Yong Choi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yong Choi has a total of 84 co-authors. Here are the top co-authors by number of shared publications:
- Jin Ho Jung
Department of Electronic Engineering, Sogang University, Seoul, Korea
11 shared publications - Jiwoong Jung
Sogang Univ, Dept Elect Engn, 35 Baekbeom Ro, Seoul 04107, South Korea
11 shared publications Jin Ho Jung
9 shared publicationsJihoon Kang
Department of Biomedical Engineering, Chonnam National University, Yeosu 550-749, Republic of Korea
6 shared publicationsWei Hu
Minfound Medical Systems Co., Ltd
6 shared publicationsHyun Keong Lim
Department of Electronic Engineering, Sogang University, Seoul, Korea
5 shared publications
Latest Publications
- Open Access
- 13 February 2024
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (7) , 2633-2640
Effects of reflector, surface treatment, and length of scintillation crystal on the performance of TOF-DOI PET detector with dual-ended readout
- 13 February 2024
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (7) , 2633-2640
Open AccessEffects of reflector, surface treatment, and length of scintillation crystal on the performance of TOF-DOI PET detector with dual-ended readout
- Open Access
- 10 December 2023
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (4) , 1532-1537
Low-noise fast-response readout circuit to improve coincidence time resolution
- 10 December 2023
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (4) , 1532-1537
Open AccessLow-noise fast-response readout circuit to improve coincidence time resolution
- Open Access
- 14 October 2022
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 55 (2) , 484-492
Linearity improvement of UltraScale+ FPGA-based time-to-digital converter
- 14 October 2022
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 55 (2) , 484-492
Open AccessLinearity improvement of UltraScale+ FPGA-based time-to-digital converter
- 23 June 2022
- Published by Springer Nature
- p. 117-128
Artificial Intelligence/Machine Learning in Nuclear Medicine
- 23 June 2022
- Published by Springer Nature
- p. 117-128
Artificial Intelligence/Machine Learning in Nuclear Medicine
- 11 March 2022
- Published by Springer Nature in Journal of the Korean Physical Society
- Vol. 80 (7) , 640-646
Evaluation of RF shielding materials to improve MR image of hybrid PET/MRI
- 11 March 2022
- Published by Springer Nature in Journal of the Korean Physical Society
- Vol. 80 (7) , 640-646
Evaluation of RF shielding materials to improve MR image of hybrid PET/MRI
- Open Access
- 10 February 2022
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 54 (7) , 2592-2598
Optimized TOF-PET detector using scintillation crystal array for brain imaging
- 10 February 2022
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 54 (7) , 2592-2598
Open AccessOptimized TOF-PET detector using scintillation crystal array for brain imaging
- 12 November 2021
- Published by Springer Nature in Nuclear Medicine and Molecular Imaging
- Vol. 55 (6) , 265-284
A Brief History of Nuclear Medicine Physics, Instrumentation, and Data Sciences in Korea
We review the history of nuclear medicine physics, instrumentation, and data sciences in Korea to commemorate the 60th anniversary of the Korean Society of Nuclear Medicine. In the 1970s and 1980s, the development of SPECT, nuclear stethoscope, and bone densitometry systems, as well as kidney and cardiac image analysis technology, marked the beginning of nuclear medicine physics and engineering in Korea. With the introduction of PET and cyclotron in Korea in 1994, nuclear medicine imaging research was further activated. With the support of large-scale government projects, the development of gamma camera, SPECT, and PET systems was carried out. Exploiting the use of PET scanners in conjunction with cyclotrons, extensive studies on myocardial blood flow quantification and brain image analysis were also actively pursued. In 2005, Korea’s first domestic cyclotron succeeded in producing radioactive isotopes, and the cyclotron was provided to six universities and university hospitals, thereby facilitating the nationwide supply of PET radiopharmaceuticals. Since the late 2000s, research on PET/MRI has been actively conducted, and the advanced research results of Korean scientists in the fields of silicon photomultiplier PET and simultaneous PET/MRI have attracted significant attention from the academic community. Currently, Korean researchers are actively involved in endeavors to solve a variety of complex problems in nuclear medicine using artificial intelligence and deep learning technologies.
- 12 November 2021
- Published by Springer Nature in Nuclear Medicine and Molecular Imaging
- Vol. 55 (6) , 265-284
A Brief History of Nuclear Medicine Physics, Instrumentation, and Data Sciences in Korea
We review the history of nuclear medicine physics, instrumentation, and data sciences in Korea to commemorate the 60th anniversary of the Korean Society of Nuclear Medicine. In the 1970s and 1980s, the development of SPECT, nuclear stethoscope, and bone densitometry systems, as well as kidney and cardiac image analysis technology, marked the beginning of nuclear medicine physics and engineering in Korea. With the introduction of PET and cyclotron in Korea in 1994, nuclear medicine imaging research was further activated. With the support of large-scale government projects, the development of gamma camera, SPECT, and PET systems was carried out. Exploiting the use of PET scanners in conjunction with cyclotrons, extensive studies on myocardial blood flow quantification and brain image analysis were also actively pursued. In 2005, Korea’s first domestic cyclotron succeeded in producing radioactive isotopes, and the cyclotron was provided to six universities and university hospitals, thereby facilitating the nationwide supply of PET radiopharmaceuticals. Since the late 2000s, research on PET/MRI has been actively conducted, and the advanced research results of Korean scientists in the fields of silicon photomultiplier PET and simultaneous PET/MRI have attracted significant attention from the academic community. Currently, Korean researchers are actively involved in endeavors to solve a variety of complex problems in nuclear medicine using artificial intelligence and deep learning technologies.
- 13 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 6 (7) , 788-793
A Diode-Based Symmetric Charge Division Circuit With Grounding Path to Reduce Signal Crosstalk and Improve Detector Performance
Multiplexing circuits in pixelated PET detectors are being studied with the goal of minimizing the degradation of detector performance. The purpose of this study was to develop a diode-based symmetric charge division (SCD) circuit with reducing the crosstalk caused by the leakage currents of adjacent channels connected in rows and columns. Four different SCD circuits (diode-based SCD with grounding path, diode-based SCD, resistor-based SCD with grounding path, and resistor-based SCD) were constructed and their performance was evaluated and compared after being combined with a PET detector consisting of Lutetium Yttrium Orthosilicate crystals optically coupled with SiPM. The diode-based SCD circuit with grounding path achieved a crosstalk ratio, energy resolution, coincidence timing resolution (CTR), and mean peak to valley ratio of 0.02, 14.3%, 0.5 ns, and 27.9: 1, respectively; the diode-based SCD circuit achieved 0.03, 15.9%, 0.7 ns, and 19.4: 1, respectively; the resistor-based SCD circuit with grounding path achieved 0.04, 14.5%, 0.9 ns, and 19.4: 1, respectively; and the resistor-based SCD circuit achieved 0.05, 17.8%, 1.8 ns, and 17.7: 1, respectively. These results indicate that the proposed SCD has the potential to improve not only the crosstalk but also the energy linearity, energy resolution, and CTR characteristics in PET detectors.
- 13 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 6 (7) , 788-793
A Diode-Based Symmetric Charge Division Circuit With Grounding Path to Reduce Signal Crosstalk and Improve Detector Performance
Multiplexing circuits in pixelated PET detectors are being studied with the goal of minimizing the degradation of detector performance. The purpose of this study was to develop a diode-based symmetric charge division (SCD) circuit with reducing the crosstalk caused by the leakage currents of adjacent channels connected in rows and columns. Four different SCD circuits (diode-based SCD with grounding path, diode-based SCD, resistor-based SCD with grounding path, and resistor-based SCD) were constructed and their performance was evaluated and compared after being combined with a PET detector consisting of Lutetium Yttrium Orthosilicate crystals optically coupled with SiPM. The diode-based SCD circuit with grounding path achieved a crosstalk ratio, energy resolution, coincidence timing resolution (CTR), and mean peak to valley ratio of 0.02, 14.3%, 0.5 ns, and 27.9: 1, respectively; the diode-based SCD circuit achieved 0.03, 15.9%, 0.7 ns, and 19.4: 1, respectively; the resistor-based SCD circuit with grounding path achieved 0.04, 14.5%, 0.9 ns, and 19.4: 1, respectively; and the resistor-based SCD circuit achieved 0.05, 17.8%, 1.8 ns, and 17.7: 1, respectively. These results indicate that the proposed SCD has the potential to improve not only the crosstalk but also the energy linearity, energy resolution, and CTR characteristics in PET detectors.