Cheng Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Cheng Yu has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Wenying Zhang
Ph.D. Candidate, Dept. of Structural Engineering, Tongji Univ., Shanghai 200092, China
6 shared publications - Mahsa Mahdavian
Graduate Student, Dept. of Engineering Technology, Univ. of North Texas, Denton, TX 76207
5 shared publications Mahsa Mahdavian
Mahsa Mahdavian, ASC Steel Deck, Sacramento, CA, USA
4 shared publicationsWenying Zhang
Assistant Professor, Beijing Key Laboratory of Earthquake Engineering and Structural Retrofit, Beijing Univ. of Technology, Beijing 100022, China
4 shared publications- Jie Wang
Graduate Research Assistant, Dept. of Civil Engineering, Tsinghua Univ., Beijing 100083, China
2 shared publications - Mohamad Yousof
Graduate Research Assistant, Dept. of Engineering Technology, Univ. of North Texas, Denton, TX 76207
2 shared publications
Latest Publications
- 23 May 2025
- Published by Elsevier in Thin-Walled Structures
- Vol. 215
Axial compressive capacity design method of internally stiffened double steel plate shear walls
- 23 May 2025
- Published by Elsevier in Thin-Walled Structures
- Vol. 215
Axial compressive capacity design method of internally stiffened double steel plate shear walls
- 7 June 2023
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 26 (11) , 1988-2005
Seismic performance cold-Formed steel framed shear walls using in-Frame corrugated steel sheathing
To meet the increasing demand for high strength and non-combustible shear wall systems in mid-rise cold-formed steel (CFS) constructions, this paper investigates the seismic performance and design method of an innovative CFS shear wall system with in-frame corrugated steel sheathing based on previous studies. Shear wall and bearing wall specimens with in-frame corrugated steel sheathing are tested under combined lateral and gravity loading. Simplified numerical models of whole archetype buildings are established. The seismic performance evaluation is performed using methodology recommended in FEMA P695 and the seismic performance factors are examined. The test results show that the shear strength of the innovative shear wall is much higher than currently code certified wood-based shear walls in AISI S400. Also, the shear strength of bearing walls is approximately one-third of the shear strength of shear walls, which proves that bearing walls also contribute significant shear resistance in a structure. The seismic performance evaluation results verified that the existing seismic performance factors (R = Cd = 6.5 and [ ] = 3.0) for CFS shear walls with flat steel sheathings can also be used for the innovative shear wall system. The innovative CFS shear wall system with in-frame corrugated steel sheathing could be employed for mid-rise buildings in areas that are prone to high seismic and wind loads.
- 7 June 2023
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 26 (11) , 1988-2005
Seismic performance cold-Formed steel framed shear walls using in-Frame corrugated steel sheathing
To meet the increasing demand for high strength and non-combustible shear wall systems in mid-rise cold-formed steel (CFS) constructions, this paper investigates the seismic performance and design method of an innovative CFS shear wall system with in-frame corrugated steel sheathing based on previous studies. Shear wall and bearing wall specimens with in-frame corrugated steel sheathing are tested under combined lateral and gravity loading. Simplified numerical models of whole archetype buildings are established. The seismic performance evaluation is performed using methodology recommended in FEMA P695 and the seismic performance factors are examined. The test results show that the shear strength of the innovative shear wall is much higher than currently code certified wood-based shear walls in AISI S400. Also, the shear strength of bearing walls is approximately one-third of the shear strength of shear walls, which proves that bearing walls also contribute significant shear resistance in a structure. The seismic performance evaluation results verified that the existing seismic performance factors (R = Cd = 6.5 and [ ] = 3.0) for CFS shear walls with flat steel sheathings can also be used for the innovative shear wall system. The innovative CFS shear wall system with in-frame corrugated steel sheathing could be employed for mid-rise buildings in areas that are prone to high seismic and wind loads.
- 31 August 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 60, 105161
Shake table tests of a corrugated steel sheathed cold-formed steel structure
- 31 August 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 60, 105161
Shake table tests of a corrugated steel sheathed cold-formed steel structure
- Open Access
Probabilistic Seismic Assessment of CoSPSW Structures Using Fragility Functions
The corrugated steel plate shear wall (CoSPSW) is a new type of steel plate shear wall, in which corrugated wall plates instead of flat wall plates are adopted. The lateral stiffness and shear buckling capacity of the shear wall system could be significantly enhanced, and then, wall plate buckling under gravity loads would be mitigated. This paper presents a study on the probabilistic assessment of the seismic performance and vulnerability of CoSPSWs using fragility functions. The damage states and corresponding repair states of CoSPSWs were first established from experimental data. Then, incremental dynamic analyses were conducted on the CoSPSW structures. The structural and nonstructural fragility functions were developed, based on which the seismic performance and vulnerability of the CoSPSWs were obtained and compared with the conventional steel plate shear walls (SPSWs). It was shown that for various repair states, the 25th percentile PGA of the CoSPSW was always higher than the SPSWs with the same wall thickness and boundary frame, which indicated that the CoSPSW has a lower damage potential and better seismic performance than the SPSW.
Open AccessProbabilistic Seismic Assessment of CoSPSW Structures Using Fragility Functions
The corrugated steel plate shear wall (CoSPSW) is a new type of steel plate shear wall, in which corrugated wall plates instead of flat wall plates are adopted. The lateral stiffness and shear buckling capacity of the shear wall system could be significantly enhanced, and then, wall plate buckling under gravity loads would be mitigated. This paper presents a study on the probabilistic assessment of the seismic performance and vulnerability of CoSPSWs using fragility functions. The damage states and corresponding repair states of CoSPSWs were first established from experimental data. Then, incremental dynamic analyses were conducted on the CoSPSW structures. The structural and nonstructural fragility functions were developed, based on which the seismic performance and vulnerability of the CoSPSWs were obtained and compared with the conventional steel plate shear walls (SPSWs). It was shown that for various repair states, the 25th percentile PGA of the CoSPSW was always higher than the SPSWs with the same wall thickness and boundary frame, which indicated that the CoSPSW has a lower damage potential and better seismic performance than the SPSW.
- 1 December 2021
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 147 (12) , 04021210
Cold-Formed Steel Framed Shear Walls with In-Frame Corrugated Steel Sheathing
This paper presents the experimental results of an innovative configuration for cold-formed steel (CFS) framed shear walls using corrugated steel sheets as sheathing material. The shear wall configuration comprises corrugated steel sheathings placed inside the steel framing and therefore is known as an in-frame or sheet-in shear wall. The innovative shear wall configuration is noncombustible, is equal in thickness to adjacent walls, and avoids the difficulties inherent in the design and installation of the finish materials used in common corrugated steel sheathed shear walls. The test program in this research comprised cyclic testing of five groups of shear walls in which the stud arrangement, sheathing continuity, framing thickness, and wall aspect ratio varied. The results indicate that shear walls with a lower-profiled field stud and continuous sheathing had satisfactory performance with balanced shear strength and ease of assembly. Based on the test data, shear resistances of in-frame or sheet-in shear walls with corrugated steel sheathing under seismic load are recommended as the basis for design. These innovative shear walls exhibited substantially higher shear capacity than code-certified shear walls, and therefore can be used as a substitute for a lateral force–resisting system in midrise CFS light-framed buildings.
- 1 December 2021
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 147 (12) , 04021210
Cold-Formed Steel Framed Shear Walls with In-Frame Corrugated Steel Sheathing
This paper presents the experimental results of an innovative configuration for cold-formed steel (CFS) framed shear walls using corrugated steel sheets as sheathing material. The shear wall configuration comprises corrugated steel sheathings placed inside the steel framing and therefore is known as an in-frame or sheet-in shear wall. The innovative shear wall configuration is noncombustible, is equal in thickness to adjacent walls, and avoids the difficulties inherent in the design and installation of the finish materials used in common corrugated steel sheathed shear walls. The test program in this research comprised cyclic testing of five groups of shear walls in which the stud arrangement, sheathing continuity, framing thickness, and wall aspect ratio varied. The results indicate that shear walls with a lower-profiled field stud and continuous sheathing had satisfactory performance with balanced shear strength and ease of assembly. Based on the test data, shear resistances of in-frame or sheet-in shear walls with corrugated steel sheathing under seismic load are recommended as the basis for design. These innovative shear walls exhibited substantially higher shear capacity than code-certified shear walls, and therefore can be used as a substitute for a lateral force–resisting system in midrise CFS light-framed buildings.
- 1 November 2021
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 147 (11) , 04021171
Novel Energy Dissipation Bracing Designed for Corrugated Sheet–Sheathed Cold-Formed Steel Shear Wall
This study developed a special energy dissipation X-bracing for cold-formed steel (CFS) shear walls to improve the ductility of the corrugated steel sheathing. In previous research, CFS shear walls with corrugated sheathing demonstrated poor ductility under cyclic loading. The paper presents a potential solution by adding a special energy dissipation bracing (EDB) to improve the ductility of the corrugated sheet–sheathed shear walls. The EDB can be tuned according to the CFS shear wall base performance to achieve the highest postpeak deflection capacity, thereby significantly improving the seismic ductility. To prove the concept and analyze the feasibility of the new EDB, a test program of nine full-scale shear walls was conducted. The experimental results showed that with the tuned EDB, the corrugated steel sheet–sheathed shear walls had improved ductility with no considerable reduction in the initial stiffness and shear strength. Installing the proposed EDB can be an efficient approach to enhance the seismic performance of CFS-framed shear walls. Details of the test program and discussion are presented.
- 1 November 2021
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 147 (11) , 04021171
Novel Energy Dissipation Bracing Designed for Corrugated Sheet–Sheathed Cold-Formed Steel Shear Wall
This study developed a special energy dissipation X-bracing for cold-formed steel (CFS) shear walls to improve the ductility of the corrugated steel sheathing. In previous research, CFS shear walls with corrugated sheathing demonstrated poor ductility under cyclic loading. The paper presents a potential solution by adding a special energy dissipation bracing (EDB) to improve the ductility of the corrugated sheet–sheathed shear walls. The EDB can be tuned according to the CFS shear wall base performance to achieve the highest postpeak deflection capacity, thereby significantly improving the seismic ductility. To prove the concept and analyze the feasibility of the new EDB, a test program of nine full-scale shear walls was conducted. The experimental results showed that with the tuned EDB, the corrugated steel sheet–sheathed shear walls had improved ductility with no considerable reduction in the initial stiffness and shear strength. Installing the proposed EDB can be an efficient approach to enhance the seismic performance of CFS-framed shear walls. Details of the test program and discussion are presented.
- 1 October 2021
- Published by Elsevier in Structures
- Vol. 33, 4313-4329
Comparative analysis and design method of shear strength for hybrid SPR-SDS joints in thin-walled steel structures
- 1 October 2021
- Published by Elsevier in Structures
- Vol. 33, 4313-4329
Comparative analysis and design method of shear strength for hybrid SPR-SDS joints in thin-walled steel structures
- 17 February 2021
- Published by Taylor & Francis in Ferroelectrics
- Vol. 572 (1) , 118-134
Nonlinear pull-in analysis of LASMP laminated micro-plate considering micro-scale effect
This research concentrates on pull-in behavior of a micro-plate laminated with a novel material: light activated shape memory polymer (LASMP). Under light exposure, this material can realize dynamic Young’s modulus. With this feature, a LASMP laminated micro-plate model considering micro-scale effect and geometric nonlinearity is proposed. Dynamic equations of the micro-plate system are derived via Hamilton principle and solved by Galerkin method whose accuracy is validated by FEM. Effect of size dependency and dynamic Young’s modulus of LASMP on pull-in behavior of the micro-plate are studied. Present study provided a technique to manipulate pull-in phenomenon of electrically actuated micro-plate.
- 17 February 2021
- Published by Taylor & Francis in Ferroelectrics
- Vol. 572 (1) , 118-134
Nonlinear pull-in analysis of LASMP laminated micro-plate considering micro-scale effect
This research concentrates on pull-in behavior of a micro-plate laminated with a novel material: light activated shape memory polymer (LASMP). Under light exposure, this material can realize dynamic Young’s modulus. With this feature, a LASMP laminated micro-plate model considering micro-scale effect and geometric nonlinearity is proposed. Dynamic equations of the micro-plate system are derived via Hamilton principle and solved by Galerkin method whose accuracy is validated by FEM. Effect of size dependency and dynamic Young’s modulus of LASMP on pull-in behavior of the micro-plate are studied. Present study provided a technique to manipulate pull-in phenomenon of electrically actuated micro-plate.
- 1 November 2018
- Published by Elsevier in Journal of Constructional Steel Research
- Vol. 150, 430-441
Different slit configuration in corrugated sheathing of cold-formed steel shear wall
- 1 November 2018
- Published by Elsevier in Journal of Constructional Steel Research
- Vol. 150, 430-441
Different slit configuration in corrugated sheathing of cold-formed steel shear wall
- 1 November 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 144 (11)
Experimental Studies on Cyclic Behavior of Corrugated Steel Plate Shear Walls
Corrugated steel plate shear wall (CoSPSW) is a lateral load–resisting system in which corrugated infill steel wall panels are embedded inside a steel boundary frame. Compared to flat steel plate shear walls (SPSWs), elastic buckling capacity and lateral stiffness could be enhanced considerably, and gravity loads could be avoided when the load is perpendicular to the rib, or resisted when the load is parallel to the rib, which solves the long-lasting problem of flat wall buckling under gravity loads during construction. Cyclic quasi-static tests were conducted on three, 1/3-scale, 2-story, single-bay CoSPSW specimens with different corrugation orientation and configuration. All specimens showed highly ductile behavior and stable cyclic postbuckling performance. Compared to the SPSW specimen, CoSPSW specimens had much higher lateral stiffness and elastic buckling capacity, with less pinching in the hysteric curves. Different from the tension field action mechanism in SPSW, the lateral load–resisting mechanism in CoSPSWs was shear yielding, or inelastic shear buckling, depending on the corrugation configuration. The experimental results and their implication on seismic design are summarized and discussed.
- 1 November 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 144 (11)
Experimental Studies on Cyclic Behavior of Corrugated Steel Plate Shear Walls
Corrugated steel plate shear wall (CoSPSW) is a lateral load–resisting system in which corrugated infill steel wall panels are embedded inside a steel boundary frame. Compared to flat steel plate shear walls (SPSWs), elastic buckling capacity and lateral stiffness could be enhanced considerably, and gravity loads could be avoided when the load is perpendicular to the rib, or resisted when the load is parallel to the rib, which solves the long-lasting problem of flat wall buckling under gravity loads during construction. Cyclic quasi-static tests were conducted on three, 1/3-scale, 2-story, single-bay CoSPSW specimens with different corrugation orientation and configuration. All specimens showed highly ductile behavior and stable cyclic postbuckling performance. Compared to the SPSW specimen, CoSPSW specimens had much higher lateral stiffness and elastic buckling capacity, with less pinching in the hysteric curves. Different from the tension field action mechanism in SPSW, the lateral load–resisting mechanism in CoSPSWs was shear yielding, or inelastic shear buckling, depending on the corrugation configuration. The experimental results and their implication on seismic design are summarized and discussed.