Giulia Maria Liosi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Giulia Maria Liosi has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Mario Mariani
Department of Energy, Nuclear Engineering Division, Politecnico di Milano, 20156 Milano, Italy
3 shared publications - Francesca Giacobbo
Politecnico di Milano
2 shared publications D. Tagliabue
Department of Energy, Politecnico di Milano, Milano, Italy
1 shared publication- Elena Macerata
Department of Energy, Nuclear Engineering Division, Politecnico di Milano, 20156 Milano, Italy
1 shared publication Emanuele Artuso
INFN, Milan, Italy
1 shared publicationEmanuele Pignoli
Medical Physics Unit, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy
1 shared publication
Latest Publications
- 3 October 2018
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 173 (9-10) , 784-793
Characterization of PAGAT dose response upon different irradiation conditions
Polymer gel dosimeters represent a promising instrument for tridimensional radiation dose measurement for highly conformal radiation therapy techniques. In this study, the dependence of the dose response of the polymeric gel dosimeter PAGAT was investigated as a function of different irradiation conditions and time elapsed after irradiation. An X-ray tube and 60Co sources were used for irradiation. This allowed to assess variations in system dose response under different irradiation energies and dose rates - ranging from 1.4 Gy h-1 up to 0.14 kGy h−1. Analysis of irradiated samples was performed by UV–Vis optical measurements at different time intervals after irradiation. Significant variability in PAGAT dose response was observed for different irradiation conditions and considered dose rates.
- 3 October 2018
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 173 (9-10) , 784-793
Characterization of PAGAT dose response upon different irradiation conditions
Polymer gel dosimeters represent a promising instrument for tridimensional radiation dose measurement for highly conformal radiation therapy techniques. In this study, the dependence of the dose response of the polymeric gel dosimeter PAGAT was investigated as a function of different irradiation conditions and time elapsed after irradiation. An X-ray tube and 60Co sources were used for irradiation. This allowed to assess variations in system dose response under different irradiation energies and dose rates - ranging from 1.4 Gy h-1 up to 0.14 kGy h−1. Analysis of irradiated samples was performed by UV–Vis optical measurements at different time intervals after irradiation. Significant variability in PAGAT dose response was observed for different irradiation conditions and considered dose rates.
- 20 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (9) , 2628-2632
Study on Characteristics of Fricke Xylenol Orange Gelatin Dosimeters
The response of Fricke xylenol orange gelatin dosimeter has been studied to investigate the possibility of achieving a calibration method based on a preirradiation procedure. With this aim, different preirradiation parameters have been tested, and the system response to subsequent irradiations has been investigated. Both Fricke gel layers and cuvettes were considered, and no dependence on shape and wall material was observed. An increase of the system response was observed, depending on the total absorbed dose and not on the number of subsequent irradiations performed, as evidenced by the changes of the absorption spectra shapes. Moreover, different calibration curves, and consequently different sensitivities, were obtained with different preirradiation parameters. In order to propose a calibration procedure, further studies are of fundamental importance to deeper comprehending the influence of preirradiation parameters on the system sensitivity and response. In particular, a systematic analysis of the whole absorption spectra has proved to be central.
- 20 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (9) , 2628-2632
Study on Characteristics of Fricke Xylenol Orange Gelatin Dosimeters
The response of Fricke xylenol orange gelatin dosimeter has been studied to investigate the possibility of achieving a calibration method based on a preirradiation procedure. With this aim, different preirradiation parameters have been tested, and the system response to subsequent irradiations has been investigated. Both Fricke gel layers and cuvettes were considered, and no dependence on shape and wall material was observed. An increase of the system response was observed, depending on the total absorbed dose and not on the number of subsequent irradiations performed, as evidenced by the changes of the absorption spectra shapes. Moreover, different calibration curves, and consequently different sensitivities, were obtained with different preirradiation parameters. In order to propose a calibration procedure, further studies are of fundamental importance to deeper comprehending the influence of preirradiation parameters on the system sensitivity and response. In particular, a systematic analysis of the whole absorption spectra has proved to be central.
- Open Access
- 1 September 2015
- Published by Walter de Gruyter GmbH in Nukleonika
- Vol. 60 (3) , 603-607
Effects of the pre-irradiation storage procedure on the dose response of a Fricke xylenol orange gel dosimeter
The Fricke xylenol orange (FX) gel system is a chemical dosimeter characterized by good sensitivity, linear dose response, tissue equivalence, no toxicity, easy preparation, reproducibility and low cost. Thanks to the presence of the gelatinous matrix, the system is particularly suitable to perform reliable 3D mapping of the absorbed dose spatial distribution via magnetic resonance imaging (MRI) or optical techniques. The aim of this work is to study in a systematic way the influence of the pre-irradiation storage procedure upon sensitivity, dose response stability and lifetime of use of a FX gel system made with gelatin from porcine skin subjected to homogeneous irradiation. For this purpose, different pre-irradiation storage procedures, in terms of temperature and duration of each storage step, were investigated. In order to evaluate the dose response stability, the optical analyses of the samples were performed up to 6 hours after irradiation. Moreover, the samples were irradiated at time intervals of 24 hours for up to 7 days after preparation in order to evaluate the system lifetime of use. Regardless of their thermal and temporal life, the samples show linear dose responses in the investigated dose range (3-24 Gy) and an increase of sensitivity with the time elapsed between preparation and irradiation. Among the three pre-irradiation storage procedures considered here, a procedure that provides the best dose response stability and lifetime of use was identified and recommended for further use. The analyzed dosimetric system possesses good properties that make it promising for medical application, particularly concerning the evaluation of pre-treatment plan quality assurance within the conformational external beam radiotherapy
- 1 September 2015
- Published by Walter de Gruyter GmbH in Nukleonika
- Vol. 60 (3) , 603-607
Open AccessEffects of the pre-irradiation storage procedure on the dose response of a Fricke xylenol orange gel dosimeter
The Fricke xylenol orange (FX) gel system is a chemical dosimeter characterized by good sensitivity, linear dose response, tissue equivalence, no toxicity, easy preparation, reproducibility and low cost. Thanks to the presence of the gelatinous matrix, the system is particularly suitable to perform reliable 3D mapping of the absorbed dose spatial distribution via magnetic resonance imaging (MRI) or optical techniques. The aim of this work is to study in a systematic way the influence of the pre-irradiation storage procedure upon sensitivity, dose response stability and lifetime of use of a FX gel system made with gelatin from porcine skin subjected to homogeneous irradiation. For this purpose, different pre-irradiation storage procedures, in terms of temperature and duration of each storage step, were investigated. In order to evaluate the dose response stability, the optical analyses of the samples were performed up to 6 hours after irradiation. Moreover, the samples were irradiated at time intervals of 24 hours for up to 7 days after preparation in order to evaluate the system lifetime of use. Regardless of their thermal and temporal life, the samples show linear dose responses in the investigated dose range (3-24 Gy) and an increase of sensitivity with the time elapsed between preparation and irradiation. Among the three pre-irradiation storage procedures considered here, a procedure that provides the best dose response stability and lifetime of use was identified and recommended for further use. The analyzed dosimetric system possesses good properties that make it promising for medical application, particularly concerning the evaluation of pre-treatment plan quality assurance within the conformational external beam radiotherapy