Zhaoyuan Leong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhaoyuan Leong has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Nicola A. Morley
University of Sheffield
5 shared publications Nicola Morley
3 shared publications- Russell Goodall
The University of Sheffield
3 shared publications Iain Todd
2 shared publicationsRussell Goodall
2 shared publicationsYuhe Huang
Department of Materials Science & Engineering, Sir Robert Hadfield Building, Mappin St, Sheffield, S1 3JD, UK
2 shared publications
Latest Publications
- Open Access
- 29 June 2023
- Published by Elsevier in Acta Materialia
- Vol. 256
Composition and phase structure dependence of magnetic properties for Co2FeCr0.5Alx (x=0.9, 1.2) multi principal component alloys
- 29 June 2023
- Published by Elsevier in Acta Materialia
- Vol. 256
Open AccessComposition and phase structure dependence of magnetic properties for Co2FeCr0.5Alx (x=0.9, 1.2) multi principal component alloys
- 19 February 2022
- Published by Elsevier in Intermetallics
- Vol. 144, 107462
Pairwise dilatational strain as a parametric model describing potential secondary phase formation and high-angle grain misorientation in as-cast high-entropy alloys
- 19 February 2022
- Published by Elsevier in Intermetallics
- Vol. 144, 107462
Pairwise dilatational strain as a parametric model describing potential secondary phase formation and high-angle grain misorientation in as-cast high-entropy alloys
- Open Access
- 26 November 2021
- Published by MDPI AG in Journal of Composites Science
- Vol. 5 (12) , 311
Can Empirical Biplots Predict High Entropy Oxide Phases?
High entropy oxides are entropy-stabilised oxides that adopt specific disordered structures due to entropy stabilisation. They are a new class of materials that utilises the high-entropy concept first discovered in metallic alloys. They can have interesting properties due to the interactions at the electronic level and can be combined with other materials to make composite structures. The design of new meta-materials that utilise this concept to solve real-world problems may be a possibility but further understanding of how their phase stabilisation is required. In this work, biplots of the composition’s mean electronegativity are plotted against the electron-per-atom ratio of the compounds. The test dataset accuracy in the resulting biplots improves from 78% to 100% when using atomic-number-per-atom Z/a ratios as a biplot parameter. Phase stability maps were constructed using a Voronoi tessellation. This can be of use in determining stability at composite material interfaces.
- 26 November 2021
- Published by MDPI AG in Journal of Composites Science
- Vol. 5 (12) , 311
Open AccessCan Empirical Biplots Predict High Entropy Oxide Phases?
High entropy oxides are entropy-stabilised oxides that adopt specific disordered structures due to entropy stabilisation. They are a new class of materials that utilises the high-entropy concept first discovered in metallic alloys. They can have interesting properties due to the interactions at the electronic level and can be combined with other materials to make composite structures. The design of new meta-materials that utilise this concept to solve real-world problems may be a possibility but further understanding of how their phase stabilisation is required. In this work, biplots of the composition’s mean electronegativity are plotted against the electron-per-atom ratio of the compounds. The test dataset accuracy in the resulting biplots improves from 78% to 100% when using atomic-number-per-atom Z/a ratios as a biplot parameter. Phase stability maps were constructed using a Voronoi tessellation. This can be of use in determining stability at composite material interfaces.
- Open Access
- 29 September 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (10) , 1185
Integrated Fabrication of Novel Inkjet-Printed Silver Nanoparticle Sensors on Carbon Fiber Reinforced Nylon Composites
Inkjet-printing technology enables the contactless deposition of functional materials such as conductive inks on surfaces, hence reducing contamination and the risk of substrate damage. In printed electronics, inkjet technology offers the significant advantage of controlling the volume of material deposited, and therefore the fine-tuning of the printed geometry, which is crucial for the performance of the final printed electronics. Inkjet printing of functional inks can be used to produce sensors to detect failure of mechanical structures such as carbon fiber reinforced composite (CFRC) components, instead of using attached sensors, which are subject to delamination. Here, silver nanoparticle-based strain sensors were embedded directly in an insulated carbon-fiber laminate by using inkjet printing to achieve an optimized conductive and adhesive geometry, forming a piezoresistive strain sensor. Following the inkjet-printing optimization process, the sensor conductivity and adhesion performance were evaluated. Finally, the sensor was quantified by using a bending rig which applied a pre-determined strain, with the response indicating an accurate sensitivity as the resistance increased with an increased strain. The ability to embed the sensor directly on the CFRC prevents the use of interfacial adhesives which is the main source of failure due to delamination.
- 29 September 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (10) , 1185
Open AccessIntegrated Fabrication of Novel Inkjet-Printed Silver Nanoparticle Sensors on Carbon Fiber Reinforced Nylon Composites
Inkjet-printing technology enables the contactless deposition of functional materials such as conductive inks on surfaces, hence reducing contamination and the risk of substrate damage. In printed electronics, inkjet technology offers the significant advantage of controlling the volume of material deposited, and therefore the fine-tuning of the printed geometry, which is crucial for the performance of the final printed electronics. Inkjet printing of functional inks can be used to produce sensors to detect failure of mechanical structures such as carbon fiber reinforced composite (CFRC) components, instead of using attached sensors, which are subject to delamination. Here, silver nanoparticle-based strain sensors were embedded directly in an insulated carbon-fiber laminate by using inkjet printing to achieve an optimized conductive and adhesive geometry, forming a piezoresistive strain sensor. Following the inkjet-printing optimization process, the sensor conductivity and adhesion performance were evaluated. Finally, the sensor was quantified by using a bending rig which applied a pre-determined strain, with the response indicating an accurate sensitivity as the resistance increased with an increased strain. The ability to embed the sensor directly on the CFRC prevents the use of interfacial adhesives which is the main source of failure due to delamination.
- Open Access
- 22 June 2021
- Published by Wiley in Advanced Engineering Materials
- Vol. 23 (9) , 2100313
Flat Inkjet‐Printed Copper Induction Coils for Magnetostrictive Structural Health Monitoring: A Comparison with Bulk Air Coils and an anisotropic magnetoresistive sensor (AMR) Sensor
Structural health monitoring (SHM) represents the next generation of carbon fiber‐reinforced composite nondestructive testing. One challenge facing the application of magnetostrictive SHM is the lightweighting and ease of installation of actuators and sensors. Inkjet printing (IJP) technology is well suited to produce miniaturized electronic induction sensors that can be paired with magnetostrictive actuators to detect strain. These sensors have several advantages: their thicknesses can be minimized, the surface area can be maximized to increase sensitivity, and complex multifilar coil configurations can be fabricated. A parametric study of the efficacy of IJP induction coils with different parameters (number of coils, monofilar/bifilar, size) tested on a number of actuator‐functionalized composite coupons (FeSiB ribbon and impregnated epoxy sensors) is conducted. The samples are characterized by measuring their inductance response through induced strains. Increased sensitivity and accuracy of the 10‐turn monofilar IJP sensor are shown with respect to 1) 70‐turn hand‐wound coils, 2) a three‐axis AMR sensor, and 3) other IJP actuators with <10 turns. This is attributed to increased contact area to the composite surface and the requirement of minimum sensitivity (i.e., the number of turns and surface area) for strain detection.
- 22 June 2021
- Published by Wiley in Advanced Engineering Materials
- Vol. 23 (9) , 2100313
Open AccessFlat Inkjet‐Printed Copper Induction Coils for Magnetostrictive Structural Health Monitoring: A Comparison with Bulk Air Coils and an anisotropic magnetoresistive sensor (AMR) Sensor
Structural health monitoring (SHM) represents the next generation of carbon fiber‐reinforced composite nondestructive testing. One challenge facing the application of magnetostrictive SHM is the lightweighting and ease of installation of actuators and sensors. Inkjet printing (IJP) technology is well suited to produce miniaturized electronic induction sensors that can be paired with magnetostrictive actuators to detect strain. These sensors have several advantages: their thicknesses can be minimized, the surface area can be maximized to increase sensitivity, and complex multifilar coil configurations can be fabricated. A parametric study of the efficacy of IJP induction coils with different parameters (number of coils, monofilar/bifilar, size) tested on a number of actuator‐functionalized composite coupons (FeSiB ribbon and impregnated epoxy sensors) is conducted. The samples are characterized by measuring their inductance response through induced strains. Increased sensitivity and accuracy of the 10‐turn monofilar IJP sensor are shown with respect to 1) 70‐turn hand‐wound coils, 2) a three‐axis AMR sensor, and 3) other IJP actuators with <10 turns. This is attributed to increased contact area to the composite surface and the requirement of minimum sensitivity (i.e., the number of turns and surface area) for strain detection.
- Open Access
- 2 September 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-12
Magnetic properties of the complex concentrated alloy system CoFeNi0.5Cr0.5Alx
We study the change in magnetisation with paramagnetic Al addition in the CoFeNi0.5Cr0.5–Alx (x: 0, 0.5, 1, and 1.5) complex concentrated alloy. The compositions were developed utilising the Mulliken electronegativity and d-electron/atom ratio. Spherical FeCr rich nanoprecipitates are observed for X: 1.0 and 1.5 in an AlCoNi-rich matrix. A ~ 5 × increase in magnetisation (from 22 to 96 Am2/kg) coincides with this nanoprecipitate formation—the main magnetic contribution is determined to be from FeCr nanoprecipitates. The magnetisation increase is strange as paramagnetic Al addition dilutes the ferromagnetic Fe/Co/Ni additions. In this paper we discuss the magnetic and structural characterisation of the CoFeNi0.5Cr0.5–Alx composition and attempt to relate it to the interfacial energy.
- 2 September 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-12
Open AccessMagnetic properties of the complex concentrated alloy system CoFeNi0.5Cr0.5Alx
We study the change in magnetisation with paramagnetic Al addition in the CoFeNi0.5Cr0.5–Alx (x: 0, 0.5, 1, and 1.5) complex concentrated alloy. The compositions were developed utilising the Mulliken electronegativity and d-electron/atom ratio. Spherical FeCr rich nanoprecipitates are observed for X: 1.0 and 1.5 in an AlCoNi-rich matrix. A ~ 5 × increase in magnetisation (from 22 to 96 Am2/kg) coincides with this nanoprecipitate formation—the main magnetic contribution is determined to be from FeCr nanoprecipitates. The magnetisation increase is strange as paramagnetic Al addition dilutes the ferromagnetic Fe/Co/Ni additions. In this paper we discuss the magnetic and structural characterisation of the CoFeNi0.5Cr0.5–Alx composition and attempt to relate it to the interfacial energy.
- Open Access
Refining As-Cast Structures of Novel SixTiVCrZr High-Entropy Alloys Using Estimated Effective Solidification Temperature Obtained Using Chvorinov’s Rule
High-entropy alloys (HEAs), i.e., multicomponent alloys where (typically five or more) elements are combined in equal, or roughly equal, quantities, are of great current interest, due to their formation of single, simple structured phases, and the unusual properties they can potentially exhibit. Phase presence may be predicted using semi-empirical methods, but deviations from predictions may be seen during the course of alloy synthesis, with the formation of unexpected phases. The generation of such phases may be controlled with knowledge of the effective solidification temperature; in this full article, Chvorinov’s rule for solidification time is used to estimate this temperature as part of the design of a new multiphase alloy system, TiVCrZr-Six. Further heat treatment of the TiVCrZr-Si system confirms the applicability of this approach. The new compositions demonstrate mechanical properties that suggest potential for optimization for high-temperature applications.
Open AccessRefining As-Cast Structures of Novel SixTiVCrZr High-Entropy Alloys Using Estimated Effective Solidification Temperature Obtained Using Chvorinov’s Rule
High-entropy alloys (HEAs), i.e., multicomponent alloys where (typically five or more) elements are combined in equal, or roughly equal, quantities, are of great current interest, due to their formation of single, simple structured phases, and the unusual properties they can potentially exhibit. Phase presence may be predicted using semi-empirical methods, but deviations from predictions may be seen during the course of alloy synthesis, with the formation of unexpected phases. The generation of such phases may be controlled with knowledge of the effective solidification temperature; in this full article, Chvorinov’s rule for solidification time is used to estimate this temperature as part of the design of a new multiphase alloy system, TiVCrZr-Six. Further heat treatment of the TiVCrZr-Si system confirms the applicability of this approach. The new compositions demonstrate mechanical properties that suggest potential for optimization for high-temperature applications.
- Open Access
Design and Development of Magnetostrictive Actuators and Sensors for Structural Health Monitoring
Carbon Fibre Reinforced Polymer composite (CFRP) is widely used in the aerospace industry, but is prone to delamination, which is a major causes of failure. Structural Health Monitoring (SHM) systems need to be developed to determine the damage occurring within it. Our motivation is to design cost-effective new sensors and a data acquisition system for magnetostrictive structural health monitoring of aerospace composites using a simple RLC circuit. The developed system is tested on magnetostrictive FeSiB and CoSiB actuator ribbons using a bending rig. Our results show detectable sensitivity of inductors as low as 0.6 μH for a bending rig radii between 600 to 300 mm (equivalent to 0.8 to 1.7 mStrain), which show a strain sensitivity resolution of 0.01 μStrain (surface area: ~36 mm2). This value is at the detectability limit of our fabricated system. The best resolution (1.86 μStrain) was obtained from a 70-turn copper (~64 μH) wire inductor (surface area: ~400 mm2) that was paired with a FeSiB actuator.
Open AccessDesign and Development of Magnetostrictive Actuators and Sensors for Structural Health Monitoring
Carbon Fibre Reinforced Polymer composite (CFRP) is widely used in the aerospace industry, but is prone to delamination, which is a major causes of failure. Structural Health Monitoring (SHM) systems need to be developed to determine the damage occurring within it. Our motivation is to design cost-effective new sensors and a data acquisition system for magnetostrictive structural health monitoring of aerospace composites using a simple RLC circuit. The developed system is tested on magnetostrictive FeSiB and CoSiB actuator ribbons using a bending rig. Our results show detectable sensitivity of inductors as low as 0.6 μH for a bending rig radii between 600 to 300 mm (equivalent to 0.8 to 1.7 mStrain), which show a strain sensitivity resolution of 0.01 μStrain (surface area: ~36 mm2). This value is at the detectability limit of our fabricated system. The best resolution (1.86 μStrain) was obtained from a 70-turn copper (~64 μH) wire inductor (surface area: ~400 mm2) that was paired with a FeSiB actuator.
- 14 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 55 (7) , 1-6
Magnetostrictive Sensors for Composite Damage Detection and Wireless Structural Health Monitoring
- 14 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 55 (7) , 1-6
Magnetostrictive Sensors for Composite Damage Detection and Wireless Structural Health Monitoring