Jiwoong Jung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiwoong Jung has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Yong Choi
Sogang University
11 shared publications - Jin Ho Jung
Department of Electronic Engineering, Sogang University, Seoul, Korea
6 shared publications - Kuntai Park
Department of Electronic Engineering, Sogang University, Seoul, South Korea
4 shared publications Sangwon Lee
3 shared publications- Sangwon Lee
Department of Nuclear Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea
3 shared publications Yeonkyeong Kim
3 shared publications
Latest Publications
- Open Access
- 13 February 2024
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (7) , 2633-2640
Effects of reflector, surface treatment, and length of scintillation crystal on the performance of TOF-DOI PET detector with dual-ended readout
- 13 February 2024
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (7) , 2633-2640
Open AccessEffects of reflector, surface treatment, and length of scintillation crystal on the performance of TOF-DOI PET detector with dual-ended readout
- Open Access
- 10 December 2023
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (4) , 1532-1537
Low-noise fast-response readout circuit to improve coincidence time resolution
- 10 December 2023
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (4) , 1532-1537
Open AccessLow-noise fast-response readout circuit to improve coincidence time resolution
- Open Access
- 14 October 2022
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 55 (2) , 484-492
Linearity improvement of UltraScale+ FPGA-based time-to-digital converter
- 14 October 2022
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 55 (2) , 484-492
Open AccessLinearity improvement of UltraScale+ FPGA-based time-to-digital converter
- Open Access
- 10 February 2022
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 54 (7) , 2592-2598
Optimized TOF-PET detector using scintillation crystal array for brain imaging
- 10 February 2022
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 54 (7) , 2592-2598
Open AccessOptimized TOF-PET detector using scintillation crystal array for brain imaging
- 13 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 6 (7) , 788-793
A Diode-Based Symmetric Charge Division Circuit With Grounding Path to Reduce Signal Crosstalk and Improve Detector Performance
Multiplexing circuits in pixelated PET detectors are being studied with the goal of minimizing the degradation of detector performance. The purpose of this study was to develop a diode-based symmetric charge division (SCD) circuit with reducing the crosstalk caused by the leakage currents of adjacent channels connected in rows and columns. Four different SCD circuits (diode-based SCD with grounding path, diode-based SCD, resistor-based SCD with grounding path, and resistor-based SCD) were constructed and their performance was evaluated and compared after being combined with a PET detector consisting of Lutetium Yttrium Orthosilicate crystals optically coupled with SiPM. The diode-based SCD circuit with grounding path achieved a crosstalk ratio, energy resolution, coincidence timing resolution (CTR), and mean peak to valley ratio of 0.02, 14.3%, 0.5 ns, and 27.9: 1, respectively; the diode-based SCD circuit achieved 0.03, 15.9%, 0.7 ns, and 19.4: 1, respectively; the resistor-based SCD circuit with grounding path achieved 0.04, 14.5%, 0.9 ns, and 19.4: 1, respectively; and the resistor-based SCD circuit achieved 0.05, 17.8%, 1.8 ns, and 17.7: 1, respectively. These results indicate that the proposed SCD has the potential to improve not only the crosstalk but also the energy linearity, energy resolution, and CTR characteristics in PET detectors.
- 13 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 6 (7) , 788-793
A Diode-Based Symmetric Charge Division Circuit With Grounding Path to Reduce Signal Crosstalk and Improve Detector Performance
Multiplexing circuits in pixelated PET detectors are being studied with the goal of minimizing the degradation of detector performance. The purpose of this study was to develop a diode-based symmetric charge division (SCD) circuit with reducing the crosstalk caused by the leakage currents of adjacent channels connected in rows and columns. Four different SCD circuits (diode-based SCD with grounding path, diode-based SCD, resistor-based SCD with grounding path, and resistor-based SCD) were constructed and their performance was evaluated and compared after being combined with a PET detector consisting of Lutetium Yttrium Orthosilicate crystals optically coupled with SiPM. The diode-based SCD circuit with grounding path achieved a crosstalk ratio, energy resolution, coincidence timing resolution (CTR), and mean peak to valley ratio of 0.02, 14.3%, 0.5 ns, and 27.9: 1, respectively; the diode-based SCD circuit achieved 0.03, 15.9%, 0.7 ns, and 19.4: 1, respectively; the resistor-based SCD circuit with grounding path achieved 0.04, 14.5%, 0.9 ns, and 19.4: 1, respectively; and the resistor-based SCD circuit achieved 0.05, 17.8%, 1.8 ns, and 17.7: 1, respectively. These results indicate that the proposed SCD has the potential to improve not only the crosstalk but also the energy linearity, energy resolution, and CTR characteristics in PET detectors.
- Open Access
Feasibility Study of a Time-of-Flight Brain Positron Emission Tomography Employing Individual Channel Readout Electronics
The purpose of this study was to investigate the feasibility of a time-of-flight (TOF) brain positron emission tomography (PET) providing high-quality images. It consisted of 30 detector blocks arranged in a ring with a diameter of 257 mm and an axial field of view of 52.2 mm. Each detector block was composed of two detector modules and two application-specific integrated circuit (ASIC) chips. The detector module was composed of an 8 × 8 array of 3 × 3 mm2 multi-pixel photon counters and an 8 × 8 array of 3.11 × 3.11 × 15 mm3 lutetium yttrium oxyorthosilicate scintillators. The 64-channel individual readout ASIC was used to acquire the position, energy, and time information of a detected gamma ray. A coincidence timing resolution of 187 ps full width at half maximum (FWHM) was achieved using a pair of channels of two detector modules. The energy resolution and spatial resolution were 6.6 ± 0.6% FWHM (without energy nonlinearity correction) and 2.5 mm FWHM, respectively. The results of this study demonstrate that the developed TOF brain PET could provide excellent performance, allowing for a reduction in radiation dose or scanning time for brain imaging due to improved sensitivity and signal-to-noise ratio.
Open AccessFeasibility Study of a Time-of-Flight Brain Positron Emission Tomography Employing Individual Channel Readout Electronics
The purpose of this study was to investigate the feasibility of a time-of-flight (TOF) brain positron emission tomography (PET) providing high-quality images. It consisted of 30 detector blocks arranged in a ring with a diameter of 257 mm and an axial field of view of 52.2 mm. Each detector block was composed of two detector modules and two application-specific integrated circuit (ASIC) chips. The detector module was composed of an 8 × 8 array of 3 × 3 mm2 multi-pixel photon counters and an 8 × 8 array of 3.11 × 3.11 × 15 mm3 lutetium yttrium oxyorthosilicate scintillators. The 64-channel individual readout ASIC was used to acquire the position, energy, and time information of a detected gamma ray. A coincidence timing resolution of 187 ps full width at half maximum (FWHM) was achieved using a pair of channels of two detector modules. The energy resolution and spatial resolution were 6.6 ± 0.6% FWHM (without energy nonlinearity correction) and 2.5 mm FWHM, respectively. The results of this study demonstrate that the developed TOF brain PET could provide excellent performance, allowing for a reduction in radiation dose or scanning time for brain imaging due to improved sensitivity and signal-to-noise ratio.
- 1 February 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (4) , 045015
Performance evaluation of a small animal PET scanner a high level of multiplexing and charge-signal transmission
Small animal positron emission tomography (PET) is a noninvasive imaging modality that enables in vivo imaging and quantification of the biological processes of small experimental animals. We have developed a small animal PET that utilizes a high-resolution multiplexed readout and charge signal transmission (CST) method. The small animal PET was composed of six detector blocks consisting of SiPMs and LYSO arrays. Six detector blocks were mounted on a PET gantry having an inner diameter of 76 mm, outer diameter of 112 mm, and axial length of 40.8 mm. The charge signals of SiPM output were transmitted to the input of multiplexed readout using 4 m flexible flat cables. The multiplexed readout was composed of six main boards, each of which included 36 detector boards, to reduce the number of readout channels by a factor of 36, with a multiplexing ratio of 144:4. The performance of the small animal PET was evaluated using NEMA NU 4-2008 standards, and its imaging capability was demonstrated by in vivo mouse imaging studies. The average energy and time resolutions were 13.2% ± 0.3% and 3.8 ns, respectively. The spatial resolution at the center of the transaxial FOV was 1.1 mm, and the peak sensitivity at the center of the axial FOV was 1.5%. The peak noise equivalent count (NEC) rate and scatter fraction were 21.1 kcps at 18.2 MBq and 21%, respectively. The acquired images demonstrated high quality tracer uptake patterns of small experimental animals. The results of performance evaluation and animal imaging indicate that the small animal PET developed in this study can provide high-quality small animal imaging with cost-effectiveness and compactness.
- 1 February 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (4) , 045015
Performance evaluation of a small animal PET scanner a high level of multiplexing and charge-signal transmission
Small animal positron emission tomography (PET) is a noninvasive imaging modality that enables in vivo imaging and quantification of the biological processes of small experimental animals. We have developed a small animal PET that utilizes a high-resolution multiplexed readout and charge signal transmission (CST) method. The small animal PET was composed of six detector blocks consisting of SiPMs and LYSO arrays. Six detector blocks were mounted on a PET gantry having an inner diameter of 76 mm, outer diameter of 112 mm, and axial length of 40.8 mm. The charge signals of SiPM output were transmitted to the input of multiplexed readout using 4 m flexible flat cables. The multiplexed readout was composed of six main boards, each of which included 36 detector boards, to reduce the number of readout channels by a factor of 36, with a multiplexing ratio of 144:4. The performance of the small animal PET was evaluated using NEMA NU 4-2008 standards, and its imaging capability was demonstrated by in vivo mouse imaging studies. The average energy and time resolutions were 13.2% ± 0.3% and 3.8 ns, respectively. The spatial resolution at the center of the transaxial FOV was 1.1 mm, and the peak sensitivity at the center of the axial FOV was 1.5%. The peak noise equivalent count (NEC) rate and scatter fraction were 21.1 kcps at 18.2 MBq and 21%, respectively. The acquired images demonstrated high quality tracer uptake patterns of small experimental animals. The results of performance evaluation and animal imaging indicate that the small animal PET developed in this study can provide high-quality small animal imaging with cost-effectiveness and compactness.
- 25 June 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (13) , 135002
An improved time over threshold method using bipolar signals
The time over threshold (TOT) method has been recently proposed as a signal processing method used to calculate time and energy information by measuring the pulse arrival time and pulse duration over a preset threshold. Although TOT has been reported as an effective method for front end readout in PET applications, it has several limitations, including its non-linearity, lower dynamic range, and a trade-off between energy resolution and coincidence resolving time (CRT). In this study, we propose a novel design we developed to improve performance with regard to these problems occurring in the conventional TOT by employing a bipolar signal and two comparators. Using a high frequency CR shaping filter, a detected signal was converted into a bipolar signal, and the positive pulse of the converted bipolar signal had a fast rising time, while the negative pulse had a linear slope. The bipolar TOT circuit was composed of a preamplifier, a CR shaping filter, and two comparators. The PET detector was composed of a single LYSO coupled with 4 × 4 SiPM arrays, a bipolar TOT circuit, and an FPGA based TDC. And this was constructed to evaluate the performance of the proposed bipolar TOT method. A 16-ch PET detector module consisting of a 4 × 4 array LYSO coupled to a 4 × 4 SiPM arrays, an Anger logic discretized positioning circuit, and a 4-ch bipolar TOT circuit was also constructed to evaluate the functionality of the bipolar TOT method for PET applications. The pulse height resolution and CRT were measured using both the bipolar TOT method and the conventional TOT method. While the bipolar TOT method provided a similar pulse height resolution (10.4% ± 0.1%), the integral non-linearity (1.4%) and CRT (168 ± 4 ps) measured using the bipolar TOT method were greatly improved compared to those (17.2% and 258 ± 15 ps, respectively) measured with the conventional TOT method. The positions of the crystals were clearly identified, as seen in the flood histogram acquired using the 4-ch bipolar TOT circuit. The measured average pulse height resolution and average CRT for the 16-ch detector module were 11.5% ± 0.2% and 516 ± 24 ps. The results obtained in this study indicate that the bipolar TOT method requiring a relatively small number of electronic components could effectively improve the CRT, linearity and dynamic range. Furthermore, they also demonstrated the extendibility allowing the development of a PET system that consists of a large number of detectors.
- 25 June 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (13) , 135002
An improved time over threshold method using bipolar signals
The time over threshold (TOT) method has been recently proposed as a signal processing method used to calculate time and energy information by measuring the pulse arrival time and pulse duration over a preset threshold. Although TOT has been reported as an effective method for front end readout in PET applications, it has several limitations, including its non-linearity, lower dynamic range, and a trade-off between energy resolution and coincidence resolving time (CRT). In this study, we propose a novel design we developed to improve performance with regard to these problems occurring in the conventional TOT by employing a bipolar signal and two comparators. Using a high frequency CR shaping filter, a detected signal was converted into a bipolar signal, and the positive pulse of the converted bipolar signal had a fast rising time, while the negative pulse had a linear slope. The bipolar TOT circuit was composed of a preamplifier, a CR shaping filter, and two comparators. The PET detector was composed of a single LYSO coupled with 4 × 4 SiPM arrays, a bipolar TOT circuit, and an FPGA based TDC. And this was constructed to evaluate the performance of the proposed bipolar TOT method. A 16-ch PET detector module consisting of a 4 × 4 array LYSO coupled to a 4 × 4 SiPM arrays, an Anger logic discretized positioning circuit, and a 4-ch bipolar TOT circuit was also constructed to evaluate the functionality of the bipolar TOT method for PET applications. The pulse height resolution and CRT were measured using both the bipolar TOT method and the conventional TOT method. While the bipolar TOT method provided a similar pulse height resolution (10.4% ± 0.1%), the integral non-linearity (1.4%) and CRT (168 ± 4 ps) measured using the bipolar TOT method were greatly improved compared to those (17.2% and 258 ± 15 ps, respectively) measured with the conventional TOT method. The positions of the crystals were clearly identified, as seen in the flood histogram acquired using the 4-ch bipolar TOT circuit. The measured average pulse height resolution and average CRT for the 16-ch detector module were 11.5% ± 0.2% and 516 ± 24 ps. The results obtained in this study indicate that the bipolar TOT method requiring a relatively small number of electronic components could effectively improve the CRT, linearity and dynamic range. Furthermore, they also demonstrated the extendibility allowing the development of a PET system that consists of a large number of detectors.