Morten Smedsrud Wigen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Morten Smedsrud Wigen has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Solveig Fadnes
Department of Circulation and Medical Imaging (ISB), Norwegian University of Science and Technology (NTNU), Trondheim, Norway
3 shared publications Lasse Lovstakken
Centre for Innovative Ultrasound Solutions, Dept. Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway
2 shared publications- Lasse Lovstakken
Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway
2 shared publications - Abigail Swillens
IBiTech-bioMMeda, Ghent University, Ghent, Belgium
1 shared publication - Alfonso Rodriguez-Molares
Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway
1 shared publication Asbjorn Stoylen
Department of Circulation and Medical Imaging, NTNU, Trondheim, Norway
1 shared publication
Latest Publications
- Open Access
- 8 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 4, 177-190
The 3D Estimation of Mechanical Wave Velocities in the Heart: Methods and Insights
The velocity of mechanical waves (MW) in the heart reflects myocardial tissue properties. Different wave velocity estimation methods have been proposed, using the slope of the wave projection in M-mode, or based on the gradient of the time-of-flight (TOF) map (gradient method). In this work, we compare these methods using a simulation and 3D wave propagation in vivo. Waves were detected using both clutter filter wave imaging (CFWI) and tissue Doppler imaging (TDI). The effect of pipeline parameters on velocity estimation was studied. Finally, an in vivo investigation was made for healthy controls and patients with aortic stenosis. When the wave propagation was mainly in-plane, all methods yielded similar results, verified using both simulations and in vivo data. However, velocity overestimation occurred due to misalignment between the M-line and the wave propagation direction, and for wave-view misalignment when using the 2D gradient method. The gradient method was sensitive to processing parameters, where smoothing of the TOF map also led to an overestimation of the wave velocities. For our data, CFWI provided the most robust results, however, the choice of filter cutoff influenced the output, which became similar to TDI for high cutoff velocities. Our study shows that the gradient method can provide similar results as the M-mode slope when the wave propagation is aligned in-plane, and further provide localized wave velocity estimates in 2D and 3D, limited by smoothing requirements. This can be advantageous for mapping heterogeneous tissue properties, and the method can provide valuable clinical insight in the future.
- 8 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 4, 177-190
Open AccessThe 3D Estimation of Mechanical Wave Velocities in the Heart: Methods and Insights
The velocity of mechanical waves (MW) in the heart reflects myocardial tissue properties. Different wave velocity estimation methods have been proposed, using the slope of the wave projection in M-mode, or based on the gradient of the time-of-flight (TOF) map (gradient method). In this work, we compare these methods using a simulation and 3D wave propagation in vivo. Waves were detected using both clutter filter wave imaging (CFWI) and tissue Doppler imaging (TDI). The effect of pipeline parameters on velocity estimation was studied. Finally, an in vivo investigation was made for healthy controls and patients with aortic stenosis. When the wave propagation was mainly in-plane, all methods yielded similar results, verified using both simulations and in vivo data. However, velocity overestimation occurred due to misalignment between the M-line and the wave propagation direction, and for wave-view misalignment when using the 2D gradient method. The gradient method was sensitive to processing parameters, where smoothing of the TOF map also led to an overestimation of the wave velocities. For our data, CFWI provided the most robust results, however, the choice of filter cutoff influenced the output, which became similar to TDI for high cutoff velocities. Our study shows that the gradient method can provide similar results as the M-mode slope when the wave propagation is aligned in-plane, and further provide localized wave velocity estimates in 2D and 3D, limited by smoothing requirements. This can be advantageous for mapping heterogeneous tissue properties, and the method can provide valuable clinical insight in the future.
- Open Access
- 1 April 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 146, 105358
Comparison of ultrasound vector flow imaging and CFD simulations with PIV measurements of flow in a left ventricular outflow trackt phantom - Implications for clinical use and in silico studies
- 1 April 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 146, 105358
Open AccessComparison of ultrasound vector flow imaging and CFD simulations with PIV measurements of flow in a left ventricular outflow trackt phantom - Implications for clinical use and in silico studies
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Quantitative Vascular Blood Flow Imaging: A Comparison of Vector Velocity Estimation Schemes
The recently developed flowline based ultrasound simulation tool FLUST was used to simulate multiple realizations of echo data from the systolic flow field of a carotid artery bifurcation. The data was used to quantify the bias and standard deviation of three different vector velocity estimators in every point of the image, using different acquisition setups and a range of SNR values. The results showed that in high SNR conditions, both cross-correlation based (speckle tracking) and autocorrelation based velocity estimation techniques performed well in terms of bias, but that speckle tracking yielded a higher standard deviation. In poor SNR conditions, a consistent negative bias was found when using speckle tracking, especially for the v x component. The negative bias increased with decreasing SNR. The autocorrelation based velocity estimators showed a more consistent performance over a large range of SNR values. A setup where axial resolution (pulse length) and frame rate was traded for increased SNR and lateral resolution (coherent compounding based on two transmit angles) was found to increase the performance of the cross-correlation based technique. When using this balanced setup in high SNR conditions, the cross-correlation based technique yielded a slightly lower median bias in the v x component than the autocorrelation based technique. Increasing the pulse length further did not improve the performance of the autocorrelation based estimator.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Quantitative Vascular Blood Flow Imaging: A Comparison of Vector Velocity Estimation Schemes
The recently developed flowline based ultrasound simulation tool FLUST was used to simulate multiple realizations of echo data from the systolic flow field of a carotid artery bifurcation. The data was used to quantify the bias and standard deviation of three different vector velocity estimators in every point of the image, using different acquisition setups and a range of SNR values. The results showed that in high SNR conditions, both cross-correlation based (speckle tracking) and autocorrelation based velocity estimation techniques performed well in terms of bias, but that speckle tracking yielded a higher standard deviation. In poor SNR conditions, a consistent negative bias was found when using speckle tracking, especially for the v x component. The negative bias increased with decreasing SNR. The autocorrelation based velocity estimators showed a more consistent performance over a large range of SNR values. A setup where axial resolution (pulse length) and frame rate was traded for increased SNR and lateral resolution (coherent compounding based on two transmit angles) was found to increase the performance of the cross-correlation based technique. When using this balanced setup in high SNR conditions, the cross-correlation based technique yielded a slightly lower median bias in the v x component than the autocorrelation based technique. Increasing the pulse length further did not improve the performance of the autocorrelation based estimator.
- 6 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 37 (12) , 2619-2629
4-D Intracardiac Ultrasound Vector Flow Imaging–Feasibility and Comparison to Phase-Contrast MRI
In vivo characterization of intracardiac blood velocity vector fields may provide new clinical information but is currently not available for bedside evaluation. In this paper, 4-D vector flow imaging for intracardiac flow assessment is demonstrated using a clinical ultrasound (US) system and a matrix array transducer, without the use of contrast agent. Two acquisition schemes were developed, one for full volumetric coverage of the left ventricle (LA) at 50 vps and a 3-D thick-slice setup with continuous frame acquisition (4000 vps), both utilizing ECG-gating. The 3-D vector velocity estimates were obtained using a novel method combining phase and envelope information. In vitro validation in a rotating tissue-mimicking phantom revealed velocity estimates in compliance with the ground truth, with a linear regression slope of 0.80, 0.77, and 1.03 for the x, y, and z velocity components, and with standard deviations of 2.53, 3.19, and 0.95 cm/s, respectively. In vivo measurements in a healthy LV showed good agreement with PC-MRI. Quantitative analysis of energy loss (EL) and kinetic energy (KE) further showed similar trends, with peak KE at 1.5 and 2.4 mJ during systole and 3.6 and 3.1 mJ for diastole for US and PC-MRI. Similar for EL, 0.15-0.2 and 0.7 mW was found during systole and 0.6 and 0.7 mW during diastole, for US and PC-MRI, respectively. Overall, a potential for US as a future modality for 4D cardiac vector flow imaging was demonstrated, which will be further evaluated in clinical studies.
- 6 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 37 (12) , 2619-2629
4-D Intracardiac Ultrasound Vector Flow Imaging–Feasibility and Comparison to Phase-Contrast MRI
In vivo characterization of intracardiac blood velocity vector fields may provide new clinical information but is currently not available for bedside evaluation. In this paper, 4-D vector flow imaging for intracardiac flow assessment is demonstrated using a clinical ultrasound (US) system and a matrix array transducer, without the use of contrast agent. Two acquisition schemes were developed, one for full volumetric coverage of the left ventricle (LA) at 50 vps and a 3-D thick-slice setup with continuous frame acquisition (4000 vps), both utilizing ECG-gating. The 3-D vector velocity estimates were obtained using a novel method combining phase and envelope information. In vitro validation in a rotating tissue-mimicking phantom revealed velocity estimates in compliance with the ground truth, with a linear regression slope of 0.80, 0.77, and 1.03 for the x, y, and z velocity components, and with standard deviations of 2.53, 3.19, and 0.95 cm/s, respectively. In vivo measurements in a healthy LV showed good agreement with PC-MRI. Quantitative analysis of energy loss (EL) and kinetic energy (KE) further showed similar trends, with peak KE at 1.5 and 2.4 mJ during systole and 3.6 and 3.1 mJ for diastole for US and PC-MRI. Similar for EL, 0.15-0.2 and 0.7 mW was found during systole and 0.6 and 0.7 mW during diastole, for US and PC-MRI, respectively. Overall, a potential for US as a future modality for 4D cardiac vector flow imaging was demonstrated, which will be further evaluated in clinical studies.
- 1 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Model-based estimation of intra-cardiac blood flow velocities using an unscented Kalman filter
The measurement of 2D blood flow velocities using an angle-independent speckle tracking (ST) approach has shown promise as a clinical tool for quantification of cardiovascular deficiencies. However, the ST estimator can be highly corrupted by noise in regions of reduced signal-to-noise ratio (SNR). This work proposes a model-based blood velocity estimation technique which combines ST measurements and color flow imaging (CFI) measurements with a blood flow model based on the Navier-Stokes equations for fluid flow, yielding improved velocity estimates by adaptively weighting the measurements and correcting for estimator artifacts such as Doppler aliasing. Validation with simulated measurements from a computational fluid dynamics (CFD) simulated flow field show an overall improvement in root mean square (RMS) error compared to the ST and CFI measurements, also with spatiotemporal averaging. In vivo examples are included showing that the model-based filter is able to provide robust angle-independent velocity estimates with less need for spatiotemporal averaging, preserving spatial details of the flow field.
- 1 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Model-based estimation of intra-cardiac blood flow velocities using an unscented Kalman filter
The measurement of 2D blood flow velocities using an angle-independent speckle tracking (ST) approach has shown promise as a clinical tool for quantification of cardiovascular deficiencies. However, the ST estimator can be highly corrupted by noise in regions of reduced signal-to-noise ratio (SNR). This work proposes a model-based blood velocity estimation technique which combines ST measurements and color flow imaging (CFI) measurements with a blood flow model based on the Navier-Stokes equations for fluid flow, yielding improved velocity estimates by adaptively weighting the measurements and correcting for estimator artifacts such as Doppler aliasing. Validation with simulated measurements from a computational fluid dynamics (CFD) simulated flow field show an overall improvement in root mean square (RMS) error compared to the ST and CFI measurements, also with spatiotemporal averaging. In vivo examples are included showing that the model-based filter is able to provide robust angle-independent velocity estimates with less need for spatiotemporal averaging, preserving spatial details of the flow field.