BIOMECHANICAL PERFORMANCE OF A MODIFIED DESIGN OF DYNAMIC CERVICAL IMPLANT COMPARED TO CONVENTIONAL BALL AND SOCKET DESIGN OF AN ARTIFICIAL INTERVERTEBRAL DISC IMPLANT: A FINITE ELEMENT STUDY
- 25 June 2019
- journal article
- research article
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 19 (04)
Abstract
Most of the implants used for total disc replacement (TDR) surgery are designed as a ball and socket pair aimed at providing a three-dimensional unconstrained motion. However, one of the major concerns with ball and socket design is the wear of the implant which limits its life. In this study the biomechanical performance of two types of implant designs is compared — a conventional ball and socket type (Prodisc-C) and a modified design of dynamic cervical implant (DCI) using FE analysis. A 3-dimensional geometrical model of cervical spine (C1–T1) was developed using CT scan data of a middle-aged healthy male. Subsequently, using FE analysis, the ROM values were validated with the existing literature using a compressive load in combination with different physiological motions of the neck. Furthermore, FE analysis on the two implants, fitted at C5–C6 segment, showed a significant increase in the ROM of implanted segment using Prodisc and decrease in the ROM of inferior segment, but modified-DCI restored the motion of the implanted and adjacent segments. Analysis of average bone strains adjacent to the implant showed a possibility of stress shielding for Prodisc. However, higher stress distribution on the modified-DCI limited its clinical use.Keywords
This publication has 29 references indexed in Scilit:
- The Latest Lessons Learned from Retrieval Analyses of Ultra-High Molecular Weight Polyethylene, Metal-on-Metal, and Alternative Bearing Total Disc ReplacementsSeminars in Spine Surgery, 2012
- Comparison of Cervical Spine Biomechanics After Fixed- and Mobile-Core Artificial Disc ReplacementSpine, 2011
- Do design variations in the artificial disc influence cervical spine biomechanics? A finite element investigationEuropean Spine Journal, 2009
- Biomechanical effect of different lumbar interspinous implants on flexibility and intradiscal pressureEuropean Spine Journal, 2008
- Bone remodelling algorithms incorporating both strain and microdamage stimuliJournal of Biomechanics, 2007
- Biomechanical comparison between fusion of two vertebrae and implantation of an artificial intervertebral discJournal of Biomechanics, 2006
- Finite element analysis of moment-rotation relationships for human cervical spineJournal of Biomechanics, 2006
- Whiplash injuries and the potential for mechanical instabilityEuropean Spine Journal, 1998
- Uncinate processes and Luschka joints influence the biomechanics of the cervical spine: Quantification using a finite element model of the C5‐C6 segmentJournal of Orthopaedic Research, 1997
- Biomechanics of the craniocervical region: The alar and transverse ligamentsJournal of Orthopaedic Research, 1988