Naveen Kumar Kothapalli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Naveen Kumar Kothapalli has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Pankaj Agarwal
Department of Earthquake Engineering Indian Institute of Technology Roorkee Roorkee India
2 shared publications - Rajendran Siva Chidambaram
Associate Professor and Principal Scientist, Academy of Scientific and Innovative Research, Ghaziabad 201002, India; Advanced Concrete, Steel and Composites, Council of Scientific and Industrial Research-Central Building Research Institute, Roorkee 247667, India. ORCID:
2 shared publications Siva Chidambaram Rajendran
1 shared publicationV Satyanarayana K.
1 shared publication
Latest Publications
- 4 November 2022
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 27 (12) , 3564-3587
Experimental Evaluation of Steel Bracings and Metallic Yield Damper as Retrofit Techniques for Severely Damaged RC Building Frames
The concentrically placed hollow circular steel bracings and hybrid metallic yield dampers as structural retrofitting techniques for severely damaged reinforced concrete (RC) portal frames are evaluated under reverse-cyclic load conditions. In addition, the efficiency of a specially designed coupler-box assembly to retrofit severely damaged columns of the model frame by reconnecting the buckled or ruptured longitudinal reinforcing bars at the plastic hinge locations is evaluated under similar load conditions. Competency of the proposed techniques is assessed by comparing the hysteresis behavior, performance index parameters, and failure mechanism of the retrofitted frames with the native-tested conventional bare frame. The lateral load and deformation capacities are significantly enhanced in the retrofitted frames with a comprehensive increase of 2.0 times in the braced frame and 2.5 times in the damper-equipped frame compared to the conventional bare frame. A stable and symmetric post-yield behavior is noticed in the retrofitted frames until a lateral drift of 3.5% and 6% in braced and damper-fit frames, respectively, which is even higher than the collapse prevention drift level specified in FEMA codal guidelines.
- 4 November 2022
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 27 (12) , 3564-3587
Experimental Evaluation of Steel Bracings and Metallic Yield Damper as Retrofit Techniques for Severely Damaged RC Building Frames
The concentrically placed hollow circular steel bracings and hybrid metallic yield dampers as structural retrofitting techniques for severely damaged reinforced concrete (RC) portal frames are evaluated under reverse-cyclic load conditions. In addition, the efficiency of a specially designed coupler-box assembly to retrofit severely damaged columns of the model frame by reconnecting the buckled or ruptured longitudinal reinforcing bars at the plastic hinge locations is evaluated under similar load conditions. Competency of the proposed techniques is assessed by comparing the hysteresis behavior, performance index parameters, and failure mechanism of the retrofitted frames with the native-tested conventional bare frame. The lateral load and deformation capacities are significantly enhanced in the retrofitted frames with a comprehensive increase of 2.0 times in the braced frame and 2.5 times in the damper-equipped frame compared to the conventional bare frame. A stable and symmetric post-yield behavior is noticed in the retrofitted frames until a lateral drift of 3.5% and 6% in braced and damper-fit frames, respectively, which is even higher than the collapse prevention drift level specified in FEMA codal guidelines.
- 1 June 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 26 (3) , 04022016
Cyclic Evaluation of Severely Damaged RC Frames Repaired and Strengthened through FRP-Wrapped Coupler-Box Confinement
The present study is focused on the retrofitting solution and its verification through experimental investigation for the two most common catastrophic modes of failure in reinforced concrete (RC) frame buildings, namely, buckling of reinforcing bars in the plastic hinge region of columns and shear failure of beam–column joints. The first mode of failure is retrofitted with interlinked coupler-box assemblies, while the second mode is repaired with external carbon fiber–reinforced polymer (CFRP) wrapping. The efficiency of the proposed retrofitting technique is evaluated by the hysteresis behavior, failure mechanism, and performance index parameters of the re-established frame, which are compared with the results of the initially tested bare frame. The recommended mechanism restricts the restored frame section against any possible movement or rotation and helps by a subsequent shift in yield location. The prime advantage of the proposed technique is that it prevents the possible slip of rebar from the sleeve, which is intercepted by the interlinking process, and eliminates the formation of inclined shear cracks at beam–column joints restricted by externally wrapped CFRP composites. The synergic effect of coupler-box and CFRP enhances the overall performance of the re-established frame by keeping the frame sections intact even after a lateral drift of 6%, which is relatively higher than the collapse prevention drift level, i.e., 4% as per FEMA guidelines. The obtained test results reveal the capability of CFRP and coupler-box assemblage as a possible futuristic approach for retrofitting outmoded RC building frames, in which buckling in longitudinal rebars of columns at their respective plastic hinge locations is inevitable.
- 1 June 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 26 (3) , 04022016
Cyclic Evaluation of Severely Damaged RC Frames Repaired and Strengthened through FRP-Wrapped Coupler-Box Confinement
The present study is focused on the retrofitting solution and its verification through experimental investigation for the two most common catastrophic modes of failure in reinforced concrete (RC) frame buildings, namely, buckling of reinforcing bars in the plastic hinge region of columns and shear failure of beam–column joints. The first mode of failure is retrofitted with interlinked coupler-box assemblies, while the second mode is repaired with external carbon fiber–reinforced polymer (CFRP) wrapping. The efficiency of the proposed retrofitting technique is evaluated by the hysteresis behavior, failure mechanism, and performance index parameters of the re-established frame, which are compared with the results of the initially tested bare frame. The recommended mechanism restricts the restored frame section against any possible movement or rotation and helps by a subsequent shift in yield location. The prime advantage of the proposed technique is that it prevents the possible slip of rebar from the sleeve, which is intercepted by the interlinking process, and eliminates the formation of inclined shear cracks at beam–column joints restricted by externally wrapped CFRP composites. The synergic effect of coupler-box and CFRP enhances the overall performance of the re-established frame by keeping the frame sections intact even after a lateral drift of 6%, which is relatively higher than the collapse prevention drift level, i.e., 4% as per FEMA guidelines. The obtained test results reveal the capability of CFRP and coupler-box assemblage as a possible futuristic approach for retrofitting outmoded RC building frames, in which buckling in longitudinal rebars of columns at their respective plastic hinge locations is inevitable.
- 25 May 2022
- Published by Elsevier in Materials Today: Proceedings
- Vol. 64, 1061-1068
Influence of FRP on the shear behaviour of RC rectangular beam elements
- 25 May 2022
- Published by Elsevier in Materials Today: Proceedings
- Vol. 64, 1061-1068
Influence of FRP on the shear behaviour of RC rectangular beam elements