YTYasuaki Tamaki

Yasuaki Tamaki

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yasuaki Tamaki has a total of 72 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Less inflammation and early functional recovery after total hip arthroplasty performed with robotic arm assistance than with computed tomography-based navigation: a propensity score-matched comparative study

    by Yasuyuki Omichi, Tomohiro Goto, Gakuto Yoshida, Yusaku Nakayama, Michihiro Takai, Ryosuke Sato, Tetsuya Enishi, Yasuaki Tamaki, Koichi Sairyo, Shunji Nakano

    Purpose It remains unclear whether robotic arm-assisted total hip arthroplasty (RA-THA) or computed tomography-based navigation THA (CN-THA) is clinically superior. This study compared post-operative inflammatory responses, pain, functional recovery, and clinical benefits between RA-THA and CN-THA. Methods This retrospective study included 496 consecutive hips that underwent RA-THA or CN-THA via an anterolateral supine approach between 2020 and 2024. After propensity score-based matching, the sample size was 158 hips in each group. Single reaming was performed in RA-THA, whereas multiple reamings were performed in CN-THA. Demographics, C-reactive protein (CRP) levels, ten-point numeric rating scale (NRS) pain scores, functional recovery, and complications were recorded. Results CRP on post-operative days (POD) 1 and 7 (1.8 ± 1.3 mg/dL vs 2.7 ± 1.8 mg/dL, 2.1 ± 1.2 mg/dL vs 3.8 ± 2.5 mg/dL, p < 0.001), NRS pain scores on PODs 1, 3 and 14 (2.4 ± 0.3 vs 2.6 ± 0.4, 2.4 ± 0.2 vs 2.6 ± 0.2, 1.4 ± 0.8 vs 2.0 ± 0.7, respectively, all p < 0.001), and days to independent walking (9.0 ± 2.3 days vs 10.7 ± 2.7 days, p < 0.001) were significantly lower in the RA-THA group. The incidence of asymptomatic deep vein thrombosis (DVT) was significantly lower in the RA-THA group (4.4% vs 10.8%, p = 0.03). Other complications did not significantly differ between the two groups. Conclusion RA-THA was associated with reduced post-operative CRP, pain, and the incidence of DVT, while also contributing to early functional recovery. Single reaming may have contributed to decreased inflammatory responses and early functional recovery.

  • Preoperative factors associated with long-distance walking ability one year after total hip arthroplasty: a prospective cohort study

    by Ken Tomonari, Yasuaki Tamaki, Takashi Saito, Motomu Kamada, Yuka Sugiyama, Megumi Yamada, Tomohiro Goto, Yasuyuki Omichi, Keizo Wada, Shota Shigekiyo, et al.

    Purpose This study aimed to identify preoperative predictors of the six-minute walk distance (6MWD) one year after primary unilateral total hip arthroplasty (THA). Methods This prospective cohort study included 152 women with hip osteoarthritis who underwent primary unilateral THA between April 2016 and June 2024. Preoperative assessments included age, body mass index (BMI), pain intensity (numerical rating scale), Timed Up and Go (TUG) test, 6MWD, hip abductor strength, range of motion (ROM) in flexion and extension at the hip, presence of contralateral hip osteoarthritis, and gait pattern (independent/cane-assisted). The primary outcome was 6MWD at one year postoperatively. Univariate and multiple linear regression analyses were performed to identify independent preoperative predictors of the 6MWD at one year postoperatively. Results All functional outcomes except BMI improved significantly at one year postoperatively. Multiple regression analysis identified age (β = − 2.8, p = 0.001), BMI (β = − 3.3, p = 0.049), preoperative 6MWD (β = 0.6, p = 0.001), and contralateral hip extension ROM (β = 2.8, p = 0.045) as independent predictors of 6MWD at one year postoperatively. Conclusions The 6MWD significantly improved one year after THA but not to the level observed in healthy individuals. Long-distance walking ability one year after THA is associated not only with systemic factors such as age, BMI, and preoperative endurance but also with contralateral hip extension ROM. The functional status of both lower limbs and global physical capacity should be considered when evaluating postoperative walking recovery.


  • Open Access

    Incidence of deep vein thrombosis following total hip arthroplasty using the anterolateral supine, direct lateral, and posterolateral approaches: a retrospective study

    by Yasuyuki Omichi, Tomohiro Goto, Yasuaki Tamaki, Gakuto Yoshida, Yusaku Nakayama, Michihiro Takai, Ryosuke Sato, Tetsuya Enishi, Koichi Sairyo, Shunji Nakano


  • Open Access

    Flexion‐dependent differences in tibial rotation measured by navigation and robotic systems during bicruciate‐stabilised total knee arthroplasty

    by Keizo Wada, Daisuke Hamada, Yasuaki Tamaki, Shota Shigekiyo, Yuto Sugimine, Koichi Sairyo

    Purpose: This study compared the intraoperative tibial rotational kinematics between navigation‐assisted and robotic‐assisted bicruciate‐stabilised total knee arthroplasty (BCS‐TKA). Although both systems can evaluate knee motion intraoperatively, it is unclear whether they provide comparable rotational measurements. We hypothesised that these systems would show different tibial rotation profiles, particularly in deep knee flexion. Methods: This retrospective cohort study included 238 knees that underwent BCS‐TKA using an image‐free navigation system (Precision N) or an image‐free handheld robotic‐assisted system (NAVIO or CORI). Tibial rotation relative to the femur was measured intraoperatively through 0° to 120° of knee flexion. Patient‐reported outcomes were assessed using the 2011 Knee Society Score (KSS). Discrepancies in rotational display between the systems were evaluated by a preliminary bench test using a synthetic bone model. Groups were compared using the Kruskal–Wallis test followed by Dunn's post hoc test with Bonferroni correction. Results: Across all groups, BCS‐TKA demonstrated a characteristic pattern of internal rotation in early flexion, slight external rotation in mid‐flexion and progressive internal rotation towards deep flexion. At 120° of flexion, tibial internal rotation differed significantly among the three groups ( p < 0.05), with the navigation system displaying greater internal rotation than the robotic system, particularly NAVIO ( p < 0.01). The robotic system displayed a progressively more externally rotated tibial position beyond 40° of flexion in the bench test. The subjective domains of the KSS improved significantly in all groups at 1 year. Although statistically significant between‐group differences were observed in some domains, these differences were inconsistent, and their clinical relevance remains unclear. Conclusions: The robotic platform consistently indicated a more externally rotated tibial position compared to the navigation system, suggesting that the two systems apply different reference orientations for tibial rotation in deep knee flexion during BCS‐TKA. Therefore, caution is warranted when comparing intraoperative kinematic data across measurement platforms. Level of Evidence: Level III, retrospective cohort study.

  • Cutoff values of knee extensor strength for stair ascent and descent after bicruciate-stabilized total knee arthroplasty

    by Taiki Furumoto, Daisuke Hamada, Keizo Wada, Ken Tomonari, Yasuaki Tamaki, Shota Shigekiyo, Tetsuya Matsuura, Koichi Sairyo


  • Accuracy of intraoperative leg length and stem version measurements in robotic-assisted total hip arthroplasty using the Mako system with enhanced mode

    by Yasuaki Tamaki, Keizo Wada, Shota Shigekiyo, Yuto Sugimine, Ken Tomonari, Koichi Sairyo

    Purpose This study evaluated the accuracy of intraoperative leg length and femoral anteversion measurements obtained during total hip arthroplasty (THA) using the Mako robotic system with enhanced mode. Methods A total of 55 hips in four men and 51 women who underwent primary THA with the Mako system via an anterolateral approach were retrospectively evaluated. Intraoperative measurements of leg length and femoral anteversion displayed by the Mako enhanced mode were compared with postoperative CT-based measurements. Absolute errors and their distributions were calculated to assess the accuracy of intraoperative assessments. Results The mean absolute error was 2.3 ± 1.8 mm for postoperative leg length discrepancy and 2.9 ± 2.2° for stem anteversion. Of the 55 hips, 46 (83.6%) showed leg length errors within 3 mm and 51 (92.7%) within 5 mm. For stem anteversion, 48 hips (87.3%) were within 3° and all 55 hips (100%) were within 5°. Mako enhanced mode could not be completed in 10.7% of cases because of femoral array loosening or screw penetration into the medullary canal. Conclusion Mako enhanced mode demonstrated clinically acceptable accuracy for intraoperative measurement of leg length and femoral anteversion, contributing to precise femoral stem implantation in robotic-assisted THA.


  • Comparison of methods for evaluating soft tissue balance in robotic-assisted total knee arthroplasty: A cadaveric study

    by Yasuaki Tamaki, Daisuke Hamada, Keizo Wada, Shota Shigekiyo, Yuto Sugimine, Yutaka Kinoshita, Koichi Tomita, Koichi Sairyo


  • Kinematic comparison between the knee after bicruciate stabilized total knee arthroplasty and the native knee: A cadaveric study

    by Yasuaki Tamaki, Daisuke Hamada, Keizo Wada, Tomoya Takasago, Akihiro Nitta, Yasuyuki Omichi, Tomohiro Goto, Yoshihiro Tsuruo, Koichi Sairyo


  • Open Access

    Relationship between iliopsoas muscle surface pressure and implant alignment after total hip arthroplasty: a cadaveric study

    by Yasuaki Tamaki, Tomohiro Goto, Joji Iwase, Keizo Wada, Yasuyuki Omichi, Daisuke Hamada, Yoshihiro Tsuruo, Koichi Sairyo

    Iliopsoas impingement after total hip arthroplasty is caused by the implant irritating the iliopsoas muscle, but changes in the iliopsoas muscle have not been quantitatively evaluated. This study assessed changes in the surface pressure of the iliopsoas muscle when the implant alignment was varied. Total hip arthroplasty was performed in 10 fresh-frozen cadaveric hips. We evaluated the maximum and mean surface pressure of the iliopsoas muscle with the hip in 20° and 10° extension, the neutral position, and 10° flexion when the anterior cup protrusion length (ACPL), stem version, and stem offset were varied. When the ACPL was changed to 0, 3, and 6 mm in 20° extension, the maximum surface pressure was significantly increased for ACPL of 6 mm compared with 0 mm. Decreased stem anteversion resulted in a significant reduction in both the maximum and mean surface pressure compared with native anteversion from 20° extension to the neutral position. Increased stem offset resulted in significant increases in the maximum and mean surface pressure of the iliopsoas muscle compared with decreased stem offset in 20° extension. Not only large ACPL but also changes in stem version and offset affected the maximum surface pressure of the iliopsoas muscle.