Ernest W. Lau
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ernest W. Lau has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Benito Baldauf
University of Applied Sciences, Bremerhaven, Germany
4 shared publications - David Hugh Birnie
University of Ottawa Heart Institute, Ottawa, Ontario, Canada
2 shared publications - Hendrik Bonnemeier
Christian Albrechts University Kiel, Department of Electrophysiology, Kiel, Germany
2 shared publications - Marzia Giaccardi
Department of Cardiology, Santa Maria Annunziata Hospital, 50012 Florence, Italy
2 shared publications - Ojan Assadian
Institute for Skin Integrity, University of Huddersfield, Queensgate, Huddersfield HD1 3DH, UK
2 shared publications - Reinhard Vonthein
University of Luebeck, Luebeck, Germany
2 shared publications
Latest Publications
- Open Access
- 12 November 2025
- Published by Wiley in Advanced Healthcare Materials
- Vol. 15 (7) , e03479
Antimicrobial Efficacy of a Taurolidine‐Based Antimicrobial Compound on Contaminated Surfaces Simulated in a Standardized 4‐Field Test
Implantable medical devices, including cardiac electronic implants, joint prostheses, and breast implants, are essential to modern healthcare but remain susceptible to infection from microbial contamination during placement. Staphylococcus spp . and Candida albicans are the predominant pathogens, often causing severe complications, increased mortality, and substantial healthcare costs. With antibiotic resistance on the rise, intraoperative surface disinfection has emerged as a critical yet underutilized preventive strategy. Taurolidine, a broad‐spectrum antimicrobial with a strong safety profile and no known resistance, can be applied directly to both tissues and device surfaces. To replicate intraoperative decontamination, taurolidine‐saturated swabs are tested under standardized mechanical wiping using the European Norm EN 16615 “4‐field test.” The model reproduced short contact times and organic load conditions reflective of clinical practice, enabling assessment of both chemical and mechanical antimicrobial effects. Taurolidine achieved >5 log 10 reductions in Staphylococcus aureus , Pseudomonas aeruginosa , and Candida albicans , and >4 log 10 for Enterococcus hirae . The observed activity demonstrated a surface‐driven, enzyme‐independent mechanism involving spontaneous release of reactive N‐methylol functional groups that disrupt microbial membranes. Taurolidine's enzyme‐independent antimicrobial mechanism distinguishes it from solvent‐ or oxidant‐based disinfectants. These results support taurolidine as a potential adjunctive prophylactic agent to reduce device‐related infections during implantation procedures.
- 12 November 2025
- Published by Wiley in Advanced Healthcare Materials
- Vol. 15 (7) , e03479
Open AccessAntimicrobial Efficacy of a Taurolidine‐Based Antimicrobial Compound on Contaminated Surfaces Simulated in a Standardized 4‐Field Test
Implantable medical devices, including cardiac electronic implants, joint prostheses, and breast implants, are essential to modern healthcare but remain susceptible to infection from microbial contamination during placement. Staphylococcus spp . and Candida albicans are the predominant pathogens, often causing severe complications, increased mortality, and substantial healthcare costs. With antibiotic resistance on the rise, intraoperative surface disinfection has emerged as a critical yet underutilized preventive strategy. Taurolidine, a broad‐spectrum antimicrobial with a strong safety profile and no known resistance, can be applied directly to both tissues and device surfaces. To replicate intraoperative decontamination, taurolidine‐saturated swabs are tested under standardized mechanical wiping using the European Norm EN 16615 “4‐field test.” The model reproduced short contact times and organic load conditions reflective of clinical practice, enabling assessment of both chemical and mechanical antimicrobial effects. Taurolidine achieved >5 log 10 reductions in Staphylococcus aureus , Pseudomonas aeruginosa , and Candida albicans , and >4 log 10 for Enterococcus hirae . The observed activity demonstrated a surface‐driven, enzyme‐independent mechanism involving spontaneous release of reactive N‐methylol functional groups that disrupt microbial membranes. Taurolidine's enzyme‐independent antimicrobial mechanism distinguishes it from solvent‐ or oxidant‐based disinfectants. These results support taurolidine as a potential adjunctive prophylactic agent to reduce device‐related infections during implantation procedures.
- Open Access
- 15 September 2023
- Published by MDPI AG in Methods and Protocols
- Vol. 6 (5) , 86
The European TauroPace™ Registry
Background: Cardiac implantable electronic device (CIED) placement comes with certain complications. CIED infection is a severe adverse event related to CIED placement. In randomised controlled trials, the preoperative intravenous administration of antibiotics and the adjunctive use of an antibiotic mesh envelope resulted in significant reduction in infections related to cardiac implantable electronic devices. The adjunctive use of taurolidine for this purpose is relatively novel and not considered in the guidelines. The required evidence may consist of a set of clinical studies. Methods: The European TauroPaceTM registry (ETPR) prospectively evaluates every consecutive invasive procedure involving any CIED with adjunct TauroPace™ use in the contributing centres. As the estimation of the infection rate needs to be defensible, only interventions registered prior to the procedure will be followed-up. The endpoint is a major cardiac implantable electronic device infection according to the novel CIED infection criteria (1). Secondary endpoints comprise all-cause mortality, complications, adverse events of all grades, and major CIED infections during all follow-up examinations. The follow-up times are three months, twelve months, and eventually 36 months, as acute, subacute, and long-term CIED infections are of interest. Results: As the rate of CIED infections is expected to be very low, this registry is a multicentre, international project that will run for several years. Several reports are planned. The analyses will be included in the case number calculations for future randomised controlled trials. Conclusions: The ETPR will accumulate large case numbers to estimate small event rates more precisely; we intend to follow up on participants for years to reveal possible late effects.
- 15 September 2023
- Published by MDPI AG in Methods and Protocols
- Vol. 6 (5) , 86
Open AccessThe European TauroPace™ Registry
Background: Cardiac implantable electronic device (CIED) placement comes with certain complications. CIED infection is a severe adverse event related to CIED placement. In randomised controlled trials, the preoperative intravenous administration of antibiotics and the adjunctive use of an antibiotic mesh envelope resulted in significant reduction in infections related to cardiac implantable electronic devices. The adjunctive use of taurolidine for this purpose is relatively novel and not considered in the guidelines. The required evidence may consist of a set of clinical studies. Methods: The European TauroPaceTM registry (ETPR) prospectively evaluates every consecutive invasive procedure involving any CIED with adjunct TauroPace™ use in the contributing centres. As the estimation of the infection rate needs to be defensible, only interventions registered prior to the procedure will be followed-up. The endpoint is a major cardiac implantable electronic device infection according to the novel CIED infection criteria (1). Secondary endpoints comprise all-cause mortality, complications, adverse events of all grades, and major CIED infections during all follow-up examinations. The follow-up times are three months, twelve months, and eventually 36 months, as acute, subacute, and long-term CIED infections are of interest. Results: As the rate of CIED infections is expected to be very low, this registry is a multicentre, international project that will run for several years. Several reports are planned. The analyses will be included in the case number calculations for future randomised controlled trials. Conclusions: The ETPR will accumulate large case numbers to estimate small event rates more precisely; we intend to follow up on participants for years to reveal possible late effects.
- Open Access
- 10 March 2022
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 9 (3) , 81
Salvage of Cardiac Implantable Electronic Device Pocket Infection with Skin Erosion in Frail 92-Year-Old
We reported the novel use of a taurolidine-containing antimicrobial solution in the successful salvage of a partially exposed and polymicrobially infected cardiac implantable electronic device pulse generator in a frail patient unfit for lead extraction. The old, salvaged device was entirely internalized, and there were no signs of recurrent infection at 9 months follow-up.
- 10 March 2022
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 9 (3) , 81
Open AccessSalvage of Cardiac Implantable Electronic Device Pocket Infection with Skin Erosion in Frail 92-Year-Old
We reported the novel use of a taurolidine-containing antimicrobial solution in the successful salvage of a partially exposed and polymicrobially infected cardiac implantable electronic device pulse generator in a frail patient unfit for lead extraction. The old, salvaged device was entirely internalized, and there were no signs of recurrent infection at 9 months follow-up.
- Open Access
- 10 January 2022
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 9 (1) , 18
Eradication of Ventricular Assist Device Driveline Infection in Paediatric Patients with Taurolidine
Ventricular assist devices (VADs) are used to provide mechanical circulatory support to patients with end-stage heart failure. The driveline connecting the external power source to the pump(s) of the intra-corporal VAD breaches the protective skin barrier and provides a track for microbes to invade the interior of the patient’s body. Driveline infection constitutes a major and potentially fatal vulnerability of VAD therapy. Driveline infection cannot traditionally be salvaged and requires the extraction of the entire VAD system. We report here the successful eradication of a VAD driveline infection with a taurolidine-containing antimicrobial solution used for preventing the infection of cardiac implantable electronic devices. If replicated in more cases, the novel treatment concept described here may provide a valuable alternative management strategy of salvage rather than explantation for VAD driveline infection.
- 10 January 2022
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 9 (1) , 18
Open AccessEradication of Ventricular Assist Device Driveline Infection in Paediatric Patients with Taurolidine
Ventricular assist devices (VADs) are used to provide mechanical circulatory support to patients with end-stage heart failure. The driveline connecting the external power source to the pump(s) of the intra-corporal VAD breaches the protective skin barrier and provides a track for microbes to invade the interior of the patient’s body. Driveline infection constitutes a major and potentially fatal vulnerability of VAD therapy. Driveline infection cannot traditionally be salvaged and requires the extraction of the entire VAD system. We report here the successful eradication of a VAD driveline infection with a taurolidine-containing antimicrobial solution used for preventing the infection of cardiac implantable electronic devices. If replicated in more cases, the novel treatment concept described here may provide a valuable alternative management strategy of salvage rather than explantation for VAD driveline infection.
- Open Access
- 25 February 2019
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 42 (4) , 407-422
Longevity decoded: Insights from power consumption analyses into device construction and their clinical implications
Introduction: The longevity of a cardiac implantable electronic device (CIED) depends on how quickly the powers consumed by the device's functions exhaust its usable battery energy. A mathematical model for CIED power consumptions was developed and validated against longevity data from manufacturers.Methods: The programmable parameters for the Resonate X4 cardiac resynchronization therapy defibrillators (CRT‐Ds) on the Boston Scientific (St. Paul, MN, USA) online longevity calculator were designated as independent terms in the sum for the total power consumption. The reciprocal of longevity was plotted against variations in these terms. Linear and nonlinear regression analyses were used to fit the plots. The power consumed by pacing was theoretically derived and used as the calibrating tool for estimating the powers consumed by other functions and the usable battery energy. The same methodology was applied to the longevity data of other manufacturers’ CRT‐Ds.Results: Single chamber 100% pacing at 60 beats/min, 2.5 V, 0.4 ms, 500 Ω consumes ≈ 144 J/year. Shock therapy is 45–85% energy efficient. Multichamber pacing modes and maintaining readiness to pace a chamber consume power even if no pacing is delivered. Switching voltage regulation is theoretically more energy efficient than linear voltage regulation for powering pacing.Conclusions: The powers consumed by therapy functions are dictated by the patient's clinical needs, but healthcare professionals can extend device longevity by switching off dormant functions and simplifying the pacing mode. Choosing a device model with large usable battery energy, low background power, and energy efficient pacing and shock therapy for implantation will increase the probability of a long service lifespan.
- 25 February 2019
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 42 (4) , 407-422
Open AccessLongevity decoded: Insights from power consumption analyses into device construction and their clinical implications
Introduction: The longevity of a cardiac implantable electronic device (CIED) depends on how quickly the powers consumed by the device's functions exhaust its usable battery energy. A mathematical model for CIED power consumptions was developed and validated against longevity data from manufacturers.Methods: The programmable parameters for the Resonate X4 cardiac resynchronization therapy defibrillators (CRT‐Ds) on the Boston Scientific (St. Paul, MN, USA) online longevity calculator were designated as independent terms in the sum for the total power consumption. The reciprocal of longevity was plotted against variations in these terms. Linear and nonlinear regression analyses were used to fit the plots. The power consumed by pacing was theoretically derived and used as the calibrating tool for estimating the powers consumed by other functions and the usable battery energy. The same methodology was applied to the longevity data of other manufacturers’ CRT‐Ds.Results: Single chamber 100% pacing at 60 beats/min, 2.5 V, 0.4 ms, 500 Ω consumes ≈ 144 J/year. Shock therapy is 45–85% energy efficient. Multichamber pacing modes and maintaining readiness to pace a chamber consume power even if no pacing is delivered. Switching voltage regulation is theoretically more energy efficient than linear voltage regulation for powering pacing.Conclusions: The powers consumed by therapy functions are dictated by the patient's clinical needs, but healthcare professionals can extend device longevity by switching off dormant functions and simplifying the pacing mode. Choosing a device model with large usable battery energy, low background power, and energy efficient pacing and shock therapy for implantation will increase the probability of a long service lifespan.
- Open Access
- 1 March 2018
- Published by Elsevier in HeartRhythm Case Reports
- Vol. 4 (3) , 121-126
Inside-out abrasion and contained conductor cable externalization in a defibrillation lead with asymmetric conductor cable lumen distribution
- 1 March 2018
- Published by Elsevier in HeartRhythm Case Reports
- Vol. 4 (3) , 121-126
Open AccessInside-out abrasion and contained conductor cable externalization in a defibrillation lead with asymmetric conductor cable lumen distribution
- Open Access
- 1 September 2017
- Published by Elsevier in Indian Pacing and Electrophysiology Journal
- Vol. 17 (5) , 156-159
Multi-site multi-polar left ventricular pacing through persistent left superior vena cava in tricuspid valve disease
- 1 September 2017
- Published by Elsevier in Indian Pacing and Electrophysiology Journal
- Vol. 17 (5) , 156-159
Open AccessMulti-site multi-polar left ventricular pacing through persistent left superior vena cava in tricuspid valve disease
- Open Access
- 26 May 2017
- Published by Elsevier in Indian Pacing and Electrophysiology Journal
- Vol. 17 (4) , 111-112
First rib and venous anomalies – Anatomical challenges for transvenous implantation of cardiac electronic devices
- 26 May 2017
- Published by Elsevier in Indian Pacing and Electrophysiology Journal
- Vol. 17 (4) , 111-112
Open AccessFirst rib and venous anomalies – Anatomical challenges for transvenous implantation of cardiac electronic devices
- 15 January 2017
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 40 (1) , 75-96
Technologies for Prolonging Cardiac Implantable Electronic Device Longevity
Prolonged longevity of cardiac implantable electronic devices (CIEDs) is needed not only as a passive response to match the prolonging life expectancy of patient recipients, but will also actively prolong their life expectancy by avoiding/deferring the risks (and costs) associated with device replacement. CIEDs are still exclusively powered by nonrechargeable primary batteries, and energy exhaustion is the dominant and an inevitable cause of device replacement. The longevity of a CIED is thus determined by the attrition rate of its finite energy reserve. The energy available from a battery depends on its capacity (total amount of electric charge), chemistry (anode, cathode, and electrolyte), and internal architecture (stacked plate, folded plate, and spiral wound). The energy uses of a CIED vary and include a background current for running electronic circuitry, periodic radiofrequency telemetry, high‐voltage capacitor reformation, constant ventricular pacing, and sporadic shocks for the cardiac resynchronization therapy defibrillators. The energy use by a CIED is primarily determined by the patient recipient's clinical needs, but the energy stored in the device battery is entirely under the manufacturer's control. A larger battery capacity generally results in a longer‐lasting device, but improved battery chemistry and architecture may allow more space‐efficient designs. Armed with the necessary technical knowledge, healthcare professionals and purchasers will be empowered to make judicious selection on device models and maximize the utilization of all their energy‐saving features, to prolong device longevity for the benefits of their patients and healthcare systems.
- 15 January 2017
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 40 (1) , 75-96
Technologies for Prolonging Cardiac Implantable Electronic Device Longevity
Prolonged longevity of cardiac implantable electronic devices (CIEDs) is needed not only as a passive response to match the prolonging life expectancy of patient recipients, but will also actively prolong their life expectancy by avoiding/deferring the risks (and costs) associated with device replacement. CIEDs are still exclusively powered by nonrechargeable primary batteries, and energy exhaustion is the dominant and an inevitable cause of device replacement. The longevity of a CIED is thus determined by the attrition rate of its finite energy reserve. The energy available from a battery depends on its capacity (total amount of electric charge), chemistry (anode, cathode, and electrolyte), and internal architecture (stacked plate, folded plate, and spiral wound). The energy uses of a CIED vary and include a background current for running electronic circuitry, periodic radiofrequency telemetry, high‐voltage capacitor reformation, constant ventricular pacing, and sporadic shocks for the cardiac resynchronization therapy defibrillators. The energy use by a CIED is primarily determined by the patient recipient's clinical needs, but the energy stored in the device battery is entirely under the manufacturer's control. A larger battery capacity generally results in a longer‐lasting device, but improved battery chemistry and architecture may allow more space‐efficient designs. Armed with the necessary technical knowledge, healthcare professionals and purchasers will be empowered to make judicious selection on device models and maximize the utilization of all their energy‐saving features, to prolong device longevity for the benefits of their patients and healthcare systems.
- 1 September 2016
- Vol. 85 (3) , 193-195
Radial Multi-Site, Longitudinal Multi-Polar Epicardial Left Ventricular Pacing In Tricuspid Valve Disease
- 1 September 2016
- Vol. 85 (3) , 193-195
Radial Multi-Site, Longitudinal Multi-Polar Epicardial Left Ventricular Pacing In Tricuspid Valve Disease