Pankaj Agarwal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Pankaj Agarwal has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Naveen Kumar Kothapalli
Department of Earthquake Engineering, Indian Institute of Technology Roorkee, Roorkee, India
2 shared publications - Nidhin S. Pachappoyil
IIT Roorkee
2 shared publications - Rajendran Siva Chidambaram
Associate Professor and Principal Scientist, Academy of Scientific and Innovative Research, Ghaziabad 201002, India; Advanced Concrete, Steel and Composites, Council of Scientific and Industrial Research-Central Building Research Institute, Roorkee 247667, India. ORCID:
2 shared publications - A. Miya
IIT Roorkee
1 shared publication - H. Gupta
CSIR—Central Building Research Institute
1 shared publication - Mahua Mukherjee
Department of Architecture and Planning, Indian Institute of Technology Roorkee, Roorkee, India
1 shared publication
Latest Publications
- 13 September 2026
- Published by Wiley in Structural Concrete
Strain‐centric approach for design of confined core concrete in the columns of short and regular RC frames under cyclic tests
The cyclic testing of two full scale regular and short column irregular frames has been carried out under large deformations. The load‐deformation hysteresis behavior of the frames has been obtained along‐with strain‐deformation profile of the core concrete at the plasticized sections of the columns of the frames. The strain values of the core concrete are one of the direct criteria to the damage levels for plastic hinges of structural member as compared to stress or rotation. A strain based damage relationship is quantitatively defined on the basis of developed strain profile and plastic strain resisting capacity of confined core concrete. The developed strain profiles have been monitored and measured by the use of digital image correlation (DIC) technique. The plastic strain resisting capacity of confined core concrete has been determined separately under axial compression of cylindrical and square prismatic specimens with varying amount of volumetric ratio of transverse reinforcement. The strain based severity parameters, that is, strain hysteresis loop (principal strain versus displacement), permanent strain, strain resistance capacity and finally, character of strain angles have been compared to define the damages in the plastic hinged region of the frames.
- 13 September 2026
- Published by Wiley in Structural Concrete
Strain‐centric approach for design of confined core concrete in the columns of short and regular RC frames under cyclic tests
The cyclic testing of two full scale regular and short column irregular frames has been carried out under large deformations. The load‐deformation hysteresis behavior of the frames has been obtained along‐with strain‐deformation profile of the core concrete at the plasticized sections of the columns of the frames. The strain values of the core concrete are one of the direct criteria to the damage levels for plastic hinges of structural member as compared to stress or rotation. A strain based damage relationship is quantitatively defined on the basis of developed strain profile and plastic strain resisting capacity of confined core concrete. The developed strain profiles have been monitored and measured by the use of digital image correlation (DIC) technique. The plastic strain resisting capacity of confined core concrete has been determined separately under axial compression of cylindrical and square prismatic specimens with varying amount of volumetric ratio of transverse reinforcement. The strain based severity parameters, that is, strain hysteresis loop (principal strain versus displacement), permanent strain, strain resistance capacity and finally, character of strain angles have been compared to define the damages in the plastic hinged region of the frames.
- 1 April 2024
- Published by Springer Nature
- p. 121-140
Seismic Strengthening and Retrofitting of RC Structures Using Fibre Reinforced Composites
- 1 April 2024
- Published by Springer Nature
- p. 121-140
Seismic Strengthening and Retrofitting of RC Structures Using Fibre Reinforced Composites
- 28 July 2023
- Published by Springer Nature
- p. 761-776
Comparative Study on Seismic Performance of RC Frame with Different Types of Steel Bracing System
- 28 July 2023
- Published by Springer Nature
- p. 761-776
Comparative Study on Seismic Performance of RC Frame with Different Types of Steel Bracing System
- 28 July 2023
- Published by Springer Nature
- p. 569-586
A State-of-the-Art Review on Metallic Dampers Based on Different Yielding Mechanism
- 28 July 2023
- Published by Springer Nature
- p. 569-586
A State-of-the-Art Review on Metallic Dampers Based on Different Yielding Mechanism
- 20 July 2023
- Published by Springer Nature
- p. 685-694
Structural Performance of Retrofitting Strategies for Dry-Stone Masonry Arch Structures
- 20 July 2023
- Published by Springer Nature
- p. 685-694
Structural Performance of Retrofitting Strategies for Dry-Stone Masonry Arch Structures
- 1 February 2023
- Published by Wiley in Earthquake Spectra
- Vol. 39 (1) , 77-99
Out‐of‐plane performance evaluation of energy‐dissipating hysteretic infill wall system under cyclic loading
An innovative energy‐dissipating hysteretic (EDH) infill system is conceptualized and designed with the help of slotted concrete blocks interlinked with energy‐dissipating link elements. Full‐scale reinforced concrete frames infilled with the EDH infill system and the conventional brick infill system are tested initially under in‐plane cyclic test followed by out‐of‐plane cyclic test. A specially designed double‐leaf airbag test setup maneuvered with hydraulic actuators is fabricated for out‐of‐plane testing of the infilled frames. The hysteresis performance of both the infill wall systems is compared experimentally. A cyclic pushover test in the out‐of‐plane direction is also carried out to assess the amount of damage and the residual capacity of the EDH infill system. The test results reveal that the out‐of‐plane performance with prior in‐plane damage of the EDH infill is significantly improved over the conventional brick infill system in terms of lateral strength, stiffness degradation, deformation capacity, energy dissipation, and effective damping. A numerical model of the EDH infill system is developed based on the elastomeric properties of the energy‐dissipating links in the OpenSees software platform.
- 1 February 2023
- Published by Wiley in Earthquake Spectra
- Vol. 39 (1) , 77-99
Out‐of‐plane performance evaluation of energy‐dissipating hysteretic infill wall system under cyclic loading
An innovative energy‐dissipating hysteretic (EDH) infill system is conceptualized and designed with the help of slotted concrete blocks interlinked with energy‐dissipating link elements. Full‐scale reinforced concrete frames infilled with the EDH infill system and the conventional brick infill system are tested initially under in‐plane cyclic test followed by out‐of‐plane cyclic test. A specially designed double‐leaf airbag test setup maneuvered with hydraulic actuators is fabricated for out‐of‐plane testing of the infilled frames. The hysteresis performance of both the infill wall systems is compared experimentally. A cyclic pushover test in the out‐of‐plane direction is also carried out to assess the amount of damage and the residual capacity of the EDH infill system. The test results reveal that the out‐of‐plane performance with prior in‐plane damage of the EDH infill is significantly improved over the conventional brick infill system in terms of lateral strength, stiffness degradation, deformation capacity, energy dissipation, and effective damping. A numerical model of the EDH infill system is developed based on the elastomeric properties of the energy‐dissipating links in the OpenSees software platform.
- 4 November 2022
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 27 (12) , 3564-3587
Experimental Evaluation of Steel Bracings and Metallic Yield Damper as Retrofit Techniques for Severely Damaged RC Building Frames
The concentrically placed hollow circular steel bracings and hybrid metallic yield dampers as structural retrofitting techniques for severely damaged reinforced concrete (RC) portal frames are evaluated under reverse-cyclic load conditions. In addition, the efficiency of a specially designed coupler-box assembly to retrofit severely damaged columns of the model frame by reconnecting the buckled or ruptured longitudinal reinforcing bars at the plastic hinge locations is evaluated under similar load conditions. Competency of the proposed techniques is assessed by comparing the hysteresis behavior, performance index parameters, and failure mechanism of the retrofitted frames with the native-tested conventional bare frame. The lateral load and deformation capacities are significantly enhanced in the retrofitted frames with a comprehensive increase of 2.0 times in the braced frame and 2.5 times in the damper-equipped frame compared to the conventional bare frame. A stable and symmetric post-yield behavior is noticed in the retrofitted frames until a lateral drift of 3.5% and 6% in braced and damper-fit frames, respectively, which is even higher than the collapse prevention drift level specified in FEMA codal guidelines.
- 4 November 2022
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 27 (12) , 3564-3587
Experimental Evaluation of Steel Bracings and Metallic Yield Damper as Retrofit Techniques for Severely Damaged RC Building Frames
The concentrically placed hollow circular steel bracings and hybrid metallic yield dampers as structural retrofitting techniques for severely damaged reinforced concrete (RC) portal frames are evaluated under reverse-cyclic load conditions. In addition, the efficiency of a specially designed coupler-box assembly to retrofit severely damaged columns of the model frame by reconnecting the buckled or ruptured longitudinal reinforcing bars at the plastic hinge locations is evaluated under similar load conditions. Competency of the proposed techniques is assessed by comparing the hysteresis behavior, performance index parameters, and failure mechanism of the retrofitted frames with the native-tested conventional bare frame. The lateral load and deformation capacities are significantly enhanced in the retrofitted frames with a comprehensive increase of 2.0 times in the braced frame and 2.5 times in the damper-equipped frame compared to the conventional bare frame. A stable and symmetric post-yield behavior is noticed in the retrofitted frames until a lateral drift of 3.5% and 6% in braced and damper-fit frames, respectively, which is even higher than the collapse prevention drift level specified in FEMA codal guidelines.
- 1 June 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 26 (3) , 04022016
Cyclic Evaluation of Severely Damaged RC Frames Repaired and Strengthened through FRP-Wrapped Coupler-Box Confinement
The present study is focused on the retrofitting solution and its verification through experimental investigation for the two most common catastrophic modes of failure in reinforced concrete (RC) frame buildings, namely, buckling of reinforcing bars in the plastic hinge region of columns and shear failure of beam–column joints. The first mode of failure is retrofitted with interlinked coupler-box assemblies, while the second mode is repaired with external carbon fiber–reinforced polymer (CFRP) wrapping. The efficiency of the proposed retrofitting technique is evaluated by the hysteresis behavior, failure mechanism, and performance index parameters of the re-established frame, which are compared with the results of the initially tested bare frame. The recommended mechanism restricts the restored frame section against any possible movement or rotation and helps by a subsequent shift in yield location. The prime advantage of the proposed technique is that it prevents the possible slip of rebar from the sleeve, which is intercepted by the interlinking process, and eliminates the formation of inclined shear cracks at beam–column joints restricted by externally wrapped CFRP composites. The synergic effect of coupler-box and CFRP enhances the overall performance of the re-established frame by keeping the frame sections intact even after a lateral drift of 6%, which is relatively higher than the collapse prevention drift level, i.e., 4% as per FEMA guidelines. The obtained test results reveal the capability of CFRP and coupler-box assemblage as a possible futuristic approach for retrofitting outmoded RC building frames, in which buckling in longitudinal rebars of columns at their respective plastic hinge locations is inevitable.
- 1 June 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 26 (3) , 04022016
Cyclic Evaluation of Severely Damaged RC Frames Repaired and Strengthened through FRP-Wrapped Coupler-Box Confinement
The present study is focused on the retrofitting solution and its verification through experimental investigation for the two most common catastrophic modes of failure in reinforced concrete (RC) frame buildings, namely, buckling of reinforcing bars in the plastic hinge region of columns and shear failure of beam–column joints. The first mode of failure is retrofitted with interlinked coupler-box assemblies, while the second mode is repaired with external carbon fiber–reinforced polymer (CFRP) wrapping. The efficiency of the proposed retrofitting technique is evaluated by the hysteresis behavior, failure mechanism, and performance index parameters of the re-established frame, which are compared with the results of the initially tested bare frame. The recommended mechanism restricts the restored frame section against any possible movement or rotation and helps by a subsequent shift in yield location. The prime advantage of the proposed technique is that it prevents the possible slip of rebar from the sleeve, which is intercepted by the interlinking process, and eliminates the formation of inclined shear cracks at beam–column joints restricted by externally wrapped CFRP composites. The synergic effect of coupler-box and CFRP enhances the overall performance of the re-established frame by keeping the frame sections intact even after a lateral drift of 6%, which is relatively higher than the collapse prevention drift level, i.e., 4% as per FEMA guidelines. The obtained test results reveal the capability of CFRP and coupler-box assemblage as a possible futuristic approach for retrofitting outmoded RC building frames, in which buckling in longitudinal rebars of columns at their respective plastic hinge locations is inevitable.
- 1 February 2022
- Published by Wiley in Earthquake Spectra
- Vol. 38 (1) , 677-701
Cyclic evaluation of energy‐dissipating hysteretic infilled reinforced concrete frame: A novel approach as low‐cost passive energy–dissipating device
A novel energy‐dissipating hysteretic infilled wall system comprising slotted concrete blocks with energy‐dissipating links is designed and experimentally tested in a full‐scale reinforced concrete frame. Its performance is compared with the conventional (brick) infilled frame as well as bare frame. This infill wall system helps to reduce the stiffening effect and also acts as a secondary load‐resisting system that resists lateral loads even after the formation of plastic hinges in the frame. The post‐yield response of the frame becomes stable and no collapse condition arises even at a large deformation. This is a kind of low‐cost passive energy–dissipating method that may act as an efficient and versatile solution to minimize the damages in frame buildings. A systematic numerical model is developed on the basis of a series of experiments conducted on its constituent units that captures the elastic and post‐yield load deformation behavior of the energy‐dissipating hysteretic infilled frame under cyclic loading.
- 1 February 2022
- Published by Wiley in Earthquake Spectra
- Vol. 38 (1) , 677-701
Cyclic evaluation of energy‐dissipating hysteretic infilled reinforced concrete frame: A novel approach as low‐cost passive energy–dissipating device
A novel energy‐dissipating hysteretic infilled wall system comprising slotted concrete blocks with energy‐dissipating links is designed and experimentally tested in a full‐scale reinforced concrete frame. Its performance is compared with the conventional (brick) infilled frame as well as bare frame. This infill wall system helps to reduce the stiffening effect and also acts as a secondary load‐resisting system that resists lateral loads even after the formation of plastic hinges in the frame. The post‐yield response of the frame becomes stable and no collapse condition arises even at a large deformation. This is a kind of low‐cost passive energy–dissipating method that may act as an efficient and versatile solution to minimize the damages in frame buildings. A systematic numerical model is developed on the basis of a series of experiments conducted on its constituent units that captures the elastic and post‐yield load deformation behavior of the energy‐dissipating hysteretic infilled frame under cyclic loading.