    Thermal and imaging effects of Feraheme in MR-guided focused ultrasound: a phantom study

    by Myung-Ho In, Zaiyang Long, Janusz H Hankiewicz, Alexey V Nazarov, Stephen E Russek, Chunming Gu, Krzysztof R Gorny, Nicholas J Hangiandreou, Jaydev K Dave, Christin A Tiegs-Heiden, et al.

    Objective The use of Feraheme (ferumoxytol) as a contrast agent in MR-guided focused ultrasound (MRgFUS) tumor ablations could enhance treatment safety and efficacy by improving vascular visualization through strong T1 and T2 shortening effects. However, Feraheme impact on MR thermometry and tissue heating is unclear. This study evaluates the feasibility of incorporating Feraheme into MRgFUS by assessing its impact on MR imaging contrast, MR thermometry, and thermal response in tissue-mimicking phantoms. Approach Tissue-mimicking phantoms with 0 (baseline), 0.25, and 0.5 mM Feraheme concentrations were prepared using a validated recipe. Acoustic attenuation was measured with a commercial diagnostic ultrasound scanner. MR imaging at 1.5 T was performed to assess gradient-recalled-echo (GRE)-based thermometry signal-to-noise-ratio (SNR), relaxation rates, and relaxivities. MRgFUS system integrated with 1.5 T MRI was used to perform multiple sonications in the phantoms. Temperature elevations and focal heating areas were quantified from proton resonance frequency (PRF) shift thermometry. Experiments were repeated three times over the period of eight-weeks. Separately, temperature-dependent NMR spectroscopy was performed at 3.0 T in saline-diluted Feraheme phantoms (0, 0.25, 0.5, and 1.0 mM) to assess the influence of Feraheme concentration on PRF coefficients used in MR thermometry. Main results Phantoms showed nuclear relaxation times (T1: 1178.1±77.8, T2: 103.21±2.45 ms) and attenuation coefficients (0.34-0.36 dB/cm/MHz) within expected biological tissue ranges. Relaxivities demonstrated a strong linear dependence on Feraheme concentration (r1: 17.5±0.2, r2: 209.2±2.6 s⁻¹mM⁻¹). Relative to baseline (0 mM) phantom, the SNR of GRE-based thermometry increased by 12.6% at 0.25 mM and decreased by 27.1 % at 0.5 mM. Sonications in Feraheme-containing phantoms resulted in statistically higher temperature elevations (p<0.001) although no statistically significant difference was observed between 0.25 and 0.5 mM. All NMR measurements demonstrated stable, linear PRF temperature dependence (R² = 0.996–0.999), with PRF coefficients (between −0.0074 and −0.0082 ppm/°C). The resulting thermometry bias was small and predictable (+0.67 and +1.73 per 20 °C at 3.0 T for 0.25 and 0.5 mM). Significance These findings demonstrate that MR thermometry remains feasible at moderate Feraheme concentrations and support its potential use to enhance visualization of critical vasculature near targeted tissues during MRgFUS.

  • Open Access

    Building a comprehensive quality infrastructure in a large radiography practice

    by Z. Long, S.J. Dean, A.K. Forney, Z.W. Gartner, J.L. Wiste, B.A. Warndahl, B.D. Stuve, D.J. Larson, T.R. Daly, B.A. Schueler, et al.

  • Open Access

    Deriving target exposure indices for common radiography exams based on automatic exposures of flat‐field phantoms

    by Matthew Hoerner, Emily L. Marshall, Katie Hulme, Ashley Tao, Suha Alshehri, Shady AlKhazzam, Zaiyang Long, Erin Macdonald, Kathleen Scilla, Ioannis Tsalafoutas

    Background: The IEC exposure index (EI), deviation index (DI), and target exposure index (EI T ), represent critical standardized metrics for the evaluation of exposure and quality in radiographic imaging. Purpose: This work develops and validates a systematic procedure to estimate the EI T for eight of the most common radiography imaging protocols utilizing automatic exposure control (AEC) from measurements acquired under reference conditions. Methods: A model was developed to define the relationship between a systems AEC logic, and an estimation of the EI under flat‐field conditions (EIFFC). Separately, clinical data and acquisition protocol information for resultant EI during patient studies were also collected for the eight protocols studied: Chest posteroanterior (PA), Chest lateral, Abdomen anteroposterior (AP), Pelvis AP, L‐Spine AP, C‐Spine AP, T‐Spine AP, and Ribs AP. Data were collected from 41 x‐ray units spanning seven institutions. For each protocol on each unit the EIFFC was computed based on the acquisition protocol, as well as median EI from clinical exams to produce a scaling factor (SF). Kruskal–Wallis statistical tests were used to compare SF's between vendors and AEC cell configurations. Results: SFs for eight radiographic imaging protocols have been produced per vendor and per AEC cell selection. A workflow has been established for end‐users to follow to apply these SFs to flat‐field measurements taken at their own locations to establish local EI T . Conclusions: The study results show that in seven of the eight imaging protocols, the SFs for most units included in the study report SFs within 1 DI (± 25%) of their respective final vendor reported SF (218/228). The ribs protocol is the exception to this finding (n = 26). SFs have high utility for establishing EI T values on individual x‐ray units and normalizing EI value distributions for quality assurance purposes.


  • General Radiographic Artifacts: A Visual Review

    by Zaiyang Long, Lindsay M. Ranschau, Jill M. Lucas, Stephen M. Broski, Beth A. Schueler

    This slide presentation uses real-world examples from diverse modern systems to categorize digital radiographic artifacts by likely cause and outlines investigation and mitigation strategies to improve troubleshooting, artifact prevention, and patient care.


  • Multi‐Institutional Survey of 4‐Year Ultrasound Quality Control Findings

    by Zaiyang Long, Megan Russ, Sandra Larson, Mark R. Holland, Zheng‐Feng Lu, Cameron Kofler, Wei Zhou, Jian‐Feng Chen, Zhimin Li, James Zagzebski, et al.

    Objectives: Periodic quality control (QC) testing of ultrasound (US) imaging systems is essential to ensure and maintain image quality and safety. The study aims to analyze QC findings from medical physics annual surveys of modern clinical US systems in a multi‐institutional survey. Methods: QC results from annual surveys between 2018 and 2021 were retrospectively collected from 12 medical physicists from 11 institutions or consulting companies (hereafter referred to as sites). QC tests were classified as scanner‐ and transducer‐related tests, where scanner‐related tests also included evaluation of diagnostic workstation display monitors and routine QC programs if applicable. Test methodology and pass/fail criteria were established by each site. QC findings were defined as results requiring follow‐up action by service engineers, vendors, or other personnel. The percentage of annual findings was calculated for each site and averaged across the years of data contributed. Furthermore, findings across all sites were aggregated for an overall analysis. Results: QC data from a total of 1069 scanner tests and 4542 transducer tests were collected. The average annual percentage of scanner‐related findings varied from 0 to 40.8% among all sites (first quartile 8.7%, median 18.2%, and third quartile 34.1%), while that of transducer‐related findings ranged between 0.5% and 19.9% (first quartile 3.9%, median 7.2%, and third quartile 14.5%). For scanner‐related tests, the top 3 categories of findings were associated with physical and mechanical integrity (171 findings, 74.7%), quantitative testing of the scanner display monitor (40 findings, 17.5%), and scanner port creating artifacts (10 findings, 4.4%). The top 3 findings for transducers related to uniformity and artifact (227 findings, 79.9%), physical and mechanical integrity (44 findings, 15.5%), and sensitivity in fundamental mode (9 findings, 3.2%). Conclusions: Medical physics annual surveys revealed considerable actionable findings of modern US systems, which inform the status of current US QC practices in the United States and may guide future standardization and recommendation of QC tests.


  • Open Access

    MRgFUS ablation of a recurrent tenosynovial giant cell tumor in the foot using ExAblate 2100 system in combination with patient immobilization device

    by Z. Long, G.K. Hesley, A. Lu, N.J. Hangiandreou, K.R. Gorny, C.A. Tiegs-Heiden

  • Open Access

    Workload and use factor data for a modern digital radiography system

    by Krystal M. Kirby, Beth A. Schueler, Laurel A. Littrell, Zaiyang Long

    The well‐referenced structural shielding design NCRP Report No. 147 uses workload information based on self‐reported film‐screen data from the AAPM Task Group 9 survey. The aim of this study was to assess the clinical workload distributions of modern digital radiography (DR) systems in general hospital and pediatric‐only practices. A retrospective analysis of DR imaging data on four radiographic systems in a hospital practice and two radiographic systems in a pediatric practice, through a custom clinical DICOM header analytics program. A total of 203, 294 exposures from the general hospital practice and 25,415 from the pediatric practice from 2019 and 2021 were included. Values for kVp, mAs, and detector type (wall bucky, table bucky, or free detector) were extracted. For each exam, mAs was accumulated in a kVp histogram with bins 5 kVp wide and further parsed by detector type. Total workload was calculated by summing all exposures, then normalized by the number of patients. The median (25th and 75th percentile) workload in the hospital practice was 0.43 (0.22, 1.13) mA‐min per patient, while the average was 1.36 ± 3.08. Pediatric data yielded a median (25th and 75th percentile) of 0.10 (0.05, 0.23) and an average of 0.29 ± 0.69 mA‐min per patient. Mean number of patients per week was 230 adult and 57 pediatric. Hospital workload data is approximately 44% less than the NCRP Report No. 147 value.


  • Technical note: Four‐year experience with utilization of DICOM metadata analytics in clinical digital radiography practice

    by Zaiyang Long, Alisa I. Walz‐Flannigan, Laurel A. Littrell, Beth A. Schueler

    Background Digital radiography (DR) still presents many challenges and could have complex imaging acquisition and processing patterns in a clinical practice hindering quality standardization. PurposeThis technical note aims to report the 4-year experience with utilizing a custom DICOM metadata analytics program in clinical DR at a large institution. MethodsThirty-eight DR systems of three vendors at multiple locations were configured to automatically send clinical DICOM images to a DICOM receiver. A suite of custom MATLAB programs was established to extract and store public and private header data weekly. Specific use cases are provided for systematic image acquisition investigation, image processing harmonization, exposure index (EI) longitudinal monitoring and EI target optimization. Results For systematic acquisition investigation, an example of adult lumbar spine exam analysis was provided with statistics on manual acquisition versus the use of automatic exposure control (AEC, including AEC dose level, active cell, and backup timer), grid usage, and collimation for various projections. For processing harmonization, up to 12.6% of protocols were revealed to have processing parameter differences in an example of a mobile radiography fleet. In addition, inconsistent use of a post-acquisition image size function was also demonstrated, which resulted in anatomy size display variations. Bimonthly monitoring of median EI values showed expected trends, including changes after an AEC dose level adjustment for adult posterior-anterior chest imaging on a scanner system. An example of adult axillary shoulder EI target refinement was shared using the median value, e mu, based on the lognormal EI data distribution after parsing down to acquisitions with appropriate techniques. ConclusionsThis analytics program enables systematic analysis of image acquisition and processing details. The information provides invaluable insights into real practice patterns, which can support data-driven quality standardization and optimization.


  • Open Access

    Impact of flexible noise control (FNC) image processing parameters on portable chest radiography

    by Krystal M. Kirby, Liqiang Ren, Timothy R. Daly, Yasmeen K. Tandon, Brian J. Bartholmai, Beth A. Schueler, Zaiyang Long

    There is a lack of understanding in the performance of flexible noise control (FNC) processing, which is used in digital radiography on a scanner vendor and has four parameters each involving multiple options. The aim of this study was to investigate the impact of FNC on portable chest imaging. An anthropomorphic chest phantom was imaged using a clinical chest program with 85 kV and five radiation dose levels at 40″ source‐to‐image distance with software‐based scatter reduction method. All images were processed without and with FNC. Noise analysis was performed in two regions of interest (ROI) on subtracted noise‐only images, and line profiles were generated through a lung‐rib interface. In addition, noise power spectra (NPS) analysis was performed in solid water phantoms of 10 and 20 cm thicknesses, using the same acquisition program and a range of dose levels. Last, feedback on retrospectively deidentified, reprocessed, and randomized clinical images from 20 portable chest exams was gathered from two thoracic radiologists. Noise reduction performances of FNC were demonstrated, with the level depending on specific FNC parameters, dose levels, ROI placement, and phantom sizes. Higher frequency textural patterns were revealed through the NPS analysis, which varied based on FNC parameters, dose levels, and phantom sizes. Overall, the vendor default parameter FGA0.5 yielded the highest noise reduction and textural artifacts. Radiologist feedback showed consistent preference of no FNC due to the presence of textural artifacts in the FNC‐processed images. An algorithm improvement to avoid introducing artifacts would be desired.