Background Digital radiography (DR) still presents many challenges and could have complex imaging acquisition and processing patterns in a clinical practice hindering quality standardization. PurposeThis technical note aims to report the 4-year experience with utilizing a custom DICOM metadata analytics program in clinical DR at a large institution. MethodsThirty-eight DR systems of three vendors at multiple locations were configured to automatically send clinical DICOM images to a DICOM receiver. A suite of custom MATLAB programs was established to extract and store public and private header data weekly. Specific use cases are provided for systematic image acquisition investigation, image processing harmonization, exposure index (EI) longitudinal monitoring and EI target optimization. Results For systematic acquisition investigation, an example of adult lumbar spine exam analysis was provided with statistics on manual acquisition versus the use of automatic exposure control (AEC, including AEC dose level, active cell, and backup timer), grid usage, and collimation for various projections. For processing harmonization, up to 12.6% of protocols were revealed to have processing parameter differences in an example of a mobile radiography fleet. In addition, inconsistent use of a post-acquisition image size function was also demonstrated, which resulted in anatomy size display variations. Bimonthly monitoring of median EI values showed expected trends, including changes after an AEC dose level adjustment for adult posterior-anterior chest imaging on a scanner system. An example of adult axillary shoulder EI target refinement was shared using the median value, e mu, based on the lognormal EI data distribution after parsing down to acquisitions with appropriate techniques. ConclusionsThis analytics program enables systematic analysis of image acquisition and processing details. The information provides invaluable insights into real practice patterns, which can support data-driven quality standardization and optimization.Keywords
This publication has 16 references indexed in Scilit:
- Automated characterization of perceptual quality of clinical chest radiographs: Validation and calibration to observer preferenceMedical Physics, 2014
- An image‐based technique to assess the perceptual quality of clinical chest radiographsMedical Physics, 2012
- A survey of digital radiography practice in four South African teaching hospitals: an illuminative studyBiomedical Imaging and Intervention Journal, 2010
- One Year’s Results from a Server-Based System for Performing Reject Analysis and Exposure Analysis in Computed RadiographyJournal of Digital Imaging, 2009
- DICOM Metadata repository for technical information in digital medical imagesActa Oncologica, 2009
- DIGITAL RADIOGRAPHY: IMAGE QUALITY AND RADIATION DOSEHealth Physics, 2008
- Image Retake Analysis in Digital Radiography Using DICOM Header InformationJournal of Digital Imaging, 2008
- Digital Radiography Image Quality: Image AcquisitionJournal of the American College of Radiology, 2007
- Digital Radiography Image Quality: Image Processing and DisplayJournal of the American College of Radiology, 2007
- Advances in Digital Radiography: Physical Principles and System OverviewRadioGraphics, 2007