EBEthan W. Blackburn

Ethan W. Blackburn

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ethan W. Blackburn has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Ankle Fractures in Children

    by Ethan W. Blackburn, David D. Aronsson, James H. Rubright, Jennifer W. Lisle

    Computed tomography is useful for preoperative planning and postreduction assessment for intra-articular pediatric ankle fractures. Nondisplaced pediatric ankle fractures can be effectively managed with cast immobilization and close radiographic follow-up evaluation. Physeal ankle injuries in younger children with considerable growth remaining should be followed closely for at least one year after injury as growth arrest may result in substantial angular deformity. Open reduction and internal fixation should be strongly considered when an articular step-off of <2 mm cannot be maintained by closed means for Salter-Harris type-III and IV and transitional ankle fractures.


  • Biomechanical comparison of screw-in suture anchor–suture combinations used for Bankart repair

    by Brad S. Sparks, John Nyland, Akbar Nawab, Ethan Blackburn, Ryan Krupp, David N. M. Caborn

    Bankart repair laxity may contribute to pathologic joint instability. This biomechanical study compared two screw-in suture anchor–suture combinations under tensile loads. Twelve pairs of scapulae were implanted with either a 3 mm diameter, 14 mm long poly-l/d-lactide suture anchor with a suture eyelet (Group 1) or a 3.1 mm diameter, 11 mm long polylactide suture anchor with a molded eyelet (Group 2). Constructs were cyclically loaded between 25 and 50 N with a 25 N load increase every 25 cycles. Group 2 displayed greater displacement at failure, had more specimens with ≥2 mm displacement by the 50 N interval (P = 0.014), and had displaced more by 100 N (P ≤ 0.046). Group 1 displayed a stronger load–displacement at failure relationship than Group 2 (r 2 = 0.67 vs. r 2 = 0.37). Construct differences may influence decisions regarding the required number of suture anchor–suture loops, the rehabilitation timetable, and the timing of return to unrestricted activities.


  • Cyclic loading comparison of Bio‐SutureTak‐#2 FiberWire and Bio Mini‐Revo‐#2 Hi‐Fi suture anchor‐sutures in cadaveric scapulae

    by Brad S. Sparks, John Nyland, Akbar Nawab, Ethan Blackburn, Ryan Krupp, Robert Burden

    This study compared tap‐in Bio‐SutureTak suture anchor‐#2 FiberWire suture (Group 1) and screw‐in Bio Mini‐Revo suture anchor‐#2 Hi‐Fi suture (Group 2) fixation in the glenoid region of interest for Bankart repair, in addition to evaluation of isolated suture loop biomechanical properties under progressive incremental cyclic loads. With knowledge of glenoid apparent bone mineral density (BMD), implant preparation and fit characteristics, and following application of a light manual tensile load, the primary investigator scored each specimen for perceived within group biomechanical test performance using a 0–10 point modified visual analog scale. After scoring, 12 paired constructs were placed in a servo hydraulic device clamp, preloaded to 25 N, and cycled between 25 and 50 Hz with a 25 N load increase every 25 cycles. Group 2 withstood greater load (104.1 ± 56 vs. 70 ± 36.9 N, P = 0.04) and displaced more at failure (13 ± 4.5 vs. 8.6 ± 3.3 mm, P = 0.04). All Group 1 specimens failed prior to reaching 150 N, whereas 25% of Group 2 specimens (n = 3) failed at 200 N. All specimens failed by anchor pullout except for three Group 2 specimens that failed by eyelet breakage at 200 N. Isolated suture testing revealed that Group 1 sutures displaced less at each cyclic load (P = 0.028) and withstood greater failure loads (P = 0.028) than that of Group 2 sutures. Group 2 constructs displayed moderately strong relationships between perceived within group biomechanical test performance and ultimate load (r2 = 0.55) and displacement at failure (r2 = 0.67). Group 1 did not display significant relationships. Similar biomechanical performance between 50 and 125 N, greater load at failure, and superior biomechanical test prediction accuracy suggest that the screw‐in type Bio Mini‐Revo suture anchor‐#2 Hi‐Fi suture combination may be preferred for Bankart lesion repair in low apparent BMD glenoid processes. The #2 Hi‐Fi suture, however, allowed significantly greater displacement than the #2 FiberWire suture at each progressive cyclic load interval.