Sujata Bhowmick
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sujata Bhowmick has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Sethupathy Subramanian
Department of Physics and Astronomy, University of Notre Dame, Notre Dame, IN, USA
3 shared publications Loganathan Umanand
Department of Electronic Systems Engineering, Indian Institute of Science, Bangalore, 560012, India
2 shared publications- Anil Kumar Adapa
Electrical Engineering, Indian Institute of Science, 29120 Bangalore, Karnataka India 560012
1 shared publication - Baquer Mazhari
Department of Electrical Engineering, IIT Kanpur, Kanpur, India
1 shared publication - Loganathan Umanand
Interdisciplinary Center for Energy Research, Indian Institute of Science, Bangalore, India
1 shared publication - Udaya Kumar
Indian Insititute of Science, Department of Electrical Engineering, Bengaluru, Karnataka, India
1 shared publication
Latest Publications
- 14 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 59 (9) , 1-10
The Source-Stabilized Galerkin Formulation for Linear Moving Conductor Problems With Edge Elements
The phenomenon of linear motion of conductor in a magnetic field is commonly found in electric machineries such as, electromagnetic brakes, linear induction motor, electromagnetic flowmeter etc. The design and analysis of the same requires an accurate evaluation of induced currents and the associated reaction magnetic fields. The finite element method is a generally employed numerical technique for this purpose. However, it needs stabilization techniques to provide an accurate solution. In this work, such a stabilization technique is developed for the edge elements. The stability and hence the accuracy is brought in by a suitable representation of the source term. The stability and accuracy of the proposed scheme is first shown analytically and then demonstrated with the help of 2D and 3D simulations. The proposed scheme would require a graded regular mesh along the direction of motion.
- 14 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 59 (9) , 1-10
The Source-Stabilized Galerkin Formulation for Linear Moving Conductor Problems With Edge Elements
The phenomenon of linear motion of conductor in a magnetic field is commonly found in electric machineries such as, electromagnetic brakes, linear induction motor, electromagnetic flowmeter etc. The design and analysis of the same requires an accurate evaluation of induced currents and the associated reaction magnetic fields. The finite element method is a generally employed numerical technique for this purpose. However, it needs stabilization techniques to provide an accurate solution. In this work, such a stabilization technique is developed for the edge elements. The stability and hence the accuracy is brought in by a suitable representation of the source term. The stability and accuracy of the proposed scheme is first shown analytically and then demonstrated with the help of 2D and 3D simulations. The proposed scheme would require a graded regular mesh along the direction of motion.
- 30 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal on Multiscale and Multiphysics Computational Techniques
- Vol. 7, 220-227
A Stable Weighted Residual Finite Element Formulation for the Simulation of Linear Moving Conductor Problems
The finite element method is one of the widely employed numerical techniques in electrical engineering for the study of electric and magnetic fields. When applied to the moving conductor problems, the finite element method is known to have numerical oscillations in the solution. To resolve this, the upwinding techniques, which are developed for the transport equation are borrowed and directly employed for the magnetic induction equation. In this work, an alternative weighted residual formulation is explored for the simulation of the linear moving conductor problems. The formulation is parameter-free and the stability of the formulation is analytically studied for the 1D version of the moving conductor problem. Then the rate of convergence and the accuracy are illustrated with the help of several test cases in 1D as well as 2D. Subsequently, the stability of the formulation is demonstrated with a 3D moving conductor simulation.
- 30 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal on Multiscale and Multiphysics Computational Techniques
- Vol. 7, 220-227
A Stable Weighted Residual Finite Element Formulation for the Simulation of Linear Moving Conductor Problems
The finite element method is one of the widely employed numerical techniques in electrical engineering for the study of electric and magnetic fields. When applied to the moving conductor problems, the finite element method is known to have numerical oscillations in the solution. To resolve this, the upwinding techniques, which are developed for the transport equation are borrowed and directly employed for the magnetic induction equation. In this work, an alternative weighted residual formulation is explored for the simulation of the linear moving conductor problems. The formulation is parameter-free and the stability of the formulation is analytically studied for the 1D version of the moving conductor problem. Then the rate of convergence and the accuracy are illustrated with the help of several test cases in 1D as well as 2D. Subsequently, the stability of the formulation is demonstrated with a 3D moving conductor simulation.
- 27 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 58 (1) , 1-8
On Overcoming the Transverse Boundary Error of the SU/PG Scheme for Moving Conductor Problems
Conductor moving in magnetic field is quite common in electrical equipment. The numerical simulation of such problem is vital in their design and analysis of electrical equipment. The Galerkin finite element method (GFEM) is a commonly employed simulation tool, nonetheless, due to its inherent numerical instability at higher velocities, the GFEM requires upwinding techniques to handle moving conductor problems. The streamline upwinding/Petrov–Galerkin (SU/PG) scheme is a widely acknowledged upwinding technique, despite its error peaking at the transverse boundary. This error at the transverse boundary is found to be leading to non-physical solutions. Several remedies have been suggested in the allied fluid dynamics literature, which employs non-linear, iterative techniques. The present work attempts to address this issue, by retaining the computational efficiency of the GFEM. By suitable analysis, it is shown that the source of the problem can be attributed to the Coulomb’s gauge. Therefore, to solve the problem, the Coulomb’s gauge is taken out from the formulation and the associated weak form is derived. The effectiveness of this technique is demonstrated with pertinent numerical results.
- 27 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 58 (1) , 1-8
On Overcoming the Transverse Boundary Error of the SU/PG Scheme for Moving Conductor Problems
Conductor moving in magnetic field is quite common in electrical equipment. The numerical simulation of such problem is vital in their design and analysis of electrical equipment. The Galerkin finite element method (GFEM) is a commonly employed simulation tool, nonetheless, due to its inherent numerical instability at higher velocities, the GFEM requires upwinding techniques to handle moving conductor problems. The streamline upwinding/Petrov–Galerkin (SU/PG) scheme is a widely acknowledged upwinding technique, despite its error peaking at the transverse boundary. This error at the transverse boundary is found to be leading to non-physical solutions. Several remedies have been suggested in the allied fluid dynamics literature, which employs non-linear, iterative techniques. The present work attempts to address this issue, by retaining the computational efficiency of the GFEM. By suitable analysis, it is shown that the source of the problem can be attributed to the Coulomb’s gauge. Therefore, to solve the problem, the Coulomb’s gauge is taken out from the formulation and the associated weak form is derived. The effectiveness of this technique is demonstrated with pertinent numerical results.
- 6 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (4) , 3058-3068
Low-Frequency DC-Link Capacitor Current Mitigation in Reduced Switch Count Single-Phase to Three-Phase Converter
This work proposes an approach to mitigate the dc-link double-frequency ripple current in a 3-leg single-phase to three-phase converter. This work is based on an economical Active Phase Converter (APC) utilizing a fewer number of switches. The presented approach does not demand either bulky dc side passive ripple filter or additional semiconductor switches typically employed in active dc-link ripple filters. The proposed method introduces an appropriately selected ac capacitor into the APC circuit, also known as AC-APC, which mitigates the dc-link double-frequency ripple. Reduction of power loss in the Equivalent Series Resistor (ESR) of the dc-bus capacitor associated with the dc-link double-frequency ripple current enhances the lifetime of electrolytic capacitor typically employed in the APC. At full load, the dc-link current at double-fundamental frequency is reduced by more than 50% and the temperature rise in the dc-bus electrolytic capacitors is reduced by more than 30%. The proposed method is validated experimentally using a laboratory prototype APC. Theoretical and simulation results of the dc-link double-frequency current are in close agreement with the experimental findings.
- 6 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (4) , 3058-3068
Low-Frequency DC-Link Capacitor Current Mitigation in Reduced Switch Count Single-Phase to Three-Phase Converter
This work proposes an approach to mitigate the dc-link double-frequency ripple current in a 3-leg single-phase to three-phase converter. This work is based on an economical Active Phase Converter (APC) utilizing a fewer number of switches. The presented approach does not demand either bulky dc side passive ripple filter or additional semiconductor switches typically employed in active dc-link ripple filters. The proposed method introduces an appropriately selected ac capacitor into the APC circuit, also known as AC-APC, which mitigates the dc-link double-frequency ripple. Reduction of power loss in the Equivalent Series Resistor (ESR) of the dc-bus capacitor associated with the dc-link double-frequency ripple current enhances the lifetime of electrolytic capacitor typically employed in the APC. At full load, the dc-link current at double-fundamental frequency is reduced by more than 50% and the temperature rise in the dc-bus electrolytic capacitors is reduced by more than 30%. The proposed method is validated experimentally using a laboratory prototype APC. Theoretical and simulation results of the dc-link double-frequency current are in close agreement with the experimental findings.
- 30 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 7 (3) , 2041-2056
A High-Performance Dynamic Controller For an Active Power Decoupler With AC-Side Storage Element
The instantaneous power in a single phase system pulsates at double the supply frequency. With the effective use of storage element, the electrolytic capacitor placed at the dc bus, can be replaced by film capacitors, thereby improving the converter lifespan. Active power decoupling (APD), using an extra set of switches aims to attain the same. Recently a promising APD topology has been reported, offering lesser number of switches, as well as, lesser stress on the switches for a wide range of power factor. However, the control of that converter poses a challenge as it has more number of states than the independent control variables. This paper focuses on the control aspect of the topology. It is shown that controlling two out of three states guarantees the overall system performance at steady state. Also, ripple power in the dc bus is controlled in a closed loop fashion so as to handle model uncertainty and thereby improve the steady state performance. Furthermore, the solution to suppress the harmonic power, reflected on to the dc bus, under polluted grid condition is provided. The simulation and experimental results are presented supporting the analysis and design of the controller structure.
- 30 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 7 (3) , 2041-2056
A High-Performance Dynamic Controller For an Active Power Decoupler With AC-Side Storage Element
The instantaneous power in a single phase system pulsates at double the supply frequency. With the effective use of storage element, the electrolytic capacitor placed at the dc bus, can be replaced by film capacitors, thereby improving the converter lifespan. Active power decoupling (APD), using an extra set of switches aims to attain the same. Recently a promising APD topology has been reported, offering lesser number of switches, as well as, lesser stress on the switches for a wide range of power factor. However, the control of that converter poses a challenge as it has more number of states than the independent control variables. This paper focuses on the control aspect of the topology. It is shown that controlling two out of three states guarantees the overall system performance at steady state. Also, ripple power in the dc bus is controlled in a closed loop fashion so as to handle model uncertainty and thereby improve the steady state performance. Furthermore, the solution to suppress the harmonic power, reflected on to the dc bus, under polluted grid condition is provided. The simulation and experimental results are presented supporting the analysis and design of the controller structure.
- 17 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 6 (4) , 1921-1931
Design and Analysis of the Low Device Stress Active Power Decoupling for Single-Phase Grid Connection for a Wide Range of Power Factor
Single-phase power converters suffer from the double frequency power pulsation. In voltage source inverters, the dc bus capacitor is designed to supply this double frequency current. The stringent dc bus voltage ripple specifications call for larger capacitance. This implies larger electrolytic capacitors. However, the electrolytic capacitor suffers from short-term life span, which consequently brings down the lifetime of the converter. As an alternative, active power decoupling (APD) ensures significant reduction in dc buffering requirement, thereby reducing the bus capacitance. This can make use of the film capacitors with better lifespan. In this paper, an APD scheme is designed and developed for the grid-connected system. Another important feature of the proposed scheme is that, it reduces the stress on the switches significantly while compared with existing APD solutions for all load power factors. The system is analyzed further to arrive at APD control conditions including the effect of grid filter inductance. The simulation and experimentation have been done to validate the proposed method. Additionally, the stress on the switches as a function of grid filter inductance is predicted theoretically and verified practically. The average stress on the switches is shown to be lesser than the existing solutions.
- 17 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 6 (4) , 1921-1931
Design and Analysis of the Low Device Stress Active Power Decoupling for Single-Phase Grid Connection for a Wide Range of Power Factor
Single-phase power converters suffer from the double frequency power pulsation. In voltage source inverters, the dc bus capacitor is designed to supply this double frequency current. The stringent dc bus voltage ripple specifications call for larger capacitance. This implies larger electrolytic capacitors. However, the electrolytic capacitor suffers from short-term life span, which consequently brings down the lifetime of the converter. As an alternative, active power decoupling (APD) ensures significant reduction in dc buffering requirement, thereby reducing the bus capacitance. This can make use of the film capacitors with better lifespan. In this paper, an APD scheme is designed and developed for the grid-connected system. Another important feature of the proposed scheme is that, it reduces the stress on the switches significantly while compared with existing APD solutions for all load power factors. The system is analyzed further to arrive at APD control conditions including the effect of grid filter inductance. The simulation and experimentation have been done to validate the proposed method. Additionally, the stress on the switches as a function of grid filter inductance is predicted theoretically and verified practically. The average stress on the switches is shown to be lesser than the existing solutions.
- Open Access
- 19 July 2017
- Published by Springer Nature in Sādhanā
- Vol. 42 (8) , 1411-1417
Active power decoupling with reduced converter stress for single-phase power conversion and interfacing
- 19 July 2017
- Published by Springer Nature in Sādhanā
- Vol. 42 (8) , 1411-1417
Open AccessActive power decoupling with reduced converter stress for single-phase power conversion and interfacing
- 1 May 2002
- Published by Wiley in SID Symposium Digest of Technical Papers
- Vol. 33 (1) , 606-609
P‐100: An Improved Four TFT Circuit for Active‐Matrix Organic Light Emitting Diode (OLED) Display
In this work we describe a new Poly‐Silicon TFT based pixel circuit which provides very good linearity over a large current range (∼25 μA) while using only four TFTs and a single control line. We also show that our approach can result in a factor of 3 improvement in current range of amorphous Silicon TFT based pixel circuits.
- 1 May 2002
- Published by Wiley in SID Symposium Digest of Technical Papers
- Vol. 33 (1) , 606-609
P‐100: An Improved Four TFT Circuit for Active‐Matrix Organic Light Emitting Diode (OLED) Display
In this work we describe a new Poly‐Silicon TFT based pixel circuit which provides very good linearity over a large current range (∼25 μA) while using only four TFTs and a single control line. We also show that our approach can result in a factor of 3 improvement in current range of amorphous Silicon TFT based pixel circuits.