Rajendran Siva Chidambaram
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rajendran Siva Chidambaram has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Pankaj Agarwal
Indian Inst Technol Roorkee, Dept Earthquake Engn, Roorkee 247667, Uttar Pradesh, India
7 shared publications- Mohan Lal
Research Scholar, Academy of Scientific and Innovative Research, Ghaziabad 201002, India; Council of Scientific and Industrial Research-Central Building Research Institute, Roorkee 247667, India. ORCID:
3 shared publications - Naveen Kumar Kothapalli
Department of Earthquake Engineering, Indian Institute of Technology Roorkee, Roorkee, India
2 shared publications - Pankaj Agarwal
Department of Earthquake Engineering Indian Institute of Technology Roorkee Roorkee India
2 shared publications - Vijay Tarun Kumar Moka
Academy of Scientific and Innovative Research
2 shared publications A. B. Danie Roy
Thapar Institute of Engineering and Technology
1 shared publication
Latest Publications
- 1 February 2027
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Design and Construction Practice
- Vol. 32 (1) , 04026110
Flexural Behavior of RC Beams Externally Strengthened Using High-Performance Fiber Grid–Reinforced Concrete
The deterioration of reinforced concrete (RC) structures due to various factors significantly reduces their design life and can lead to catastrophic failure. Upgrading and strengthening are essential for deteriorated RC structures. Various strengthening techniques, such as RC jacketing, steel jacketing, and the fiber-reinforced polymers (FRP) technique, have been used to enhance flexural and shear strength. However, these methods have certain drawbacks, including durability issues with RC and steel jacketing, as well as delamination and debonding of FRP from the concrete substrate, particularly at elevated temperatures, which limits their application in many structures. This study primarily focuses on utilizing high-performance and high-strength grids, such as textile reinforcement with steel fiber-reinforced concrete (SFRC), to extend the service life of damaged and deteriorated RC beams. The experimental work investigates the effectiveness of flexural strengthening in deficient RC beams using two different type of textiles (glass fiber textile and geogrid) and the SFRC-based hybrid textile reinforcement concrete system (HTRC), offering an improved strengthening solution for RC beams. This study also addresses delamination and debonding issues associated with the externally bonded strengthening systems. The RC beams are strengthened using the proposed HTRC system and tested under static four-point loading. The test results include load-deflection behavior, cracking and failure mode analysis using digital image correlation, HTRC strain analysis, and various performance parameters such as the stiffness and strength degradation, energy absorbed, ductility, and damage index. The findings of this study demonstrate that HTRC as externally bonded strengthening system effectively restores design life capacity and enhances the overall structural performance.
- 1 February 2027
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Design and Construction Practice
- Vol. 32 (1) , 04026110
Flexural Behavior of RC Beams Externally Strengthened Using High-Performance Fiber Grid–Reinforced Concrete
The deterioration of reinforced concrete (RC) structures due to various factors significantly reduces their design life and can lead to catastrophic failure. Upgrading and strengthening are essential for deteriorated RC structures. Various strengthening techniques, such as RC jacketing, steel jacketing, and the fiber-reinforced polymers (FRP) technique, have been used to enhance flexural and shear strength. However, these methods have certain drawbacks, including durability issues with RC and steel jacketing, as well as delamination and debonding of FRP from the concrete substrate, particularly at elevated temperatures, which limits their application in many structures. This study primarily focuses on utilizing high-performance and high-strength grids, such as textile reinforcement with steel fiber-reinforced concrete (SFRC), to extend the service life of damaged and deteriorated RC beams. The experimental work investigates the effectiveness of flexural strengthening in deficient RC beams using two different type of textiles (glass fiber textile and geogrid) and the SFRC-based hybrid textile reinforcement concrete system (HTRC), offering an improved strengthening solution for RC beams. This study also addresses delamination and debonding issues associated with the externally bonded strengthening systems. The RC beams are strengthened using the proposed HTRC system and tested under static four-point loading. The test results include load-deflection behavior, cracking and failure mode analysis using digital image correlation, HTRC strain analysis, and various performance parameters such as the stiffness and strength degradation, energy absorbed, ductility, and damage index. The findings of this study demonstrate that HTRC as externally bonded strengthening system effectively restores design life capacity and enhances the overall structural performance.
- 6 November 2026
- Published by Wiley in Structural Concrete
Influence of anchorage on the behavior of geogrid‐textile‐reinforced concrete strengthened RC beams
The present experimental study investigates the use of geogrid as a reinforcement material in textile reinforced concrete (TRC), and it evaluates the behavior of reinforced concrete (RC) beams strengthened with geogrid textile‐based TRC systems. In this study, three different RC beam configurations, strengthened with TRC with and without hybridization, were examined using two types of geogrid and a glass fiber textile. The tensile behavior of all three textile‐based TRC systems was studied. An end anchorage technique, examined through a direct‐shear‐bond test with the concrete substrate, was introduced to prevent premature debonding of TRC layers and to ensure effective utilization of geogrid reinforcement. All beams were tested under static four‐point loading to evaluate their flexural behavior. The performance of the specimens was compared using parameters such as stiffness and strength degradation, energy dissipation, displacement ductility, and damage index. Digital image correlation was employed to monitor crack propagation and strain distribution throughout the test. Failure modes and cracking patterns were critically analyzed. The results demonstrate that geogrid textile holds strong potential as a reinforcement for TRC, significantly enhancing strength, ductility, damage tolerance capacity, and post‐peak behavior.
- 6 November 2026
- Published by Wiley in Structural Concrete
Influence of anchorage on the behavior of geogrid‐textile‐reinforced concrete strengthened RC beams
The present experimental study investigates the use of geogrid as a reinforcement material in textile reinforced concrete (TRC), and it evaluates the behavior of reinforced concrete (RC) beams strengthened with geogrid textile‐based TRC systems. In this study, three different RC beam configurations, strengthened with TRC with and without hybridization, were examined using two types of geogrid and a glass fiber textile. The tensile behavior of all three textile‐based TRC systems was studied. An end anchorage technique, examined through a direct‐shear‐bond test with the concrete substrate, was introduced to prevent premature debonding of TRC layers and to ensure effective utilization of geogrid reinforcement. All beams were tested under static four‐point loading to evaluate their flexural behavior. The performance of the specimens was compared using parameters such as stiffness and strength degradation, energy dissipation, displacement ductility, and damage index. Digital image correlation was employed to monitor crack propagation and strain distribution throughout the test. Failure modes and cracking patterns were critically analyzed. The results demonstrate that geogrid textile holds strong potential as a reinforcement for TRC, significantly enhancing strength, ductility, damage tolerance capacity, and post‐peak behavior.
- 1 January 2026
- Published by Springer Nature
- p. 260-273
Flexural Behaviour of Damaged RC Beams at Elevated Temperature Strengthened with Glass Fiber Textile Reinforced Composite
- 1 January 2026
- Published by Springer Nature
- p. 260-273
Flexural Behaviour of Damaged RC Beams at Elevated Temperature Strengthened with Glass Fiber Textile Reinforced Composite
- 4 August 2025
- Published by Wiley in Structural Concrete
- Vol. 27 (1) , 528-548
Flexural performance of precast beam‐beam connections with shear key and composites
The present study focused on novel wet precast beam‐beam connections with simplified mechanisms. The experimental program examines the influence of various factors such as rebar coupler length and placement, type of cast‐in‐situ mix, shear key, and interface coating between the precast element and new concrete. Three types of connection configurations are tested under three‐point bending loading to evaluate their structural behavior. The experimental results are discussed in terms of load‐deflection behavior, crack patterns, stiffness degradation, strength degradation, damage index, and energy dissipation, etc. Failure patterns revealed that a 120‐mm coupler in Type I specimens experienced rebar slip from the sleeve, while increasing the length of couplers to 160 mm facilitated rebar yielding. The inappropriate spacing between the coupler and element interface (termed as play area) shifted the failure towards the interface due to the inherent stiffness of the coupler. The absence of the shear key induced premature interface failure, with a notable 38% reduction in load carrying capacity compared to the control specimen. In contrast, the synergetic action of the longer coupler, wet cast‐in‐situ mix, shear key, and interface coating in Type II and Type III connections resembled the overall performance comparable to the monolithic specimen. The bond coat between old and fresh concrete along with the shear key is effective in delaying the interface cracking.
- 4 August 2025
- Published by Wiley in Structural Concrete
- Vol. 27 (1) , 528-548
Flexural performance of precast beam‐beam connections with shear key and composites
The present study focused on novel wet precast beam‐beam connections with simplified mechanisms. The experimental program examines the influence of various factors such as rebar coupler length and placement, type of cast‐in‐situ mix, shear key, and interface coating between the precast element and new concrete. Three types of connection configurations are tested under three‐point bending loading to evaluate their structural behavior. The experimental results are discussed in terms of load‐deflection behavior, crack patterns, stiffness degradation, strength degradation, damage index, and energy dissipation, etc. Failure patterns revealed that a 120‐mm coupler in Type I specimens experienced rebar slip from the sleeve, while increasing the length of couplers to 160 mm facilitated rebar yielding. The inappropriate spacing between the coupler and element interface (termed as play area) shifted the failure towards the interface due to the inherent stiffness of the coupler. The absence of the shear key induced premature interface failure, with a notable 38% reduction in load carrying capacity compared to the control specimen. In contrast, the synergetic action of the longer coupler, wet cast‐in‐situ mix, shear key, and interface coating in Type II and Type III connections resembled the overall performance comparable to the monolithic specimen. The bond coat between old and fresh concrete along with the shear key is effective in delaying the interface cracking.
- Open Access
- 1 January 2024
- Published by Wiley in Advances in Civil Engineering
- Vol. 2024 (1)
Performance Evaluation of Hybrid Fiber‐Reinforced Inorganic Mortar for Textile‐Reinforced Mortar Applications
The need to improve existing structures has led to extensive research on strengthening techniques. Textile‐reinforced mortar (TRM) systems, which involve the integration of high‐strength fibers with inorganic matrix, have emerged as a highly promising and viable alternative. The objective of this research is to investigate the mechanical characteristics of inorganic mortar by examining different compositions involving sand, fibers, and cementitious materials. Various combinations were tested to evaluate their compressive strength, split tensile strength, and flexural strength. The findings indicated that a composite mixture (sample 12) comprising microsilica, silica sand, and optimized fibers demonstrated enhanced strength in all three assessments. Research highlights the significance of accurate mixing, additional components, and appropriate fibers to achieve intended performance of the mortar. The compatibility of the mortar is checked with substrate surface and textile sheet. Mortar is evaluated for splitting bond strength, slant shear test, direct pull‐off bond strength, and pull‐out strength. These results provide information about the strength and bonding characteristics of the mortar in different test scenarios. Values indicate how well the mortar performs with the substrate surface and the textile sheet under various types of stresses and loading conditions.
- 1 January 2024
- Published by Wiley in Advances in Civil Engineering
- Vol. 2024 (1)
Open AccessPerformance Evaluation of Hybrid Fiber‐Reinforced Inorganic Mortar for Textile‐Reinforced Mortar Applications
The need to improve existing structures has led to extensive research on strengthening techniques. Textile‐reinforced mortar (TRM) systems, which involve the integration of high‐strength fibers with inorganic matrix, have emerged as a highly promising and viable alternative. The objective of this research is to investigate the mechanical characteristics of inorganic mortar by examining different compositions involving sand, fibers, and cementitious materials. Various combinations were tested to evaluate their compressive strength, split tensile strength, and flexural strength. The findings indicated that a composite mixture (sample 12) comprising microsilica, silica sand, and optimized fibers demonstrated enhanced strength in all three assessments. Research highlights the significance of accurate mixing, additional components, and appropriate fibers to achieve intended performance of the mortar. The compatibility of the mortar is checked with substrate surface and textile sheet. Mortar is evaluated for splitting bond strength, slant shear test, direct pull‐off bond strength, and pull‐out strength. These results provide information about the strength and bonding characteristics of the mortar in different test scenarios. Values indicate how well the mortar performs with the substrate surface and the textile sheet under various types of stresses and loading conditions.
- 28 July 2023
- Published by Springer Nature
- p. 627-637
Experimental Investigation on Flexural Behavior of Precast Beam–Beam Connections Using Mechanical Connectors
- 28 July 2023
- Published by Springer Nature
- p. 627-637
Experimental Investigation on Flexural Behavior of Precast Beam–Beam Connections Using Mechanical Connectors
- 4 November 2022
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 27 (12) , 3564-3587
Experimental Evaluation of Steel Bracings and Metallic Yield Damper as Retrofit Techniques for Severely Damaged RC Building Frames
The concentrically placed hollow circular steel bracings and hybrid metallic yield dampers as structural retrofitting techniques for severely damaged reinforced concrete (RC) portal frames are evaluated under reverse-cyclic load conditions. In addition, the efficiency of a specially designed coupler-box assembly to retrofit severely damaged columns of the model frame by reconnecting the buckled or ruptured longitudinal reinforcing bars at the plastic hinge locations is evaluated under similar load conditions. Competency of the proposed techniques is assessed by comparing the hysteresis behavior, performance index parameters, and failure mechanism of the retrofitted frames with the native-tested conventional bare frame. The lateral load and deformation capacities are significantly enhanced in the retrofitted frames with a comprehensive increase of 2.0 times in the braced frame and 2.5 times in the damper-equipped frame compared to the conventional bare frame. A stable and symmetric post-yield behavior is noticed in the retrofitted frames until a lateral drift of 3.5% and 6% in braced and damper-fit frames, respectively, which is even higher than the collapse prevention drift level specified in FEMA codal guidelines.
- 4 November 2022
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 27 (12) , 3564-3587
Experimental Evaluation of Steel Bracings and Metallic Yield Damper as Retrofit Techniques for Severely Damaged RC Building Frames
The concentrically placed hollow circular steel bracings and hybrid metallic yield dampers as structural retrofitting techniques for severely damaged reinforced concrete (RC) portal frames are evaluated under reverse-cyclic load conditions. In addition, the efficiency of a specially designed coupler-box assembly to retrofit severely damaged columns of the model frame by reconnecting the buckled or ruptured longitudinal reinforcing bars at the plastic hinge locations is evaluated under similar load conditions. Competency of the proposed techniques is assessed by comparing the hysteresis behavior, performance index parameters, and failure mechanism of the retrofitted frames with the native-tested conventional bare frame. The lateral load and deformation capacities are significantly enhanced in the retrofitted frames with a comprehensive increase of 2.0 times in the braced frame and 2.5 times in the damper-equipped frame compared to the conventional bare frame. A stable and symmetric post-yield behavior is noticed in the retrofitted frames until a lateral drift of 3.5% and 6% in braced and damper-fit frames, respectively, which is even higher than the collapse prevention drift level specified in FEMA codal guidelines.
- 15 July 2022
- Published by Springer Nature
- p. 180-187
Performance Evaluation of Retrofitted Exterior Beam Column Joint Under Cyclic Loading
- 15 July 2022
- Published by Springer Nature
- p. 180-187
Performance Evaluation of Retrofitted Exterior Beam Column Joint Under Cyclic Loading
- 15 July 2022
- Published by Springer Nature
- p. 213-225
Flexural Behavior of RC Beams Strengthened with Textile Reinforced Concrete
- 15 July 2022
- Published by Springer Nature
- p. 213-225
Flexural Behavior of RC Beams Strengthened with Textile Reinforced Concrete
- 8 June 2022
- Published by Springer Nature
- p. 321-335
Shear Resistance Behavior of Exterior Beam-Column Joint with Steel Fiber Reinforced Concrete
- 8 June 2022
- Published by Springer Nature
- p. 321-335
Shear Resistance Behavior of Exterior Beam-Column Joint with Steel Fiber Reinforced Concrete