Ralf Gutjahr
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ralf Gutjahr has a total of 81 co-authors. Here are the top co-authors by number of shared publications:
- Bernhard Schmidt
Siemens Healthcare GmbH, 91052 Erlangen, Germany
6 shared publications - Thomas Flohr
Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich , 8091 Zurich
5 shared publications - Gregor Jost
Univerza v Mariboru, Fakulteta za elektrotehniko, računalništvo in informatiko
4 shared publications - Hubertus Pietsch
From the Bayer AG, Radiology, Berlin, Germany (T.F., H.P., L.S., J.E.); Wels - Omnino Medico, Rotkreuz, Switzerland (T.W.); Bayer U.S. LLC, Indianola, PA (P.S.); and Department of Gynecology, Obstetrics and Reproductive Medicine, University Medical School of Saarland, Homburg/Saar, Germany (J.E.)
4 shared publications Bernhard Schmidt
3 shared publications- Bibi Martens
Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Maastricht, The Netherlands
3 shared publications
Latest Publications
- Open Access
- 9 November 2026
- Published by Wolters Kluwer Health in Investigative Radiology
Can CT Phantoms Produce Realistic CT Images of Human Anatomy? Physics-Based Evaluation of Multimaterial 3D-Printed CT Phantoms From CT Data
Objectives: Patient-specific computed tomography (CT) phantoms can be produced using a novel 3D-printing technique that aims at replicating measured CT image volumes with high anatomic fidelity and accurate CT values. The purpose of this study is a comprehensive physics-based evaluation of both technical phantoms and a full-size adult abdominal phantom with regard to image-quality metrics and the reproducibility of CT values. In addition, the visualization of abdominal pathologies will be assessed. Materials and Methods: The study was conducted in 3 steps. First, a geometric reference disc phantom (40 mm thickness, 150 mm diameter) was 3D-printed using multimaterial jetting and scanned on a commercial photon-counting detector CT (PCD-CT) to assess the CT values of the base materials used for printing and to evaluate the influence of the printing process on spatial resolution and noise properties. Second, CT images of the reference phantom reconstructed with a medium-sharp and a sharp kernel were used as templates to print 2 CT-derived disc phantoms using multimaterial jetting with voxel-based material mapping. These phantoms were then scanned to assess how template image sharpness propagates into the image-quality properties of the final printed phantoms. Spatial resolution was evaluated using edge spread function (ESF) analysis and edge rise distance (ERD), whereas noise characteristics were assessed using noise power spectrum (NPS) analysis. Third, as a proof of concept, a full-size adult abdominal phantom was 3D-printed with a patient CT data set as template. Phantom images were compared with patient images regarding CT values, spatial resolution, noise properties, and the depiction of pathologic structures. Results: Evaluation of the CT attenuation of the base materials showed that CT values ranging from −37 HU to 995 HU in virtual monoenergetic images at 60 keV can be printed. For the reference disc, measured ESF curves showed close agreement with theoretical expectations across all reconstruction kernels, indicating preservation of spatial resolution by the printing process. CT-derived discs showed minor edge smoothing compared with the reference for smooth and medium-sharp reconstructions. For sharp reconstructions, edge smoothing was severe, with an ERD increase of up to 32% compared with the reference. Edge smoothing was more pronounced for the disc based on a sharp template. NPS were highly consistent across all discs, with only minor differences in peak amplitude. In the abdominal phantom images ESF and NPS closely matched those of the patient CT images. Measured attenuation agreed well for tissues with positive CT values up to 1000 HU. Fat was represented with increased CT values because of print material limitations. Clinically relevant pathologic structures, including a large hepatocellular carcinoma and a smaller focal liver lesion, were displayed comparably in the phantom images. Conclusions: CT phantoms generated from CT image volumes using 3D printing with multimaterial mapping on a voxel level accurately reproduce the template images in terms of image sharpness, noise characteristics, and attenuation properties of tissues with positive CT values not exceeding 1000 HU. The achievable spatial resolution is limited to medium-sharp levels and does not improve by using sharper template images. These findings support the use of image-based multimaterial 3D printing to produce realistic anthropomorphic phantoms for advanced CT image-quality assessment and optimization, and for validation of reconstruction algorithms and quantitative CT imaging methods.
- 9 November 2026
- Published by Wolters Kluwer Health in Investigative Radiology
Open AccessCan CT Phantoms Produce Realistic CT Images of Human Anatomy? Physics-Based Evaluation of Multimaterial 3D-Printed CT Phantoms From CT Data
Objectives: Patient-specific computed tomography (CT) phantoms can be produced using a novel 3D-printing technique that aims at replicating measured CT image volumes with high anatomic fidelity and accurate CT values. The purpose of this study is a comprehensive physics-based evaluation of both technical phantoms and a full-size adult abdominal phantom with regard to image-quality metrics and the reproducibility of CT values. In addition, the visualization of abdominal pathologies will be assessed. Materials and Methods: The study was conducted in 3 steps. First, a geometric reference disc phantom (40 mm thickness, 150 mm diameter) was 3D-printed using multimaterial jetting and scanned on a commercial photon-counting detector CT (PCD-CT) to assess the CT values of the base materials used for printing and to evaluate the influence of the printing process on spatial resolution and noise properties. Second, CT images of the reference phantom reconstructed with a medium-sharp and a sharp kernel were used as templates to print 2 CT-derived disc phantoms using multimaterial jetting with voxel-based material mapping. These phantoms were then scanned to assess how template image sharpness propagates into the image-quality properties of the final printed phantoms. Spatial resolution was evaluated using edge spread function (ESF) analysis and edge rise distance (ERD), whereas noise characteristics were assessed using noise power spectrum (NPS) analysis. Third, as a proof of concept, a full-size adult abdominal phantom was 3D-printed with a patient CT data set as template. Phantom images were compared with patient images regarding CT values, spatial resolution, noise properties, and the depiction of pathologic structures. Results: Evaluation of the CT attenuation of the base materials showed that CT values ranging from −37 HU to 995 HU in virtual monoenergetic images at 60 keV can be printed. For the reference disc, measured ESF curves showed close agreement with theoretical expectations across all reconstruction kernels, indicating preservation of spatial resolution by the printing process. CT-derived discs showed minor edge smoothing compared with the reference for smooth and medium-sharp reconstructions. For sharp reconstructions, edge smoothing was severe, with an ERD increase of up to 32% compared with the reference. Edge smoothing was more pronounced for the disc based on a sharp template. NPS were highly consistent across all discs, with only minor differences in peak amplitude. In the abdominal phantom images ESF and NPS closely matched those of the patient CT images. Measured attenuation agreed well for tissues with positive CT values up to 1000 HU. Fat was represented with increased CT values because of print material limitations. Clinically relevant pathologic structures, including a large hepatocellular carcinoma and a smaller focal liver lesion, were displayed comparably in the phantom images. Conclusions: CT phantoms generated from CT image volumes using 3D printing with multimaterial mapping on a voxel level accurately reproduce the template images in terms of image sharpness, noise characteristics, and attenuation properties of tissues with positive CT values not exceeding 1000 HU. The achievable spatial resolution is limited to medium-sharp levels and does not improve by using sharper template images. These findings support the use of image-based multimaterial 3D printing to produce realistic anthropomorphic phantoms for advanced CT image-quality assessment and optimization, and for validation of reconstruction algorithms and quantitative CT imaging methods.
- 2 October 2025
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 61 (6) , 395-403
Multicontrast Multiphase Intestinal Imaging Using Photon-Counting CT
Objectives: The aim of this study is to validate a 3-material decomposition algorithm for distinguishing between 2 contrast media (CM) (iodine-based and tungsten-based) and water in vivo using a commercial photon-counting CT (PCCT) unit, able to acquire 4 energy thresholds simultaneously. Materials and Methods: Six healthy rats were imaged during different CM distribution phases with both iodine-based and tungsten-based CM present in the animals, one administered orally and one intravenously. Material decomposition was used to compute quantitative contrast maps, virtual noncontrast (VNC) maps, and virtual monoenergetic images (VMI). The mean enhancement in CM-filled regions and in CM-free muscle was measured. This prospective preclinical study was conducted in accordance with the German Animal Welfare Act guidelines and with the approval of the local state animal welfare committee. Results: Iodine-filled regions were exclusively enhanced (PP<0.001) in the tungsten map. VNC maps of a 3-material decomposition received no additional enhancement by CM. VMI, incorporating both iodine and tungsten CM, of different energy levels indicated the K-edge of tungsten. Conclusions: This study successfully demonstrated the capability of PCCT combined with material decomposition to delineate 2 CM and water in rats. The contrast dynamics of the 2 CM in the vessels (aorta and vena cava) and intestines were successfully reproduced in the CM maps. VNC maps may omit the need for CT scans before contrast administration. VMI revealed distinct energy-dependent attenuation profiles of the given materials.
- 2 October 2025
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 61 (6) , 395-403
Multicontrast Multiphase Intestinal Imaging Using Photon-Counting CT
Objectives: The aim of this study is to validate a 3-material decomposition algorithm for distinguishing between 2 contrast media (CM) (iodine-based and tungsten-based) and water in vivo using a commercial photon-counting CT (PCCT) unit, able to acquire 4 energy thresholds simultaneously. Materials and Methods: Six healthy rats were imaged during different CM distribution phases with both iodine-based and tungsten-based CM present in the animals, one administered orally and one intravenously. Material decomposition was used to compute quantitative contrast maps, virtual noncontrast (VNC) maps, and virtual monoenergetic images (VMI). The mean enhancement in CM-filled regions and in CM-free muscle was measured. This prospective preclinical study was conducted in accordance with the German Animal Welfare Act guidelines and with the approval of the local state animal welfare committee. Results: Iodine-filled regions were exclusively enhanced (PP<0.001) in the tungsten map. VNC maps of a 3-material decomposition received no additional enhancement by CM. VMI, incorporating both iodine and tungsten CM, of different energy levels indicated the K-edge of tungsten. Conclusions: This study successfully demonstrated the capability of PCCT combined with material decomposition to delineate 2 CM and water in rats. The contrast dynamics of the 2 CM in the vessels (aorta and vena cava) and intestines were successfully reproduced in the CM maps. VNC maps may omit the need for CT scans before contrast administration. VMI revealed distinct energy-dependent attenuation profiles of the given materials.
- Open Access
- 10 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Visualization and Computer Graphics
- Vol. 31 (5) , 2353-2363
Multi-Layer Gaussian Splatting for Immersive Anatomy Visualization
In medical image visualization, path tracing of volumetric medical data like computed tomography (CT) scans produces lifelike three-dimensional visualizations. Immersive virtual reality (VR) displays can further enhance the understanding of complex anatomies. Going beyond the diagnostic quality of traditional 2D slices, they enable interactive 3D evaluation of anatomies, supporting medical education and planning. Rendering high-quality visualizations in real-time, however, is computationally intensive and impractical for compute-constrained devices like mobile headsets. We propose a novel approach utilizing Gaussian Splatting (GS) to create an efficient but static intermediate representation of CT scans. We introduce a layered GS representation, incrementally including different anatomical structures while minimizing overlap and extending the GS training to remove inactive Gaussians. We further compress the created model with clustering across layers. Our approach achieves interactive frame rates while preserving anatomical structures, with quality adjustable to the target hardware. Compared to standard GS, our representation retains some of the explorative qualities initially enabled by immersive path tracing. Selective activation and clipping of layers are possible at rendering time, adding a degree of interactivity to otherwise static GS models. This could enable scenarios where high computational demands would otherwise prohibit using path-traced medical volumes.
- 10 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Visualization and Computer Graphics
- Vol. 31 (5) , 2353-2363
Open AccessMulti-Layer Gaussian Splatting for Immersive Anatomy Visualization
In medical image visualization, path tracing of volumetric medical data like computed tomography (CT) scans produces lifelike three-dimensional visualizations. Immersive virtual reality (VR) displays can further enhance the understanding of complex anatomies. Going beyond the diagnostic quality of traditional 2D slices, they enable interactive 3D evaluation of anatomies, supporting medical education and planning. Rendering high-quality visualizations in real-time, however, is computationally intensive and impractical for compute-constrained devices like mobile headsets. We propose a novel approach utilizing Gaussian Splatting (GS) to create an efficient but static intermediate representation of CT scans. We introduce a layered GS representation, incrementally including different anatomical structures while minimizing overlap and extending the GS training to remove inactive Gaussians. We further compress the created model with clustering across layers. Our approach achieves interactive frame rates while preserving anatomical structures, with quality adjustable to the target hardware. Compared to standard GS, our representation retains some of the explorative qualities initially enabled by immersive path tracing. Selective activation and clipping of layers are possible at rendering time, adding a degree of interactivity to otherwise static GS models. This could enable scenarios where high computational demands would otherwise prohibit using path-traced medical volumes.
- Open Access
Multi-Layer Gaussian Splatting for Immersive Anatomy Visualization
In medical image visualization, path tracing of volumetric medical data like CT scans produces lifelike three-dimensional visualizations. Immersive VR displays can further enhance the understanding of complex anatomies. Going beyond the diagnostic quality of traditional 2D slices, they enable interactive 3D evaluation of anatomies, supporting medical education and planning. Rendering high-quality visualizations in real-time, however, is computationally intensive and impractical for compute-constrained devices like mobile headsets. We propose a novel approach utilizing GS to create an efficient but static intermediate representation of CT scans. We introduce a layered GS representation, incrementally including different anatomical structures while minimizing overlap and extending the GS training to remove inactive Gaussians. We further compress the created model with clustering across layers. Our approach achieves interactive frame rates while preserving anatomical structures, with quality adjustable to the target hardware. Compared to standard GS, our representation retains some of the explorative qualities initially enabled by immersive path tracing. Selective activation and clipping of layers are possible at rendering time, adding a degree of interactivity to otherwise static GS models. This could enable scenarios where high computational demands would otherwise prohibit using path-traced medical volumes.
Open AccessMulti-Layer Gaussian Splatting for Immersive Anatomy Visualization
In medical image visualization, path tracing of volumetric medical data like CT scans produces lifelike three-dimensional visualizations. Immersive VR displays can further enhance the understanding of complex anatomies. Going beyond the diagnostic quality of traditional 2D slices, they enable interactive 3D evaluation of anatomies, supporting medical education and planning. Rendering high-quality visualizations in real-time, however, is computationally intensive and impractical for compute-constrained devices like mobile headsets. We propose a novel approach utilizing GS to create an efficient but static intermediate representation of CT scans. We introduce a layered GS representation, incrementally including different anatomical structures while minimizing overlap and extending the GS training to remove inactive Gaussians. We further compress the created model with clustering across layers. Our approach achieves interactive frame rates while preserving anatomical structures, with quality adjustable to the target hardware. Compared to standard GS, our representation retains some of the explorative qualities initially enabled by immersive path tracing. Selective activation and clipping of layers are possible at rendering time, adding a degree of interactivity to otherwise static GS models. This could enable scenarios where high computational demands would otherwise prohibit using path-traced medical volumes.
- Open Access
- 15 May 2024
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 59 (10) , 684-690
Countering Calcium Blooming With Personalized Contrast Media Injection Protocols
Objective: Photon-counting detector computed tomography (PCD-CT) enables spectral data acquisition of CT angiographies allowing for reconstruction of virtual monoenergetic images (VMIs) in routine practice. Specifically, it has potential to reduce the blooming artifacts associated with densely calcified plaques. However, calcium blooming and iodine attenuation are inversely affected by energy level (keV) of the VMIs, creating a challenge for contrast media (CM) injection protocol optimization. A pragmatic and simple rule for calcium-dependent CM injection protocols is investigated and proposed for VMI-based coronary CT angiography with PCD-CT. Materials and Methods: A physiological circulation phantom with coronary vessels including calcified lesions (maximum CT value >700 HU) with a 50% diameter stenosis was injected into at iodine delivery rates (IDRs) of 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, 2.5, and 3.0 g I/s. Images were acquired using a first-generation dual-source PCD-CT and reconstructed at various VMI levels (between 45 and 190 keV). Iodine attenuation in the coronaries was measured at each IDR for each keV, and blooming artifacts from the calcified lesions were assessed including stenosis grading error (as % overestimation vs true lumen). The IDR to achieve 300 HU at each VMI level was then calculated and compared with stenosis grading accuracy to establish a general rule for CM injection protocols. Results: Plaque blooming artifacts and intraluminal iodine attenuation decreased with increasing keV. Fixed windowing (representing absolute worst case) resulted in stenosis overestimation from 77% ± 4% at 45 keV to 5% ± 2% at 190 keV, whereas optimized windowing resulted in overestimation from 29% ± 3% at 45 keV to 4% ± 1% at 190 keV. The required IDR to achieve 300 HU showed a strong linear correlation to VMI energy (R 2 = 0.98). Comparison of this linear plot versus stenosis grading error and blooming artifact demonstrated that multipliers of 1, 2, and 3 times the reference IDR for theoretical clinical regimes of no, moderate, and severe calcification density, respectively, can be proposed as a general rule. Conclusions: This study provides a proof-of-concept in an anthropomorphic phantom for a simple pragmatic adaptation of CM injection protocols in coronary CT angiography with PCD-CT. The 1-2-3 rule demonstrates the potential for reducing the effects of calcium blooming artifacts on overall image quality.
- 15 May 2024
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 59 (10) , 684-690
Open AccessCountering Calcium Blooming With Personalized Contrast Media Injection Protocols
Objective: Photon-counting detector computed tomography (PCD-CT) enables spectral data acquisition of CT angiographies allowing for reconstruction of virtual monoenergetic images (VMIs) in routine practice. Specifically, it has potential to reduce the blooming artifacts associated with densely calcified plaques. However, calcium blooming and iodine attenuation are inversely affected by energy level (keV) of the VMIs, creating a challenge for contrast media (CM) injection protocol optimization. A pragmatic and simple rule for calcium-dependent CM injection protocols is investigated and proposed for VMI-based coronary CT angiography with PCD-CT. Materials and Methods: A physiological circulation phantom with coronary vessels including calcified lesions (maximum CT value >700 HU) with a 50% diameter stenosis was injected into at iodine delivery rates (IDRs) of 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, 2.5, and 3.0 g I/s. Images were acquired using a first-generation dual-source PCD-CT and reconstructed at various VMI levels (between 45 and 190 keV). Iodine attenuation in the coronaries was measured at each IDR for each keV, and blooming artifacts from the calcified lesions were assessed including stenosis grading error (as % overestimation vs true lumen). The IDR to achieve 300 HU at each VMI level was then calculated and compared with stenosis grading accuracy to establish a general rule for CM injection protocols. Results: Plaque blooming artifacts and intraluminal iodine attenuation decreased with increasing keV. Fixed windowing (representing absolute worst case) resulted in stenosis overestimation from 77% ± 4% at 45 keV to 5% ± 2% at 190 keV, whereas optimized windowing resulted in overestimation from 29% ± 3% at 45 keV to 4% ± 1% at 190 keV. The required IDR to achieve 300 HU showed a strong linear correlation to VMI energy (R 2 = 0.98). Comparison of this linear plot versus stenosis grading error and blooming artifact demonstrated that multipliers of 1, 2, and 3 times the reference IDR for theoretical clinical regimes of no, moderate, and severe calcification density, respectively, can be proposed as a general rule. Conclusions: This study provides a proof-of-concept in an anthropomorphic phantom for a simple pragmatic adaptation of CM injection protocols in coronary CT angiography with PCD-CT. The 1-2-3 rule demonstrates the potential for reducing the effects of calcium blooming artifacts on overall image quality.
- Open Access
- 25 March 2024
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 59 (10) , 677-683
Tungsten-Based Contrast Agent for Photon-Counting Detector CT Angiography in Calcified Coronaries
Objectives: Calcified plaques induce blooming artifacts in coronary computed tomography angiography (CCTA) potentially leading to inaccurate stenosis evaluation. Tungsten represents a high atomic number, experimental contrast agent with different physical properties than iodine. We explored the potential of a tungsten-based contrast agent for photon-counting detector (PCD) CCTA in heavily calcified coronary vessels. Materials and Methods: A cardiovascular phantom exhibiting coronaries with calcified plaques was imaged on a first-generation dual-source PCD-CT. The coronaries with 3 different calcified plaques were filled with iodine and tungsten contrast media solutions equating to iodine and tungsten delivery rates (IDR and TDR) of 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, 2.5, and 3.0 g/s, respectively. Electrocardiogram-triggered sequential acquisitions were performed in the spectral mode (QuantumPlus). Virtual monoenergetic images (VMIs) were reconstructed from 40 to 190 keV in 1 keV increments. Blooming artifacts and percentage error stenoses from calcified plaques were quantified, and attenuation characteristics of both contrast media were recorded. Results: Blooming artifacts from calcified plaques were most pronounced at 40 keV (78%) and least pronounced at 190 keV (58%). Similarly, percentage error stenoses were highest at 40 keV (48%) and lowest at 190 keV (2%), respectively. Attenuation of iodine decreased monotonically in VMIs from low to high keV, with the strongest decrease from 40 keV to 100 keV (IDR of 2.5 g/s: 1279 HU at 40 keV, 187 HU at 100 kV, and 35 HU at 190 keV). The attenuation of tungsten, on the other hand, increased monotonically as a function of VMI energy, with the strongest increase between 40 and 100 keV (TDR of 2.5 g/s: 202 HU at 40 keV, 661 HU at 100 kV, and 717 HU at 190 keV). For each keV level, the relationship between attenuation and IDR/TDR could be described by linear regressions (R 2 ≥ 0.88, P < 0.001). Specifically, attenuation increased linearly when increasing the delivery rate irrespective of keV level or contrast medium. Iodine exhibited the highest relative increase in attenuation values at lower keV levels when increasing the IDR. Conversely, for tungsten, the greatest relative increase in attenuation values occurred at higher keV levels when increasing the TDR. When high keV imaging is desirable to reduce blooming artifacts from calcified plaques, IDR has to be increased at higher keV levels to maintain diagnostic vessel attenuation (ie, 300 HU), whereas for tungsten, TDR can be kept constant or can be even reduced at high keV energy levels. Conclusions: Tungsten's attenuation characteristics in relation to VMI energy levels are reversed to those of iodine, with tungsten exhibiting high attenuation values at high keV levels and vice versa. Thus, tungsten shows promise for high keV imaging CCTA with PCD-CT as—in distinction to iodine—both high vessel attenuation and low blooming artifacts from calcified plaques can be achieved.
- 25 March 2024
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 59 (10) , 677-683
Open AccessTungsten-Based Contrast Agent for Photon-Counting Detector CT Angiography in Calcified Coronaries
Objectives: Calcified plaques induce blooming artifacts in coronary computed tomography angiography (CCTA) potentially leading to inaccurate stenosis evaluation. Tungsten represents a high atomic number, experimental contrast agent with different physical properties than iodine. We explored the potential of a tungsten-based contrast agent for photon-counting detector (PCD) CCTA in heavily calcified coronary vessels. Materials and Methods: A cardiovascular phantom exhibiting coronaries with calcified plaques was imaged on a first-generation dual-source PCD-CT. The coronaries with 3 different calcified plaques were filled with iodine and tungsten contrast media solutions equating to iodine and tungsten delivery rates (IDR and TDR) of 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, 2.5, and 3.0 g/s, respectively. Electrocardiogram-triggered sequential acquisitions were performed in the spectral mode (QuantumPlus). Virtual monoenergetic images (VMIs) were reconstructed from 40 to 190 keV in 1 keV increments. Blooming artifacts and percentage error stenoses from calcified plaques were quantified, and attenuation characteristics of both contrast media were recorded. Results: Blooming artifacts from calcified plaques were most pronounced at 40 keV (78%) and least pronounced at 190 keV (58%). Similarly, percentage error stenoses were highest at 40 keV (48%) and lowest at 190 keV (2%), respectively. Attenuation of iodine decreased monotonically in VMIs from low to high keV, with the strongest decrease from 40 keV to 100 keV (IDR of 2.5 g/s: 1279 HU at 40 keV, 187 HU at 100 kV, and 35 HU at 190 keV). The attenuation of tungsten, on the other hand, increased monotonically as a function of VMI energy, with the strongest increase between 40 and 100 keV (TDR of 2.5 g/s: 202 HU at 40 keV, 661 HU at 100 kV, and 717 HU at 190 keV). For each keV level, the relationship between attenuation and IDR/TDR could be described by linear regressions (R 2 ≥ 0.88, P < 0.001). Specifically, attenuation increased linearly when increasing the delivery rate irrespective of keV level or contrast medium. Iodine exhibited the highest relative increase in attenuation values at lower keV levels when increasing the IDR. Conversely, for tungsten, the greatest relative increase in attenuation values occurred at higher keV levels when increasing the TDR. When high keV imaging is desirable to reduce blooming artifacts from calcified plaques, IDR has to be increased at higher keV levels to maintain diagnostic vessel attenuation (ie, 300 HU), whereas for tungsten, TDR can be kept constant or can be even reduced at high keV energy levels. Conclusions: Tungsten's attenuation characteristics in relation to VMI energy levels are reversed to those of iodine, with tungsten exhibiting high attenuation values at high keV levels and vice versa. Thus, tungsten shows promise for high keV imaging CCTA with PCD-CT as—in distinction to iodine—both high vessel attenuation and low blooming artifacts from calcified plaques can be achieved.
- Top Cited PapersOpen Access
- 11 April 2023
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 58 (7) , 515-522
New Contrast Media for K-Edge Imaging With Photon-Counting Detector CT
The recent technological developments in photon-counting detector computed tomography (PCD-CT) and the introduction of the first commercially available clinical PCD-CT unit open up new exciting opportunities for contrast media research. With PCD-CT, the efficacy of available iodine-based contrast media improves, allowing for a reduction of iodine dosage or, on the other hand, an improvement of image quality in low contrast indications. Virtual monoenergetic image reconstructions are routinely available and enable the virtual monoenergetic image energy to be adapted to the diagnostic task. A key property of PCD-CT is the ability of spectral separation in combination with improved material decomposition. Thus, the discrimination of contrast media from intrinsic or pathological tissues and the discrimination of 2 or more contrasting elements that characterize different tissues are attractive fields for contrast media research. For these approaches, K-edge imaging in combination with high atomic number elements such as the lanthanides, tungsten, tantalum, or bismuth plays a central role. The purpose of this article is to present an overview of innovative contrast media concepts that use high atomic number elements. The emphasis is on improving contrast enhancement for cardiovascular plaque imaging, stent visualization, and exploring new approaches using 2 contrasting elements. Along with the published research, new experimental findings with a contrast medium that incorporates tungsten are included. Both the literature review and the new experimental data demonstrate the great potential and feasibility for new contrast media to significantly increase diagnostic performance and to enable new clinical fields and indications in combination with PCD-CT.
- 11 April 2023
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 58 (7) , 515-522
Top Cited PapersOpen AccessNew Contrast Media for K-Edge Imaging With Photon-Counting Detector CT
The recent technological developments in photon-counting detector computed tomography (PCD-CT) and the introduction of the first commercially available clinical PCD-CT unit open up new exciting opportunities for contrast media research. With PCD-CT, the efficacy of available iodine-based contrast media improves, allowing for a reduction of iodine dosage or, on the other hand, an improvement of image quality in low contrast indications. Virtual monoenergetic image reconstructions are routinely available and enable the virtual monoenergetic image energy to be adapted to the diagnostic task. A key property of PCD-CT is the ability of spectral separation in combination with improved material decomposition. Thus, the discrimination of contrast media from intrinsic or pathological tissues and the discrimination of 2 or more contrasting elements that characterize different tissues are attractive fields for contrast media research. For these approaches, K-edge imaging in combination with high atomic number elements such as the lanthanides, tungsten, tantalum, or bismuth plays a central role. The purpose of this article is to present an overview of innovative contrast media concepts that use high atomic number elements. The emphasis is on improving contrast enhancement for cardiovascular plaque imaging, stent visualization, and exploring new approaches using 2 contrasting elements. Along with the published research, new experimental findings with a contrast medium that incorporates tungsten are included. Both the literature review and the new experimental data demonstrate the great potential and feasibility for new contrast media to significantly increase diagnostic performance and to enable new clinical fields and indications in combination with PCD-CT.
- Open Access
- 3 June 2022
- Published by MDPI AG in Tomography
- Vol. 8 (3) , 1466-1476
Image Quality and Radiation Dose of Contrast-Enhanced Chest-CT Acquired on a Clinical Photon-Counting Detector CT vs. Second-Generation Dual-Source CT in an Oncologic Cohort: Preliminary Results
Our aim was to compare the image quality and patient dose of contrast-enhanced oncologic chest-CT of a first-generation photon-counting detector (PCD-CT) and a second-generation dual-source dual-energy CT (DSCT). For this reason, one hundred consecutive oncologic patients (63 male, 65 ± 11 years, BMI: 16–42 kg/m2) were prospectively enrolled and evaluated. Clinically indicated contrast-enhanced chest-CT were obtained with PCD-CT and compared to previously obtained chest-DSCT in the same individuals. The median time interval between the scans was three months. The same contrast media protocol was used for both scans. PCD-CT was performed in QuantumPlus mode (obtaining full spectral information) at 120 kVp. DSCT was performed using 100 kV for Tube A and 140 kV for Tube B. “T3D” PCD-CT images were evaluated, which emulate conventional 120 keV polychromatic images. For DSCT, the convolution algorithm was set at I31f with class 1 iterative reconstruction, whereas comparable Br40 kernel and iterative reconstruction strengths (Q1 and Q3) were applied for PCD-CT. Two radiologists assessed image quality using a five-point Likert scale and performed measurements of vessels and lung parenchyma for signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and in the case of pulmonary metastases tumor-to-lung parenchyma contrast ratio. PCD-CT CNRvessel was significantly higher than DSCT CNRvessel (all, p < 0.05). Readers rated image contrast of mediastinum, vessels, and lung parenchyma significantly higher in PCD-CT than DSCT images (p < 0.001). Q3 PCD-CT CNRlung_parenchyma was significantly higher than DSCT CNRlung_parenchyma and Q1 PCD-CT CNRlung_parenchyma (p < 0.01). The tumor-to-lung parenchyma contrast ratio was significantly higher on PCD-CT than DSCT images (0.08 ± 0.04 vs. 0.03 ± 0.02, p < 0.001). CTDI, DLP, SSDE mean values for PCD-CT and DSCT were 4.17 ± 1.29 mGy vs. 7.21 ± 0.49 mGy, 151.01 ± 48.56 mGy * cm vs. 288.64 ± 31.17 mGy * cm and 4.23 ± 0.97 vs. 7.48 ± 1.09, respectively. PCD-CT enables oncologic chest-CT with a significantly reduced dose while maintaining image quality similar to a second-generation DSCT for comparable protocol settings.
- 3 June 2022
- Published by MDPI AG in Tomography
- Vol. 8 (3) , 1466-1476
Open AccessImage Quality and Radiation Dose of Contrast-Enhanced Chest-CT Acquired on a Clinical Photon-Counting Detector CT vs. Second-Generation Dual-Source CT in an Oncologic Cohort: Preliminary Results
Our aim was to compare the image quality and patient dose of contrast-enhanced oncologic chest-CT of a first-generation photon-counting detector (PCD-CT) and a second-generation dual-source dual-energy CT (DSCT). For this reason, one hundred consecutive oncologic patients (63 male, 65 ± 11 years, BMI: 16–42 kg/m2) were prospectively enrolled and evaluated. Clinically indicated contrast-enhanced chest-CT were obtained with PCD-CT and compared to previously obtained chest-DSCT in the same individuals. The median time interval between the scans was three months. The same contrast media protocol was used for both scans. PCD-CT was performed in QuantumPlus mode (obtaining full spectral information) at 120 kVp. DSCT was performed using 100 kV for Tube A and 140 kV for Tube B. “T3D” PCD-CT images were evaluated, which emulate conventional 120 keV polychromatic images. For DSCT, the convolution algorithm was set at I31f with class 1 iterative reconstruction, whereas comparable Br40 kernel and iterative reconstruction strengths (Q1 and Q3) were applied for PCD-CT. Two radiologists assessed image quality using a five-point Likert scale and performed measurements of vessels and lung parenchyma for signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and in the case of pulmonary metastases tumor-to-lung parenchyma contrast ratio. PCD-CT CNRvessel was significantly higher than DSCT CNRvessel (all, p < 0.05). Readers rated image contrast of mediastinum, vessels, and lung parenchyma significantly higher in PCD-CT than DSCT images (p < 0.001). Q3 PCD-CT CNRlung_parenchyma was significantly higher than DSCT CNRlung_parenchyma and Q1 PCD-CT CNRlung_parenchyma (p < 0.01). The tumor-to-lung parenchyma contrast ratio was significantly higher on PCD-CT than DSCT images (0.08 ± 0.04 vs. 0.03 ± 0.02, p < 0.001). CTDI, DLP, SSDE mean values for PCD-CT and DSCT were 4.17 ± 1.29 mGy vs. 7.21 ± 0.49 mGy, 151.01 ± 48.56 mGy * cm vs. 288.64 ± 31.17 mGy * cm and 4.23 ± 0.97 vs. 7.48 ± 1.09, respectively. PCD-CT enables oncologic chest-CT with a significantly reduced dose while maintaining image quality similar to a second-generation DSCT for comparable protocol settings.
- 1 May 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1133) , 20201456
Optimization of contrast material administration for coronary CT angiography using a software-based test-bolus evaluation algorithm
Objectives: To evaluate the benefit of a prototype circulation time-based test bolus evaluation algorithm for the individualized optimal timing of contrast media (CM) delivery in patients undergoing coronary CT angiography (CCTA). Methods: Thirty-two patients (62 ± 16 years) underwent CCTA using a prototype bolus evaluation tool to determine the optimal time-delay for CM administration. Contrast attenuation, signal-to-noise ratio (SNR), objective, and subjective image quality were evaluated by two independent radiologists. Results were compared to a control cohort (matched for age, sex, body mass index, and tube voltage) of patients who underwent CCTA using the generic test bolus peak attenuation +4 s protocol as scan delay. Results: In the study group, the mean time delay to CCTA acquisition was significantly longer (26.0 ± 2.9 s) compared to the control group (23.1 ± 3.5 s; p < 0.01). In the study group, SNR improvement was seen in the right coronary artery (17.5 vs 13; p = 0.028), the left main (15.3 vs 12.3; p = 0.027), and the left anterior descending artery (18.5 vs 14.1; p = 0.048). Subjective image quality was rated higher in the study group (4.75 ± 0.7 vs 3.64 ± 0.5; p < 0.001). Conclusions: The prototype test bolus evaluation algorithm provided a reliable patient-specific scan delay for CCTA that ensured homogenous vascular attenuation, improvement in objective and subjective image quality, and avoidance of beam hardening artifacts. Advances in knowledge: The prototype contrast bolus evaluation and optimization tool estimated circulation time-based time-delay improves the overall quality of CCTA.
- 1 May 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1133) , 20201456
Optimization of contrast material administration for coronary CT angiography using a software-based test-bolus evaluation algorithm
Objectives: To evaluate the benefit of a prototype circulation time-based test bolus evaluation algorithm for the individualized optimal timing of contrast media (CM) delivery in patients undergoing coronary CT angiography (CCTA). Methods: Thirty-two patients (62 ± 16 years) underwent CCTA using a prototype bolus evaluation tool to determine the optimal time-delay for CM administration. Contrast attenuation, signal-to-noise ratio (SNR), objective, and subjective image quality were evaluated by two independent radiologists. Results were compared to a control cohort (matched for age, sex, body mass index, and tube voltage) of patients who underwent CCTA using the generic test bolus peak attenuation +4 s protocol as scan delay. Results: In the study group, the mean time delay to CCTA acquisition was significantly longer (26.0 ± 2.9 s) compared to the control group (23.1 ± 3.5 s; p < 0.01). In the study group, SNR improvement was seen in the right coronary artery (17.5 vs 13; p = 0.028), the left main (15.3 vs 12.3; p = 0.027), and the left anterior descending artery (18.5 vs 14.1; p = 0.048). Subjective image quality was rated higher in the study group (4.75 ± 0.7 vs 3.64 ± 0.5; p < 0.001). Conclusions: The prototype test bolus evaluation algorithm provided a reliable patient-specific scan delay for CCTA that ensured homogenous vascular attenuation, improvement in objective and subjective image quality, and avoidance of beam hardening artifacts. Advances in knowledge: The prototype contrast bolus evaluation and optimization tool estimated circulation time-based time-delay improves the overall quality of CCTA.
- 22 April 2022
- Published by Springer Nature
- p. 181-193
Artificial Intelligence Integration into the Computed Tomography System
- 22 April 2022
- Published by Springer Nature
- p. 181-193
Artificial Intelligence Integration into the Computed Tomography System