4-D Intracardiac Ultrasound Vector Flow Imaging–Feasibility and Comparison to Phase-Contrast MRI
- 6 June 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 37 (12) , 2619-2629
Abstract
In vivo characterization of intracardiac blood velocity vector fields may provide new clinical information but is currently not available for bedside evaluation. In this paper, 4-D vector flow imaging for intracardiac flow assessment is demonstrated using a clinical ultrasound (US) system and a matrix array transducer, without the use of contrast agent. Two acquisition schemes were developed, one for full volumetric coverage of the left ventricle (LA) at 50 vps and a 3-D thick-slice setup with continuous frame acquisition (4000 vps), both utilizing ECG-gating. The 3-D vector velocity estimates were obtained using a novel method combining phase and envelope information. In vitro validation in a rotating tissue-mimicking phantom revealed velocity estimates in compliance with the ground truth, with a linear regression slope of 0.80, 0.77, and 1.03 for the x, y, and z velocity components, and with standard deviations of 2.53, 3.19, and 0.95 cm/s, respectively. In vivo measurements in a healthy LV showed good agreement with PC-MRI. Quantitative analysis of energy loss (EL) and kinetic energy (KE) further showed similar trends, with peak KE at 1.5 and 2.4 mJ during systole and 3.6 and 3.1 mJ for diastole for US and PC-MRI. Similar for EL, 0.15-0.2 and 0.7 mW was found during systole and 0.6 and 0.7 mW during diastole, for US and PC-MRI, respectively. Overall, a potential for US as a future modality for 4D cardiac vector flow imaging was demonstrated, which will be further evaluated in clinical studies.Keywords
Funding Information
- Norges Forskningsråd (230455)
This publication has 28 references indexed in Scilit:
- 4D Blood Flow Reconstruction Over the Entire Ventricle From Wall Motion and Blood Velocity Derived From Ultrasound DataIEEE Transactions on Medical Imaging, 2015
- Spatiotemporal Clutter Filtering of Ultrafast Ultrasound Data Highly Increases Doppler and fUltrasound SensitivityIEEE Transactions on Medical Imaging, 2015
- 4D flow cardiovascular magnetic resonance consensus statementJournal of Cardiovascular Magnetic Resonance, 2015
- Improved Myocardial Motion Estimation Combining Tissue Doppler and B-Mode Echocardiographic ImagesIEEE Transactions on Medical Imaging, 2014
- Tissue Doppler Imaging Optical Flow (TDIOF): A Combined B-Mode and Tissue Doppler Approach for Cardiac Motion Estimation in Echocardiographic ImagesIEEE Transactions on Biomedical Engineering, 2014
- 4D flow MRIJournal of Magnetic Resonance Imaging, 2012
- Multiplanar Visualization of Blood Flow Using Echocardiographic Particle Imaging VelocimetryJACC: Cardiovascular Imaging, 2012
- Emerging Trends in CV Flow VisualizationJACC: Cardiovascular Imaging, 2012
- Removal of local and biased global maxima in intensity-based registrationMedical Image Analysis, 2007
- A new estimator for vector velocity estimation [medical ultrasonics]IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2001