ELErnest W. Lau

Ernest W. Lau

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ernest W. Lau has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Antimicrobial Efficacy of a Taurolidine‐Based Antimicrobial Compound on Contaminated Surfaces Simulated in a Standardized 4‐Field Test

    by Benito Baldauf, Hendrik Bonnemeier, Ernest W. Lau, Jana Hummel, Reinhard Vonthein, Ojan Assadian

    Implantable medical devices, including cardiac electronic implants, joint prostheses, and breast implants, are essential to modern healthcare but remain susceptible to infection from microbial contamination during placement. Staphylococcus spp . and Candida albicans are the predominant pathogens, often causing severe complications, increased mortality, and substantial healthcare costs. With antibiotic resistance on the rise, intraoperative surface disinfection has emerged as a critical yet underutilized preventive strategy. Taurolidine, a broad‐spectrum antimicrobial with a strong safety profile and no known resistance, can be applied directly to both tissues and device surfaces. To replicate intraoperative decontamination, taurolidine‐saturated swabs are tested under standardized mechanical wiping using the European Norm EN 16615 “4‐field test.” The model reproduced short contact times and organic load conditions reflective of clinical practice, enabling assessment of both chemical and mechanical antimicrobial effects. Taurolidine achieved >5 log 10 reductions in Staphylococcus aureus , Pseudomonas aeruginosa , and Candida albicans , and >4 log 10 for Enterococcus hirae . The observed activity demonstrated a surface‐driven, enzyme‐independent mechanism involving spontaneous release of reactive N‐methylol functional groups that disrupt microbial membranes. Taurolidine's enzyme‐independent antimicrobial mechanism distinguishes it from solvent‐ or oxidant‐based disinfectants. These results support taurolidine as a potential adjunctive prophylactic agent to reduce device‐related infections during implantation procedures.


  • Open Access

    The European TauroPace™ Registry

    by Reinhard Vonthein, Benito Baldauf, Stefan Borov, Ernest W. Lau, Marzia Giaccardi, Roberto Cemin, Ojan Assadian, Philippe Chévalier, Kerstin Bode, Hendrik Bonnemeier

    Background: Cardiac implantable electronic device (CIED) placement comes with certain complications. CIED infection is a severe adverse event related to CIED placement. In randomised controlled trials, the preoperative intravenous administration of antibiotics and the adjunctive use of an antibiotic mesh envelope resulted in significant reduction in infections related to cardiac implantable electronic devices. The adjunctive use of taurolidine for this purpose is relatively novel and not considered in the guidelines. The required evidence may consist of a set of clinical studies. Methods: The European TauroPaceTM registry (ETPR) prospectively evaluates every consecutive invasive procedure involving any CIED with adjunct TauroPace™ use in the contributing centres. As the estimation of the infection rate needs to be defensible, only interventions registered prior to the procedure will be followed-up. The endpoint is a major cardiac implantable electronic device infection according to the novel CIED infection criteria (1). Secondary endpoints comprise all-cause mortality, complications, adverse events of all grades, and major CIED infections during all follow-up examinations. The follow-up times are three months, twelve months, and eventually 36 months, as acute, subacute, and long-term CIED infections are of interest. Results: As the rate of CIED infections is expected to be very low, this registry is a multicentre, international project that will run for several years. Several reports are planned. The analyses will be included in the case number calculations for future randomised controlled trials. Conclusions: The ETPR will accumulate large case numbers to estimate small event rates more precisely; we intend to follow up on participants for years to reveal possible late effects.


  • Open Access

    Salvage of Cardiac Implantable Electronic Device Pocket Infection with Skin Erosion in Frail 92-Year-Old

    by Marzia Giaccardi, Benito Baldauf, Ernest W. Lau, Stefan Borov, Hendrik Bonnemeier

    We reported the novel use of a taurolidine-containing antimicrobial solution in the successful salvage of a partially exposed and polymicrobially infected cardiac implantable electronic device pulse generator in a frail patient unfit for lead extraction. The old, salvaged device was entirely internalized, and there were no signs of recurrent infection at 9 months follow-up.


  • Open Access

    Eradication of Ventricular Assist Device Driveline Infection in Paediatric Patients with Taurolidine

    by Johannes Weichsel, Benito Baldauf, Hendrik Bonnemeier, Ernest W. Lau, Sven Dittrich, Robert Cesnjevar

    Ventricular assist devices (VADs) are used to provide mechanical circulatory support to patients with end-stage heart failure. The driveline connecting the external power source to the pump(s) of the intra-corporal VAD breaches the protective skin barrier and provides a track for microbes to invade the interior of the patient’s body. Driveline infection constitutes a major and potentially fatal vulnerability of VAD therapy. Driveline infection cannot traditionally be salvaged and requires the extraction of the entire VAD system. We report here the successful eradication of a VAD driveline infection with a taurolidine-containing antimicrobial solution used for preventing the infection of cardiac implantable electronic devices. If replicated in more cases, the novel treatment concept described here may provide a valuable alternative management strategy of salvage rather than explantation for VAD driveline infection.


  • Open Access

    Longevity decoded: Insights from power consumption analyses into device construction and their clinical implications

    by Ernest W. Lau

    Introduction: The longevity of a cardiac implantable electronic device (CIED) depends on how quickly the powers consumed by the device's functions exhaust its usable battery energy. A mathematical model for CIED power consumptions was developed and validated against longevity data from manufacturers.Methods: The programmable parameters for the Resonate X4 cardiac resynchronization therapy defibrillators (CRT‐Ds) on the Boston Scientific (St. Paul, MN, USA) online longevity calculator were designated as independent terms in the sum for the total power consumption. The reciprocal of longevity was plotted against variations in these terms. Linear and nonlinear regression analyses were used to fit the plots. The power consumed by pacing was theoretically derived and used as the calibrating tool for estimating the powers consumed by other functions and the usable battery energy. The same methodology was applied to the longevity data of other manufacturers’ CRT‐Ds.Results: Single chamber 100% pacing at 60 beats/min, 2.5 V, 0.4 ms, 500 Ω consumes ≈ 144 J/year. Shock therapy is 45–85% energy efficient. Multichamber pacing modes and maintaining readiness to pace a chamber consume power even if no pacing is delivered. Switching voltage regulation is theoretically more energy efficient than linear voltage regulation for powering pacing.Conclusions: The powers consumed by therapy functions are dictated by the patient's clinical needs, but healthcare professionals can extend device longevity by switching off dormant functions and simplifying the pacing mode. Choosing a device model with large usable battery energy, low background power, and energy efficient pacing and shock therapy for implantation will increase the probability of a long service lifespan.


  • Technologies for Prolonging Cardiac Implantable Electronic Device Longevity

    by Ernest W. Lau

    Prolonged longevity of cardiac implantable electronic devices (CIEDs) is needed not only as a passive response to match the prolonging life expectancy of patient recipients, but will also actively prolong their life expectancy by avoiding/deferring the risks (and costs) associated with device replacement. CIEDs are still exclusively powered by nonrechargeable primary batteries, and energy exhaustion is the dominant and an inevitable cause of device replacement. The longevity of a CIED is thus determined by the attrition rate of its finite energy reserve. The energy available from a battery depends on its capacity (total amount of electric charge), chemistry (anode, cathode, and electrolyte), and internal architecture (stacked plate, folded plate, and spiral wound). The energy uses of a CIED vary and include a background current for running electronic circuitry, periodic radiofrequency telemetry, high‐voltage capacitor reformation, constant ventricular pacing, and sporadic shocks for the cardiac resynchronization therapy defibrillators. The energy use by a CIED is primarily determined by the patient recipient's clinical needs, but the energy stored in the device battery is entirely under the manufacturer's control. A larger battery capacity generally results in a longer‐lasting device, but improved battery chemistry and architecture may allow more space‐efficient designs. Armed with the necessary technical knowledge, healthcare professionals and purchasers will be empowered to make judicious selection on device models and maximize the utilization of all their energy‐saving features, to prolong device longevity for the benefits of their patients and healthcare systems.


    • 1 September 2016
      • Vol. 85  (3) , 193-195

    Radial Multi-Site, Longitudinal Multi-Polar Epicardial Left Ventricular Pacing In Tricuspid Valve Disease

    by Ernest W Lau, Tony McEntee, Kyle B Ashfield, Alastair N Graham