SFSolveig Fadnes

Solveig Fadnes

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Solveig Fadnes has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Left ventricular flow dynamics in preterm infants assessed with high frame rate echocardiography with blood speckle tracking

    by Koert de Waal, Edward Crendal, Solveig Fadnes, Kristian Sorensen, Siri Ann Nyrnes

    In this study, we explored a subgroup of newborns with high risk of cardiac failure during their intensive care stay, the very preterm infant. We present reference values for blood speckle-tracking-derived measures of cardiac efficiency. This data can assist in the development of further clinical applications for echo blood speckle tracking in preterm infants, such as predicting disease progression, monitoring treatments, and early diagnosis of adverse left ventricular (LV) remodeling.


  • Changes in left ventricular diastolic flow dynamics in the neonatal transition period and beyond

    by Kristian Sørensen, Solveig Fadnes, Tor Åge Myklebust, Lasse Løvstakken, Luc Mertens, Siri Ann Nyrnes

    Assessment of left ventricular flow dynamics is highly feasible using high-frame rate echocardiography-based blood speckle tracking. In healthy newborns, left ventricular diastolic kinetic energy, energy loss, and vorticity significantly change during the first weeks, stabilizing after 6–8 wk, whereas intraventricular pressure difference continues to increase until 6 mo of age. These findings indicate that intraventricular flow dynamics can describe changes in cardiac physiology contributing to normal postnatal cardiovascular adaptation, maturation, and function.


  • Open Access

    The 3D Estimation of Mechanical Wave Velocities in the Heart: Methods and Insights

    by Mohammad Mohajery, Sebastien Salles, Torvald Espeland, Morten Smedsrud Wigen, Solveig Fadnes, Lasse Lovstakken

    The velocity of mechanical waves (MW) in the heart reflects myocardial tissue properties. Different wave velocity estimation methods have been proposed, using the slope of the wave projection in M-mode, or based on the gradient of the time-of-flight (TOF) map (gradient method). In this work, we compare these methods using a simulation and 3D wave propagation in vivo. Waves were detected using both clutter filter wave imaging (CFWI) and tissue Doppler imaging (TDI). The effect of pipeline parameters on velocity estimation was studied. Finally, an in vivo investigation was made for healthy controls and patients with aortic stenosis. When the wave propagation was mainly in-plane, all methods yielded similar results, verified using both simulations and in vivo data. However, velocity overestimation occurred due to misalignment between the M-line and the wave propagation direction, and for wave-view misalignment when using the 2D gradient method. The gradient method was sensitive to processing parameters, where smoothing of the TOF map also led to an overestimation of the wave velocities. For our data, CFWI provided the most robust results, however, the choice of filter cutoff influenced the output, which became similar to TDI for high cutoff velocities. Our study shows that the gradient method can provide similar results as the M-mode slope when the wave propagation is aligned in-plane, and further provide localized wave velocity estimates in 2D and 3D, limited by smoothing requirements. This can be advantageous for mapping heterogeneous tissue properties, and the method can provide valuable clinical insight in the future.


  • Open Access

    Intraventricular Pressure Difference by Blood Speckle Tracking - Invasive Validation and Clinical Application

    by Kristian Sørensen, Solveig Fadnes, Wadi Mawad, Matthew Henry, Hans Martin Flade, Andreas Østvik, Tor Åge Myklebust, Idar Kirkeby-Garstad, Lasse Løvstakken, Luc Mertens, et al.

    Background Early diastolic relaxation creates an intraventricular pressure difference (IVPD) and resulting diastolic suction. Non-invasive estimation by echocardiographic techniques would allow to clinically evaluate this IVPD as an important component of ventricular filling. Recently, Blood Speckle Tracking (BST) echocardiography was introduced, allowing two-dimensional assessment of ventricular flow dynamics. Mitral inflow BST data can be used to estimate IVPD. The aims of the current study were to evaluate the accuracy of BST-based IVPD estimation compared to invasive pressure measurements in an in vivo animal model, and to clinically apply the method by comparing IVPD in children with univentricular hearts (UVH) and healthy controls. Methods The accuracy of BST-based IVPD-estimates was assessed in an open-chest porcine model, comparing BST-based IVPD with simultaneous repeated invasive pressure measurements in six pigs using micromanometer catheters. BST-based IVPD assessment was performed in 120 healthy controls and 44 patients with UVH < 18 years of age. Total IVPD (from base to apex) and apical IVPD (from the apical 2/3 of the ventricle) during early diastolic filling of the systemic ventricle was compared between patients with UVH and healthy controls. Results The validation in pigs included 103 measurements, demonstrating a mean difference of - 0.01mmHg (p=0.33) and high correlation (r = 0.95, p-value < 0.001) between IVPD from BST (-1.31 ± 0.28 mmHg) and invasive measurements (-1.30 ± 0.31 mmHg). In the pediatric patients, age range 2 days-17.76 years, feasibility was 96% in controls and 88.6% in UVH patients. Total and apical IVPD were significantly higher in controls compared to UVH (-1.82 vs -0.88 mmHg and -0.63 vs -0.33 mmHg, p < 0.001). Variability was low with intraclass correlation coefficients of 0.99/0.96 (interobserver) and 0.98/0.99 (intraobserver) for total and apical IVPD respectively. Conclusions BST echocardiography provides accurate estimation of early diastolic IVPD. When clinically applied in children, we found high feasibility and reproducibility. IVPD was significantly lower in children with UVH compared to controls suggesting lower diastolic suction which can impact overall filling dynamics. What is new Blood speckle tracking echocardiography provides non-invasive estimation of intraventricular pressure difference in early diastole using two-dimensional blood flow velocities Intraventricular pressure difference based on blood speckle tracking is highly feasible, accurate and reproducible Blood speckle tracking demonstrates significantly reduced intraventricular pressure difference in early diastole in children with univentricular hearts indicating impaired relaxation and suction in these patients What are the clinical implications Intraventricular pressure difference based on blood speckle tracking is a novel and potential sensitive echocardiographic parameter to describe early diastolic ventricular relaxation and diastolic function in children with univentricular hearts Blood speckle tracking could improve assessment of diastolic function in children with congenital heart disease Non-invasive estimation of intraventricular pressure difference based on blood speckle tracking could improve assessment of diastolic function both in children and adults with heart disease


  • Open Access

    Automated 3D Velocity Estimation of Natural Mechanical Wave Propagation in the Myocardium

    by Mohammad Mohajery, Sebastien Salles, Torvald Espeland, Solveig Fadnes, Lasse Lovstakken

    The mechanical wave (MW) propagation velocity in the heart is related to the tissue stiffness and its measurement mainly relies on manual evaluation of the 1D wave projection. This study presents an automated method for 3D wave visualization and velocity estimation in the heart using 3D ultrasound imaging of the left ventricle (LV). High-quality (HQ, 19 vps) and high-frame-rate (HFR, 823 vps) volumes were acquired. Deep learning models automatically segmented the LV and extracted the apical standard views from the HQ data which were used to derive the anatomical M-lines and myocardial segmentation. The clutter filter wave imaging (CFWI) and tissue Doppler imaging (TDI) generated wave propagation maps from HFR data, and the aortic valve closure (AVC) and atrial contraction/kick (AK) waves were automatically detected. LV segmentation and anatomical M-lines were used for 3D wave propagation extraction and its 1D projection, respectively. The 1D wave propagation velocity was determined through automatic slope detection, while the 3D velocity map was derived from the gradient of the time-of-flight (TOF) map. Results showed varying 1D velocity across views and myocardial regions, with the AVC propagation velocity surpassing that of the AK wave. The pipeline remained stable and generated results consistent with expert measurements. Comparing 3D and 1D propagation highlighted errors from 1D projection and demonstrated the benefits of the 3D method in assessing regional velocities and the validity of the 1D approach. This study demonstrated an automatic evaluation of 3D MW propagation velocities in the entire LV, leading to improved accuracy and standardized measurements of myocardial tissue properties.


  • Quantitative Vascular Blood Flow Imaging: A Comparison of Vector Velocity Estimation Schemes

    by Ingvild Kinn Ekroll, Morten Wigen, Solveig Fadnes, Jorgen Avdal

    The recently developed flowline based ultrasound simulation tool FLUST was used to simulate multiple realizations of echo data from the systolic flow field of a carotid artery bifurcation. The data was used to quantify the bias and standard deviation of three different vector velocity estimators in every point of the image, using different acquisition setups and a range of SNR values. The results showed that in high SNR conditions, both cross-correlation based (speckle tracking) and autocorrelation based velocity estimation techniques performed well in terms of bias, but that speckle tracking yielded a higher standard deviation. In poor SNR conditions, a consistent negative bias was found when using speckle tracking, especially for the v x component. The negative bias increased with decreasing SNR. The autocorrelation based velocity estimators showed a more consistent performance over a large range of SNR values. A setup where axial resolution (pulse length) and frame rate was traded for increased SNR and lateral resolution (coherent compounding based on two transmit angles) was found to increase the performance of the cross-correlation based technique. When using this balanced setup in high SNR conditions, the cross-correlation based technique yielded a slightly lower median bias in the v x component than the autocorrelation based technique. Increasing the pulse length further did not improve the performance of the autocorrelation based estimator.


  • 4-D Intracardiac Ultrasound Vector Flow Imaging–Feasibility and Comparison to Phase-Contrast MRI

    by Morten Smedsrud Wigen, Solveig Fadnes, Alfonso Rodriguez-Molares, Tore Bjastad, Marius Eriksen, Knut Haakon Stensath, Asbjorn Stoylen, Lasse Lovstakken

    In vivo characterization of intracardiac blood velocity vector fields may provide new clinical information but is currently not available for bedside evaluation. In this paper, 4-D vector flow imaging for intracardiac flow assessment is demonstrated using a clinical ultrasound (US) system and a matrix array transducer, without the use of contrast agent. Two acquisition schemes were developed, one for full volumetric coverage of the left ventricle (LA) at 50 vps and a 3-D thick-slice setup with continuous frame acquisition (4000 vps), both utilizing ECG-gating. The 3-D vector velocity estimates were obtained using a novel method combining phase and envelope information. In vitro validation in a rotating tissue-mimicking phantom revealed velocity estimates in compliance with the ground truth, with a linear regression slope of 0.80, 0.77, and 1.03 for the x, y, and z velocity components, and with standard deviations of 2.53, 3.19, and 0.95 cm/s, respectively. In vivo measurements in a healthy LV showed good agreement with PC-MRI. Quantitative analysis of energy loss (EL) and kinetic energy (KE) further showed similar trends, with peak KE at 1.5 and 2.4 mJ during systole and 3.6 and 3.1 mJ for diastole for US and PC-MRI. Similar for EL, 0.15-0.2 and 0.7 mW was found during systole and 0.6 and 0.7 mW during diastole, for US and PC-MRI, respectively. Overall, a potential for US as a future modality for 4D cardiac vector flow imaging was demonstrated, which will be further evaluated in clinical studies.


  • Open Access

    In Vivo Intracardiac Vector Flow Imaging Using Phased Array Transducers for Pediatric Cardiology

    by Solveig Fadnes, Morten Smedsrud Wigen, Siri Ann Nyrnes, Lasse Lovstakken

    Two-dimensional blood speckle tracking (ST) has shown promise for measuring complex flow patterns in neonatal hearts using linear arrays and high-frame-rate plane wave imaging. For general pediatric applications, however, the need for phased array probes emerges due to the limited intercostal acoustic window available. In this paper, a clinically approved real-time duplex imaging setup with phased array probes was used to investigate the potential of blood ST for the 2-D vector flow imaging of children with congenital heart disease. To investigate transmit beam pattern and tracking accuracy, straight tubes with parabolic flow were simulated at three depths (4.5, 7, and 9.5 cm). Due to the small aperture available, diffraction effects could be observed when approaching 10 cm, which limited the number of parallel receive beams that could be utilized. Moving to (slightly) diverging beams was shown to solve this issue at the expense of a loss in signal-to-noise ratio. To achieve consistent estimates, a forward-backward tracking scheme was introduced to avoid measurement bias occurring due to tracking kernel averaging artifacts at flow domain boundaries. Promising results were observed for depths <;10 cm in two pediatric patients, where complex cardiac flow patterns could be estimated and visualized. As a loss in penetration compared with color flow imaging is expected, a larger clinical study is needed to establish the clinical feasibility of this approach.


  • Clutter filtering influence on blood velocity estimation using speckle tracking

    by Solveig Fadnes, Steinar Bjærum, Hans Torp, Lasse Lovstakken

    Blood speckle tracking has shown potential for solving the angle-dependency limitation in color flow imaging. However, as clutter filtering is still Doppler-based, flow velocities at near-perpendicular beam-to-flow angles can be severely attenuated. It is shown that the clutter filter also alters the speckle appearance through a decrease in the lateral imaging bandwidth, leading to poorer lateral resolution and thus tracking performance. Interestingly, at perpendicular beam-to-flow angles lateral band-pass characteristics are inferred, and the resulting lateral amplitude modulation could help improve tracking estimates. Simulations and flow phantom experiments showed that substantially improved results could be achieved by utilizing time-variant clutter filters (e.g., polynomial regression filters) despite the inherent decorrelation inferred by these filters, but only for higher ensemble sizes (N > 36). We found that, compared with color flow imaging, speckle tracking could yield consistent estimates well below the clutter filter cutoff, but with a higher variance attributed to the low signalto- noise ratio inferred by filter attenuation. Overall, provided that a low f-number and high ensemble lengths (N approx. > 36) can be used, speckle tracking can consistently provide angle- independent flow velocity estimates, limited only by a lower bound on the flow velocity itself.