Ju Dong Lee
Ju Dong Lee has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
John B. Mander
Zachry Professor in Design and Construction Integration I, Zachry Dept. of Civil Engineering, Texas A&M Univ., 3136 TAMU, College Station, TX 77843
3 shared publications- Anna C. Birely
Assistant Professor, Zachry Dept. of Civil Engineering, Texas A&M Univ., 3136 TAMU, College Station, TX 77843. ORCID:
2 shared publications - Codi D. McKee
Graduate Assistant Researcher, Zachry Dept. of Civil Engineering, Texas A&M Univ., 3136 TAMU, College Station, TX 77843
2 shared publications Thomas H.-K. Kang
2 shared publicationsAh Sir Cho
1 shared publicationBum Sik Lee
1 shared publication
Latest Publications
- 1 July 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 148 (7) , 04022074
Unified Truss-Arch Model for the Analysis of Bending-Shear Interaction in Reinforced Concrete Members
The compatibility strut-and-tie method (C-STM) is a well-established nonlinear modeling tool to efficiently and accurately predict the overall load–deformation response of shear-critical RC members subjected to combined bending and shear. Such a high-performance tool, however, is computationally demanding. In this paper, a simplified limit analysis model based on C-STM is presented to predict the load-carrying capacity of RC beams. Amenable for hand methods of analysis, the approach is called the truss-arch model unified (TAMU). The TAMU approach accounts for the failure mechanism of the diagonal concrete strut that is softened because of the transverse tensile strain. Instead of providing overall force–deformation behavior, this model focuses on evaluating the ultimate load-carrying capacity by assuming the failure mechanism occurs when the principal diagonal strut reaches its softened strength in shear-critical beams. An explicit equation for the principal strain ratio is derived to evaluate the softened concrete strength and is used to develop formulas for the ultimate load-carrying capacity. The validity of the formulas is verified through a comparison of the predicted ultimate load-carrying capacities with maximum measured strengths from previous experimental results on large-scale physical tests representing bridge piers. The TAMU approach is then compared with other code-based strength analysis methods and shows better predictions of the maximum load-carrying capacity.
- 1 July 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 148 (7) , 04022074
Unified Truss-Arch Model for the Analysis of Bending-Shear Interaction in Reinforced Concrete Members
The compatibility strut-and-tie method (C-STM) is a well-established nonlinear modeling tool to efficiently and accurately predict the overall load–deformation response of shear-critical RC members subjected to combined bending and shear. Such a high-performance tool, however, is computationally demanding. In this paper, a simplified limit analysis model based on C-STM is presented to predict the load-carrying capacity of RC beams. Amenable for hand methods of analysis, the approach is called the truss-arch model unified (TAMU). The TAMU approach accounts for the failure mechanism of the diagonal concrete strut that is softened because of the transverse tensile strain. Instead of providing overall force–deformation behavior, this model focuses on evaluating the ultimate load-carrying capacity by assuming the failure mechanism occurs when the principal diagonal strut reaches its softened strength in shear-critical beams. An explicit equation for the principal strain ratio is derived to evaluate the softened concrete strength and is used to develop formulas for the ultimate load-carrying capacity. The validity of the formulas is verified through a comparison of the predicted ultimate load-carrying capacities with maximum measured strengths from previous experimental results on large-scale physical tests representing bridge piers. The TAMU approach is then compared with other code-based strength analysis methods and shows better predictions of the maximum load-carrying capacity.
- 1 January 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 25 (1)
Experimental Behavior of Pretensioned Bent Caps with Internal Voids for Weight Reduction
Precast bent caps offer the opportunity to reduce onsite labor and materials and to accelerate the speed of construction. For many bridges, the weight is manageable for shipping and placement without the need for large cranes. For large bent caps, the weight can become a significant challenge for construction. Internal voids can be effective in reducing the weight but introduce the potential for the formation of shear cracks at service loads, because the shear width is smaller than in a solid bent cap. Internal voids are an attractive option when bent caps are pretensioned, because pretensioning delays the formation of cracks. This paper presents the results of a full-scale experimental test program that investigated the progression of damage and the failure mechanisms of pretensioned bent caps with internal voids. Test specimens were subassemblies of a portion of a multicolumn bent that included an overhang, a negative bending region at the connection to a column, and a positive bending region. The variables investigated were the presence of a void, the amount of prestressing, and the void termination location. Results indicated that voided caps had similar flexural behavior to solid caps, but were more prone to shear cracking and had more brittle failures. The use of a higher prestressing force was found to significantly delay flexural cracking but to have a minor effect on delaying the formation of shear cracks. The location of void termination adjacent to the connection region influenced the extent of the damage at failure.
- 1 January 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 25 (1)
Experimental Behavior of Pretensioned Bent Caps with Internal Voids for Weight Reduction
Precast bent caps offer the opportunity to reduce onsite labor and materials and to accelerate the speed of construction. For many bridges, the weight is manageable for shipping and placement without the need for large cranes. For large bent caps, the weight can become a significant challenge for construction. Internal voids can be effective in reducing the weight but introduce the potential for the formation of shear cracks at service loads, because the shear width is smaller than in a solid bent cap. Internal voids are an attractive option when bent caps are pretensioned, because pretensioning delays the formation of cracks. This paper presents the results of a full-scale experimental test program that investigated the progression of damage and the failure mechanisms of pretensioned bent caps with internal voids. Test specimens were subassemblies of a portion of a multicolumn bent that included an overhang, a negative bending region at the connection to a column, and a positive bending region. The variables investigated were the presence of a void, the amount of prestressing, and the void termination location. Results indicated that voided caps had similar flexural behavior to solid caps, but were more prone to shear cracking and had more brittle failures. The use of a higher prestressing force was found to significantly delay flexural cracking but to have a minor effect on delaying the formation of shear cracks. The location of void termination adjacent to the connection region influenced the extent of the damage at failure.
- 1 February 2019
- Published by American Society of Civil Engineers (ASCE) in Practice Periodical on Structural Design and Construction
- Vol. 24 (1)
Recommendations for Design of Concentrically Pretensioned, Precast Concrete Bent Caps
Precast, prestressed bent caps are an attractive design option because they permit accelerated bridge construction and can extend the service life of bridges by reducing or eliminating the service-level cracking observed in RC bent caps. A design procedure is recommended for the flexural design of pretensioned bent caps in which the amount of prestressing is selected to ensure zero tension at service, with service- and strength-limit states serving as checks on the design. Recommendations include how to account for openings for connections that may influence the bent cap performance. Using the recommended flexural design procedure and AASHTO shear design provisions, pretensioned bent caps were designed for a suite of multicolumn bridges. The flexural design procedure is shown to be efficient for the design of most bridges, and many bent caps are expected to have only minor cracking, if any, at ultimate demands. The minimum area of transverse reinforcement was found to govern most bridge designs, leading to recommendations to use the general, noniterative sectional shear design method. The resulting designs lead to recommendations for how designers and contractors can use precast, pretensioned bent caps not only to enable accelerated construction and extend bridge service life but also to increase design and construction efficiency.
- 1 February 2019
- Published by American Society of Civil Engineers (ASCE) in Practice Periodical on Structural Design and Construction
- Vol. 24 (1)
Recommendations for Design of Concentrically Pretensioned, Precast Concrete Bent Caps
Precast, prestressed bent caps are an attractive design option because they permit accelerated bridge construction and can extend the service life of bridges by reducing or eliminating the service-level cracking observed in RC bent caps. A design procedure is recommended for the flexural design of pretensioned bent caps in which the amount of prestressing is selected to ensure zero tension at service, with service- and strength-limit states serving as checks on the design. Recommendations include how to account for openings for connections that may influence the bent cap performance. Using the recommended flexural design procedure and AASHTO shear design provisions, pretensioned bent caps were designed for a suite of multicolumn bridges. The flexural design procedure is shown to be efficient for the design of most bridges, and many bent caps are expected to have only minor cracking, if any, at ultimate demands. The minimum area of transverse reinforcement was found to govern most bridge designs, leading to recommendations to use the general, noniterative sectional shear design method. The resulting designs lead to recommendations for how designers and contractors can use precast, pretensioned bent caps not only to enable accelerated construction and extend bridge service life but also to increase design and construction efficiency.
- 1 September 2017
- Published by American Concrete Institute in ACI Structural Journal
- Vol. 114 (5) , 1075-1086
Punching and Lateral Cyclic Behavior of Slab-Column Connections with Shear Bands
- 1 September 2017
- Published by American Concrete Institute in ACI Structural Journal
- Vol. 114 (5) , 1075-1086
Punching and Lateral Cyclic Behavior of Slab-Column Connections with Shear Bands
- 2 January 2016
- Published by Taylor & Francis in Journal of Structural Integrity and Maintenance
- Vol. 1 (1) , 1-9
Combined half precast concrete slab and post-tensioned slab topping system for basement parking structures
It is known that the prestressed half PC (precast) slab system has many advantages such as a reduced construction period and use of long-span one-way slab systems over reinforced concrete and half PC slab systems without prestressing. For this reason, prestressed half slabs are commonly used for both residential and basement parking structures in Korea and other countries. The prestressed half PC slab systems currently being used only have the pre-tensioning system only for PC slabs. To ensure better performance of the half PC slab system with larger span-to-depth ratio, a new system using both pre-tensioning and post-tensioning methods is suggested for basement parking structures in this paper. The main purpose of this paper was to analyse the suggested model and verify its safety and serviceability for a given span and a given load. The second purpose is to suggest a preliminary calculation process for the suggested system that satisfies the ACI 318 requirements. A parametric study is conducted in order to find the best and most economic model using four variables: (1) depth of precast concrete; (2) depth of topping concrete; (3) number of pre-tensioned tendons; and (4) number of post-tensioned tendons. The obtained model satisfies the requirements of ACI 318 in terms of working stress design.
- 2 January 2016
- Published by Taylor & Francis in Journal of Structural Integrity and Maintenance
- Vol. 1 (1) , 1-9
Combined half precast concrete slab and post-tensioned slab topping system for basement parking structures
It is known that the prestressed half PC (precast) slab system has many advantages such as a reduced construction period and use of long-span one-way slab systems over reinforced concrete and half PC slab systems without prestressing. For this reason, prestressed half slabs are commonly used for both residential and basement parking structures in Korea and other countries. The prestressed half PC slab systems currently being used only have the pre-tensioning system only for PC slabs. To ensure better performance of the half PC slab system with larger span-to-depth ratio, a new system using both pre-tensioning and post-tensioning methods is suggested for basement parking structures in this paper. The main purpose of this paper was to analyse the suggested model and verify its safety and serviceability for a given span and a given load. The second purpose is to suggest a preliminary calculation process for the suggested system that satisfies the ACI 318 requirements. A parametric study is conducted in order to find the best and most economic model using four variables: (1) depth of precast concrete; (2) depth of topping concrete; (3) number of pre-tensioned tendons; and (4) number of post-tensioned tendons. The obtained model satisfies the requirements of ACI 318 in terms of working stress design.
- 1 November 2015
- Published by American Concrete Institute in ACI Structural Journal
- Vol. 112 (6)
Experimental and Numerical Assessment of Bonded and Unbonded Post-Tensioned Concrete Members
- 1 November 2015
- Published by American Concrete Institute in ACI Structural Journal
- Vol. 112 (6)
Experimental and Numerical Assessment of Bonded and Unbonded Post-Tensioned Concrete Members
- 30 April 2014
- Published by Korea Concrete Institute in Journal of the Korea Concrete Institute
- Vol. 26 (2) , 125-133
Seismic Experiment of Precast Concrete Exterior Beam-Column Joint Using Bolt Type Connection and Prestressing Method
- 30 April 2014
- Published by Korea Concrete Institute in Journal of the Korea Concrete Institute
- Vol. 26 (2) , 125-133
Seismic Experiment of Precast Concrete Exterior Beam-Column Joint Using Bolt Type Connection and Prestressing Method