Sumit Pramanick
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Sumit Pramanick has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
K. Gopakumar
Department of Electronic Systems Engineering (Formerly Centre for Electronics Design and Technology), Indian Institute of Science, Bangalore, India
7 shared publications- Kumarukuttan Gopakumar
Department of Electronic Systems Engineering, Indian Institute of Science, Bengaluru, India
7 shared publications - Mathews Boby
Department of Electronic Systems Engineering, Indian Institute of Science, Bangalore, India
7 shared publications - Debiprasad Nayak
Department of Electrical Engineering, Indian Institute of Technology Delhi, New Delhi, India
6 shared publications - Leopoldo Garcia Franquelo
University of Seville
5 shared publications - R. Sudharshan Kaarthik
Department of Avionics, Indian Institute of Space Science and Technology, Thiruvananthapuram, India
5 shared publications
Latest Publications
- 23 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (9) , 14312-14322
Control of Low-Frequency Switch-Node Current Using PCB-Embedded Rogowski Coils With Reduced Sampling in GaN-Based PFC Converter
Multiple currents are sensed within a power converter, requiring sensors with different bandwidths. Low-bandwidth sensors are typically used for average current control, while high-bandwidth sensors are employed for device current sensing and protection. Faster schemes of fault protection are required for GaN HEMTs. An effective solution for measuring high slew-rate switching transients in GaN HEMTs is the PCB coil-based current sensor, which offers high bandwidth and easy integrability. However, this sensor cannot be directly used to measure switch-node currents, which may be DC or line-frequency AC. This article proposes an online, analog-based reconstruction scheme for measurement of the switch-node grid current, with device current information from PCB-embedded Rogowski Coil (PCB-RC) sensors. The analog realisation facilitates current reconstruction with low latency and reduced sampling requirement. The reconstructed grid current is used for control of a GaN-based 3.3 kW Bidirectional Totem-pole PFC converter. Additionally, an overcurrent protection scheme is implemented using the reconstructed grid current, triggering safe shutdown of the converter during overload. Further, with the developed PCB-RCs, short-circuit protection of GaN HEMTs is achieved for a DC bus fault at 400 V. Therefore, PCB-RCs are demonstrated as a viable alternative to CTs and Hall-effect sensors, serving dual purposes of current control and protection.
- 23 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (9) , 14312-14322
Control of Low-Frequency Switch-Node Current Using PCB-Embedded Rogowski Coils With Reduced Sampling in GaN-Based PFC Converter
Multiple currents are sensed within a power converter, requiring sensors with different bandwidths. Low-bandwidth sensors are typically used for average current control, while high-bandwidth sensors are employed for device current sensing and protection. Faster schemes of fault protection are required for GaN HEMTs. An effective solution for measuring high slew-rate switching transients in GaN HEMTs is the PCB coil-based current sensor, which offers high bandwidth and easy integrability. However, this sensor cannot be directly used to measure switch-node currents, which may be DC or line-frequency AC. This article proposes an online, analog-based reconstruction scheme for measurement of the switch-node grid current, with device current information from PCB-embedded Rogowski Coil (PCB-RC) sensors. The analog realisation facilitates current reconstruction with low latency and reduced sampling requirement. The reconstructed grid current is used for control of a GaN-based 3.3 kW Bidirectional Totem-pole PFC converter. Additionally, an overcurrent protection scheme is implemented using the reconstructed grid current, triggering safe shutdown of the converter during overload. Further, with the developed PCB-RCs, short-circuit protection of GaN HEMTs is achieved for a DC bus fault at 400 V. Therefore, PCB-RCs are demonstrated as a viable alternative to CTs and Hall-effect sensors, serving dual purposes of current control and protection.
- 23 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (8) , 13941-13955
Grid Integrated Single-Stage Current-Fed Three-Port Converter for High and Low Voltage Battery Charging in Electric Vehicles
This article proposes a new three-port integrated onboard charger (IOBC) topology for electric vehicles (EVs), enabling simultaneous charging to both high-voltage (HV) and low-voltage (LV) batteries. The proposed topology combines a single-phase single-stage current-fed onboard charger (OBC) with a low-voltage auxiliary power module (LVAPM) through a three-winding high-frequency transformer (3W-HFT), eliminating the conventional dedicated power factor correction (PFC) stage. For simultaneous power transfer within this integrated topology, the dependency of the LV-side duty cycle variation on the sinusoidal modulation of the grid and HV side converters is established. Based on this analysis, an adaptive sinusoidal pulse width modulation (ASPWM) strategy is proposed to dynamically accommodate these duty variations, thereby ensuring simultaneous power distribution to the loads. In addition, steady-state analysis and various operational modes of the proposed topology across switching intervals over the grid cycle are also discussed thoroughly. A 2.2 kW experimental prototype is developed to validate the proposed integrated three-port converter operation under varying load conditions. Experimental results demonstrate a power factor above 0.99 over the entire operating range and a peak efficiency of 95.04$\%$ during simultaneous power transfer (SPT) to both batteries.
- 23 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (8) , 13941-13955
Grid Integrated Single-Stage Current-Fed Three-Port Converter for High and Low Voltage Battery Charging in Electric Vehicles
This article proposes a new three-port integrated onboard charger (IOBC) topology for electric vehicles (EVs), enabling simultaneous charging to both high-voltage (HV) and low-voltage (LV) batteries. The proposed topology combines a single-phase single-stage current-fed onboard charger (OBC) with a low-voltage auxiliary power module (LVAPM) through a three-winding high-frequency transformer (3W-HFT), eliminating the conventional dedicated power factor correction (PFC) stage. For simultaneous power transfer within this integrated topology, the dependency of the LV-side duty cycle variation on the sinusoidal modulation of the grid and HV side converters is established. Based on this analysis, an adaptive sinusoidal pulse width modulation (ASPWM) strategy is proposed to dynamically accommodate these duty variations, thereby ensuring simultaneous power distribution to the loads. In addition, steady-state analysis and various operational modes of the proposed topology across switching intervals over the grid cycle are also discussed thoroughly. A 2.2 kW experimental prototype is developed to validate the proposed integrated three-port converter operation under varying load conditions. Experimental results demonstrate a power factor above 0.99 over the entire operating range and a peak efficiency of 95.04$\%$ during simultaneous power transfer (SPT) to both batteries.
- 5 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (3) , 3908-3922
A Unified Bézier Curve-Based Flux-Linkage Model for Position Sensorless Model Predictive Current Control of SRMs
Precise flux-linkage characterization plays a crucial role in current and torque control strategies of switched reluctance motors, which are becoming increasingly common in industrial and automotive applications. Moreover, due to the challenges posed by physical rotor position sensors, there is a constant demand for a cost-effective position estimation method that can be easily implemented on a digital computation platform. This work presents a method for modelling and control of a position sensorless SRM drive, using a technique considering a unified Bézier curve approach that reduces memory requirements typically associated with large lookup tables used in conventional control techniques. The inherent simplicity of this technique facilitates its application in precise position estimation and model predictive current control (MPCC), and ensures that it can be implemented on low-cost digital processors with low computational burden. The presented method is experimentally tested on a 2.2 kW SRM, demonstrating its efficacy in position sensorless current control. The performance of the presented method in tracking current reference is found to be superior to that of conventionally used current controllers without imposing high memory requirements or computational burden.
- 5 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (3) , 3908-3922
A Unified Bézier Curve-Based Flux-Linkage Model for Position Sensorless Model Predictive Current Control of SRMs
Precise flux-linkage characterization plays a crucial role in current and torque control strategies of switched reluctance motors, which are becoming increasingly common in industrial and automotive applications. Moreover, due to the challenges posed by physical rotor position sensors, there is a constant demand for a cost-effective position estimation method that can be easily implemented on a digital computation platform. This work presents a method for modelling and control of a position sensorless SRM drive, using a technique considering a unified Bézier curve approach that reduces memory requirements typically associated with large lookup tables used in conventional control techniques. The inherent simplicity of this technique facilitates its application in precise position estimation and model predictive current control (MPCC), and ensures that it can be implemented on low-cost digital processors with low computational burden. The presented method is experimentally tested on a 2.2 kW SRM, demonstrating its efficacy in position sensorless current control. The performance of the presented method in tracking current reference is found to be superior to that of conventionally used current controllers without imposing high memory requirements or computational burden.
- 24 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (2) , 2390-2401
Discontinuous Modulation-Based Active Thermal Control for Enhancing the KVA Limit of Grid-Connected Inverter-Based Resources
The kVA limit of a power electronic converter (PEC) is often limited to keep the junction temperature ($T_{j}$) within a safe operating area (SOA). Hence, controlling $T_{j}$ with advanced algorithms such as active thermal control (ATC) methods seems to be a promising way to increase the kVA limit of PEC. In this regard, this article presents a novel closed-loop control approach, combining the discontinuous pulse width modulation (DPWM) strategy with a system-level current controller. The proposed method enables grid-connected inverter-based resources (IBR) to increase their kVA limit without violating the $T_{j}$ limit. This method further allows the converters to operate at a higher ambient temperature ($T_{\rm amb}$) without sacrificing their power handling capacity. An analytical relationship between the bus clamp angle ($\alpha$) with respect to the switching loss ($P_{\rm sw}$) for DPWM has been explained, which is then used as a control variable for the ATC. For the thermal model, a simple Foster thermal model-based temperature estimation method is described, and its accuracy has been depicted.
- 24 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (2) , 2390-2401
Discontinuous Modulation-Based Active Thermal Control for Enhancing the KVA Limit of Grid-Connected Inverter-Based Resources
The kVA limit of a power electronic converter (PEC) is often limited to keep the junction temperature ($T_{j}$) within a safe operating area (SOA). Hence, controlling $T_{j}$ with advanced algorithms such as active thermal control (ATC) methods seems to be a promising way to increase the kVA limit of PEC. In this regard, this article presents a novel closed-loop control approach, combining the discontinuous pulse width modulation (DPWM) strategy with a system-level current controller. The proposed method enables grid-connected inverter-based resources (IBR) to increase their kVA limit without violating the $T_{j}$ limit. This method further allows the converters to operate at a higher ambient temperature ($T_{\rm amb}$) without sacrificing their power handling capacity. An analytical relationship between the bus clamp angle ($\alpha$) with respect to the switching loss ($P_{\rm sw}$) for DPWM has been explained, which is then used as a control variable for the ATC. For the thermal model, a simple Foster thermal model-based temperature estimation method is described, and its accuracy has been depicted.
- 9 August 2025
- Published by Springer Nature in Sādhanā
- Vol. 50 (3) , 1-20
Overview and comparative analysis of single phase bidirectional isolated AC–DC converters for on-board electric vehicle battery charger
- 9 August 2025
- Published by Springer Nature in Sādhanā
- Vol. 50 (3) , 1-20
Overview and comparative analysis of single phase bidirectional isolated AC–DC converters for on-board electric vehicle battery charger
- 8 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (2) , 5927-5937
Analytical Evaluation of Loss Reduction With ZPA Over Full ZVS Operation for Bidirectional WPT System
The enhancement of efficiency in bidirectional wireless power transfer (BWPT) systems depends on minimizing losses occurring in the coils and high-frequency (HF) converters. Circuit impedance optimization through zero-phase-angle (ZPA) operation is essential to address coil losses. However, turn-on switching losses of ground and vehicle assembly (VA) converters are reduced by operating under full zero voltage switching (FZVS). However, the existing literature lacks thorough research that quantifies and compares the loss reduction with the ZPA or FZVS across various operating conditions to maximize the efficiency of BWPT systems. This article comprehensively analyzes the BWPT system losses, incorporating ZPA and FZVS operating conditions. It provides mathematical conditions for achieving FZVS operation across a broad range of misalignments and varying load conditions. The article also evaluates losses and efficiency in varied loading and misalignment scenarios for ZPA and FZVS, deriving optimal operating conditions to maximize system efficiency. The comparative analysis is performed on a 1-kW series-series (S-S) compensated BWPT system, and the findings are supported by experimental and simulated results.
- 8 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (2) , 5927-5937
Analytical Evaluation of Loss Reduction With ZPA Over Full ZVS Operation for Bidirectional WPT System
The enhancement of efficiency in bidirectional wireless power transfer (BWPT) systems depends on minimizing losses occurring in the coils and high-frequency (HF) converters. Circuit impedance optimization through zero-phase-angle (ZPA) operation is essential to address coil losses. However, turn-on switching losses of ground and vehicle assembly (VA) converters are reduced by operating under full zero voltage switching (FZVS). However, the existing literature lacks thorough research that quantifies and compares the loss reduction with the ZPA or FZVS across various operating conditions to maximize the efficiency of BWPT systems. This article comprehensively analyzes the BWPT system losses, incorporating ZPA and FZVS operating conditions. It provides mathematical conditions for achieving FZVS operation across a broad range of misalignments and varying load conditions. The article also evaluates losses and efficiency in varied loading and misalignment scenarios for ZPA and FZVS, deriving optimal operating conditions to maximize system efficiency. The comparative analysis is performed on a 1-kW series-series (S-S) compensated BWPT system, and the findings are supported by experimental and simulated results.
- 2 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (1) , 549-559
Analytical Modeling of Fault Transient in a GaN HEMT Half Bridge and Its Overcurrent Protection With PCB Embedded Rogowski Coils
The low Short Circuit Withstand Time (SCWT) offered by GaN HEMTs imposes challenges on their reliability, especially in medium to high power applications such as electric vehicle chargers. This article models the short circuit fault transient in a GaN HEMT half-bridge configuration including parasitic elements, based on the state-variables in the circuit and the datasheet parameters. Faults at higher bus voltages result in increased instantaneous power loss, which in turn lead to higher junction temperatures. This results in reduced SCWT for the device. The model is further used to estimate the fault clearing time for different dc bus voltages. A scheme for ultrafast overcurrent protection of GaN HEMTs is presented. The protection scheme employs a non-intrusive PCB-embedded Rogowski Coil (PCB-RC) based current sensing technique for sensing the device current. Experimental results with the dc bus voltage set to 400 V, demonstrating the protection of the device subjected to a hard switched fault (HSF) are presented. The protection response time is reported to be 38 ns, which is less than the estimated fault clearing time.
- 2 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (1) , 549-559
Analytical Modeling of Fault Transient in a GaN HEMT Half Bridge and Its Overcurrent Protection With PCB Embedded Rogowski Coils
The low Short Circuit Withstand Time (SCWT) offered by GaN HEMTs imposes challenges on their reliability, especially in medium to high power applications such as electric vehicle chargers. This article models the short circuit fault transient in a GaN HEMT half-bridge configuration including parasitic elements, based on the state-variables in the circuit and the datasheet parameters. Faults at higher bus voltages result in increased instantaneous power loss, which in turn lead to higher junction temperatures. This results in reduced SCWT for the device. The model is further used to estimate the fault clearing time for different dc bus voltages. A scheme for ultrafast overcurrent protection of GaN HEMTs is presented. The protection scheme employs a non-intrusive PCB-embedded Rogowski Coil (PCB-RC) based current sensing technique for sensing the device current. Experimental results with the dc bus voltage set to 400 V, demonstrating the protection of the device subjected to a hard switched fault (HSF) are presented. The protection response time is reported to be 38 ns, which is less than the estimated fault clearing time.
- 27 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (2) , 1274-1287
Dodecagonal Voltage Space Vector-Based Hybrid PWM Technique for the Reduction of Torque Ripple in OEWIM Drive
The dodecagonal voltage space vector PWM (DSVPWM) applied to the open-ended winding induction motor (OEWIM) using the switched capacitor filter (SCF) topology has the benefit of effectively suppressing phase voltage harmonics of the order of $6n\pm 1$ ( $n$ is an odd number) in the entire modulation range. The DSVPWM exhibits superior harmonic performance compared to the CSVPWM in the complete speed range. However, the torque ripple performance is in the linear modulation range, almost comparable to the CSVPWM, and it exhibits superior performance at higher speeds. This research article focuses on the further improvement of the torque ripple on the OEWIM, compared to the DSVPWM, by employing a hybrid PWM switching sequence. This hybrid PWM sequence is a combined sequence of the DSVPWM sequence and advanced bus clamping sequences. Analytical, simulation, and experimental studies demonstrate that the hybrid PWM exhibits equivalent RMS torque ripple performance to DSVPWM at low and medium speed ranges. However, it significantly improves at a higher speed range, with a marginal improvement in the current THD at higher speed ranges. A 2.2 KW OEWIM is employed in the experiment to verify the effectiveness of the suggested hybrid PWM approach.
- 27 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (2) , 1274-1287
Dodecagonal Voltage Space Vector-Based Hybrid PWM Technique for the Reduction of Torque Ripple in OEWIM Drive
The dodecagonal voltage space vector PWM (DSVPWM) applied to the open-ended winding induction motor (OEWIM) using the switched capacitor filter (SCF) topology has the benefit of effectively suppressing phase voltage harmonics of the order of $6n\pm 1$ ( $n$ is an odd number) in the entire modulation range. The DSVPWM exhibits superior harmonic performance compared to the CSVPWM in the complete speed range. However, the torque ripple performance is in the linear modulation range, almost comparable to the CSVPWM, and it exhibits superior performance at higher speeds. This research article focuses on the further improvement of the torque ripple on the OEWIM, compared to the DSVPWM, by employing a hybrid PWM switching sequence. This hybrid PWM sequence is a combined sequence of the DSVPWM sequence and advanced bus clamping sequences. Analytical, simulation, and experimental studies demonstrate that the hybrid PWM exhibits equivalent RMS torque ripple performance to DSVPWM at low and medium speed ranges. However, it significantly improves at a higher speed range, with a marginal improvement in the current THD at higher speed ranges. A 2.2 KW OEWIM is employed in the experiment to verify the effectiveness of the suggested hybrid PWM approach.
- 8 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (4) , 5813-5824
Input Reactive Power Control of Bidirectional WPT to Improve System Efficiency
Misalignment can significantly affect the mutual inductance of a wireless power transfer (WPT) system, thereby impacting the system's power transfer capabilities and efficiency. Traditionally, to achieve optimal efficiency with constant output power under misalignment, individual closed-loop feedback control needs to be used on both the transmitter and receiver sides. The receiver side phase shift ( $\beta$ ) is controlled to maintain the constant output power, and the transmitter side phase shift ( $\alpha$ ) is controlled to achieve zero power factor angle (ZPA) for optimal efficiency. The ZPA condition is achieved by making the input reactive power ( $Q_{in}$ ) equal to zero. However, this necessitates additional high- bandwidth sensing circuitry, thereby increasing system complexity. Moreover, it also introduces the cross-coupling issue due to formation of multi input multi output (MIMO) system. This paper proposes a simple, decoupled, and fast response control approach for mitigating the impact of misalignment and load variation by employing a single receiver-side PI controller. A closed form analytical relationship between $\alpha$ and $\beta$ has been established in this paper to maintain optimal efficiency while regulating output power under misalignment conditions. The proposed method obtains $\beta$ from the receiver side controller and $\alpha$ from the derived relation. The proposed control method is validated using an experimental setup of a 1 kW bidirectional wireless power transfer (BWPT) system. The simulation and experimental results of the BWPT system under various loading and misalignment conditions are presented.
- 8 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (4) , 5813-5824
Input Reactive Power Control of Bidirectional WPT to Improve System Efficiency
Misalignment can significantly affect the mutual inductance of a wireless power transfer (WPT) system, thereby impacting the system's power transfer capabilities and efficiency. Traditionally, to achieve optimal efficiency with constant output power under misalignment, individual closed-loop feedback control needs to be used on both the transmitter and receiver sides. The receiver side phase shift ( $\beta$ ) is controlled to maintain the constant output power, and the transmitter side phase shift ( $\alpha$ ) is controlled to achieve zero power factor angle (ZPA) for optimal efficiency. The ZPA condition is achieved by making the input reactive power ( $Q_{in}$ ) equal to zero. However, this necessitates additional high- bandwidth sensing circuitry, thereby increasing system complexity. Moreover, it also introduces the cross-coupling issue due to formation of multi input multi output (MIMO) system. This paper proposes a simple, decoupled, and fast response control approach for mitigating the impact of misalignment and load variation by employing a single receiver-side PI controller. A closed form analytical relationship between $\alpha$ and $\beta$ has been established in this paper to maintain optimal efficiency while regulating output power under misalignment conditions. The proposed method obtains $\beta$ from the receiver side controller and $\alpha$ from the derived relation. The proposed control method is validated using an experimental setup of a 1 kW bidirectional wireless power transfer (BWPT) system. The simulation and experimental results of the BWPT system under various loading and misalignment conditions are presented.