Ajay K. Wakhloo
Research Subjects
Ajay K. Wakhloo has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Matthew J. Gounis
New England Center for Stroke Research, Department of Radiology, University of Massachusetts Chan Medical School, Worcester, Massachusetts, USA
3 shared publications - Ralf Siekmann
Department of Neuroradiology (R.S.), Klinikum Kassel, Kassel, Germany
3 shared publications - Ajit S. Puri
Division of Neurointerventional Radiology, Department of Radiology, University of Massachusetts Medical Center, Worcester, USA
2 shared publications - Srinivasan Vedantham
University of Arizona, Department of Biomedical Engineering, Tucson, Arizona, United States
2 shared publications - Alessandra Biondi
Department of Interventional Neuroradiology, Besançon University Hospital, Besançon, France
1 shared publication - Ali Shaibani
Department of Radiology, Ann and Robert H. Lurie Children’s Hospital of Chicago, IL (A.S.).
1 shared publication
Latest Publications
- 18 February 2021
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 42 (4) , 701-707
CTA Evaluation of Basilar Septations: An Entity Better Characterized as Aberrant Basilar Fenestrations
BACKGROUND AND PURPOSE: A basilar artery intraluminal septation is an exceedingly rarely reported, presumed congenital abnormality. In our clinical practice, we have occasionally noticed an intraluminal band within the inferior aspect of the basilar artery on CTA. Furthermore, we have noticed, at times, the presence of a punctate calcification associated with this finding. We hypothesized that what previous studies have called “basilar septations” in fact represent miniature and thus aberrant basilar fenestrations. MATERIALS AND METHODS: We retrospectively reviewed CTA studies obtained between January 1, 2017, and August 31, 2019. Identified intraluminal basilar abnormalities were classified as either basilar septations or basilar fenestrations. Association with other posterior circulation abnormalities was documented. RESULTS: A total of 3509 studies were examined. A basilar intraluminal abnormality was evident in 80 patients (2.3%). Of these 80 patients, 59 were classified as having a basilar fenestration (1.7%) and 21 were classified as having basilar septations (0.6%). Associated calcification was evident in 3 of the basilar fenestration cases and 13 of the basilar septation cases. CONCLUSIONS: Basilar septations most likely represent and should be referred to as aberrant basilar fenestrations. They should be interpreted as benign congenital incidental findings and should not be misinterpreted as focal dissections or arterial webs. Important variations in the morphology of aberrant basilar fenestrations exist, including areas of thinning, varying thickness, and nodularity. Therefore, when associated with calcification or nodularity, aberrant basilar fenestrations should not be confused with focal intraluminal thrombi or calcified or noncalcified emboli.
- 18 February 2021
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 42 (4) , 701-707
CTA Evaluation of Basilar Septations: An Entity Better Characterized as Aberrant Basilar Fenestrations
BACKGROUND AND PURPOSE: A basilar artery intraluminal septation is an exceedingly rarely reported, presumed congenital abnormality. In our clinical practice, we have occasionally noticed an intraluminal band within the inferior aspect of the basilar artery on CTA. Furthermore, we have noticed, at times, the presence of a punctate calcification associated with this finding. We hypothesized that what previous studies have called “basilar septations” in fact represent miniature and thus aberrant basilar fenestrations. MATERIALS AND METHODS: We retrospectively reviewed CTA studies obtained between January 1, 2017, and August 31, 2019. Identified intraluminal basilar abnormalities were classified as either basilar septations or basilar fenestrations. Association with other posterior circulation abnormalities was documented. RESULTS: A total of 3509 studies were examined. A basilar intraluminal abnormality was evident in 80 patients (2.3%). Of these 80 patients, 59 were classified as having a basilar fenestration (1.7%) and 21 were classified as having basilar septations (0.6%). Associated calcification was evident in 3 of the basilar fenestration cases and 13 of the basilar septation cases. CONCLUSIONS: Basilar septations most likely represent and should be referred to as aberrant basilar fenestrations. They should be interpreted as benign congenital incidental findings and should not be misinterpreted as focal dissections or arterial webs. Important variations in the morphology of aberrant basilar fenestrations exist, including areas of thinning, varying thickness, and nodularity. Therefore, when associated with calcification or nodularity, aberrant basilar fenestrations should not be confused with focal intraluminal thrombi or calcified or noncalcified emboli.
- Open Access
- 1 January 2020
- Published by Indian Journal of Scientific Research in Indian Journal of Scientific Research
- Vol. 10 (2) , 55
STUDY OF PERINATALOUTCOME IN PATIENTS PRESENTING WITH FIRST TRIMESTER BLEEDING
International Journal of Science and Research (IJSR) Calls for Unique, Unpublished research papers in Engineering and Science
- 1 January 2020
- Published by Indian Journal of Scientific Research in Indian Journal of Scientific Research
- Vol. 10 (2) , 55
Open AccessSTUDY OF PERINATALOUTCOME IN PATIENTS PRESENTING WITH FIRST TRIMESTER BLEEDING
International Journal of Science and Research (IJSR) Calls for Unique, Unpublished research papers in Engineering and Science
- Open Access
- 19 January 2017
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 38 (3) , 442-449
Reduced Patient Radiation Exposure during Neurodiagnostic and Interventional X-Ray Angiography with a New Imaging Platform
BACKGROUND AND PURPOSE: Advancements in medical device and imaging technology as well as accruing clinical evidence have accelerated the growth of the endovascular treatment of cerebrovascular diseases. However, the augmented role of these procedures raises concerns about the radiation dose to patients and operators. We evaluated patient doses from an x-ray imaging platform with radiation dose–reduction technology, which combined image noise reduction, motion correction, and contrast-dependent temporal averaging with optimized x-ray exposure settings. MATERIALS AND METHODS: In this single-center, retrospective study, cumulative dose-area product inclusive of fluoroscopy, angiography, and 3D acquisitions for all neurovascular procedures performed during a 2-year period on the dose-reduction platform were compared with a reference platform. Key study features were the following: The neurointerventional radiologist could select the targeted dose reduction for each patient with the dose-reduction platform, and the statistical analyses included patient characteristics and the neurointerventional radiologist as covariates. The analyzed outcome measures were cumulative dose (kerma)-area product, fluoroscopy duration, and administered contrast volume. RESULTS: A total of 1238 neurointerventional cases were included, of which 914 and 324 were performed on the reference and dose-reduction platforms, respectively. Over all diagnostic and neurointerventional procedures, the cumulative dose-area product was significantly reduced by 53.2% (mean reduction, 160.3 Gy × cm2; P < .0001), fluoroscopy duration was marginally significantly increased (mean increase, 5.2 minutes; P = .0491), and contrast volume was nonsignificantly increased (mean increase, 15.3 mL; P = .1616) with the dose-reduction platform. CONCLUSIONS: A significant reduction in patient radiation dose is achievable during neurovascular procedures by using dose-reduction technology with a minimal impact on workflow.
- 19 January 2017
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 38 (3) , 442-449
Open AccessReduced Patient Radiation Exposure during Neurodiagnostic and Interventional X-Ray Angiography with a New Imaging Platform
BACKGROUND AND PURPOSE: Advancements in medical device and imaging technology as well as accruing clinical evidence have accelerated the growth of the endovascular treatment of cerebrovascular diseases. However, the augmented role of these procedures raises concerns about the radiation dose to patients and operators. We evaluated patient doses from an x-ray imaging platform with radiation dose–reduction technology, which combined image noise reduction, motion correction, and contrast-dependent temporal averaging with optimized x-ray exposure settings. MATERIALS AND METHODS: In this single-center, retrospective study, cumulative dose-area product inclusive of fluoroscopy, angiography, and 3D acquisitions for all neurovascular procedures performed during a 2-year period on the dose-reduction platform were compared with a reference platform. Key study features were the following: The neurointerventional radiologist could select the targeted dose reduction for each patient with the dose-reduction platform, and the statistical analyses included patient characteristics and the neurointerventional radiologist as covariates. The analyzed outcome measures were cumulative dose (kerma)-area product, fluoroscopy duration, and administered contrast volume. RESULTS: A total of 1238 neurointerventional cases were included, of which 914 and 324 were performed on the reference and dose-reduction platforms, respectively. Over all diagnostic and neurointerventional procedures, the cumulative dose-area product was significantly reduced by 53.2% (mean reduction, 160.3 Gy × cm2; P < .0001), fluoroscopy duration was marginally significantly increased (mean increase, 5.2 minutes; P = .0491), and contrast volume was nonsignificantly increased (mean increase, 15.3 mL; P = .1616) with the dose-reduction platform. CONCLUSIONS: A significant reduction in patient radiation dose is achievable during neurovascular procedures by using dose-reduction technology with a minimal impact on workflow.
- Open Access
- 22 December 2016
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 38 (3) , 582-589
Surpass Flow Diverter for Treatment of Posterior Circulation Aneurysms
BACKGROUND AND PURPOSE: Flow diverters for the treatment of posterior circulation aneurysms remain controversial. We aimed to identify factors contributing to outcome measures in patients treated with the Surpass flow diverter for aneurysms in this location. MATERIALS AND METHODS: We conducted an observational study of 53 patients who underwent flow-diverter treatment for posterior circulation aneurysms at 15 centers. Key outcome measures were mortality, complete aneurysm occlusion, and modified Rankin Scale score at follow-up. RESULTS: At follow-up (median, 11.3 months; interquartile range, 5.9–12.7 months), 9 patients had died, resulting in an all-cause mortality rate of 17.3% (95% CI, 7%–27.6%); 7 deaths (14%) were directly related to the procedure and none occurred in patients with a baseline mRS score of zero. After adjusting for covariates, a baseline mRS of 3–5 was more significantly (P = .003) associated with a higher hazard ratio for death than a baseline mRS of 0–2 (hazard ratio, 17.11; 95% CI, 2.69–109.02). After adjusting for follow-up duration, a 1-point increase in the baseline mRS was significantly (P < .001) associated with higher values of mRS at follow-up (odds ratio, 2.93; 95% CI, 1.79–4.79). Follow-up angiography in 44 patients (median, 11.3 months; interquartile range, 5.9–12.7 months) showed complete aneurysm occlusion in 29 (66%; 95% CI, 50.1%–79.5%). CONCLUSIONS: Clinical results of flow-diverter treatment of posterior circulation aneurysms depend very much on patient selection. In this study, poorer outcomes were related to the treatment of aneurysms in patients with higher baseline mRS scores. Angiographic results showed a high occlusion rate for this subset of complex aneurysms.
- 22 December 2016
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 38 (3) , 582-589
Open AccessSurpass Flow Diverter for Treatment of Posterior Circulation Aneurysms
BACKGROUND AND PURPOSE: Flow diverters for the treatment of posterior circulation aneurysms remain controversial. We aimed to identify factors contributing to outcome measures in patients treated with the Surpass flow diverter for aneurysms in this location. MATERIALS AND METHODS: We conducted an observational study of 53 patients who underwent flow-diverter treatment for posterior circulation aneurysms at 15 centers. Key outcome measures were mortality, complete aneurysm occlusion, and modified Rankin Scale score at follow-up. RESULTS: At follow-up (median, 11.3 months; interquartile range, 5.9–12.7 months), 9 patients had died, resulting in an all-cause mortality rate of 17.3% (95% CI, 7%–27.6%); 7 deaths (14%) were directly related to the procedure and none occurred in patients with a baseline mRS score of zero. After adjusting for covariates, a baseline mRS of 3–5 was more significantly (P = .003) associated with a higher hazard ratio for death than a baseline mRS of 0–2 (hazard ratio, 17.11; 95% CI, 2.69–109.02). After adjusting for follow-up duration, a 1-point increase in the baseline mRS was significantly (P < .001) associated with higher values of mRS at follow-up (odds ratio, 2.93; 95% CI, 1.79–4.79). Follow-up angiography in 44 patients (median, 11.3 months; interquartile range, 5.9–12.7 months) showed complete aneurysm occlusion in 29 (66%; 95% CI, 50.1%–79.5%). CONCLUSIONS: Clinical results of flow-diverter treatment of posterior circulation aneurysms depend very much on patient selection. In this study, poorer outcomes were related to the treatment of aneurysms in patients with higher baseline mRS scores. Angiographic results showed a high occlusion rate for this subset of complex aneurysms.
- Open Access
- 10 November 2016
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 38 (1) , 97-104
Emergent Endovascular Management of Long-Segment and Flow-Limiting Carotid Artery Dissections in Acute Ischemic Stroke Intervention with Multiple Tandem Stents
BACKGROUND AND PURPOSE: Although most cervical dissections are managed medically, emergent endovascular treatment may become necessary in the presence of intracranial large-vessel occlusions, flow-limiting and long-segment dissections with impending occlusion, and/or hypoperfusion-related ischemia at risk of infarction. We investigated the role of emergent endovascular stenting of long-segment carotid dissections in the acute ischemic stroke setting. MATERIALS AND METHODS: We retrospectively studied long-segment carotid dissections requiring stent reconstruction with multiple tandem stents (≥3 stents) and presenting with acute (70% flow limiting stenosis and involved the distal cervical ICA with a minimum length of 3.5 cm. Carotid stent reconstruction was successful in all patients with no residual stenosis or flow limitation. Nine patients (60%) harbored intracranial occlusions, and 6 patients (40%) required intra-arterial thrombolysis/thrombectomy, achieving 100% TICI 2b–3 reperfusion. Two procedural complications were limited to thromboembolic infarcts from in-stent thrombus and asymptomatic hemorrhagic infarct transformation (7% morbidity, 0% mortality). Angiographic and ultrasound follow-up confirmed normal carotid caliber and stent patency, with 2 cases of <20% in-stent stenosis. Early clinical improvement resulted in a mean discharge NIHSS score of 6, and 9/15 (60%) patients achieved a 90-day mRS of ≤2. CONCLUSIONS: Emergent stent reconstruction of long-segment and flow-limiting carotid dissections in acute ischemic stroke intervention is safe and effective, with favorable clinical outcomes, allowing successful thrombectomy, vessel salvage, restoration of cerebral perfusion, and/or prevention of recurrent thromboembolic stroke.
- 10 November 2016
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 38 (1) , 97-104
Open AccessEmergent Endovascular Management of Long-Segment and Flow-Limiting Carotid Artery Dissections in Acute Ischemic Stroke Intervention with Multiple Tandem Stents
BACKGROUND AND PURPOSE: Although most cervical dissections are managed medically, emergent endovascular treatment may become necessary in the presence of intracranial large-vessel occlusions, flow-limiting and long-segment dissections with impending occlusion, and/or hypoperfusion-related ischemia at risk of infarction. We investigated the role of emergent endovascular stenting of long-segment carotid dissections in the acute ischemic stroke setting. MATERIALS AND METHODS: We retrospectively studied long-segment carotid dissections requiring stent reconstruction with multiple tandem stents (≥3 stents) and presenting with acute (70% flow limiting stenosis and involved the distal cervical ICA with a minimum length of 3.5 cm. Carotid stent reconstruction was successful in all patients with no residual stenosis or flow limitation. Nine patients (60%) harbored intracranial occlusions, and 6 patients (40%) required intra-arterial thrombolysis/thrombectomy, achieving 100% TICI 2b–3 reperfusion. Two procedural complications were limited to thromboembolic infarcts from in-stent thrombus and asymptomatic hemorrhagic infarct transformation (7% morbidity, 0% mortality). Angiographic and ultrasound follow-up confirmed normal carotid caliber and stent patency, with 2 cases of <20% in-stent stenosis. Early clinical improvement resulted in a mean discharge NIHSS score of 6, and 9/15 (60%) patients achieved a 90-day mRS of ≤2. CONCLUSIONS: Emergent stent reconstruction of long-segment and flow-limiting carotid dissections in acute ischemic stroke intervention is safe and effective, with favorable clinical outcomes, allowing successful thrombectomy, vessel salvage, restoration of cerebral perfusion, and/or prevention of recurrent thromboembolic stroke.
- 16 April 2015
- Published by S. Karger AG
- p. 1244-1247
Overpressure Digital Subtraction Cisternography and MR Cisternography in CSF Rhinorrhea
- 16 April 2015
- Published by S. Karger AG
- p. 1244-1247
Overpressure Digital Subtraction Cisternography and MR Cisternography in CSF Rhinorrhea
- 1 January 1994
- Published by Springer Nature
- p. 30-34
Local Intra-arterial Fibrinolytic Therapy in Vertebrobasilar Occlusion
- 1 January 1994
- Published by Springer Nature
- p. 30-34
Local Intra-arterial Fibrinolytic Therapy in Vertebrobasilar Occlusion