PFPavlo Firsov

Pavlo Firsov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Pavlo Firsov has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Numerical Analysis of 3D-Printed Permanent Formwork in Multi-story Building Construction

    by Petro Reznik, Anton Volodymyrov, Vladyslav Tenesesku, Pavlo Firsov


  • DETERMINATION OF THE DEFORMABILITY OF THE TERIVA PRECAST-MONOLITHIC OVERLAPPING STRUCTURAL SYSTEM USING HYDROSTATIC METHOD

    by A. Naboka, P. Firsov, D. Petrenko

    The scientific work is devoted to a comprehensive study of a stress-strain state of energy-efficient precast-monolithic overlapping, which has been in the process of construction for some amount of time. A practical assessment of the physical and mechanical characteristics of the materials used in construction was carried out. Statistical verification of the obtained data was carried out using the author's methodology and in accordance with the requirements of Ukrainian and European building codes. The Teriva precast-monolithic overlapping is one of such solutions. The Teriva interfloor ceiling is a high-quality alternative to expensive monolithic and standard overlapping slabs. The technology combines reliability, manufacturability, ease and quick installation without a crane. Teriva is a precast-monolithic structure consisting of load-bearing beams and hollow blocks - fillers. The assembled structure is poured with a thin (3 cm) layer of concrete and forms a lightweight interfloor ceiling. The object of the study was a section of a precast-monolithic reinforced concrete overlapping measuring 1.0×6.0 m. The precast-monolithic overlapping was tested under the action of short-term and long-term evenly distributed loads and was carried out in accordance with the method of hydraulic testing of slabs and shells, taking into account the requirements of DSTU B V.2-6-7-95. According to the given experimental program, the loading mode is set: stepwise (when assessing deformability and bearing capacity in accordance with current standards), monotonically increasing or active with subsequent unloading. The load level determines the height of the water column in the tank. Based on this method, when studying the deformability and strength of the interfloor overlapping under consideration, a stepwise loading mode was selected with each step being held in time until the devices completely stop. The step size was set within 1-2 kN/m2. The maximum design load on the floor was 8 kN/m2. To determine the deflections of the loaded overlapping, mechanical deflection gauges 6 PAO and the SIIT-3 strain gauge system with DPI-100 sensors were used, installed under the floor of the 2nd floor on the floor of the 1st floor at the most characteristic points. The SIIT-3 system is designed to measure the output signals of strain gauges with the presentation of the results in digital form. The system performs sequential polling of a given number of measuring channels; preliminary analog processing (modulation, amplification and synchronous demodulation) of the measured signals and their conversion into digital form by the push-pull integration method with subsequent display of the measurement results and the numbers of the measuring channels on a digital display. According to the results of observations, the deformation did not exceed the permissible ones (the maximum permissible deflection is 20 mm, and the actual one is 0.22 mm). At the same time, the created load level exceeded the calculated one by almost 2 times. Moreover, deformations from long-term loads also exceeded the permissible ones and amounted to about 0.22 mm. Also, no signs of destruction were found. As a conclusion, it is accepted that the bearing capacity of the floor is sufficient to withstand the loads.

  • Open Access

    ANALYSIS OF STRENGTH AND STIFFNESS OF PERMANENT FORMWORK BLOCKS WITH A WIDTH OF 300 TO 400 MM FOR LOW-RISE CONSTRUCTION

    by В. Є. Артьомов, I. Bilous, P. Firsov, І. І. Білоус, П. М. Фірсов

    The article investigates the structural performance of concrete blocks used as permanent formwork in low-rise construction, with widths ranging from 300 to 400 mm. These blocks serve as both formwork and part of the structural system, providing a durable solution for wall construction. In Ukraine, the adoption of such blocks is limited due to underdeveloped reinforcement methodologies, which complicates their application in construction projects. The authors examine the strength and stiffness of a standard block with dimensions of 500×400×200 mm, using software-based modeling in TechEditor to streamline the calculations. This research produces graphical data on load-bearing capacity and bending stiffness, which designers can use to configure reinforced concrete walls with these blocks. The study also offers practical reinforcement guidance, filling gaps in current standards and assisting engineers in implementing these blocks effectively. Permanent formwork blocks, common internationally, typically contain voids and channels that facilitate rebar installation, creating a monolithic structure after the concrete sets. However, due to inconsistencies in reinforcement advice from manufacturers, Ukrainian engineers often resort to custom approaches or traditional monolithic construction. This study, therefore, aims to address these challenges by providing structured reinforcement recommendations. The research includes load-bearing and stiffness calculations for walls with variable depth (300-400 mm), accounting for different rebar diameters to simulate the range of possible configurations. Findings demonstrate that using blocks with rebar yields significant material savings (approximately 33% less concrete) compared to solid walls, without proportionate strength loss, making them a cost-effective choice for low-rise construction. In conclusion, the article offers engineers and manufacturers valuable insights into the practical use of permanent formwork blocks, presenting a foundation for further research into optimization and broader applications. Keywords: reinforced concrete, block, formwork, reinforcement, analysis.

  • Open Access

    STUDY OF DEFORMABILITY OF THE LARGE-SPAN ROOF STRUCTURAL SYSTEM IN THE FORM OF AN ASYMMETRICAL SHELL

    by A. Naboka, P. Firsov

    The scientific article is devoted to a complex study of deformability of saddle-type shell of negative Gaussian curvature of a public object that has been in operation for a long time for further general restoration of the building’s roofing system. The authors have developed a specific algorithm for conducting experimental research, providing additional static load on a shell at the lower point of the gentle axial line of the supporting arches. To smoothly carry out the loading procedure, we mounted containers in barrel form on the roof surface and gradually filled them with water. We carried out an experimental evaluation of the bearing capacity of the shell with the determination of the redistribution of forces along the length of the section in the lower zone of the conventionally outlined arch. The experimental test results revealed that the deformability of the shell surface under short-term loading did not exceed 2.0 mm, and, under long-term loading, it was no more than 4.0 mm. Analysis of the qualitative features of structure deformation shows that the displacement of the roof’s points, located symmetrically to the vertical axis, has the opposite sign to the sign of the displacement of the actual ‘saddle’ point (the case of symmetrical deformation). We conducted a numerical verification of the behaviour of the investigated structure by forming a detailed finite element spatial model of the shell. Comparison of the results of numerical calculation with the results of field tests shows the coincidence of qualitative and quantitative parameters, which, in turn, characterises the developed theoretical model as fully adequate and suitable for analysing the stress-strain state of similar large-span structural systems. Based on the results of comprehensive theoretical and experimental research, we made proposals for the further restoration of the roofing structure with the limitation of the self-weight of the covering to 1 kN/m2. Engineers and scientists can use the research results to reconstruct similar authentic structural systems. Keywords: calculation, restoration, loading, deflection, shell, negative Gaussian curvature.


  • Open Access

    STUDY OF THE EFFECT OF HALOGENATED FIRE RETARDANTS ON REDUCING THE FLAMMABILITY OF COMPOSITE REINFORCEMENT

    by P. Bilym, P. Firsov, A. Rohozin, D. Petrenko

    The article is devoted to the issue of reducing the flammability of fiberglass composite reinforcement, which is obtained based on an epoxy anhydride binder by the needle extrusion method. The authors applied halogenated epoxy resins based on tetrabromobisphenol A and chlorine-containing resin EHD (N,N-tetraglycidyl-3,3′-dichloro-4,4′-diaminodiphenylmethane) as flame retardant components (modifiers). We controlled the degree of transformation (passage of the polyaddition reaction) of epoxy systems exposed to heat under the technology conditions by the method of sol-gel analysis. The conducted research established the ability of halogenated flame retardants not to exert a directed effect on reducing the flammability of composite reinforcement obtained in the short-term mode of formation. Under these conditions, the composition of the epoxy anhydride binder is of great importance, considering the ratio of epoxy and anhydride groups in the reaction system. We determined that to achieve an increased oxygen index and a relative decrease in the flammability of composite reinforcement in the conditions of a short-term hardening regime, a small addition of flame retardant, which contains only chlorine-containing oligomer EHD, is necessary. In this particular case, we observed a characteristic anti-plasticising effect, which leads to the preservation of the modulus of elasticity of the composite material and a decrease in the flammability of the composite. With a further increase in the amount of the antipyretic modifier, structural transformations occur at the supramolecular level, which possibly prolongs the distance between the mesh nodes of the hardened matrix of the composite and contributes to a decrease in its modulus of elasticity and loss of its ability to inhibit the spontaneous combustion reaction. As a result of the plasticising effect at the supramolecular level, molecules surround the internodal structural elements of the polymer. It leads not only to a decrease in the interaction between the macromolecules of the epoxy polymer but also to an increase in the diffusion characteristics of the entire system. Keywords: fibreglass composite reinforcement, flammability, oxygen index, halogenated fire retardant.

  • Open Access

    STUDY OF THE STRESS-STRAIN STATE OF A REINFORCED CONCRETE SLAB USING HYDROSTATIC METHOD

    by A. Naboka, P. Reznik, D. Petrenko, P. Firsov

    The scientific article is devoted to a complex study of the stress-strain state of a monolithic slab, implemented using the author’s method of hydrostatic loading, which involves setting the load by the weight of water and regulating its value by the height of the water column. To implement the given procedure, we used a tank-shaped facility for field tests of structures for vertical short-term and long-term loads. To determine the deflections of the loaded slab system, we installed mechanical deflection gauges of the 6PAO brand under the slab at pre-planned places. The short-term loading of the selected section of the monolithic reinforced concrete slab involved three stages. The first two stages of loading were carried out step by step, with a load step of 1–2 kN/m2 and a time delay until the arrows of the deflection gauges stopped. The maximum load on the slab was 5 kN/m2. The maximum deflection was recorded for point 2 (conventional centre of the tank) and was equal to 1.27 mm. The third stage of slab loading proceeded by analogy with the previous two. The maximum load on the slab was 8 kN/m2. The maximum deflection was recorded for point 2 and equalled 1.57 mm. After completing the stepped loading, the water tank was left on the slab to track vertical deflections for 32 days. The study experimentally established that the displacement of the examined slab in the span and support zones under increased load did not exceed the normative values. We carried out numerical verification using finite-element modelling followed by calculations in a linear and non-linear model. The theoretical and experimental calculation results showed a qualitative and quantitative data match (the difference did not exceed 15–20%). The nature of the change in the deflections remained practically linear and closely correlated with the experimental data (the values of the maximum deflections were equal to 1.16 and 1.57 mm, respectively, which was less than the maximum allowable deflection of 30 mm). Based on the results of the comprehensive study, we have made proposals for further safe operation of the investigated slab system through the use of lightweight floor elements (lighter filling, reduction of screed thickness, and others) to limit the total load on the overlapping to 10 kN/m2 (taking into account dead weight of the slab, load from floor structure and partitions, load from people and various types of construction and other equipment). Keywords: hydrostatic loading, testing, concrete, calculation, deflection, modelling.


  • Open Access

    ANALYSIS OF CRACK FORMATION AND DEFORMABILITY OF BENT CONCRETE STRUCTURES REINFORCED WITH COMPOSITE REINFORCEMENT

    by P. Firsov, S. Zolotov, S. Nadtochii

    The scientific article is devoted to analysing the existing regulatory methods for calculating bending concrete structures reinforced with non-metallic composite reinforcement (FRP) according to deformations and crack formation (second group of limit states). It is known that FRP composite reinforcement does not behave in the same way as steel reinforcement, since, in many cases, their mechanical properties differ significantly. The existing foreign and Ukrainian norms and recommendations for calculating constructions with FRP reinforcement are mostly modifications of the norms for calculating reinforced concrete structures with steel reinforcement. The changes are mainly related to the rationing of the physical and mechanical properties of composite reinforcement and several empirical ratios. According to the recommendations of foreign standards, we considered the model of a beam with combined reinforcement (steel + GFRP) to carry out calculations for predicting the formation of cracks. The results of laboratory tests of an experimental beam with FRP reinforcement were compared with the results of theoretical calculations for predicting crack formation following the recommendations of the current foreign standards Eurocode 2 and ACI 440.1R-15. When comparing the results, it is clear that EC2 provides more approximate predictions of the cracking load than ACI. Deflections in the middle of the beam span from the moment of crack formation to the moment of destruction were determined. An experimental ‘load–deflection’ curve was constructed. The ratio between the experimental and predicted values of deflections using the EC2 and ACI methods was determined. According to the calculated data, both standards provide a sufficiently approximate forecast at 0,3Pult. The results of the research can be used in the future for the design of concrete structures reinforced with non-metallic composite reinforcement (based on glass fibres, basalt, carbon, aramid, etc.), however, further studies of structural elements working in bending under different load conditions and statistically justified confirmation are required.

  • Open Access

    THEORETICAL ASPECTS OF AVOIDING DELAMINATION OF COMPOSITE MATERIALS DURING STRENGTHENING OF REINFORCED CONCRETE STRUCTURES

    by P. Firsov, Bachar Ali Kaafarani, Р. Firsov

    The scientific work is devoted to the improvement of the calculation methodology of reinforced concrete elements, using verification of the FRP delamination prevention, during structures strengthening with a system of composite materials (SCM) from various fibers types. During strengthening of reinforced concrete elements with composite material systems, the role of adhesion between concrete and FRP is of great importance due to the fragility of the failure mechanism due to delamination (loss of adhesion). The adhesion strength is generally much higher than the tensile strength of the concrete, so delamination always starts in concrete itself with the separation of FRP layer of different thickness. According to the load-bearing capacity requirements, such a failure mechanism should not precede the failure of the strengthened element during bending or shear. To solve the problem of possible strengthening delamination of composite materials systems, it is necessary to consider different failure modes of FRP. Due to imperfection of domestic building codes, a detailed analysis of the solution to the problem of FRP delamination was carried out in accordance with the recommendations of a number of foreign regulatory documents (ACI, CNR, FIB). The main failure modes, with subsequent initiation of delamination of FRP material from concrete base, are systematized, namely: FRP delamination due to surface irregularities, separation of FRP due to shear cracks, longitudinal shear stresses in the yield zone, excessive deformations in FRP material (FRP rupture), longitudinal shear stresses near the FRP edges, failure in anchoring (fixing) zone of FRP material. Six criterions are proposed that need to be verified during design of structures strengthening systems with FRP materials. During formulation of specified criterions, the main theoretical aspects necessary for application in structural calculations of the studied connection are given. The results of research can be used in future during the design of structures joints strengthening with systems of composite materials based on carbon fibers, glass, aramid. Keywords: system of composite materials, external reinforcement, FRP strengthening, reinforced concrete, failure mode, calculation, delamination.

  • Open Access

    CALCULATION METHOD FOR DETERMINATION OF ADHESION LEVEL OF COMPOSITE REINFORCEMENT WITH CONCRETE

    by P. Firsov, S. Zolotov, S. Nadtochiy

    The scientific work is devoted to the interaction process of concrete and composite reinforcement, which is characterized by “adhesion-slip” dependence. It is known, that composite reinforcement does not behave in the same way as traditional steel reinforcement, because in some cases their mechanical properties differ significantly. CFRP/FGRP/BFRP products have higher strength, but a lower modulus of elasticity, so direct replacement of steel with such reinforcement is not always possible according to many constructional requirements. Adhesion forces create a complex stress-strain condition in concrete interacting with reinforcement. This condition leads to the distribution of loads along the axis of reinforcement, and, as a result, the longitudinal forces on reinforcement become variable along the entire length of the rod. A detailed analysis of the existing approaches to the problem of adhesion level of concrete and composite reinforcement is performed in article. It was determined that the complex multiparameter state of the interaction of concrete and composite reinforcement is characterized by the corresponding curves of “adhesion-slip” dependence, which can be obtained by two experimental methods (beam test method and direct pull-out test method). A theoretical research of the adhesion level of concrete and composite reinforcement (beyond the limits of cracks formation) was carried out, connected with the analysis of the distribution of deformations of concrete and reinforcement along the span of the element. Current analysis is based on the determination of a number of differential equations with a step-by-step description of adhesion level problems. The results of research can be used in future during the design and calculation of concrete structures reinforced with different types of composite reinforcement (based on basalt, glass, carbon fibers etc.), however, it is necessary to conduct further experiments into the long-term operation (behavior) of composite reinforcement over time under the influence of various factors, to establish a number of rheological aspects.

  • Open Access

    INCREASING OF THE CORROSION RESISTANCE OF FIBERGLASS PLASTIC REINFORCEMENT THROUGH MODIFICATION OF THE POLYMER BINDER

    by P. Bilym, P. Firsov, S. Nadtochiy, Р. Bilym, Р. Firsov

    The issue of increasing the corrosion resistance of composite reinforcement, based on glass fiber and epoxy anhydride binder, is considered. The proposed samples of composite reinforcement were manufactured by needle extrusion technology. Glass fibers were evenly distributed in the channels and impregnated with a polymer binder based on epoxy resin. The amount of phenolic modifier in the polymer binder, according to the technological mode of obtaining composite reinforcement, was brought up to 5%. With a further increase in the content of the modifier, the degree of conversion of epoxy groups was no more than 70%, which sharply reduced the operational characteristics of the material. The overall ratio of polymer binder and glass reinforcement in the composite was ~ 60÷40. It was established that at low concentrations of the polymer modifier (up to 5 wt. parts), the processes of ordering and chemical grafting lead to compaction of the molecular grouping in the system, which in our case is characteristic of phenolic resins of the novolach and resol types. At the same time, under the conditions of the production technology, internal stresses in materials of this type increase sharply, which leads to the formation of surface defects (microcracks). At the tip of a crack or defect, sodium ions or other cations under the action of water undergo hydrolysis to form metal hydroxide, which, in turn, causes hydrolysis of siloxane bonds, thus weakening the mesh structure of silicon dioxide. The experimental activation energy was identified with the activation energy of sodium ion diffusion in the glass mass. But the plastic deformation of the glass in the region before the crack is very small, and instead of a uniform distribution of stress, the material cracks along the weakened centers The obtained data indicate that the action of the alkaline environment causes an increased loss of mass of the composite, both for the unmodified and for those modified with traditional phenolic resins. In turn, this ensures a high degree of penetration of alkalis into the volume of the material, access to reinforced fibers with their subsequent damage. To increase the corrosion resistance of composite reinforcement based on an epoxy anhydride binder, it is advisable to use a reactive sulfur-containing phenolic modifier. Its action is based on the ability to maintain the permissible monolithicity of fiberglass in the alkaline environment of concrete, the modulus of elasticity and necessary strength. Keywords: composite polymer reinforcement, fiberglass, alkaline environment, phenolic modifier.