High‐resolution short‐T2 MRI using a high‐performance gradient
- 16 March 2020
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (4) , 1933-1946
Abstract
Purpose: To achieve high resolution in imaging of short‐T2 materials and tissues by using a high‐performance human‐sized gradient insert with strength up to 200 mT/m and 100% duty cycle.Methods: Dedicated short‐T2 methodology and hardware are used, such as the pointwise encoding time reduction with radial acquisition (PETRA) technique with modulated excitation pulses, optimized radio‐frequency hardware, and a high‐performance gradient insert. A theoretical analysis of actual spatial resolution and SNR is provided to support the choice of scan parameters and interpretation of the results. Imaging is performed in resolution phantoms, animal specimen, and human volunteers at both conventional and maximum available gradient strengths and compared using image subtraction.Results: Calculations suggest that increasing gradient strength beyond conventional values considerably improves both actual resolution and SNR efficiency in short‐T2 imaging. Resolution improvements are confirmed in all investigated samples, in particular 2 mm slots were resolved in a hard‐plastic plate with T2 ≈ 10 μs and in vivo musculoskeletal images were acquired at isotropic 200 μm resolution. Expected improvements in signal yield are realized in fine structures benefitting from high resolution but to less extent in regions of low contrast where decay‐related blurring leads to signal overlap between neighboring locations.Conclusion: Strong gradients with high duty cycle enable short‐T2 imaging at unprecedentedly high resolution, holding the potential for improving MRI of, eg, bone, tendon, lung, or teeth. Moreover, it allows direct access of tissues with T2 of tens of microseconds such as myelin or collagen.Keywords
This publication has 43 references indexed in Scilit:
- Direct magnetic resonance detection of myelin and prospects for quantitative imaging of myelin densityProceedings of the National Academy of Sciences, 2012
- RF coil considerations for short‐T2 MRIMagnetic Resonance in Medicine, 2010
- Quantitative 31P NMR spectroscopy and 1H MRI measurements of bone mineral and matrix density differentiate metabolic bone diseases in rat modelsBone, 2010
- Magnetization transfer contrast imaging in bovine and human cortical bone applying an ultrashort echo time sequence at 3 TeslaMagnetic Resonance in Medicine, 2009
- Gapped pulses for frequency-swept MRIJournal of Magnetic Resonance, 2008
- Selective 3D ultrashort TE imaging: comparison of “dual-echo” acquisition and magnetization preparation for improving short-T 2 contrastMagnetic Resonance Materials in Physics, Biology and Medicine, 2007
- Three‐dimensional radial ultrashort echo‐time imaging with T2 adapted samplingMagnetic Resonance in Medicine, 2006
- Magnetic resonance imaging of the Achilles tendon using ultrashort TE (UTE) pulse sequencesClinical Radiology, 2004
- Advances in sensitivity encoding with arbitrary k‐space trajectoriesMagnetic Resonance in Medicine, 2001
- Sensitivity and resolution in NMR imagingJournal of Magnetic Resonance (1969), 1987