Jin-Beom Chung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jin-Beom Chung has a total of 144 co-authors. Here are the top co-authors by number of shared publications:
Sang-Won Kang
18 shared publications- Tae Suk Suh
Department of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
18 shared publications Jae-Sung Kim
Department of Radiation Oncology, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
15 shared publicationsChanghoon Song
Department of Radiation Oncology, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
11 shared publicationsWoong Cho
Department of Radiation Oncology Seoul National University Boramae Medical Center Seoul Republic of Korea
10 shared publicationsKeun-Yong Eom
Department of Radiation Oncology, Virginia Commonwealth University, Richmond, VA, United States
9 shared publications
Latest Publications
- 1 November 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (11) , P11011
Screen-printed inorganic perovskite thick-film sensor for clinical electron beam quality assurance
In the field of radiation therapy, inorganic perovskites, which exhibit excellent radiation responsiveness, are attracting attention as solid-state sensor materials for precise quality assurance (QA). However, conventional nano-scale perovskite thin-films have limitations due to insufficient active volume in measuring high-energy (high-E) radiation characterized by high penetrating power. To overcome these limitations, we fabricated a micro-scale CsPbI 2 Br thick-film sensor and irradiated it with high-E electron beams of 6, 9, and 12 MeV using a clinical linear accelerator under experimental conditions closely simulating a clinical QA environment. The experimental results demonstrated that the fabricated sensor exhibited excellent linearity ( R 2 > 0.999) and repeatability (CV< 1.6%) within the dose range of 10 to 1000 MU. Furthermore, it showed a dose-rate independent response against dose-rate variations from 100 to 600 MU/min. In a comparative evaluation of the percent-depth dose (PDD) against an ionization chamber, the difference in R 50 was less than 1 mm, satisfying the clinical QA tolerance criterion. However, at deeper depths, overestimations were observed due to the photoelectric effect induced by scattered low-energy photons, which was attributed to the high atomic number of the sensor material. Additionally, this study has a limitation in evaluating long-term reliability due to the lack of proper encapsulation. In conclusion, the thick-film sensor fabricated in this study demonstrated outstanding dosimetric response characteristics. With further studies, such as the development of robust packaging techniques and compensation layers, it is highly anticipated to be widely utilized as a next-generation dosimeter for clinical radiotherapy QA.
- 1 November 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (11) , P11011
Screen-printed inorganic perovskite thick-film sensor for clinical electron beam quality assurance
In the field of radiation therapy, inorganic perovskites, which exhibit excellent radiation responsiveness, are attracting attention as solid-state sensor materials for precise quality assurance (QA). However, conventional nano-scale perovskite thin-films have limitations due to insufficient active volume in measuring high-energy (high-E) radiation characterized by high penetrating power. To overcome these limitations, we fabricated a micro-scale CsPbI 2 Br thick-film sensor and irradiated it with high-E electron beams of 6, 9, and 12 MeV using a clinical linear accelerator under experimental conditions closely simulating a clinical QA environment. The experimental results demonstrated that the fabricated sensor exhibited excellent linearity ( R 2 > 0.999) and repeatability (CV< 1.6%) within the dose range of 10 to 1000 MU. Furthermore, it showed a dose-rate independent response against dose-rate variations from 100 to 600 MU/min. In a comparative evaluation of the percent-depth dose (PDD) against an ionization chamber, the difference in R 50 was less than 1 mm, satisfying the clinical QA tolerance criterion. However, at deeper depths, overestimations were observed due to the photoelectric effect induced by scattered low-energy photons, which was attributed to the high atomic number of the sensor material. Additionally, this study has a limitation in evaluating long-term reliability due to the lack of proper encapsulation. In conclusion, the thick-film sensor fabricated in this study demonstrated outstanding dosimetric response characteristics. With further studies, such as the development of robust packaging techniques and compensation layers, it is highly anticipated to be widely utilized as a next-generation dosimeter for clinical radiotherapy QA.
- Open Access
- 30 July 2026
- Published by Wiley in Physica Status Solidi (a)
- Vol. 223 (15) , e70451
Development of a Polydimethylsiloxane‐Based Flexible Digital Bolus Dosimeter: From Unit‐Cell Characterization to Linear Array for Skin‐Dose Distribution Verification
In this study, we developed a flexible digital bolus dosimeter based on a polycrystalline HgI 2 photoconductor embedded in a tissue‐equivalent polydimethylsiloxane (PDMS) matrix, incorporating a 70 μm protective layer for skin‐dose evaluation. The dosimeter exhibited excellent linearity ( R 2 = 0.9996) within 2–400 MU and superior repeatability (standard deviation of 1.59%). Although the signal gradually decreased by approximately 8.3% (range from 5.6% to −2.7%) as the dose rate increased from 100 to 600 MU/min due to charge trapping and polarization, a stable response was maintained using a dose‐rate‐dependent correction factor or integrating advanced signal processing techniques. Mechanical stability tests up to 1000 bending cycles suggested the need for baseline correction on curved surfaces due to increased drift‐charge and photo‐charge. Subsequently, a 24‐pixel linear array dosimeter was fabricated on a flexible printed circuit board (fPCB) to evaluate continuous spatial dose distribution. When applied to a curved RSD chest phantom, the array reproduced consistent spatial dose distribution trends compared to radiochromic film at various gantry angles, with absolute dose differences of 3.51–7.05 cGy (7%–12%). These results demonstrate that the proposed platform is practical and suitable for evaluating skin‐dose distributions in complex geometries during radiotherapy.
- 30 July 2026
- Published by Wiley in Physica Status Solidi (a)
- Vol. 223 (15) , e70451
Open AccessDevelopment of a Polydimethylsiloxane‐Based Flexible Digital Bolus Dosimeter: From Unit‐Cell Characterization to Linear Array for Skin‐Dose Distribution Verification
In this study, we developed a flexible digital bolus dosimeter based on a polycrystalline HgI 2 photoconductor embedded in a tissue‐equivalent polydimethylsiloxane (PDMS) matrix, incorporating a 70 μm protective layer for skin‐dose evaluation. The dosimeter exhibited excellent linearity ( R 2 = 0.9996) within 2–400 MU and superior repeatability (standard deviation of 1.59%). Although the signal gradually decreased by approximately 8.3% (range from 5.6% to −2.7%) as the dose rate increased from 100 to 600 MU/min due to charge trapping and polarization, a stable response was maintained using a dose‐rate‐dependent correction factor or integrating advanced signal processing techniques. Mechanical stability tests up to 1000 bending cycles suggested the need for baseline correction on curved surfaces due to increased drift‐charge and photo‐charge. Subsequently, a 24‐pixel linear array dosimeter was fabricated on a flexible printed circuit board (fPCB) to evaluate continuous spatial dose distribution. When applied to a curved RSD chest phantom, the array reproduced consistent spatial dose distribution trends compared to radiochromic film at various gantry angles, with absolute dose differences of 3.51–7.05 cGy (7%–12%). These results demonstrate that the proposed platform is practical and suitable for evaluating skin‐dose distributions in complex geometries during radiotherapy.
- Open Access
- 25 June 2026
- Published by Wiley in Physica Status Solidi (a)
- Vol. 223 (13)
Feasibility Study of a Semi‐Circular Dosimeter for Patient‐Specific Quality Assurance in High‐Dose‐Rate Brachytherapy
High‐dose‐rate brachytherapy (HDR‐BT) delivers radiation using a radioactive source positioned close to the tumor, enabling highly localized dose distributions. However, patient‐specific quality assurance (PSQA) methods for HDR‐BT remain limited due to the radial nature of source irradiation and the lack of suitable dosimetric tools. In this study, a semi‐circular multipixel dosimeter is developed as a feasibility‐level PSQA detector for HDR‐BT. The curved geometry allows consistent control of the source‐to‐dosimeter distance and enables the measurement of radial dose variations around a 192 Ir source. The dosimeter performance is evaluated in terms of repeatability, dose linearity, and distance dependence. The experimental results demonstrate stable repeatability with a coefficient of variation of 0.4399%, excellent linearity over a dose range of 5–1000 cGy (R 2 = 0.9989), and a clear distance‐dependent response consistent with geometric dose fall‐off. Monte Carlo simulations performed under identical conditions show similar trends and support the physical validity of the measured results. The observed discrepancies between measurement and simulation are attributed to environmental effects and detector‐specific nonidealities. These findings indicate that the proposed semi‐circular dosimeter has strong potential for measuring radial dose distributions and provides a foundation for developing practical PSQA systems for HDR‐BT.
- 25 June 2026
- Published by Wiley in Physica Status Solidi (a)
- Vol. 223 (13)
Open AccessFeasibility Study of a Semi‐Circular Dosimeter for Patient‐Specific Quality Assurance in High‐Dose‐Rate Brachytherapy
High‐dose‐rate brachytherapy (HDR‐BT) delivers radiation using a radioactive source positioned close to the tumor, enabling highly localized dose distributions. However, patient‐specific quality assurance (PSQA) methods for HDR‐BT remain limited due to the radial nature of source irradiation and the lack of suitable dosimetric tools. In this study, a semi‐circular multipixel dosimeter is developed as a feasibility‐level PSQA detector for HDR‐BT. The curved geometry allows consistent control of the source‐to‐dosimeter distance and enables the measurement of radial dose variations around a 192 Ir source. The dosimeter performance is evaluated in terms of repeatability, dose linearity, and distance dependence. The experimental results demonstrate stable repeatability with a coefficient of variation of 0.4399%, excellent linearity over a dose range of 5–1000 cGy (R 2 = 0.9989), and a clear distance‐dependent response consistent with geometric dose fall‐off. Monte Carlo simulations performed under identical conditions show similar trends and support the physical validity of the measured results. The observed discrepancies between measurement and simulation are attributed to environmental effects and detector‐specific nonidealities. These findings indicate that the proposed semi‐circular dosimeter has strong potential for measuring radial dose distributions and provides a foundation for developing practical PSQA systems for HDR‐BT.
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , P04021
Exploring CsPbIBr 2 -based Sensor for clinical QA of therapeutic electron beam
Quality assurance (QA) in radiotherapy is essential to ensure precise dose delivery; however, conventional ionization chambers, including parallel plate chambers (PPCs), exhibit inherent structural limitations, particularly under small-field conditions. In this study, a CsPbIBr 2 -based unit-cell radiation sensor utilizing a halide perovskite material was fabricated, leveraging its capability for compact thin-film construction. The response characteristics of the sensor to high-energy electron beams (6, 9, and 12 MeV) generated by a clinical linear accelerator were systematically evaluated to assess its suitability as a clinical QA dosimeter. The fabricated sensor demonstrated stable linearity and repeatability across various irradiation conditions, maintaining consistent performance regardless of dose-rate variations. Furthermore, electron beam-quality indices derived from depth-dose curve analyses closely matched the reference values obtained with a PPC, satisfying established tolerance criteria for clinical electron beam-quality QA. These findings indicate that the CsPbIBr 2 -based sensor offers reliable and stable dosimetric performance in clinical electron beam QA settings. However, increasing deviation was observed in the low-energy region under certain conditions, which was potentially attributable to low-energy photon influence. Addressing this limitation through further investigation is necessary. With continued development, the proposed sensor holds promise as a practical dosimeter for clinical QA applications.
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , P04021
Exploring CsPbIBr 2 -based Sensor for clinical QA of therapeutic electron beam
Quality assurance (QA) in radiotherapy is essential to ensure precise dose delivery; however, conventional ionization chambers, including parallel plate chambers (PPCs), exhibit inherent structural limitations, particularly under small-field conditions. In this study, a CsPbIBr 2 -based unit-cell radiation sensor utilizing a halide perovskite material was fabricated, leveraging its capability for compact thin-film construction. The response characteristics of the sensor to high-energy electron beams (6, 9, and 12 MeV) generated by a clinical linear accelerator were systematically evaluated to assess its suitability as a clinical QA dosimeter. The fabricated sensor demonstrated stable linearity and repeatability across various irradiation conditions, maintaining consistent performance regardless of dose-rate variations. Furthermore, electron beam-quality indices derived from depth-dose curve analyses closely matched the reference values obtained with a PPC, satisfying established tolerance criteria for clinical electron beam-quality QA. These findings indicate that the CsPbIBr 2 -based sensor offers reliable and stable dosimetric performance in clinical electron beam QA settings. However, increasing deviation was observed in the low-energy region under certain conditions, which was potentially attributable to low-energy photon influence. Addressing this limitation through further investigation is necessary. With continued development, the proposed sensor holds promise as a practical dosimeter for clinical QA applications.
- 30 December 2025
- Published by Korean Society of Radiological Science in Journal of Radiological Science and Technology
- Vol. 48 (6) , 659-667
Distance and Angular Dependence of Polycrystalline Semiconductor Dosimeters Based on Mercury(II) Iodide (HgI2) and Tallium(I) Bromide(TlBr) for an Iridium-192 Source: Experimental Measurements and Monte Carlo Simulation Comparison
- 30 December 2025
- Published by Korean Society of Radiological Science in Journal of Radiological Science and Technology
- Vol. 48 (6) , 659-667
Distance and Angular Dependence of Polycrystalline Semiconductor Dosimeters Based on Mercury(II) Iodide (HgI2) and Tallium(I) Bromide(TlBr) for an Iridium-192 Source: Experimental Measurements and Monte Carlo Simulation Comparison
- 1 December 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (12) , P12005
Development and evaluation of polycrystalline semiconductor dosimeter for quality assurance application in high-dose-rate brachytherapy
This study aims to develop and evaluate polycrystalline semiconductor dosimeters (PSDs) to establish a digital quality assurance (QA) system for high-dose-rate (HDR) brachytherapy. PSDs were fabricated using four polycrystalline materials: mercury(II) iodide (HgI 2 ), lead(II) iodide (PbI 2 ), lead(II) oxide (PbO), and thallium(I) bromide (TlBr). To evaluate the performance of the fabricated dosimeters, dosimetric parameters, including reproducibility, dose-response linearity, distance dependence, and angular dependence, were measured using an Iridium-192 (Ir-192) radioisotope source and compared with corresponding parameters measured by a parallel-plane ionization chamber. For reproducibility, each PSD was irradiated 10 consecutive times. Dose-response linearity was assessed for doses ranging from 0.1 to 10 Gy. Distance dependence was evaluated by administering a dose of 1 Gy at source-to-dosimeter distances ranging from 1 to 12 cm, in increments of 0.25 cm. Angular dependence was assessed by positioning the PSDs 1 cm below the Ir-192 source and measuring signals at angles of 15°, 30°, and 45° relative to the reference angle of 0°, where the PSD's central axis was parallel to the source. Signals measured at 15°, 30°, and 45° were normalized to those measured at 0°. The PSD using PbO demonstrated the best reproducibility, with a coefficient of variation of 0.85%, and showed a minimal difference of -0.03% compared with the ionization chamber. Other PSDs also achieved excellent reproducibility, with relative standard deviations within 1.5%. For dose-response linearity, all PSDs achieved an R 2 value of 0.9993 or higher, outperforming the ionization chamber, which had an R 2 value of 0.9983. Regarding distance dependence, the slope of the power function and the distance corresponding to 50% intensity ( D 50 ) were analyzed in comparison with the ionization chamber. The PSD using PbI 2 exhibited the closest agreement, with a slope difference of 0.103 and a difference of 0.003 cm for D 50 . For angular dependence, the PSD using PbI 2 demonstrated the least attenuation, with a redcution of 13.2% in signal intensity at 45° compared with 0°. The findings of this study indicated that PbI 2 was the most suitable material for PSDs by comparing with the ionization chamber in terms of measurement characteristics. Furthermore, this study provided valuable insights into optimizing semiconductor materials for various applications in HDR brachytherapy QA.
- 1 December 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (12) , P12005
Development and evaluation of polycrystalline semiconductor dosimeter for quality assurance application in high-dose-rate brachytherapy
This study aims to develop and evaluate polycrystalline semiconductor dosimeters (PSDs) to establish a digital quality assurance (QA) system for high-dose-rate (HDR) brachytherapy. PSDs were fabricated using four polycrystalline materials: mercury(II) iodide (HgI 2 ), lead(II) iodide (PbI 2 ), lead(II) oxide (PbO), and thallium(I) bromide (TlBr). To evaluate the performance of the fabricated dosimeters, dosimetric parameters, including reproducibility, dose-response linearity, distance dependence, and angular dependence, were measured using an Iridium-192 (Ir-192) radioisotope source and compared with corresponding parameters measured by a parallel-plane ionization chamber. For reproducibility, each PSD was irradiated 10 consecutive times. Dose-response linearity was assessed for doses ranging from 0.1 to 10 Gy. Distance dependence was evaluated by administering a dose of 1 Gy at source-to-dosimeter distances ranging from 1 to 12 cm, in increments of 0.25 cm. Angular dependence was assessed by positioning the PSDs 1 cm below the Ir-192 source and measuring signals at angles of 15°, 30°, and 45° relative to the reference angle of 0°, where the PSD's central axis was parallel to the source. Signals measured at 15°, 30°, and 45° were normalized to those measured at 0°. The PSD using PbO demonstrated the best reproducibility, with a coefficient of variation of 0.85%, and showed a minimal difference of -0.03% compared with the ionization chamber. Other PSDs also achieved excellent reproducibility, with relative standard deviations within 1.5%. For dose-response linearity, all PSDs achieved an R 2 value of 0.9993 or higher, outperforming the ionization chamber, which had an R 2 value of 0.9983. Regarding distance dependence, the slope of the power function and the distance corresponding to 50% intensity ( D 50 ) were analyzed in comparison with the ionization chamber. The PSD using PbI 2 exhibited the closest agreement, with a slope difference of 0.103 and a difference of 0.003 cm for D 50 . For angular dependence, the PSD using PbI 2 demonstrated the least attenuation, with a redcution of 13.2% in signal intensity at 45° compared with 0°. The findings of this study indicated that PbI 2 was the most suitable material for PSDs by comparing with the ionization chamber in terms of measurement characteristics. Furthermore, this study provided valuable insights into optimizing semiconductor materials for various applications in HDR brachytherapy QA.
- Open Access
- 19 November 2025
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 15, 1628318
Dosimetric parameter determination of a carbon-nanotube based miniature x-ray tube for HDR brachytherapy
Purpose: This study aims to determine key dosimetric parameters of a vacuum-sealed miniature X-ray tube (mXT) equipped with a carbon nanotube field emitter for application in HDR brachytherapy. Methods: Dosimetric parameters, including dose-rate constant, radial dose, and anisotropic function, were assessed 1 cm below the mXT employing EBT3 film and a custom-manufactured acrylonitrile butadiene styrene (ABS) phantom. The dose-rate constant and radial-dose functions were measured following the standard polar angles and radial distances prescribed by the AAPM TG-43 protocol. However, anisotropic function measurements were selectively conducted due to the directional dependence of Gafchromic EBT3 film when placed coplanar to the X-ray source. To minimize this effect, films were positioned 1 cm below the mXT, which restricted the measurable angular range. These parameters were also computed in both a virtual ABS and water phantom using the MCNP6.1 code. Correlation factors for different materials were obtained to adjust measured parameters in the ABS phantom to those in water, based on the calculated depth–dose curve. The dosimetric parameters were then determined by comparing the measured and calculated values. Results: The dose-rate constant was determined to be 1344.14 cGy·h -1 ·μA -1 . Radial-dose functions were 0.49, 0.33, 0.22, and 0.15 at radial distances of 2.0, 3.0, 4.0, and 5.0 cm, respectively. The difference between measured and calculated radial-dose functions in water remained within 0.10, averaging 0.05. Anisotropic functions exhibited an increase with the radial distance, approaching 0° angle. Azimuthal angular dependence was deemed acceptable. Conclusion: This study successfully acquired both measured and calculated parameters for the newly developed mXT. The findings affirm that the dosimetric parameters of the mXT are within acceptable limits for clinical HDR brachytherapy applications.
- 19 November 2025
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 15, 1628318
Open AccessDosimetric parameter determination of a carbon-nanotube based miniature x-ray tube for HDR brachytherapy
Purpose: This study aims to determine key dosimetric parameters of a vacuum-sealed miniature X-ray tube (mXT) equipped with a carbon nanotube field emitter for application in HDR brachytherapy. Methods: Dosimetric parameters, including dose-rate constant, radial dose, and anisotropic function, were assessed 1 cm below the mXT employing EBT3 film and a custom-manufactured acrylonitrile butadiene styrene (ABS) phantom. The dose-rate constant and radial-dose functions were measured following the standard polar angles and radial distances prescribed by the AAPM TG-43 protocol. However, anisotropic function measurements were selectively conducted due to the directional dependence of Gafchromic EBT3 film when placed coplanar to the X-ray source. To minimize this effect, films were positioned 1 cm below the mXT, which restricted the measurable angular range. These parameters were also computed in both a virtual ABS and water phantom using the MCNP6.1 code. Correlation factors for different materials were obtained to adjust measured parameters in the ABS phantom to those in water, based on the calculated depth–dose curve. The dosimetric parameters were then determined by comparing the measured and calculated values. Results: The dose-rate constant was determined to be 1344.14 cGy·h -1 ·μA -1 . Radial-dose functions were 0.49, 0.33, 0.22, and 0.15 at radial distances of 2.0, 3.0, 4.0, and 5.0 cm, respectively. The difference between measured and calculated radial-dose functions in water remained within 0.10, averaging 0.05. Anisotropic functions exhibited an increase with the radial distance, approaching 0° angle. Azimuthal angular dependence was deemed acceptable. Conclusion: This study successfully acquired both measured and calculated parameters for the newly developed mXT. The findings affirm that the dosimetric parameters of the mXT are within acceptable limits for clinical HDR brachytherapy applications.
- 1 February 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (02) , P02026
Development and evaluation of dose management system for paediatric image-guided radiotherapy
Paediatric patients exhibit highened sensitivity to radiation compared to adults during image-guided radiation therapy, underscring the need for careful dose management, even for minimal exposures. This study aims to develop and evaluate a system for efficiently recording and managing imaging doses. Monte Carlo (MC) simulations were employed to accurately model the radiation dose from the cone-beam computed tomography (CBCT) system utilized in this study. Additionally, a custom detector was designed for image processing. The full-pan mode was chosen to reconstruct images for paediatric patients from data acquired through a 200∘ rotation. In the dosimetric analysis, the tissue-absorbed doses were calculated using MC simulations within a computerizsed anatomical phantom tailored for paediatric use. The study utilized hybrid anthropomorphic phantom representing ages 0, 1, 5, 10, 15, and 30 years to compute and record organ doses. The developed system accounted for offsets generated during the image verification after patient examinations and treatments, applying these adjustments to image dose calculations. Finalized results were stored on a server, maintaining a record of daily imaging doses for each patient. The simulation process required approximately 20 hours per inspection, with results converted to the Digital Imaging and Communications in Medicine (DICOM) format and analysed using the Eclipse treatment planning system. Among all age groups, the 0-year-old phantom received the highest radiation doses across all organs due to minimal attenuation before reaching the target organs. The greatest dose variation based on rotation angle was observed in the eyes and lens. This study successfully developed and evaluated a retrospective system for managing and optimizing CBCT image doses in paediatric radiotherapy, demonstrating its potential for improving radiation safety and dose tracking in young patients.
- 1 February 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (02) , P02026
Development and evaluation of dose management system for paediatric image-guided radiotherapy
Paediatric patients exhibit highened sensitivity to radiation compared to adults during image-guided radiation therapy, underscring the need for careful dose management, even for minimal exposures. This study aims to develop and evaluate a system for efficiently recording and managing imaging doses. Monte Carlo (MC) simulations were employed to accurately model the radiation dose from the cone-beam computed tomography (CBCT) system utilized in this study. Additionally, a custom detector was designed for image processing. The full-pan mode was chosen to reconstruct images for paediatric patients from data acquired through a 200∘ rotation. In the dosimetric analysis, the tissue-absorbed doses were calculated using MC simulations within a computerizsed anatomical phantom tailored for paediatric use. The study utilized hybrid anthropomorphic phantom representing ages 0, 1, 5, 10, 15, and 30 years to compute and record organ doses. The developed system accounted for offsets generated during the image verification after patient examinations and treatments, applying these adjustments to image dose calculations. Finalized results were stored on a server, maintaining a record of daily imaging doses for each patient. The simulation process required approximately 20 hours per inspection, with results converted to the Digital Imaging and Communications in Medicine (DICOM) format and analysed using the Eclipse treatment planning system. Among all age groups, the 0-year-old phantom received the highest radiation doses across all organs due to minimal attenuation before reaching the target organs. The greatest dose variation based on rotation angle was observed in the eyes and lens. This study successfully developed and evaluated a retrospective system for managing and optimizing CBCT image doses in paediatric radiotherapy, demonstrating its potential for improving radiation safety and dose tracking in young patients.
- 1 September 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (09) , P09035
Evaluation of photoconductor and scintillator hybrid dosimeters for radiation therapy quality assurance
Radiation detectors have two main detection mechanisms: direct conversion, which utilises a photoconductor to directly convert radiation into an electrical signal, and indirect conversion, which utilises a scintillator to convert radiation into visible light, which is subsequently converted into an electrical signal. The photoconductor material, mercury (II) iodide (HgI2) sensitive to visible light, has the property of gradually decreasing signal for repeated irradiation beams. Therefore, this study aimed to improve the signal magnitude and stability to repeated measurements of polycrystalline HgI2 by mixing 0, 4, 6, 8, 10, and 20 weight percent (wt%) of terbium-doped gadolinium oxysulfide (GOS:Tb), a scintillator material that emits visible light. The performance of these dosimeters was evaluated with a focus on dosimetric parameters such as signal quantity, short-term repeatability, dose-response linearity, and dose-rate dependence to assess their potential application in radiotherapy quality assurance (QA). The results from the dosimeters were compared with those from a metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeter and an ionisation chamber. Peak was found for the dosimeter with 8 wt% GOS:Tb but decreased for the dosimeters with 10 and 20 wt% GOS:Tb. The standard deviations of short-term repeatability were 1.45%, 0.86%, 1.18%, 1.51%, 131%, and 4.48% for dosimeters with 0, 4, 6, 8, 10, and 20 wt% GOS:Tb, respectively. The dosimeters with 4 and 6 wt% GOS:Tb had better standard deviations of repeatability than the MOSFET (1.35%), but not better than the ionization chamber (0.5%). All dosimeters, the MOSFET, and the ion chamber demonstrated excellent dose-response linearity for monitor unit (MU) values ranging from 2 to 500, with R 2 values exceeding 0.9997. The sensitivity analysed using the linear slope was the highest for the dosimeter with 6 wt% GOS:Tb (0.103) and the MOSFET (0.0103) among all dosimeters. The dosimeter with 6 wt% GOS:Tb and the MOSFET exhibited deviations of 4.64% and 3.31%, respectively, at a dose rate of 100 cGy/min, thus failing to meet the evaluation standard of within 2%. The ion chamber, however, achieved compliance with a deviation of 0.15%. Therefore, it is necessary to apply correction factors to each dose rate when using hybrid dosimeters for QA. The optimal mixing ratio of GOS:Tb for manufacturing the hybrid dosimeter was determined to be 6 wt%, suggesting signal amplification through visible light and a potential improvement in operational stability through pore filling of the material.
- 1 September 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (09) , P09035
Evaluation of photoconductor and scintillator hybrid dosimeters for radiation therapy quality assurance
Radiation detectors have two main detection mechanisms: direct conversion, which utilises a photoconductor to directly convert radiation into an electrical signal, and indirect conversion, which utilises a scintillator to convert radiation into visible light, which is subsequently converted into an electrical signal. The photoconductor material, mercury (II) iodide (HgI2) sensitive to visible light, has the property of gradually decreasing signal for repeated irradiation beams. Therefore, this study aimed to improve the signal magnitude and stability to repeated measurements of polycrystalline HgI2 by mixing 0, 4, 6, 8, 10, and 20 weight percent (wt%) of terbium-doped gadolinium oxysulfide (GOS:Tb), a scintillator material that emits visible light. The performance of these dosimeters was evaluated with a focus on dosimetric parameters such as signal quantity, short-term repeatability, dose-response linearity, and dose-rate dependence to assess their potential application in radiotherapy quality assurance (QA). The results from the dosimeters were compared with those from a metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeter and an ionisation chamber. Peak was found for the dosimeter with 8 wt% GOS:Tb but decreased for the dosimeters with 10 and 20 wt% GOS:Tb. The standard deviations of short-term repeatability were 1.45%, 0.86%, 1.18%, 1.51%, 131%, and 4.48% for dosimeters with 0, 4, 6, 8, 10, and 20 wt% GOS:Tb, respectively. The dosimeters with 4 and 6 wt% GOS:Tb had better standard deviations of repeatability than the MOSFET (1.35%), but not better than the ionization chamber (0.5%). All dosimeters, the MOSFET, and the ion chamber demonstrated excellent dose-response linearity for monitor unit (MU) values ranging from 2 to 500, with R 2 values exceeding 0.9997. The sensitivity analysed using the linear slope was the highest for the dosimeter with 6 wt% GOS:Tb (0.103) and the MOSFET (0.0103) among all dosimeters. The dosimeter with 6 wt% GOS:Tb and the MOSFET exhibited deviations of 4.64% and 3.31%, respectively, at a dose rate of 100 cGy/min, thus failing to meet the evaluation standard of within 2%. The ion chamber, however, achieved compliance with a deviation of 0.15%. Therefore, it is necessary to apply correction factors to each dose rate when using hybrid dosimeters for QA. The optimal mixing ratio of GOS:Tb for manufacturing the hybrid dosimeter was determined to be 6 wt%, suggesting signal amplification through visible light and a potential improvement in operational stability through pore filling of the material.
- 29 June 2023
- Published by Springer Nature in Journal of the Korean Physical Society
- Vol. 83 (3) , 216-225
Development of 3D printed patient-specific compensator for total body irradiation based on CT images
- 29 June 2023
- Published by Springer Nature in Journal of the Korean Physical Society
- Vol. 83 (3) , 216-225
Development of 3D printed patient-specific compensator for total body irradiation based on CT images