Manuel L. Romero
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Manuel L. Romero has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
- Ana Espinos
Instituto de Ciencia y Tecnología del Hormigón (ICITECH); Universitat Politècnica de València; Spain
31 shared publications - Antonio Hospitaler
Universidad Politécnica de Valencia
28 shared publications - José Luis Bonet
ICITECH Universitat Politècnica de València Valencia Spain
23 shared publications - Carmen Ibañez
Department of Mechanical Engineering and Construction Universitat Jaume I Castelló de la Plana (Spain)
13 shared publications - Vicente Albero
Department of Mechanical Engineering and Construction, Universitat Jaume I, 12071 Castellón de la Plana, Spain
13 shared publications P.F. Miguel
10 shared publications
Latest Publications
- Open Access
- 18 March 2026
- Published by Elsevier in Journal of Building Engineering
- Vol. 123
Eurocode-based design method to evaluate the plastic bending moment capacity of demountable steel-concrete composite beams in the fire situation
- 18 March 2026
- Published by Elsevier in Journal of Building Engineering
- Vol. 123
Open AccessEurocode-based design method to evaluate the plastic bending moment capacity of demountable steel-concrete composite beams in the fire situation
- Open Access
- 15 July 2025
- Published by Elsevier in Thin-Walled Structures
- Vol. 216
Effect of combined high temperature and tensile load on the post-fire performance of high-strength steel
- 15 July 2025
- Published by Elsevier in Thin-Walled Structures
- Vol. 216
Open AccessEffect of combined high temperature and tensile load on the post-fire performance of high-strength steel
- 1 October 2019
- Published by Elsevier in Structures
- Vol. 21, 90-102
Post-heating response of concrete-filled steel tubular columns under sustained loads
- 1 October 2019
- Published by Elsevier in Structures
- Vol. 21, 90-102
Post-heating response of concrete-filled steel tubular columns under sustained loads
Fire design of slim‐floor beams
Slim‐floor beams are a well‐known and cost‐effective solution that permits a significant reduction of floor thickness, and are increasingly used in industrial and commercial buildings. Since only their lower flange is exposed to fire, slim‐floor beams may also achieve higher fire resistance, in comparison to other types of composite beams that are not fully embedded in the concrete floor. Simplified models are available in Eurocode 4 Parts 1‐2 to evaluate the temperature distribution for partially encased and non‐encased composite beams. However this standard does not provide any simplified model to evaluate the cross‐sectional temperature field of slim‐floor beams. In this sense, different proposals have been evaluated in recent years in order to provide simplified models for temperature evaluation. The currently available models in the literature have shown their accurate behaviour providing results on the safe side, and are recommended for use in practice. Finally, this work shows that slim‐floor composite beams can provide good performance during a fire event. Specifically, 60 min of standard fire rating can be achieved for load levels lower than 0.5–0.6. Improved behaviour to achieve 90 or 120 min of standard fire exposure may also be reached by using innovative solutions, advanced materials or external protection.
Fire design of slim‐floor beams
Slim‐floor beams are a well‐known and cost‐effective solution that permits a significant reduction of floor thickness, and are increasingly used in industrial and commercial buildings. Since only their lower flange is exposed to fire, slim‐floor beams may also achieve higher fire resistance, in comparison to other types of composite beams that are not fully embedded in the concrete floor. Simplified models are available in Eurocode 4 Parts 1‐2 to evaluate the temperature distribution for partially encased and non‐encased composite beams. However this standard does not provide any simplified model to evaluate the cross‐sectional temperature field of slim‐floor beams. In this sense, different proposals have been evaluated in recent years in order to provide simplified models for temperature evaluation. The currently available models in the literature have shown their accurate behaviour providing results on the safe side, and are recommended for use in practice. Finally, this work shows that slim‐floor composite beams can provide good performance during a fire event. Specifically, 60 min of standard fire rating can be achieved for load levels lower than 0.5–0.6. Improved behaviour to achieve 90 or 120 min of standard fire exposure may also be reached by using innovative solutions, advanced materials or external protection.
- 1 February 2019
- Published by Elsevier in Engineering Structures
- Vol. 180, 561-573
Numerical study on the flexural behaviour of slim-floor beams with hollow core slabs at elevated temperature
- 1 February 2019
- Published by Elsevier in Engineering Structures
- Vol. 180, 561-573
Numerical study on the flexural behaviour of slim-floor beams with hollow core slabs at elevated temperature
- 1 September 2018
- Published by Elsevier in Thin-Walled Structures
- Vol. 130, 641-651
Interaction diagram based method for fire resistance design of eccentrically loaded concrete-filled steel tubular columns
- 1 September 2018
- Published by Elsevier in Thin-Walled Structures
- Vol. 130, 641-651
Interaction diagram based method for fire resistance design of eccentrically loaded concrete-filled steel tubular columns
- 1 August 2018
- Published by Elsevier in Advances in Engineering Software
- Vol. 122, 81-92
Optimal design of prestressed concrete hollow core slabs taking into account its fire resistance
- 1 August 2018
- Published by Elsevier in Advances in Engineering Software
- Vol. 122, 81-92
Optimal design of prestressed concrete hollow core slabs taking into account its fire resistance
- 13 November 2017
- Published by Taylor & Francis
- p. 311-316
Eurocode 4 based method for the fire design of concrete-filled steel tubular columns
The unsafety of the current design guidelines in Annex H of EN 1994-1-2 for the calculation of the fire resistance of slender Concrete-Filled Steel Tubular (CFST) columns was highlighted in previous investigations, which led to an addenda approved by CEN/TC250/SC4 limiting its application to columns of a maximum 0.5 relative slenderness. As one of the outcomes from the recently concluded RFCS European Project FRISCC, a simplified design method for the fire resistance of CFST columns was developed, covering all the practical range of application of CFST columns and including different cross-section shapes. The method is applicable to both axially and eccentrically loaded columns, accounting for minor and major axis eccentricities and considering the possibility of loads applied out of the section. Bending moment—axial force interaction curves specially built up for the fire situation are proposed for eccentric loads, being in line with the method in EN1994-1-1 for cold design.
- 13 November 2017
- Published by Taylor & Francis
- p. 311-316
Eurocode 4 based method for the fire design of concrete-filled steel tubular columns
The unsafety of the current design guidelines in Annex H of EN 1994-1-2 for the calculation of the fire resistance of slender Concrete-Filled Steel Tubular (CFST) columns was highlighted in previous investigations, which led to an addenda approved by CEN/TC250/SC4 limiting its application to columns of a maximum 0.5 relative slenderness. As one of the outcomes from the recently concluded RFCS European Project FRISCC, a simplified design method for the fire resistance of CFST columns was developed, covering all the practical range of application of CFST columns and including different cross-section shapes. The method is applicable to both axially and eccentrically loaded columns, accounting for minor and major axis eccentricities and considering the possibility of loads applied out of the section. Bending moment—axial force interaction curves specially built up for the fire situation are proposed for eccentric loads, being in line with the method in EN1994-1-1 for cold design.
- 13 November 2017
- Published by Taylor & Francis
- p. 317-322
Thermal behavior of connections between concrete-filled steel tubular columns and slim-floors subjected to fire
Both Concrete-Filled Steel Tubular columns (CFST) and composite steel-concrete beams embedded in floors (slim-floors) are being increasingly used in new construction proposals. The fire performance of these structural elements has been studied in recent years separately. Nevertheless, understanding the fire behavior of the connections between both elements may be an important issue in the global structural response of these composite solutions. In this work, an advanced finite element thermal model is developed to assess the behavior of these connections in the fire situation. The embedment of the connection into the slim-floor is studied, which provides a thermal protection to the blind-bolt. The thermal behavior of this slim-floor connection was compared against non-encased beams, reaching 600ºC difference in the lower bolt at 60 minutes of fire exposure. It shows that the bolt temperature into the slim-floor, which is lower than 200ºC, would have little effect on the connection structural resistance.
- 13 November 2017
- Published by Taylor & Francis
- p. 317-322
Thermal behavior of connections between concrete-filled steel tubular columns and slim-floors subjected to fire
Both Concrete-Filled Steel Tubular columns (CFST) and composite steel-concrete beams embedded in floors (slim-floors) are being increasingly used in new construction proposals. The fire performance of these structural elements has been studied in recent years separately. Nevertheless, understanding the fire behavior of the connections between both elements may be an important issue in the global structural response of these composite solutions. In this work, an advanced finite element thermal model is developed to assess the behavior of these connections in the fire situation. The embedment of the connection into the slim-floor is studied, which provides a thermal protection to the blind-bolt. The thermal behavior of this slim-floor connection was compared against non-encased beams, reaching 600ºC difference in the lower bolt at 60 minutes of fire exposure. It shows that the bolt temperature into the slim-floor, which is lower than 200ºC, would have little effect on the connection structural resistance.