Ana Espinos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ana Espinos has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Manuel L. Romero
Instituto de Ciencia y Tecnología del Hormigón (ICITECH); Universitat Politècnica de València; Spain
31 shared publications - Antonio Hospitaler
Universidad Politécnica de Valencia
28 shared publications - Carmen Ibañez
Department of Mechanical Engineering and Construction Universitat Jaume I Castelló de la Plana (Spain)
14 shared publications - Vicente Albero
Department of Mechanical Engineering and Construction, Universitat Jaume I, 12071 Castellón de la Plana, Spain
13 shared publications - J.M. Portolés
Department of Mechanical Engineering and Construction, Universitat Jaume I, Castellón, Spain
4 shared publications M Romero
4 shared publications
Latest Publications
- Open Access
- 18 March 2026
- Published by Elsevier in Journal of Building Engineering
- Vol. 123
Eurocode-based design method to evaluate the plastic bending moment capacity of demountable steel-concrete composite beams in the fire situation
- 18 March 2026
- Published by Elsevier in Journal of Building Engineering
- Vol. 123
Open AccessEurocode-based design method to evaluate the plastic bending moment capacity of demountable steel-concrete composite beams in the fire situation
- Open Access
- 20 June 2023
- Published by Elsevier in Thin-Walled Structures
- Vol. 189
Experimental residual capacity of steel-reinforced concrete-filled steel tubular stub columns after fire exposure
- 20 June 2023
- Published by Elsevier in Thin-Walled Structures
- Vol. 189
Open AccessExperimental residual capacity of steel-reinforced concrete-filled steel tubular stub columns after fire exposure
- Open Access
- 22 May 2023
- Published by CINTER in Hormigón y Acero
- Vol. 74 (301) , 75-88
Estrategias de diseño para el cumplimiento de una resistencia al fuego R15 en estructuras industriales mediante el empleo del acero galvanizado
La resistencia al fuego de la estructura portante es una de las exigencias básicas que ha de ser verificada en toda obra de construcción. Estudios recientes han demostrado una ligera ventaja del acero galvanizado frente al acero al carbono en cuanto a lo que a resistencia al fuego se refiere. Este comportamiento más favorable del acero galvanizado se debe a su menor emisividad a temperaturas por debajo de los 500 ºC, lo que permite dotar a la estructura de una mejora inherente en términos de resistencia al fuego en el rango entre 15 y 30 minutos. En España, este rango de tiempos requeridos puede encontrarse fácilmente dentro del ámbito de la edificación industrial. En estos casos, es posible cumplir las exigencias de resistencia al fuego utilizando el acero galvanizado, evitando de esta forma tener que proteger la estructura mediante materiales de protección pasiva. En este artículo se pretende acercar al proyectista al cálculo de la resistencia al fuego de elementos estructurales de acero galvanizado, a través de la presentación de un ejemplo de cálculo guiado donde se compararán los beneficios que aporta el acero galvanizado frente al acero al carbono en este tipo de situaciones.
- 22 May 2023
- Published by CINTER in Hormigón y Acero
- Vol. 74 (301) , 75-88
Open AccessEstrategias de diseño para el cumplimiento de una resistencia al fuego R15 en estructuras industriales mediante el empleo del acero galvanizado
La resistencia al fuego de la estructura portante es una de las exigencias básicas que ha de ser verificada en toda obra de construcción. Estudios recientes han demostrado una ligera ventaja del acero galvanizado frente al acero al carbono en cuanto a lo que a resistencia al fuego se refiere. Este comportamiento más favorable del acero galvanizado se debe a su menor emisividad a temperaturas por debajo de los 500 ºC, lo que permite dotar a la estructura de una mejora inherente en términos de resistencia al fuego en el rango entre 15 y 30 minutos. En España, este rango de tiempos requeridos puede encontrarse fácilmente dentro del ámbito de la edificación industrial. En estos casos, es posible cumplir las exigencias de resistencia al fuego utilizando el acero galvanizado, evitando de esta forma tener que proteger la estructura mediante materiales de protección pasiva. En este artículo se pretende acercar al proyectista al cálculo de la resistencia al fuego de elementos estructurales de acero galvanizado, a través de la presentación de un ejemplo de cálculo guiado donde se compararán los beneficios que aporta el acero galvanizado frente al acero al carbono en este tipo de situaciones.
- 1 September 2020
- Published by Elsevier in Journal of Constructional Steel Research
- Vol. 172
Recent developments and fire design provisions for CFST columns and slim-floor beams
- 1 September 2020
- Published by Elsevier in Journal of Constructional Steel Research
- Vol. 172
Recent developments and fire design provisions for CFST columns and slim-floor beams
Fire design of slim‐floor beams
Slim‐floor beams are a well‐known and cost‐effective solution that permits a significant reduction of floor thickness, and are increasingly used in industrial and commercial buildings. Since only their lower flange is exposed to fire, slim‐floor beams may also achieve higher fire resistance, in comparison to other types of composite beams that are not fully embedded in the concrete floor. Simplified models are available in Eurocode 4 Parts 1‐2 to evaluate the temperature distribution for partially encased and non‐encased composite beams. However this standard does not provide any simplified model to evaluate the cross‐sectional temperature field of slim‐floor beams. In this sense, different proposals have been evaluated in recent years in order to provide simplified models for temperature evaluation. The currently available models in the literature have shown their accurate behaviour providing results on the safe side, and are recommended for use in practice. Finally, this work shows that slim‐floor composite beams can provide good performance during a fire event. Specifically, 60 min of standard fire rating can be achieved for load levels lower than 0.5–0.6. Improved behaviour to achieve 90 or 120 min of standard fire exposure may also be reached by using innovative solutions, advanced materials or external protection.
Fire design of slim‐floor beams
Slim‐floor beams are a well‐known and cost‐effective solution that permits a significant reduction of floor thickness, and are increasingly used in industrial and commercial buildings. Since only their lower flange is exposed to fire, slim‐floor beams may also achieve higher fire resistance, in comparison to other types of composite beams that are not fully embedded in the concrete floor. Simplified models are available in Eurocode 4 Parts 1‐2 to evaluate the temperature distribution for partially encased and non‐encased composite beams. However this standard does not provide any simplified model to evaluate the cross‐sectional temperature field of slim‐floor beams. In this sense, different proposals have been evaluated in recent years in order to provide simplified models for temperature evaluation. The currently available models in the literature have shown their accurate behaviour providing results on the safe side, and are recommended for use in practice. Finally, this work shows that slim‐floor composite beams can provide good performance during a fire event. Specifically, 60 min of standard fire rating can be achieved for load levels lower than 0.5–0.6. Improved behaviour to achieve 90 or 120 min of standard fire exposure may also be reached by using innovative solutions, advanced materials or external protection.
- 1 February 2019
- Published by Elsevier in Engineering Structures
- Vol. 180, 561-573
Numerical study on the flexural behaviour of slim-floor beams with hollow core slabs at elevated temperature
- 1 February 2019
- Published by Elsevier in Engineering Structures
- Vol. 180, 561-573
Numerical study on the flexural behaviour of slim-floor beams with hollow core slabs at elevated temperature
- 1 September 2018
- Published by Elsevier in Thin-Walled Structures
- Vol. 130, 641-651
Interaction diagram based method for fire resistance design of eccentrically loaded concrete-filled steel tubular columns
- 1 September 2018
- Published by Elsevier in Thin-Walled Structures
- Vol. 130, 641-651
Interaction diagram based method for fire resistance design of eccentrically loaded concrete-filled steel tubular columns
- 1 November 2017
- Published by Elsevier in Structures
- Vol. 12, 64-74
Ultra-high Strength Concrete on Eccentrically Loaded Slender Circular Concrete-filled Dual Steel Columns
- 1 November 2017
- Published by Elsevier in Structures
- Vol. 12, 64-74
Ultra-high Strength Concrete on Eccentrically Loaded Slender Circular Concrete-filled Dual Steel Columns