Dmytro Petrenko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dmytro Petrenko has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- A. Naboka
O.M. Beketov National University of Urban Economy in Kharkiv
4 shared publications - Pavlo Firsov
O.M. Beketov National University of Urban Economy in Kharkiv
3 shared publications - Alyona Lovska
Український державний університет залізничного транспорту, Україна
2 shared publications - Pavlo Rukavishnykov
Ukrainian State University of Railway Transport
2 shared publications - Sergii Panchenko
Ukrainian State University of Railway Transport
2 shared publications - Yevhen Orel
Ukrainian State University of Railway Transport
2 shared publications
Latest Publications
- 30 April 2026
- Published by Taylor & Francis in Survey Review
- Vol. 58 (410) , 1-12
Integration of geodetic measurements into infrastructure surveying technology: a comparative study of levelling and terrestrial laser scanning
- 30 April 2026
- Published by Taylor & Francis in Survey Review
- Vol. 58 (410) , 1-12
Integration of geodetic measurements into infrastructure surveying technology: a comparative study of levelling and terrestrial laser scanning
- 4 July 2025
- Published by O.M.Beketov National University of Urban Economy in Kharkiv in Municipal economy of cities
- Vol. 3 (191) , 384-389
DETERMINATION OF THE DEFORMABILITY OF THE TERIVA PRECAST-MONOLITHIC OVERLAPPING STRUCTURAL SYSTEM USING HYDROSTATIC METHOD
The scientific work is devoted to a comprehensive study of a stress-strain state of energy-efficient precast-monolithic overlapping, which has been in the process of construction for some amount of time. A practical assessment of the physical and mechanical characteristics of the materials used in construction was carried out. Statistical verification of the obtained data was carried out using the author's methodology and in accordance with the requirements of Ukrainian and European building codes. The Teriva precast-monolithic overlapping is one of such solutions. The Teriva interfloor ceiling is a high-quality alternative to expensive monolithic and standard overlapping slabs. The technology combines reliability, manufacturability, ease and quick installation without a crane. Teriva is a precast-monolithic structure consisting of load-bearing beams and hollow blocks - fillers. The assembled structure is poured with a thin (3 cm) layer of concrete and forms a lightweight interfloor ceiling. The object of the study was a section of a precast-monolithic reinforced concrete overlapping measuring 1.0×6.0 m. The precast-monolithic overlapping was tested under the action of short-term and long-term evenly distributed loads and was carried out in accordance with the method of hydraulic testing of slabs and shells, taking into account the requirements of DSTU B V.2-6-7-95. According to the given experimental program, the loading mode is set: stepwise (when assessing deformability and bearing capacity in accordance with current standards), monotonically increasing or active with subsequent unloading. The load level determines the height of the water column in the tank. Based on this method, when studying the deformability and strength of the interfloor overlapping under consideration, a stepwise loading mode was selected with each step being held in time until the devices completely stop. The step size was set within 1-2 kN/m2. The maximum design load on the floor was 8 kN/m2. To determine the deflections of the loaded overlapping, mechanical deflection gauges 6 PAO and the SIIT-3 strain gauge system with DPI-100 sensors were used, installed under the floor of the 2nd floor on the floor of the 1st floor at the most characteristic points. The SIIT-3 system is designed to measure the output signals of strain gauges with the presentation of the results in digital form. The system performs sequential polling of a given number of measuring channels; preliminary analog processing (modulation, amplification and synchronous demodulation) of the measured signals and their conversion into digital form by the push-pull integration method with subsequent display of the measurement results and the numbers of the measuring channels on a digital display. According to the results of observations, the deformation did not exceed the permissible ones (the maximum permissible deflection is 20 mm, and the actual one is 0.22 mm). At the same time, the created load level exceeded the calculated one by almost 2 times. Moreover, deformations from long-term loads also exceeded the permissible ones and amounted to about 0.22 mm. Also, no signs of destruction were found. As a conclusion, it is accepted that the bearing capacity of the floor is sufficient to withstand the loads.
- 4 July 2025
- Published by O.M.Beketov National University of Urban Economy in Kharkiv in Municipal economy of cities
- Vol. 3 (191) , 384-389
DETERMINATION OF THE DEFORMABILITY OF THE TERIVA PRECAST-MONOLITHIC OVERLAPPING STRUCTURAL SYSTEM USING HYDROSTATIC METHOD
The scientific work is devoted to a comprehensive study of a stress-strain state of energy-efficient precast-monolithic overlapping, which has been in the process of construction for some amount of time. A practical assessment of the physical and mechanical characteristics of the materials used in construction was carried out. Statistical verification of the obtained data was carried out using the author's methodology and in accordance with the requirements of Ukrainian and European building codes. The Teriva precast-monolithic overlapping is one of such solutions. The Teriva interfloor ceiling is a high-quality alternative to expensive monolithic and standard overlapping slabs. The technology combines reliability, manufacturability, ease and quick installation without a crane. Teriva is a precast-monolithic structure consisting of load-bearing beams and hollow blocks - fillers. The assembled structure is poured with a thin (3 cm) layer of concrete and forms a lightweight interfloor ceiling. The object of the study was a section of a precast-monolithic reinforced concrete overlapping measuring 1.0×6.0 m. The precast-monolithic overlapping was tested under the action of short-term and long-term evenly distributed loads and was carried out in accordance with the method of hydraulic testing of slabs and shells, taking into account the requirements of DSTU B V.2-6-7-95. According to the given experimental program, the loading mode is set: stepwise (when assessing deformability and bearing capacity in accordance with current standards), monotonically increasing or active with subsequent unloading. The load level determines the height of the water column in the tank. Based on this method, when studying the deformability and strength of the interfloor overlapping under consideration, a stepwise loading mode was selected with each step being held in time until the devices completely stop. The step size was set within 1-2 kN/m2. The maximum design load on the floor was 8 kN/m2. To determine the deflections of the loaded overlapping, mechanical deflection gauges 6 PAO and the SIIT-3 strain gauge system with DPI-100 sensors were used, installed under the floor of the 2nd floor on the floor of the 1st floor at the most characteristic points. The SIIT-3 system is designed to measure the output signals of strain gauges with the presentation of the results in digital form. The system performs sequential polling of a given number of measuring channels; preliminary analog processing (modulation, amplification and synchronous demodulation) of the measured signals and their conversion into digital form by the push-pull integration method with subsequent display of the measurement results and the numbers of the measuring channels on a digital display. According to the results of observations, the deformation did not exceed the permissible ones (the maximum permissible deflection is 20 mm, and the actual one is 0.22 mm). At the same time, the created load level exceeded the calculated one by almost 2 times. Moreover, deformations from long-term loads also exceeded the permissible ones and amounted to about 0.22 mm. Also, no signs of destruction were found. As a conclusion, it is accepted that the bearing capacity of the floor is sufficient to withstand the loads.
- Open Access
- 21 May 2025
- Published by Ukrainian State University of Science and Technologies in Science and Transport Progress
- No. 2(110),p. 119-127
Experimental Research of the Strength of an Open Wagon Hatch Cover During the Transportation of Containers in it
Purpose. The work is aimed at highlighting the peculiarities of experimental studies of the strength of a hatch cover of an open wagon loaded from a fitting stop for fastening containers. Methodology. In order to make it possible to use open wagons for container transportation, an experimental study of the hatch cover of an open wagon loaded from a fitting stop was conducted. Bench tests were conducted in the research laboratory of the “Center for Diagnostics of Transport Structures” at the Ukrainian State University of Railway Transport. The stresses that arise in the design of the hatch cover were determined using the method of electrical strain gage measurement. The installation of strain gauges was carried out according to the bridge scheme. The locations of the strain gauges on the hatch cover were determined based on the theoretically obtained stress fields that arise in the hatch cover. Before installing the strain gauges, they were calibrated. The load on the fitting stop was transmitted through a metal cup that imitated the container fitting. The maximum load transferred to the fitting stop is assumed to be 6 t (60 kN), which corresponds to the maximum loaded state of a container of standard size 1CC. The strain gauge readings were taken using a VNP-8 strain gauge station. Findings. During the research, the maximum stresses in the hatch cover were 345.4 MPa. The obtained stresses exceed the permissible ones, which allows us to conclude that it is impossible to use such a container fastening scheme in practice. The largest percentage of discrepancy between the results of computer modeling and experimental research on the strength of the hatch cover of an open wagon is about 10% and is recorded when the load on the fitting stop is 30 kN. Originality. A procedure for conducting an experimental study of the strength of the hatch cover of an open wagon under the load from the fitting stop for fastening containers is proposed. The dependence of the stresses in the hatch cover of the open wagon on the load it perceives through the fitting stop was obtained. Practical value. The conducted research will contribute to the creation of recommendations for adapting open wagons to container transportation and increasing the efficiency of container transportation.
- 21 May 2025
- Published by Ukrainian State University of Science and Technologies in Science and Transport Progress
- No. 2(110),p. 119-127
Open AccessExperimental Research of the Strength of an Open Wagon Hatch Cover During the Transportation of Containers in it
Purpose. The work is aimed at highlighting the peculiarities of experimental studies of the strength of a hatch cover of an open wagon loaded from a fitting stop for fastening containers. Methodology. In order to make it possible to use open wagons for container transportation, an experimental study of the hatch cover of an open wagon loaded from a fitting stop was conducted. Bench tests were conducted in the research laboratory of the “Center for Diagnostics of Transport Structures” at the Ukrainian State University of Railway Transport. The stresses that arise in the design of the hatch cover were determined using the method of electrical strain gage measurement. The installation of strain gauges was carried out according to the bridge scheme. The locations of the strain gauges on the hatch cover were determined based on the theoretically obtained stress fields that arise in the hatch cover. Before installing the strain gauges, they were calibrated. The load on the fitting stop was transmitted through a metal cup that imitated the container fitting. The maximum load transferred to the fitting stop is assumed to be 6 t (60 kN), which corresponds to the maximum loaded state of a container of standard size 1CC. The strain gauge readings were taken using a VNP-8 strain gauge station. Findings. During the research, the maximum stresses in the hatch cover were 345.4 MPa. The obtained stresses exceed the permissible ones, which allows us to conclude that it is impossible to use such a container fastening scheme in practice. The largest percentage of discrepancy between the results of computer modeling and experimental research on the strength of the hatch cover of an open wagon is about 10% and is recorded when the load on the fitting stop is 30 kN. Originality. A procedure for conducting an experimental study of the strength of the hatch cover of an open wagon under the load from the fitting stop for fastening containers is proposed. The dependence of the stresses in the hatch cover of the open wagon on the load it perceives through the fitting stop was obtained. Practical value. The conducted research will contribute to the creation of recommendations for adapting open wagons to container transportation and increasing the efficiency of container transportation.
- Open Access
- 2 April 2025
- Published by O.M.Beketov National University of Urban Economy in Kharkiv in Municipal economy of cities
- Vol. 1 (189) , 252-257
STUDY OF THE STRESS-STRAIN STATE OF A MONOLITHIC REINFORCED CONCRETE QUAY WALL
The scientific work is devoted to a comprehensive study of the stress-strain state of the quay wall, an industrial facility that has been under construction for a long time. A practical assessment of the physical and mechanical characteristics of the materials used in the construction was carried out. Laboratory verification of the obtained data was carried out using the current methodology and in accordance with the requirements of Ukrainian building codes. When constructing piers, materials with various properties are used: wood, concrete, reinforced concrete, steel. Often, pier structures are made of different materials. For example, the base is made of wooden or metal piles, and the deck is made of reinforced concrete. However, the most common are reinforced concrete or concrete structures. Quay wall – is a monolithic reinforced concrete structure, the basis for the construction of the pier as a whole. During a detailed inspection of the retaining wall structures, a visual inspection of the building structures, as well as its individual elements, was carried out to determine their technical condition, degree of physical wear and tear, and bearing capacity. During the field study, the retaining wall was studied in detail. The geometric characteristics of the structures were established. The results of the study show the following: during the visual inspection of the structure, some defects were found, including; the erected sections of the quay wall (1, 2, 3, 7) have a color that is not typical of high-quality concrete. The presence of some cracks. Nevertheless, the opening width is permissible within 0.3 mm. The experimental algorithm for establishing the physical and mechanical characteristics of the quay wall deformability, which has been under construction for a long time, has been improved. A comprehensive study of building structures has been carried out; the actual characteristics of materials have been determined. An additional expert analysis of the structural system of the quay wall has been carried out. Based on the results of the comprehensive theoretical and experimental studies, proposals have been made for further safe operation. The results obtained can be used by engineers in the future to establish the causes of disruptions in the technological process of production.
- 2 April 2025
- Published by O.M.Beketov National University of Urban Economy in Kharkiv in Municipal economy of cities
- Vol. 1 (189) , 252-257
Open AccessSTUDY OF THE STRESS-STRAIN STATE OF A MONOLITHIC REINFORCED CONCRETE QUAY WALL
The scientific work is devoted to a comprehensive study of the stress-strain state of the quay wall, an industrial facility that has been under construction for a long time. A practical assessment of the physical and mechanical characteristics of the materials used in the construction was carried out. Laboratory verification of the obtained data was carried out using the current methodology and in accordance with the requirements of Ukrainian building codes. When constructing piers, materials with various properties are used: wood, concrete, reinforced concrete, steel. Often, pier structures are made of different materials. For example, the base is made of wooden or metal piles, and the deck is made of reinforced concrete. However, the most common are reinforced concrete or concrete structures. Quay wall – is a monolithic reinforced concrete structure, the basis for the construction of the pier as a whole. During a detailed inspection of the retaining wall structures, a visual inspection of the building structures, as well as its individual elements, was carried out to determine their technical condition, degree of physical wear and tear, and bearing capacity. During the field study, the retaining wall was studied in detail. The geometric characteristics of the structures were established. The results of the study show the following: during the visual inspection of the structure, some defects were found, including; the erected sections of the quay wall (1, 2, 3, 7) have a color that is not typical of high-quality concrete. The presence of some cracks. Nevertheless, the opening width is permissible within 0.3 mm. The experimental algorithm for establishing the physical and mechanical characteristics of the quay wall deformability, which has been under construction for a long time, has been improved. A comprehensive study of building structures has been carried out; the actual characteristics of materials have been determined. An additional expert analysis of the structural system of the quay wall has been carried out. Based on the results of the comprehensive theoretical and experimental studies, proposals have been made for further safe operation. The results obtained can be used by engineers in the future to establish the causes of disruptions in the technological process of production.
- Open Access
- 27 June 2024
- Published by O.M.Beketov National University of Urban Economy in Kharkiv in Scientific Bulletin of Civil Engineering
- No. 110,p. 70-76
ДОСЛІДЖЕННЯ НАПРУЖЕНО-ДЕФОРМОВАНОГО СТАНУ ЗБІРНИХ ЗАЛІЗОБЕТОННИХ БАГАТОПУСТОТНИХ ПЛИТ ПРИ ДІЇ ЗОСЕРЕДЖЕНОГО І РІВНОМІРНО РОЗПОДІЛЕНОГО НАВАНТАЖЕННЯ
The scientific work is devoted to a comprehensive study of the stress-strain state of prefabricated hollow-core floor slabs, establishing the nature of deformation, as well as determining the characteristics of crack resistance, deformability and load-bearing capacity experimentally under short-term loads. The experimental data obtained were confirmed by theoretical calculations. The scientific novelty of the experiments carried out within the framework of the presented work lies in the improvement of the principles of direct design of floor slabs from commercially produced beam slabs, the possibility of determining the stress-strain behavior of a slab structure using the formed ends. The method of monitoring the stressed behavior of a slab structure was also further developed. For the first time, the results of full-scale experimental studies of the stress-strain behavior of a prefabricated slab, carried out using the hydraulic loading method, have been obtained, and the features of the deformation of a slab embedded in the wall of a multi-story building have been experimentally established. The article provides recommendations for the practical use of the research results obtained, and also develops technical specifications for the production of concrete slabs during design and construction. The developed proposals were used in the construction of residential buildings in Kharkiv. When using the recommended grade of concrete C25/30 (instead of the actual grade C20/25 tested), the rigidity of the slab increases and its deflections will be smaller. Based on the data obtained from the experimental testing of the slabs, a generally positive test result should be stated. During further serial production of slabs, periodic testing of batches of slabs should be carried out in accordance with DSTU B V.2.6-53:2008. In this case, the slabs are accepted according to the indicators of strength, rigidity, crack resistance, fire resistance limits, frost resistance limits, as well as water resistance of slabs intended for use in aggressive environments.
- 27 June 2024
- Published by O.M.Beketov National University of Urban Economy in Kharkiv in Scientific Bulletin of Civil Engineering
- No. 110,p. 70-76
Open AccessДОСЛІДЖЕННЯ НАПРУЖЕНО-ДЕФОРМОВАНОГО СТАНУ ЗБІРНИХ ЗАЛІЗОБЕТОННИХ БАГАТОПУСТОТНИХ ПЛИТ ПРИ ДІЇ ЗОСЕРЕДЖЕНОГО І РІВНОМІРНО РОЗПОДІЛЕНОГО НАВАНТАЖЕННЯ
The scientific work is devoted to a comprehensive study of the stress-strain state of prefabricated hollow-core floor slabs, establishing the nature of deformation, as well as determining the characteristics of crack resistance, deformability and load-bearing capacity experimentally under short-term loads. The experimental data obtained were confirmed by theoretical calculations. The scientific novelty of the experiments carried out within the framework of the presented work lies in the improvement of the principles of direct design of floor slabs from commercially produced beam slabs, the possibility of determining the stress-strain behavior of a slab structure using the formed ends. The method of monitoring the stressed behavior of a slab structure was also further developed. For the first time, the results of full-scale experimental studies of the stress-strain behavior of a prefabricated slab, carried out using the hydraulic loading method, have been obtained, and the features of the deformation of a slab embedded in the wall of a multi-story building have been experimentally established. The article provides recommendations for the practical use of the research results obtained, and also develops technical specifications for the production of concrete slabs during design and construction. The developed proposals were used in the construction of residential buildings in Kharkiv. When using the recommended grade of concrete C25/30 (instead of the actual grade C20/25 tested), the rigidity of the slab increases and its deflections will be smaller. Based on the data obtained from the experimental testing of the slabs, a generally positive test result should be stated. During further serial production of slabs, periodic testing of batches of slabs should be carried out in accordance with DSTU B V.2.6-53:2008. In this case, the slabs are accepted according to the indicators of strength, rigidity, crack resistance, fire resistance limits, frost resistance limits, as well as water resistance of slabs intended for use in aggressive environments.
- Open Access
- 5 April 2024
- Published by O.M.Beketov National University of Urban Economy in Kharkiv in Municipal economy of cities
- Vol. 1 (182) , 55–60
STUDY OF THE EFFECT OF HALOGENATED FIRE RETARDANTS ON REDUCING THE FLAMMABILITY OF COMPOSITE REINFORCEMENT
The article is devoted to the issue of reducing the flammability of fiberglass composite reinforcement, which is obtained based on an epoxy anhydride binder by the needle extrusion method. The authors applied halogenated epoxy resins based on tetrabromobisphenol A and chlorine-containing resin EHD (N,N-tetraglycidyl-3,3′-dichloro-4,4′-diaminodiphenylmethane) as flame retardant components (modifiers). We controlled the degree of transformation (passage of the polyaddition reaction) of epoxy systems exposed to heat under the technology conditions by the method of sol-gel analysis. The conducted research established the ability of halogenated flame retardants not to exert a directed effect on reducing the flammability of composite reinforcement obtained in the short-term mode of formation. Under these conditions, the composition of the epoxy anhydride binder is of great importance, considering the ratio of epoxy and anhydride groups in the reaction system. We determined that to achieve an increased oxygen index and a relative decrease in the flammability of composite reinforcement in the conditions of a short-term hardening regime, a small addition of flame retardant, which contains only chlorine-containing oligomer EHD, is necessary. In this particular case, we observed a characteristic anti-plasticising effect, which leads to the preservation of the modulus of elasticity of the composite material and a decrease in the flammability of the composite. With a further increase in the amount of the antipyretic modifier, structural transformations occur at the supramolecular level, which possibly prolongs the distance between the mesh nodes of the hardened matrix of the composite and contributes to a decrease in its modulus of elasticity and loss of its ability to inhibit the spontaneous combustion reaction. As a result of the plasticising effect at the supramolecular level, molecules surround the internodal structural elements of the polymer. It leads not only to a decrease in the interaction between the macromolecules of the epoxy polymer but also to an increase in the diffusion characteristics of the entire system. Keywords: fibreglass composite reinforcement, flammability, oxygen index, halogenated fire retardant.
- 5 April 2024
- Published by O.M.Beketov National University of Urban Economy in Kharkiv in Municipal economy of cities
- Vol. 1 (182) , 55–60
Open AccessSTUDY OF THE EFFECT OF HALOGENATED FIRE RETARDANTS ON REDUCING THE FLAMMABILITY OF COMPOSITE REINFORCEMENT
The article is devoted to the issue of reducing the flammability of fiberglass composite reinforcement, which is obtained based on an epoxy anhydride binder by the needle extrusion method. The authors applied halogenated epoxy resins based on tetrabromobisphenol A and chlorine-containing resin EHD (N,N-tetraglycidyl-3,3′-dichloro-4,4′-diaminodiphenylmethane) as flame retardant components (modifiers). We controlled the degree of transformation (passage of the polyaddition reaction) of epoxy systems exposed to heat under the technology conditions by the method of sol-gel analysis. The conducted research established the ability of halogenated flame retardants not to exert a directed effect on reducing the flammability of composite reinforcement obtained in the short-term mode of formation. Under these conditions, the composition of the epoxy anhydride binder is of great importance, considering the ratio of epoxy and anhydride groups in the reaction system. We determined that to achieve an increased oxygen index and a relative decrease in the flammability of composite reinforcement in the conditions of a short-term hardening regime, a small addition of flame retardant, which contains only chlorine-containing oligomer EHD, is necessary. In this particular case, we observed a characteristic anti-plasticising effect, which leads to the preservation of the modulus of elasticity of the composite material and a decrease in the flammability of the composite. With a further increase in the amount of the antipyretic modifier, structural transformations occur at the supramolecular level, which possibly prolongs the distance between the mesh nodes of the hardened matrix of the composite and contributes to a decrease in its modulus of elasticity and loss of its ability to inhibit the spontaneous combustion reaction. As a result of the plasticising effect at the supramolecular level, molecules surround the internodal structural elements of the polymer. It leads not only to a decrease in the interaction between the macromolecules of the epoxy polymer but also to an increase in the diffusion characteristics of the entire system. Keywords: fibreglass composite reinforcement, flammability, oxygen index, halogenated fire retardant.
- Open Access
- 5 April 2024
- Published by O.M.Beketov National University of Urban Economy in Kharkiv in Municipal economy of cities
- Vol. 1 (182) , 90–96
STUDY OF THE STRESS-STRAIN STATE OF A REINFORCED CONCRETE SLAB USING HYDROSTATIC METHOD
The scientific article is devoted to a complex study of the stress-strain state of a monolithic slab, implemented using the author’s method of hydrostatic loading, which involves setting the load by the weight of water and regulating its value by the height of the water column. To implement the given procedure, we used a tank-shaped facility for field tests of structures for vertical short-term and long-term loads. To determine the deflections of the loaded slab system, we installed mechanical deflection gauges of the 6PAO brand under the slab at pre-planned places. The short-term loading of the selected section of the monolithic reinforced concrete slab involved three stages. The first two stages of loading were carried out step by step, with a load step of 1–2 kN/m2 and a time delay until the arrows of the deflection gauges stopped. The maximum load on the slab was 5 kN/m2. The maximum deflection was recorded for point 2 (conventional centre of the tank) and was equal to 1.27 mm. The third stage of slab loading proceeded by analogy with the previous two. The maximum load on the slab was 8 kN/m2. The maximum deflection was recorded for point 2 and equalled 1.57 mm. After completing the stepped loading, the water tank was left on the slab to track vertical deflections for 32 days. The study experimentally established that the displacement of the examined slab in the span and support zones under increased load did not exceed the normative values. We carried out numerical verification using finite-element modelling followed by calculations in a linear and non-linear model. The theoretical and experimental calculation results showed a qualitative and quantitative data match (the difference did not exceed 15–20%). The nature of the change in the deflections remained practically linear and closely correlated with the experimental data (the values of the maximum deflections were equal to 1.16 and 1.57 mm, respectively, which was less than the maximum allowable deflection of 30 mm). Based on the results of the comprehensive study, we have made proposals for further safe operation of the investigated slab system through the use of lightweight floor elements (lighter filling, reduction of screed thickness, and others) to limit the total load on the overlapping to 10 kN/m2 (taking into account dead weight of the slab, load from floor structure and partitions, load from people and various types of construction and other equipment). Keywords: hydrostatic loading, testing, concrete, calculation, deflection, modelling.
- 5 April 2024
- Published by O.M.Beketov National University of Urban Economy in Kharkiv in Municipal economy of cities
- Vol. 1 (182) , 90–96
Open AccessSTUDY OF THE STRESS-STRAIN STATE OF A REINFORCED CONCRETE SLAB USING HYDROSTATIC METHOD
The scientific article is devoted to a complex study of the stress-strain state of a monolithic slab, implemented using the author’s method of hydrostatic loading, which involves setting the load by the weight of water and regulating its value by the height of the water column. To implement the given procedure, we used a tank-shaped facility for field tests of structures for vertical short-term and long-term loads. To determine the deflections of the loaded slab system, we installed mechanical deflection gauges of the 6PAO brand under the slab at pre-planned places. The short-term loading of the selected section of the monolithic reinforced concrete slab involved three stages. The first two stages of loading were carried out step by step, with a load step of 1–2 kN/m2 and a time delay until the arrows of the deflection gauges stopped. The maximum load on the slab was 5 kN/m2. The maximum deflection was recorded for point 2 (conventional centre of the tank) and was equal to 1.27 mm. The third stage of slab loading proceeded by analogy with the previous two. The maximum load on the slab was 8 kN/m2. The maximum deflection was recorded for point 2 and equalled 1.57 mm. After completing the stepped loading, the water tank was left on the slab to track vertical deflections for 32 days. The study experimentally established that the displacement of the examined slab in the span and support zones under increased load did not exceed the normative values. We carried out numerical verification using finite-element modelling followed by calculations in a linear and non-linear model. The theoretical and experimental calculation results showed a qualitative and quantitative data match (the difference did not exceed 15–20%). The nature of the change in the deflections remained practically linear and closely correlated with the experimental data (the values of the maximum deflections were equal to 1.16 and 1.57 mm, respectively, which was less than the maximum allowable deflection of 30 mm). Based on the results of the comprehensive study, we have made proposals for further safe operation of the investigated slab system through the use of lightweight floor elements (lighter filling, reduction of screed thickness, and others) to limit the total load on the overlapping to 10 kN/m2 (taking into account dead weight of the slab, load from floor structure and partitions, load from people and various types of construction and other equipment). Keywords: hydrostatic loading, testing, concrete, calculation, deflection, modelling.
- Open Access
- 24 May 2017
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 107, 00051
Regression equations for circular CFST columns carrying capacity evaluation
MATEC Web of Conferences, open access proceedings in Materials science, Engineering and Chemistry
- 24 May 2017
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 107, 00051
Open AccessRegression equations for circular CFST columns carrying capacity evaluation
MATEC Web of Conferences, open access proceedings in Materials science, Engineering and Chemistry