Jonas Reber
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jonas Reber has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
- Klaas Paul Pruessmann
Institute for Biomedical Engineering ETH Zurich and University of Zurich Zurich Switzerland
10 shared publications Benjamin E. Dietrich
Institute for Biomedical Engineering, ETH Zurich and University of Zurich, Zurich, Switzerland
7 shared publications- David Otto Brunner
Institute for Biomedical Engineering, ETH Zurich and University of Zurich, Zurich, Switzerland
6 shared publications - Josip Marjanovic
Institute for Biomedical Engineering, University and ETH Zurich, 8092 Zurich, Switzerland
6 shared publications Klaas P. Pruessmann
Institute for Biomedical Engineering, ETH Zurich and University of Zurich, Zurich, Switzerland
5 shared publicationsChristian Vogt
Electronics Laboratory, ETH Zürich, Gloriastrasse 35, 8092, Zürich, Switzerland
4 shared publications
Latest Publications
- 3 December 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 85 (5) , 2507-2523
T‐Hex: Tilted hexagonal grids for rapid 3D imaging
Purpose The purpose of this work is to devise and demonstrate an encoding strategy for 3D MRI that reconciles high speed with flexible segmentation, uniform k‐space density, and benign effects. Methods Fast sampling of a 3D k‐space is typically accomplished by 2D readouts per shot using EPI trains or spiral readouts. Tilted hexagonal (T‐Hex) sampling is a way of acquiring more k‐space volume per excitation while maintaining uniform sampling density and a smooth filter. The k‐space volume covered per shot is controlled by the tilting angle. Image reconstruction is performed with a 3D extension of the iterative SENSE approach, incorporating actual field dynamics and static off‐resonance. T‐Hex imaging is compared with established 3D schemes in terms of speed and noise performance. Results Tilted hexagonal acquisition is found to achieve greater imaging speed than known alternatives, particularly in combination with spiral trajectories. The interplay of the proposed 3D trajectories, array detection, and off‐resonance is successfully addressed by iterative inversion of the full signal model. Enhanced coverage per shot is of greatest utility for high speed in an intermediate resolution regime of 1 to 4 mm. T‐Hex EPI combines the benefits of extended coverage per shot with increased robustness against off‐resonance effects. Conclusion Sampling of tilted hexagonal grids is a feasible means of gaining 3D imaging speed with near‐optimal SNR efficiency and benign depiction properties. It is a particularly promising technique for time‐resolved applications such as fMRI.
- 3 December 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 85 (5) , 2507-2523
T‐Hex: Tilted hexagonal grids for rapid 3D imaging
Purpose The purpose of this work is to devise and demonstrate an encoding strategy for 3D MRI that reconciles high speed with flexible segmentation, uniform k‐space density, and benign effects. Methods Fast sampling of a 3D k‐space is typically accomplished by 2D readouts per shot using EPI trains or spiral readouts. Tilted hexagonal (T‐Hex) sampling is a way of acquiring more k‐space volume per excitation while maintaining uniform sampling density and a smooth filter. The k‐space volume covered per shot is controlled by the tilting angle. Image reconstruction is performed with a 3D extension of the iterative SENSE approach, incorporating actual field dynamics and static off‐resonance. T‐Hex imaging is compared with established 3D schemes in terms of speed and noise performance. Results Tilted hexagonal acquisition is found to achieve greater imaging speed than known alternatives, particularly in combination with spiral trajectories. The interplay of the proposed 3D trajectories, array detection, and off‐resonance is successfully addressed by iterative inversion of the full signal model. Enhanced coverage per shot is of greatest utility for high speed in an intermediate resolution regime of 1 to 4 mm. T‐Hex EPI combines the benefits of extended coverage per shot with increased robustness against off‐resonance effects. Conclusion Sampling of tilted hexagonal grids is a feasible means of gaining 3D imaging speed with near‐optimal SNR efficiency and benign depiction properties. It is a particularly promising technique for time‐resolved applications such as fMRI.
- Open Access
- 17 July 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1
Publisher Correction: Detector clothes for MRI: A wearable array receiver based on liquid metal in elastic tubes
An amendment to this paper has been published and can be accessed via a link at the top of the paper.
- 17 July 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1
Open AccessPublisher Correction: Detector clothes for MRI: A wearable array receiver based on liquid metal in elastic tubes
An amendment to this paper has been published and can be accessed via a link at the top of the paper.
- 16 March 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (4) , 1933-1946
High‐resolution short‐T2 MRI using a high‐performance gradient
Purpose: To achieve high resolution in imaging of short‐T2 materials and tissues by using a high‐performance human‐sized gradient insert with strength up to 200 mT/m and 100% duty cycle.Methods: Dedicated short‐T2 methodology and hardware are used, such as the pointwise encoding time reduction with radial acquisition (PETRA) technique with modulated excitation pulses, optimized radio‐frequency hardware, and a high‐performance gradient insert. A theoretical analysis of actual spatial resolution and SNR is provided to support the choice of scan parameters and interpretation of the results. Imaging is performed in resolution phantoms, animal specimen, and human volunteers at both conventional and maximum available gradient strengths and compared using image subtraction.Results: Calculations suggest that increasing gradient strength beyond conventional values considerably improves both actual resolution and SNR efficiency in short‐T2 imaging. Resolution improvements are confirmed in all investigated samples, in particular 2 mm slots were resolved in a hard‐plastic plate with T2 ≈ 10 μs and in vivo musculoskeletal images were acquired at isotropic 200 μm resolution. Expected improvements in signal yield are realized in fine structures benefitting from high resolution but to less extent in regions of low contrast where decay‐related blurring leads to signal overlap between neighboring locations.Conclusion: Strong gradients with high duty cycle enable short‐T2 imaging at unprecedentedly high resolution, holding the potential for improving MRI of, eg, bone, tendon, lung, or teeth. Moreover, it allows direct access of tissues with T2 of tens of microseconds such as myelin or collagen.
- 16 March 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (4) , 1933-1946
High‐resolution short‐T2 MRI using a high‐performance gradient
Purpose: To achieve high resolution in imaging of short‐T2 materials and tissues by using a high‐performance human‐sized gradient insert with strength up to 200 mT/m and 100% duty cycle.Methods: Dedicated short‐T2 methodology and hardware are used, such as the pointwise encoding time reduction with radial acquisition (PETRA) technique with modulated excitation pulses, optimized radio‐frequency hardware, and a high‐performance gradient insert. A theoretical analysis of actual spatial resolution and SNR is provided to support the choice of scan parameters and interpretation of the results. Imaging is performed in resolution phantoms, animal specimen, and human volunteers at both conventional and maximum available gradient strengths and compared using image subtraction.Results: Calculations suggest that increasing gradient strength beyond conventional values considerably improves both actual resolution and SNR efficiency in short‐T2 imaging. Resolution improvements are confirmed in all investigated samples, in particular 2 mm slots were resolved in a hard‐plastic plate with T2 ≈ 10 μs and in vivo musculoskeletal images were acquired at isotropic 200 μm resolution. Expected improvements in signal yield are realized in fine structures benefitting from high resolution but to less extent in regions of low contrast where decay‐related blurring leads to signal overlap between neighboring locations.Conclusion: Strong gradients with high duty cycle enable short‐T2 imaging at unprecedentedly high resolution, holding the potential for improving MRI of, eg, bone, tendon, lung, or teeth. Moreover, it allows direct access of tissues with T2 of tens of microseconds such as myelin or collagen.
- 16 December 2019
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (1) , 89-102
Motion detection with NMR markers using real‐time field tracking in the laboratory frame
Purpose To enhance the utility of motion detection with nuclear magnetic resonance (NMR) markers by removing the need for sequence‐dependent calibration. Methods Two sets of NMR markers are used for simultaneous observation of magnetic field dynamics during imaging procedures. A set of stationary markers at known positions in the laboratory frame serves to determine the field evolution in that frame. Concurrent recording from a set of head‐mounted markers then permits calculating their lab‐frame positions and derived rigid‐body motion parameters. The precision and accuracy of this approach are evaluated relative to current calibration‐based solutions. Use for prospective motion correction is then demonstrated in high‐resolution imaging of long scan duration. Results Motion detection with real‐time field tracking overcomes the need for explicit calibration without compromising precision, which is assessed at 10 to 30 µm. Relative to full conventional calibration, it is found to offer superior robustness against thermal drift. Relative to more economical modes of calibration, it achieves substantially higher accuracy. Prospective motion correction based on real‐time field tracking resulted in consistently high image quality even when head motion exceeded the image resolution by one order of magnitude. Conclusion Real‐time field tracking enables motion detection with NMR markers without calibration overhead and thus overcomes a key obstacle toward routine use. In addition, it renders this mode of motion tracking more robust against system imperfections.
- 16 December 2019
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (1) , 89-102
Motion detection with NMR markers using real‐time field tracking in the laboratory frame
Purpose To enhance the utility of motion detection with nuclear magnetic resonance (NMR) markers by removing the need for sequence‐dependent calibration. Methods Two sets of NMR markers are used for simultaneous observation of magnetic field dynamics during imaging procedures. A set of stationary markers at known positions in the laboratory frame serves to determine the field evolution in that frame. Concurrent recording from a set of head‐mounted markers then permits calculating their lab‐frame positions and derived rigid‐body motion parameters. The precision and accuracy of this approach are evaluated relative to current calibration‐based solutions. Use for prospective motion correction is then demonstrated in high‐resolution imaging of long scan duration. Results Motion detection with real‐time field tracking overcomes the need for explicit calibration without compromising precision, which is assessed at 10 to 30 µm. Relative to full conventional calibration, it is found to offer superior robustness against thermal drift. Relative to more economical modes of calibration, it achieves substantially higher accuracy. Prospective motion correction based on real‐time field tracking resulted in consistently high image quality even when head motion exceeded the image resolution by one order of magnitude. Conclusion Real‐time field tracking enables motion detection with NMR markers without calibration overhead and thus overcomes a key obstacle toward routine use. In addition, it renders this mode of motion tracking more robust against system imperfections.
- Open Access
Advances in Spiral fMRI: A High-resolution Study with Single-shot Acquisition
Spiral fMRI has been put forward as a viable alternative to rectilinear echo-planar imaging, in particular due to its enhanced average k-space speed and thus high acquisition efficiency. This renders spirals attractive for contemporary fMRI applications that require high spatiotemporal resolution, such as laminar or columnar fMRI. However, in practice, spiral fMRI is typically hampered by its reduced robustness and ensuing blurring artifacts, which arise from imperfections in both static and dynamic magnetic fields. Recently, these limitations have been overcome by the concerted application of an expanded signal model that accounts for such field imperfections, and its inversion by iterative image reconstruction. In the challenging ultra-high field environment of 7 Tesla, where field inhomogeneity effects are aggravated, both multi-shot and single-shot 2D spiral imaging at sub-millimeter resolution was demonstrated with high depiction quality and anatomical congruency. In this work, we further these advances towards a time series application of spiral readouts, namely, single-shot spiral BOLD fMRI at 0.8 mm in-plane resolution. We demonstrate that high-resolution spiral fMRI at 7 T is not only feasible, but delivers both excellent image quality, BOLD sensitivity, and spatial specificity of the activation maps, with little artifactual blurring. Furthermore, we show the versatility of the approach with a combined in/out spiral readout at a more typical resolution (1.5 mm), where the high acquisition efficiency allows to acquire two images per shot for improved sensitivity by echo combination. Highlights: This work reports the first fMRI study at 7T with high-resolution spiral readout gradient waveforms. We achieve spiral fMRI with sub-millimeter resolution (0.8 mm, FOV 230 mm), acquired in a single shot (36 slices in 3.3 s). Spiral images exhibit intrinsic geometric congruency to anatomical scans, and spatially specific activation patterns. Image reconstruction rests on a signal model expanded by measured trajectories and static field maps, inverted by cg-SENSE. We assess generalizability of the approach for spiral in/out readouts, providing two images per shot (1.5 mm resolution).
Open AccessAdvances in Spiral fMRI: A High-resolution Study with Single-shot Acquisition
Spiral fMRI has been put forward as a viable alternative to rectilinear echo-planar imaging, in particular due to its enhanced average k-space speed and thus high acquisition efficiency. This renders spirals attractive for contemporary fMRI applications that require high spatiotemporal resolution, such as laminar or columnar fMRI. However, in practice, spiral fMRI is typically hampered by its reduced robustness and ensuing blurring artifacts, which arise from imperfections in both static and dynamic magnetic fields. Recently, these limitations have been overcome by the concerted application of an expanded signal model that accounts for such field imperfections, and its inversion by iterative image reconstruction. In the challenging ultra-high field environment of 7 Tesla, where field inhomogeneity effects are aggravated, both multi-shot and single-shot 2D spiral imaging at sub-millimeter resolution was demonstrated with high depiction quality and anatomical congruency. In this work, we further these advances towards a time series application of spiral readouts, namely, single-shot spiral BOLD fMRI at 0.8 mm in-plane resolution. We demonstrate that high-resolution spiral fMRI at 7 T is not only feasible, but delivers both excellent image quality, BOLD sensitivity, and spatial specificity of the activation maps, with little artifactual blurring. Furthermore, we show the versatility of the approach with a combined in/out spiral readout at a more typical resolution (1.5 mm), where the high acquisition efficiency allows to acquire two images per shot for improved sensitivity by echo combination. Highlights: This work reports the first fMRI study at 7T with high-resolution spiral readout gradient waveforms. We achieve spiral fMRI with sub-millimeter resolution (0.8 mm, FOV 230 mm), acquired in a single shot (36 slices in 3.3 s). Spiral images exhibit intrinsic geometric congruency to anatomical scans, and spatially specific activation patterns. Image reconstruction rests on a signal model expanded by measured trajectories and static field maps, inverted by cg-SENSE. We assess generalizability of the approach for spiral in/out readouts, providing two images per shot (1.5 mm resolution).
- 30 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (4) , 1138-1148
A Reconfigurable Platform for Magnetic Resonance Data Acquisition and Processing
Developments in magnetic resonance imaging (MRI) in the last decades show a trend towards a growing number of array coils and an increasing use of a wide variety of sensors. Associated cabling and safety issues have been addressed by moving data acquisition closer to the coil. However, with the increasing number of radio-frequency (RF) channels and trend towards higher acquisition duty-cycles, the data amount is growing, which poses challenges for throughput and data handling. As it is becoming a limitation, early compression and preprocessing is becoming ever more important. Additionally, sensors deliver diverse data, which require distinct and often low-latency processing for run-time updates of scanner operation. To address these challenges, we propose the transition to reconfigurable hardware with an application tailored assembly of interfaces and real-time processing resources. We present an integrated solution based on a system-on-chip (SoC), which offers sufficient throughput and hardware-based parallel processing power for very challenging applications. It is equipped with fiber-optical modules serving as versatile interfaces for modular systems with in-field operation. We demonstrate the utility of the platform on the example of concurrent imaging and field sensing with hardware-based coil compression and trajectory extraction. The preprocessed data are then used in expanded encoding model based image reconstruction of single-shot and segmented spirals as used in time-series and anatomical imaging respectively.
- 30 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (4) , 1138-1148
A Reconfigurable Platform for Magnetic Resonance Data Acquisition and Processing
Developments in magnetic resonance imaging (MRI) in the last decades show a trend towards a growing number of array coils and an increasing use of a wide variety of sensors. Associated cabling and safety issues have been addressed by moving data acquisition closer to the coil. However, with the increasing number of radio-frequency (RF) channels and trend towards higher acquisition duty-cycles, the data amount is growing, which poses challenges for throughput and data handling. As it is becoming a limitation, early compression and preprocessing is becoming ever more important. Additionally, sensors deliver diverse data, which require distinct and often low-latency processing for run-time updates of scanner operation. To address these challenges, we propose the transition to reconfigurable hardware with an application tailored assembly of interfaces and real-time processing resources. We present an integrated solution based on a system-on-chip (SoC), which offers sufficient throughput and hardware-based parallel processing power for very challenging applications. It is equipped with fiber-optical modules serving as versatile interfaces for modular systems with in-field operation. We demonstrate the utility of the platform on the example of concurrent imaging and field sensing with hardware-based coil compression and trajectory extraction. The preprocessed data are then used in expanded encoding model based image reconstruction of single-shot and segmented spirals as used in time-series and anatomical imaging respectively.
- 2 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (4) , 997-1007
An In-Bore Receiver for Magnetic Resonance Imaging
In magnetic resonance imaging, the use of array detection and the number of detector elements have seen a steady increase over the past two decades. As a result, per-channel analog connection via long coaxial cable, as commonly used, poses an increasing challenge in terms of handling, safety, and coupling among cables. This situation is exacerbated when complementary recording of radiofrequency transmission or NMR-based magnetic field sensing further add to channel counts. A generic way of addressing this trend is the transition to digital signal transmission, enabled by digitization and first-level digital processing close to detector coils and sensors in the magnet bore. The foremost challenge that comes with this approach is to achieve high dynamic range, linearity, and phase stability despite interference by strong static, audiofrequency, and radiofrequency fields. The present work reports implementation of a 16-channel in-bore receiver, performing signal digitization and processing with subsequent optical transmission over fiber. Along with descriptions of the system design and construction, performance evaluation is reported. The resulting device is fully MRI compatible providing practically equal performance and signal quality compared to state-of-the-art RF digitizers operating outside the magnet. Its use is demonstrated by examples of head imaging and magnetic field recording.
- 2 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (4) , 997-1007
An In-Bore Receiver for Magnetic Resonance Imaging
In magnetic resonance imaging, the use of array detection and the number of detector elements have seen a steady increase over the past two decades. As a result, per-channel analog connection via long coaxial cable, as commonly used, poses an increasing challenge in terms of handling, safety, and coupling among cables. This situation is exacerbated when complementary recording of radiofrequency transmission or NMR-based magnetic field sensing further add to channel counts. A generic way of addressing this trend is the transition to digital signal transmission, enabled by digitization and first-level digital processing close to detector coils and sensors in the magnet bore. The foremost challenge that comes with this approach is to achieve high dynamic range, linearity, and phase stability despite interference by strong static, audiofrequency, and radiofrequency fields. The present work reports implementation of a 16-channel in-bore receiver, performing signal digitization and processing with subsequent optical transmission over fiber. Along with descriptions of the system design and construction, performance evaluation is reported. The resulting device is fully MRI compatible providing practically equal performance and signal quality compared to state-of-the-art RF digitizers operating outside the magnet. Its use is demonstrated by examples of head imaging and magnetic field recording.
- 19 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (3) , 806-815
Gradient Response Harvesting for Continuous System Characterization During MR Sequences
MRI gradient systems are required to generate magnetic field gradient waveforms with very high fidelity. This is commonly implemented by gradient system calibration and pre-emphasis. However, a number of mechanisms, particularly thermal changes, cause variation in the gradient response over time, which cannot be addressed by calibration approaches. To overcome this limitation, we present a novel method termed gradient response harvesting, where the gradient response is continuously characterized during the course of a normal MR sequence. Snippets of field measurements are repeatedly acquired during an MR sequence, and from these multiple field measurements and the known nominal MR sequence gradients, the gradient response and gradient/field offsets are calculated. The calculation is implemented in a model-based and a model-free variant. The method is demonstrated for EPI with high gradient duty-cycle, where the continuous gradient characterization is used to obtain k-space trajectory estimates that are employed in the subsequent image reconstruction. During the course of the MR sequence, changes in both the envelope and the phase of the gradient response functions were observed, including shifts of mechanical resonances. The gradient response changes were also reflected in the calculated uninterrupted gradient waveforms and thus in the k-space trajectories. Using the updated encoding information in the image reconstruction removed ghosting artifacts, that otherwise impaired the image quality. We introduced the concept of gradient response harvesting and demonstrated its feasibility. The obtained gradient response functions may be used for quality assurance/preventive maintenance, real-time adaptation of gradient pre-emphasis or to calculate uninterrupted gradient field evolutions.
- 19 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (3) , 806-815
Gradient Response Harvesting for Continuous System Characterization During MR Sequences
MRI gradient systems are required to generate magnetic field gradient waveforms with very high fidelity. This is commonly implemented by gradient system calibration and pre-emphasis. However, a number of mechanisms, particularly thermal changes, cause variation in the gradient response over time, which cannot be addressed by calibration approaches. To overcome this limitation, we present a novel method termed gradient response harvesting, where the gradient response is continuously characterized during the course of a normal MR sequence. Snippets of field measurements are repeatedly acquired during an MR sequence, and from these multiple field measurements and the known nominal MR sequence gradients, the gradient response and gradient/field offsets are calculated. The calculation is implemented in a model-based and a model-free variant. The method is demonstrated for EPI with high gradient duty-cycle, where the continuous gradient characterization is used to obtain k-space trajectory estimates that are employed in the subsequent image reconstruction. During the course of the MR sequence, changes in both the envelope and the phase of the gradient response functions were observed, including shifts of mechanical resonances. The gradient response changes were also reflected in the calculated uninterrupted gradient waveforms and thus in the k-space trajectories. Using the updated encoding information in the image reconstruction removed ghosting artifacts, that otherwise impaired the image quality. We introduced the concept of gradient response harvesting and demonstrated its feasibility. The obtained gradient response functions may be used for quality assurance/preventive maintenance, real-time adaptation of gradient pre-emphasis or to calculate uninterrupted gradient field evolutions.
- 11 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (6) , 1542-1548
On the Bending and Stretching of Liquid Metal Receive Coils for Magnetic Resonance Imaging
The eGaIn coil on neoprene demonstrated in this paper presents a stretchable radio frequency receive coil for MRI. The coil with dimensions 86mm × 70mm is tuned to resonate at 128MHz for 3T MRI. We investigate the effect of stretching (up to 40% strain) and bending (50mm radius of curvature) of the coil on the coil's resistance and resonance frequency. Measurements and simulations show a decrease in resonance frequency of 2.5MHz per 10% strain. The higher resistivity of liquid metal compared to copper reduces the SNR of MRI scans by 2.1dB; therefore a trade-off between flexibility and performance remains. Nevertheless, we have successfully performed MRI scans with the liquid metal coil.
- 11 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (6) , 1542-1548
On the Bending and Stretching of Liquid Metal Receive Coils for Magnetic Resonance Imaging
The eGaIn coil on neoprene demonstrated in this paper presents a stretchable radio frequency receive coil for MRI. The coil with dimensions 86mm × 70mm is tuned to resonate at 128MHz for 3T MRI. We investigate the effect of stretching (up to 40% strain) and bending (50mm radius of curvature) of the coil on the coil's resistance and resonance frequency. Measurements and simulations show a decrease in resonance frequency of 2.5MHz per 10% strain. The higher resistivity of liquid metal compared to copper reduces the SNR of MRI scans by 2.1dB; therefore a trade-off between flexibility and performance remains. Nevertheless, we have successfully performed MRI scans with the liquid metal coil.
- 21 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 11 (6) , 1245-1255
A Fully Integrated Dual-Channel On-Coil CMOS Receiver for Array Coils in 1.5–10.5 T MRI
Magnetic resonance imaging (MRI) is among the most important medical imaging modalities. Coil arrays and receivers with high channel counts (16 and more) have to be deployed to obtain the image quality and acquisition speed required by modern clinical protocols. In this paper, we report the theoretical analysis, the system-level design, and the circuit implementation of the first receiver IC (RXIC) for clinical MRI fully integrated in a modern CMOS technology. The dual-channel RXIC sits directly on the sensor coil, thus eliminating any RF cable otherwise required to transport the information out of the magnetic field. The first stage LNA was implemented using a noise-canceling architecture providing a highly reflective input used to decouple the individual channels of the array. Digitization is performed directly on-chip at base-band by means of a delta-sigma modulator, allowing the subsequent optical transmission of data. The presented receiver, implemented in a $\mathbf {{130}\,{nm}}$ CMOS technology, is compatible with MRI scanners up to $\mathbf {{10.5}\,{T}}$. It reaches sub-$\mathbf {{1}\,{dB}}$ noise figure for $\mathbf {{3\!-\! 7}\,{T}}$ MRI units and features a dynamic range up to $\mathbf {{81.9}\,{dB}}$ at a power consumption below $\mathbf {{240}\,{mW}}$ per channel, with an area occupation of $\mathbf {{22}\,{mm^2}}$. Mounted on a small-sized printed circuit board (PCB), the receiver IC has been employed in a commercial MRI scanner to acquire in-vivo images matching the quality of traditional systems, demonstrating the first step toward multichannel wearable MRI array coils.- 21 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 11 (6) , 1245-1255
A Fully Integrated Dual-Channel On-Coil CMOS Receiver for Array Coils in 1.5–10.5 T MRI
Magnetic resonance imaging (MRI) is among the most important medical imaging modalities. Coil arrays and receivers with high channel counts (16 and more) have to be deployed to obtain the image quality and acquisition speed required by modern clinical protocols. In this paper, we report the theoretical analysis, the system-level design, and the circuit implementation of the first receiver IC (RXIC) for clinical MRI fully integrated in a modern CMOS technology. The dual-channel RXIC sits directly on the sensor coil, thus eliminating any RF cable otherwise required to transport the information out of the magnetic field. The first stage LNA was implemented using a noise-canceling architecture providing a highly reflective input used to decouple the individual channels of the array. Digitization is performed directly on-chip at base-band by means of a delta-sigma modulator, allowing the subsequent optical transmission of data. The presented receiver, implemented in a $\mathbf {{130}\,{nm}}$ CMOS technology, is compatible with MRI scanners up to $\mathbf {{10.5}\,{T}}$. It reaches sub-$\mathbf {{1}\,{dB}}$ noise figure for $\mathbf {{3\!-\! 7}\,{T}}$ MRI units and features a dynamic range up to $\mathbf {{81.9}\,{dB}}$ at a power consumption below $\mathbf {{240}\,{mW}}$ per channel, with an area occupation of $\mathbf {{22}\,{mm^2}}$. Mounted on a small-sized printed circuit board (PCB), the receiver IC has been employed in a commercial MRI scanner to acquire in-vivo images matching the quality of traditional systems, demonstrating the first step toward multichannel wearable MRI array coils.