ASAhmed Soltan

Ahmed Soltan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ahmed Soltan has a total of 151 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimizing Parameter Selection for Forecasting and Classifying Water Quality

    by Salma Zakzouk, Mohamed Medhat, Lobna Said, Ahmed Soltan

    Effective water quality monitoring systems are essential for environmental management and public health; however, traditional monitoring methods can be inefficient, costly, and resource-intensive. This work examined India and Hong Kong as case studies, focusing on optimizing water quality parameters for improved system performance while reducing costs and power consumption. Through preprocessing techniques, including correlation matrix analysis, sensitivity analysis, and ANOVA, the initial set of seven water quality parameters was reduced to four: DO, pH, BOD, and Fecal Coliform. To overcome limitations in conventional assessment methods, deep learning models were employed to enhance water quality forecasting and classification. LSTM was used to forecast WQI values, achieving a RMSE of 0.2498. Meanwhile, CNN classified water with 97.20% accuracy, while also forecasting the selected water quality parameters. This work contributes to the field by demonstrating a lightweight, low-power deep learning approach that achieves comparable or superior performance using fewer parameters, making it suitable for real-time water monitoring in resource-limited environments.

  • 100x Longevity Improvement of Optoelectronic Implants Through Balancing Integral Electric Fields

    by Reza Ramezani, Ahmed Soltan, Peimin Yuan, Dimitris Firfilionis, Nick Donaldson, Patrick Degenaar

    Photonics and Optoelectronics are becoming increasingly important for use in implantable devices. In animal trials, although not desirable, failure can lead to the direct replacement of either the component or the test subject. In human implementations, however, the longevity of implantable devices typically needs to exceed 5 years and, in some cases, decades. Traditional hermetic metal packages, per definition, are impervious to water vapour. However, such packaging is unsuitable for structures which are millimetre sized or less. Brain probes encompassing optical micro-emitters must, therefore, use protective passivation/encapsulation layers such as silicon oxynitrides/silicone. However, such protection is prone to electrolytic failure driven by the LED-driving voltages. In this paper, we describe an electrical driving methodology which can improve device lifetime of encapsulated devices by balancing time-averaged electric fields to zero. We have tested the method on commercial optrodes to demonstrate platform independence. We show that, with this method, the time to failure can be increased by over two orders of magnitude.

  • Toward Precision Health: A Bluetooth-Enabled, Miniaturized Glucose Monitoring Wearable

    by Mohammad Mansour, Samar H. Tawakey, Alyaa I. Salim, Sayed T. Muhammad, Ahmed Soltan

    In this work, a miniaturized, Bluetooth-enabled glucose monitoring wearable patch is proposed. The device integrates improved potentiostatic systems and microneedle technology to enable minimally-invasive, real-time monitoring of glucose levels. For the microneedle auto-calibration, an automatic glucose oxidation peak detector algorithm is implemented within the microcontroller for more stablity in glucose measurements. The calibrarion procees also reduces the operation time during chronoamperometric measurements. The device’s functionality is extended beyond continuously monitoring glucose in the interstitial fluid by integrating off-the-shelf sensors for heart rate and body temperature monitoring. The integration of these sensors and the wireless communication protocol is managed to ensure seamless operation, minimal power consumption, and user comfort. The device operates using a dedicated cross-platform application to collect and display data. The sensitivity of the glucose sensor is 30.44 nA/mM, covering a dynamic range of 1.5−14 mM. Through a detailed examination of power management strategies and sensor data integrity, this study demonstrates the feasibility of such integrated health monitoring devices for everyday use. With ultra-low power consumption of 103 μW, the device has an extended battery life of 204 days by using a smart energy management technique. Moreover, the microneedle sensor offers a long lifespan of 15 days before needing replacement. The device has potential utility in personalized healthcare and clinical settings.


  • Open Access

    Optogenetic Multiphysical Fields Coupling Model for Implantable Neuroprosthetic Probes

    by Na Dong, Emily Johnson, Rolando Berlinguer-Palmini, Hongze Zhong, Fahimeh Dehkhoda, Ahmed Soltan, Konstantin Nikolic, Nir Grossman, Johannes Gausden, Richard Bailey, et al.

    Optogenetic-based neuroprosthetic therapies are increasingly being considered for human trials. However, the optoelectronic design of clinical-grade optogenetic-based neuroprosthetic probes still requires some thought. Design constraints include light penetration into the brain, stimulation efficacy, and probe/tissue heating. Optimisation can be achieved through experimental iteration. However, this is costly, time-consuming and ethically problematic. Hence it is highly desirable to have an alternative to excessive animal trials. Thus, a simulation tool for optimising probe design can be an important benefit for the community. The challenge is to understand the interplay between the optical, neural and thermal aspects in the interaction of probe and living neural tissue. In this work, we propose a model which combines these aspects to allow clinically orientated neuroprosthetic teams to design neuroprosthetic probes for optogenetic therapies. Our model provides analyses for optical, thermal and optogenetic electrophysiological processes based on the energy equivalence and exchange among different physical fields. To validate and calibrate the model, optogenetic implantable neuroprosthetic arrayed probes based on miniature LEDs were developed. Then, optical, thermal measurement and neural photocurrent recording experiments were implemented on the probes. We can then provide analysis on exemplar arrayed neural probes.


  • Top Cited Papers
    Open Access

    Wearable devices for glucose monitoring: A review of state-of-the-art technologies and emerging trends

    by Mohammad Mansour, M. Saeed Darweesh, Ahmed Soltan


  • Hardware Accelerator of Fractional-Order Operator Based on Phase Optimized Filters With Applications

    by Alaa AbdAlRahman, Lobna A. Said, Ahmed Soltan, Ahmed G. Radwan

    Hardware accelerators outperform CPUs in terms of performance by parallelizing the algorithm architecture and using the device’s programmable resources. FPGA is a type of hardware accelerator that excels not only in performance but also in energy efficiency. So, it provides a suitable platform for implementing complicated fractional-order systems. This paper proposes a novel phase-based optimization method to implement fractional operators using FIR and IIR filters. We also compare five fractional operator implementation methods on FPGA regarding resource utilization, execution time, power, and accuracy. These methods and the proposed one are evaluated in terms of power consumption, delay, and resources to assist the designer in determining the most suitable implementation method for the given application. The proposed method has a lower phase error of $14.7\%$ in the case of derivative operation and a lower phase error of $18.83\%$ in the case of integration compared to the literature. In addition, the proposed methods decreased the consumed power and area by more than three times compared to the fixed-window GL fractional operator. The proposed approach implements Heaviside’s inductor-terminated lossy line. In addition, it is employed as an edge detection kernel to demonstrate its effectiveness in image processing applications.


  • Open Access

    A comparative study of predicting the availability of power line communication nodes using machine learning

    by Kareem Moussa, Mennatullah Mahmoud Amin, M. Saeed Darweesh, Lobna A. Said, Abdelmoniem Elbaz, Ahmed Soltan

    Power Line Communication technology uses power cables to transmit data. Knowing whether a node is working in advance without testing saves time and resources, leading to the proposed model. The model has been trained on three dominant features, which are SNR (Signal to Noise Ratio), RSSI (Received Signal Strength Indicator), and CINR (Carrier to Interference plus Noise Ratio). The dataset consisted of 1000 readings, with 90% in the training set and 10% in the testing set. In addition, 50% of the dataset is for class 1, which indicates whether the node readings are optimum. The model is trained with multi-layer perception, K-Nearest Neighbors, Support Vector Machine with linear and non-linear kernels, Random Forest, and adaptive boosting (ADA) algorithms to compare between statistical, vector-based, regression, decision, and predictive algorithms. ADA boost has achieved the best accuracy, F-score, precision, and recall, which are 87%, 0.86613, 0.9, 0.8646, respectively.


  • Open Access

    Energy management for wearable medical devices based on gaining–sharing knowledge algorithm

    by Samah Mohamed, Hazem A. A. Nomer, Retaj Yousri, Ali Wagdy Mohamed, Ahmed Soltan, M. Saeed Darweesh

    Wearable devices are a growing field of research that can have a wide range of applications. The energy harvester is the most common source of power for wearable devices as well as in wireless sensor networks that require a battery-free operation. However, their power is restricted; consequently, power saving is crucial for wearable devices. Finding the best schedule for the various tasks that run on the wearable device can help to reduce power consumption. This paper presents a task scheduler for wearable medical devices based on Gaining–Sharing Knowledge (GSK) algorithm. The purpose of this task scheduler is to handle the tasks of a heart rate sensor and a temperature sensor to optimize the energy consumption throughout wearable medical devices. The proposed GSK-based scheduling algorithm is assessed against the state-of-the-art technique. The data used in our experiments are collected from an in-lab prototype.