, O. Arias de Fuentes, A. Montoya, J. Muñoz-Saldaña


  • Open Access

    Design and Validation of a 150 MHz HFFQCM Sensor for Bio-Sensing Applications

    by Román Fernández, Pablo García, María García, José V. García, Yolanda Jiménez, Antonio Arnau

    Acoustic wave resonators have become suitable devices for a broad range of sensing applications due to their sensitivity, low cost, and integration capability, which are all factors that meet the requirements for the resonators to be used as sensing elements for portable point of care (PoC) platforms. In this work, the design, characterization, and validation of a 150 MHz high fundamental frequency quartz crystal microbalance (HFF-QCM) sensor for bio-sensing applications are introduced. Finite element method (FEM) simulations of the proposed design are in good agreement with the electrical characterization of the manufactured resonators. The sensor is also validated for bio-sensing applications. For this purpose, a specific sensor cell was designed and manufactured that addresses the critical requirements associated with this type of sensor and application. Due to the small sensing area and the sensor’s fragility, these requirements include a low-volume flow chamber in the nanoliter range, and a system approach that provides the appropriate pressure control for assuring liquid confinement while maintaining the integrity of the sensor with a good base line stability and easy sensor replacement. The sensor characteristics make it suitable for consideration as the elemental part of a sensor matrix in a multichannel platform for point of care applications.


  • Open Access

    Love Wave Immunosensor for the Detection of Carbaryl Pesticide

    by María-Isabel Rocha-Gaso, José-Vicente García, Pablo García, Carmen March-Iborra, Yolanda Jiménez, Laurent-Alain Francis, Ángel Montoya, Antonio Arnau

    A Love Wave (LW) immunosensor was developed for the detection of carbaryl pesticide. The experimental setup consisted on: a compact electronic characterization circuit based on phase and amplitude detection at constant frequency; an automated flow injection system; a thermal control unit; a custom-made flow-through cell; and Quartz /SiO2 LW sensors with a 40 μm wavelength and 120 MHz center frequency. The carbaryl detection was based on a competitive immunoassay format using LIB-CNH45 monoclonal antibody (MAb). Bovine Serum Albumin-CNH (BSA-CNH) carbaryl hapten-conjugate was covalently immobilized, via mercaptohexadecanoic acid self-assembled monolayer (SAM), onto the gold sensing area of the LW sensors. This immobilization allowed the reusability of the sensor for at least 70 assays without significant signal losses. The LW immunosensor showed a limit of detection (LOD) of 0.09 μg/L, a sensitivity of 0.31 μg/L and a linear working range of 0.14–1.63 μg/L. In comparison to other carbaryl immunosensors, the LW immunosensor achieved a high sensitivity and a low LOD. These features turn the LW immunosensor into a promising tool for applications that demand a high resolution, such as for the detection of pesticides in drinking water at European regulatory levels.