Xinhua Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xinhua Li has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Kai Yang
Department of Radiology, Massachusetts General Hospital , Boston, MA 02114
9 shared publicationsBob Liu
Department of Radiology, Massachusetts General Hospital , Boston, MA 02114
8 shared publications- Bob Liu
Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts 02114
7 shared publications - Kai Yang
Department of Radiology Massachusetts General Hospital Boston Massachusetts USA
5 shared publications - Bob Liu
Division of Diagnostic Imaging Physics, Department of Radiology, Massachusetts General Hospital, Boston, MA, 02114, USA
4 shared publications Theodore A. Marschall
Division of Diagnostic Imaging Physics Department of Radiology Massachusetts General Hospital Boston Massachusetts USA
4 shared publications
Latest Publications
- 9 August 2025
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 98 (1175) , 1963-1969
Screening mammography a decade post-tomosynthesis: varied utilization of synthetic mammography across a large health system
Objectives: Digital breast tomosynthesis (DBT) with 2-dimensional acquisition (2D) was approved in 2011 for breast cancer screening in the United States. To reduce radiation dose to breasts, synthetic mammography (SM) was developed and approved to replace 2D with combo DBT in 2013. This retrospective study of screening practices in a large, incompletely integrated health system, assesses extent of SM utilization, and examines its impact on average glandular dose (AGD). Methods: Consecutive screening exams on 61 mammography systems at 9 hospitals from February 26 to March 12, 2023, were examined. Data collection included patient exams and radiation exposure. Comprehensive analysis included number of 2D acquisitions, 3-dimensional (3D) views, breast thickness, and AGD. Comparative assessments were made across the health system cohort and individual hospitals. Statistical analysis was performed using the R statistical software (version 4.3.2). Results: This study included 6849 screening exams on 13 484 breasts (thickness, 5.96 ± 1.47 cm) that received 3D views (13 482/13 484, or 99.99%) and 2D acquisitions (9459/13 484, or 70.15%). For average breast thickness (about 6 cm), mean AGD per breast was 0.29-5.32 mGy (2D only), 4-6.1 mGy (3D only), and 5.5-9.94 mGy (2D/3D). Three hospitals preferentially used SM (81.3%-93.5% of breasts). For an average breast, the ratio of mean AGD(3D) without 2D acquisitions to mean AGD(3D + 2D) with 2D acquisitions was 0.589 (95% CI: 0.561-0.619), 0.625 (0.563-0.702), and 0.588 (0.508-0.696), respectively. Conclusions: SM reduces AGD. There is a need to review recurring screening mammographic exams, and optimize patient doses by adopting SM, where it meets the clinic’s requirements. Advances in knowledge: SM reduces AGD by 36.5%, but only 3 of 9 hospitals within the same large health system have adopted this technology. Breast centres should consider reviewing their imaging protocols to optimize radiation doses for patients undergoing annual screening mammography with SM.
- 9 August 2025
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 98 (1175) , 1963-1969
Screening mammography a decade post-tomosynthesis: varied utilization of synthetic mammography across a large health system
Objectives: Digital breast tomosynthesis (DBT) with 2-dimensional acquisition (2D) was approved in 2011 for breast cancer screening in the United States. To reduce radiation dose to breasts, synthetic mammography (SM) was developed and approved to replace 2D with combo DBT in 2013. This retrospective study of screening practices in a large, incompletely integrated health system, assesses extent of SM utilization, and examines its impact on average glandular dose (AGD). Methods: Consecutive screening exams on 61 mammography systems at 9 hospitals from February 26 to March 12, 2023, were examined. Data collection included patient exams and radiation exposure. Comprehensive analysis included number of 2D acquisitions, 3-dimensional (3D) views, breast thickness, and AGD. Comparative assessments were made across the health system cohort and individual hospitals. Statistical analysis was performed using the R statistical software (version 4.3.2). Results: This study included 6849 screening exams on 13 484 breasts (thickness, 5.96 ± 1.47 cm) that received 3D views (13 482/13 484, or 99.99%) and 2D acquisitions (9459/13 484, or 70.15%). For average breast thickness (about 6 cm), mean AGD per breast was 0.29-5.32 mGy (2D only), 4-6.1 mGy (3D only), and 5.5-9.94 mGy (2D/3D). Three hospitals preferentially used SM (81.3%-93.5% of breasts). For an average breast, the ratio of mean AGD(3D) without 2D acquisitions to mean AGD(3D + 2D) with 2D acquisitions was 0.589 (95% CI: 0.561-0.619), 0.625 (0.563-0.702), and 0.588 (0.508-0.696), respectively. Conclusions: SM reduces AGD. There is a need to review recurring screening mammographic exams, and optimize patient doses by adopting SM, where it meets the clinic’s requirements. Advances in knowledge: SM reduces AGD by 36.5%, but only 3 of 9 hospitals within the same large health system have adopted this technology. Breast centres should consider reviewing their imaging protocols to optimize radiation doses for patients undergoing annual screening mammography with SM.
- 20 March 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 12 (S2) , 1-13
Frequency-based texture analysis of non-Gaussian properties of digital breast tomosynthesis images and comparison across two vendors
PurposeWe aim to analyze higher-order textural components of digital breast tomosynthesis (DBT) images to quantify differences in the appearance of breast parenchyma produced by different vendors.ApproachWe included consecutive women who had normal screening DBT exams in January 2018 from a GE system and in adjacent years from Hologic systems. Laplacian fractional entropy (LFE), as a measure of non-Gaussian statistical properties of breast tissue texture, was calculated from for-presentation Craniocaudal (CC) view DBT slices and synthetic mammograms (SMs) through frequency-based filtering with Gabor filters, which were considered mathematical models for human visual response to image textures. The LFE values were compared within and across subjects and vendors along with secondary parameters (laterality, year-to-year, modality, and breast density) via two-way analysis of variance (ANOVA) tests using frequency as one of the two independent variables, and a P-value <0.05 was considered statistically significant.ResultsA total of 8529 CC view DBT slices and SM images from 73 screening exams in 25 women were analyzed. Significant differences in LFE were observed for different frequencies (P<0.001) and across vendors (GE versus Hologic DBT: P<0.001, GE versus Hologic SM: P<0.001).ConclusionSignificant differences in perception of breast parenchyma textures among two DBT vendors were demonstrated via higher-order non-Gaussian statistical properties. This finding extends previously observed differences in anatomical noise power spectra in DBT images and provides quantitative evidence to support caution in across-vendor comparative reading and will be beneficial to facilitate future development of vendor-neutral artificial intelligence algorithms for breast cancer screening.
- 20 March 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 12 (S2) , 1-13
Frequency-based texture analysis of non-Gaussian properties of digital breast tomosynthesis images and comparison across two vendors
PurposeWe aim to analyze higher-order textural components of digital breast tomosynthesis (DBT) images to quantify differences in the appearance of breast parenchyma produced by different vendors.ApproachWe included consecutive women who had normal screening DBT exams in January 2018 from a GE system and in adjacent years from Hologic systems. Laplacian fractional entropy (LFE), as a measure of non-Gaussian statistical properties of breast tissue texture, was calculated from for-presentation Craniocaudal (CC) view DBT slices and synthetic mammograms (SMs) through frequency-based filtering with Gabor filters, which were considered mathematical models for human visual response to image textures. The LFE values were compared within and across subjects and vendors along with secondary parameters (laterality, year-to-year, modality, and breast density) via two-way analysis of variance (ANOVA) tests using frequency as one of the two independent variables, and a P-value <0.05 was considered statistically significant.ResultsA total of 8529 CC view DBT slices and SM images from 73 screening exams in 25 women were analyzed. Significant differences in LFE were observed for different frequencies (P<0.001) and across vendors (GE versus Hologic DBT: P<0.001, GE versus Hologic SM: P<0.001).ConclusionSignificant differences in perception of breast parenchyma textures among two DBT vendors were demonstrated via higher-order non-Gaussian statistical properties. This finding extends previously observed differences in anatomical noise power spectra in DBT images and provides quantitative evidence to support caution in across-vendor comparative reading and will be beneficial to facilitate future development of vendor-neutral artificial intelligence algorithms for breast cancer screening.
- 23 March 2024
- Published by Elsevier in Physica Medica
- Vol. 120, 103330
Impact of equipment technology on reference levels in fluoroscopy-guided gastrointestinal procedures
- 23 March 2024
- Published by Elsevier in Physica Medica
- Vol. 120, 103330
Impact of equipment technology on reference levels in fluoroscopy-guided gastrointestinal procedures
- 29 February 2024
- Published by Wiley in Medical Physics
- Vol. 51 (4) , 2461-2467
Technical note: Workload and transmission data for mobile C‐arm fluoroscopy in gastrointestinal endoscopy
Background: Mobile C‐arms may be used in fixed locations, and it is recommended that qualified experts evaluate structural shielding.Purpose: To assess clinical workload distributions for mobile C‐arms used in gastrointestinal endoscopy and determine the Archer equation parameters for the C‐arm beam spectra.Methods: Consecutive (30 months) gastrointestinal endoscopic procedures on two Cios Alpha systems (Siemens) were retrospectively analyzed. X‐ray tube voltage, tube current‐time product, reference point air kerma (Ka,r), air kerma‐area product (PKA), and fluoroscopic time were examined. The primary beam half‐value layer (HVL) was measured with an ionization chamber and aluminum 1100 plates. Stray radiation fraction at 1 m from a scattering source (ACR R/F phantom) was directly measured. Monte Carlo (Geant4) simulation was performed to calculate the transmission of broad X‐ray beams through lead, concrete, gypsum, and steel, with X‐ray HVLs matching those of the C‐arm X‐ray beam. The transmission data were fitted to the Archer equation.Results: The number of procedures (3509) was equivalent to 13.48 procedures per room per week. Dose quantities were 54.8 mGy (Ka,r), 18.3 Gy∙cm2 (PKA), and 7.8 min (fluoroscopic time) per procedure. X‐ray beam irradiation events were recorded for 2906 (82.8%) procedures with 160,009 events, whose mA‐minute weighted tube voltage was 91.0 kV and the workload was 0.68 mA‐minute per procedure. The two rooms had a significant difference in the number of procedures per week, 17.3 (29) [mean (maximum)] and 9.6 (16), respectively. The stray radiation fraction was 9.7×10−4 (80 kV) and 1.25×10−3 (120 kV). Transmission fitting parameters were provided for the tube voltage (on average, 90 kV; high end, 120 kV) of the C‐arm.Conclusions: This work provides workload and transmission data for mobile C‐arm fluoroscopy in gastrointestinal endoscopy, which indicates a need for structural shielding evaluation of the procedure rooms.
- 29 February 2024
- Published by Wiley in Medical Physics
- Vol. 51 (4) , 2461-2467
Technical note: Workload and transmission data for mobile C‐arm fluoroscopy in gastrointestinal endoscopy
Background: Mobile C‐arms may be used in fixed locations, and it is recommended that qualified experts evaluate structural shielding.Purpose: To assess clinical workload distributions for mobile C‐arms used in gastrointestinal endoscopy and determine the Archer equation parameters for the C‐arm beam spectra.Methods: Consecutive (30 months) gastrointestinal endoscopic procedures on two Cios Alpha systems (Siemens) were retrospectively analyzed. X‐ray tube voltage, tube current‐time product, reference point air kerma (Ka,r), air kerma‐area product (PKA), and fluoroscopic time were examined. The primary beam half‐value layer (HVL) was measured with an ionization chamber and aluminum 1100 plates. Stray radiation fraction at 1 m from a scattering source (ACR R/F phantom) was directly measured. Monte Carlo (Geant4) simulation was performed to calculate the transmission of broad X‐ray beams through lead, concrete, gypsum, and steel, with X‐ray HVLs matching those of the C‐arm X‐ray beam. The transmission data were fitted to the Archer equation.Results: The number of procedures (3509) was equivalent to 13.48 procedures per room per week. Dose quantities were 54.8 mGy (Ka,r), 18.3 Gy∙cm2 (PKA), and 7.8 min (fluoroscopic time) per procedure. X‐ray beam irradiation events were recorded for 2906 (82.8%) procedures with 160,009 events, whose mA‐minute weighted tube voltage was 91.0 kV and the workload was 0.68 mA‐minute per procedure. The two rooms had a significant difference in the number of procedures per week, 17.3 (29) [mean (maximum)] and 9.6 (16), respectively. The stray radiation fraction was 9.7×10−4 (80 kV) and 1.25×10−3 (120 kV). Transmission fitting parameters were provided for the tube voltage (on average, 90 kV; high end, 120 kV) of the C‐arm.Conclusions: This work provides workload and transmission data for mobile C‐arm fluoroscopy in gastrointestinal endoscopy, which indicates a need for structural shielding evaluation of the procedure rooms.
- 1 December 2023
- Published by Elsevier in Physica Medica
- Vol. 117, 103180
Neurointerventions on two generations of angiography systems: Recent systems reduce radiation exposure by half
- 1 December 2023
- Published by Elsevier in Physica Medica
- Vol. 117, 103180
Neurointerventions on two generations of angiography systems: Recent systems reduce radiation exposure by half
- 13 November 2023
- Published by Springer Nature in European Radiology
- Vol. 34 (6) , 3719-3729
Cumulative radiation exposure from multimodality recurrent imaging of CT, fluoroscopically guided intervention, and nuclear medicine
Objectives To assess cumulative effective dose (CED) over a 4-year period in patients undergoing multimodality recurrent imaging at a major hospital in the USA. Methods CED from CT, fluoroscopically guided intervention (FGI), and nuclear medicine was analyzed in consecutive exams in a tertiary care center in 2018–2021. Patients with CED ≥ 100 mSv were classified by age and body habitus (underweight, healthy weight, overweight, obese), as per body mass index percentiles < 5th, 5th to < 85th, 85th to < 95th, and ≥ 95th (age 2–19 years), and its ranges < 18.5, 18.5–24.9, 25–29.9, and ≥ 30 (≥ 20 years), respectively. Results Among a total of 205,425 patients, 5.7% received CED ≥ 100 mSv (mean 184 mSv, maximum 1165 mSv) and their ages were mostly 50–64 years (34.1%), followed by 65–74 years (29.8%), ≥ 75 years (19.5%), 20–49 years (16.3%), and ≤ 19 years (0.29%). Body habitus in decreasing occurrence was obese (38.6%), overweight (31.9%), healthy weight (27.5%), and underweight (2.1%). Classification by dose indicated 172 patients (≥ 500 mSv) and 3 (≥ 1000 mSv). In comparison, 5.3% of 189,030 CT patients, 1.6% of 18,963 FGI patients, and 0.19% of 41,401 nuclear-medicine patients received CED ≥ 100 mSv from a single modality. Conclusions The study of total dose from CT, FGI, and nuclear medicine of patients with CED ≥ 100 mSv indicates major (89%) contribution of CT to CED with 70% of cohort being obese and overweight, and 64% of cohort aged 50–74 years. Clinical relevance statement Multimodality recurrent exams are common and there is a lack of information on patient cumulative radiation exposure. This study attempts to address this lacuna and has the potential to motivate actions to improve the justification process for enhancing patient safety. Key Points • In total, 5.7% of patients undergoing multimodality recurrent imaging (CT, fluoroscopically guided intervention, nuclear medicine) incurred a dose of ≥ 100 mSv. • Mean dose was 184 mSv, with 15 to 18 times contribution from CT than that from fluoroscopically guided intervention or nuclear medicine. • In total, 70% of those who received ≥ 100mSv were either overweight or obese.
- 13 November 2023
- Published by Springer Nature in European Radiology
- Vol. 34 (6) , 3719-3729
Cumulative radiation exposure from multimodality recurrent imaging of CT, fluoroscopically guided intervention, and nuclear medicine
Objectives To assess cumulative effective dose (CED) over a 4-year period in patients undergoing multimodality recurrent imaging at a major hospital in the USA. Methods CED from CT, fluoroscopically guided intervention (FGI), and nuclear medicine was analyzed in consecutive exams in a tertiary care center in 2018–2021. Patients with CED ≥ 100 mSv were classified by age and body habitus (underweight, healthy weight, overweight, obese), as per body mass index percentiles < 5th, 5th to < 85th, 85th to < 95th, and ≥ 95th (age 2–19 years), and its ranges < 18.5, 18.5–24.9, 25–29.9, and ≥ 30 (≥ 20 years), respectively. Results Among a total of 205,425 patients, 5.7% received CED ≥ 100 mSv (mean 184 mSv, maximum 1165 mSv) and their ages were mostly 50–64 years (34.1%), followed by 65–74 years (29.8%), ≥ 75 years (19.5%), 20–49 years (16.3%), and ≤ 19 years (0.29%). Body habitus in decreasing occurrence was obese (38.6%), overweight (31.9%), healthy weight (27.5%), and underweight (2.1%). Classification by dose indicated 172 patients (≥ 500 mSv) and 3 (≥ 1000 mSv). In comparison, 5.3% of 189,030 CT patients, 1.6% of 18,963 FGI patients, and 0.19% of 41,401 nuclear-medicine patients received CED ≥ 100 mSv from a single modality. Conclusions The study of total dose from CT, FGI, and nuclear medicine of patients with CED ≥ 100 mSv indicates major (89%) contribution of CT to CED with 70% of cohort being obese and overweight, and 64% of cohort aged 50–74 years. Clinical relevance statement Multimodality recurrent exams are common and there is a lack of information on patient cumulative radiation exposure. This study attempts to address this lacuna and has the potential to motivate actions to improve the justification process for enhancing patient safety. Key Points • In total, 5.7% of patients undergoing multimodality recurrent imaging (CT, fluoroscopically guided intervention, nuclear medicine) incurred a dose of ≥ 100 mSv. • Mean dose was 184 mSv, with 15 to 18 times contribution from CT than that from fluoroscopically guided intervention or nuclear medicine. • In total, 70% of those who received ≥ 100mSv were either overweight or obese.
- 5 January 2023
- Published by Elsevier in Physica Medica
- Vol. 106, 102521
Patient follow-up for possible radiation injury from fluoroscopically-guided interventions: Need to consider high cumulative exposure from multiple procedures
- 5 January 2023
- Published by Elsevier in Physica Medica
- Vol. 106, 102521
Patient follow-up for possible radiation injury from fluoroscopically-guided interventions: Need to consider high cumulative exposure from multiple procedures
- 9 November 2022
- Published by Springer Nature in European Radiology
- Vol. 33 (4) , 2439-2449
CT image quality evaluation in the age of deep learning: trade-off between functionality and fidelity
Objective To quantitatively compare DLIR and ASiR-V with realistic anatomical images. Methods CT scans of an anthropomorphic phantom were acquired using three routine protocols (brain, chest, and abdomen) at four dose levels, with images reconstructed at five levels of ASiR-V and three levels of DLIR. Noise power spectrum (NPS) was estimated using a difference image by subtracting two matching images from repeated scans. Using the max-dose FBP reconstruction as the ground truth, the structure similarity index (SSIM) and gradient magnitude (GM) of difference images were evaluated. Image noise magnitude (σ), frequency location of the NPS peak (fpeak), mean SSIM (MSSIM), and mean GM (MGM) were used as quantitative metrics to compare image quality, for each anatomical region, protocol, algorithm, dose level, and slice thickness. Results Image noise had a strong (R2 > 0.99) power law relationship with dose for all algorithms. For the abdomen and chest, fpeak shifted from 0.3 (FBP) down to 0.15 mm-1 (ASiR-V 100%) with increasing ASiR-V strength but remained 0.3 mm-1 for all DLIR levels. fpeak shifted down for the brain protocol with increasing DLIR levels. Three levels of DLIR produced similar image noise levels as ASiR-V 40%, 80%, and 100%, respectively. DLIR had lower MSSIM but higher MGM than ASiR-V while matching imaging noise. Conclusion Compared to ASiR-V, DLIR presents trade-offs between functionality and fidelity: it has a noise texture closer to FBP and more edge enhancement, but reduced structure similarity. These trade-offs and unique protocol-dependent behaviors of DLIR should be considered during clinical implementation and deployment. Key Points • DLIR reconstructed images demonstrate closer noise texture and lower structure similarity to FBP while producing equivalent noise levels comparable to ASiR-V. • DLIR has additional edge enhancement as compared to ASiR-V. • DLIR has unique protocol-dependent behaviors that should be considered for clinical implementation.
- 9 November 2022
- Published by Springer Nature in European Radiology
- Vol. 33 (4) , 2439-2449
CT image quality evaluation in the age of deep learning: trade-off between functionality and fidelity
Objective To quantitatively compare DLIR and ASiR-V with realistic anatomical images. Methods CT scans of an anthropomorphic phantom were acquired using three routine protocols (brain, chest, and abdomen) at four dose levels, with images reconstructed at five levels of ASiR-V and three levels of DLIR. Noise power spectrum (NPS) was estimated using a difference image by subtracting two matching images from repeated scans. Using the max-dose FBP reconstruction as the ground truth, the structure similarity index (SSIM) and gradient magnitude (GM) of difference images were evaluated. Image noise magnitude (σ), frequency location of the NPS peak (fpeak), mean SSIM (MSSIM), and mean GM (MGM) were used as quantitative metrics to compare image quality, for each anatomical region, protocol, algorithm, dose level, and slice thickness. Results Image noise had a strong (R2 > 0.99) power law relationship with dose for all algorithms. For the abdomen and chest, fpeak shifted from 0.3 (FBP) down to 0.15 mm-1 (ASiR-V 100%) with increasing ASiR-V strength but remained 0.3 mm-1 for all DLIR levels. fpeak shifted down for the brain protocol with increasing DLIR levels. Three levels of DLIR produced similar image noise levels as ASiR-V 40%, 80%, and 100%, respectively. DLIR had lower MSSIM but higher MGM than ASiR-V while matching imaging noise. Conclusion Compared to ASiR-V, DLIR presents trade-offs between functionality and fidelity: it has a noise texture closer to FBP and more edge enhancement, but reduced structure similarity. These trade-offs and unique protocol-dependent behaviors of DLIR should be considered during clinical implementation and deployment. Key Points • DLIR reconstructed images demonstrate closer noise texture and lower structure similarity to FBP while producing equivalent noise levels comparable to ASiR-V. • DLIR has additional edge enhancement as compared to ASiR-V. • DLIR has unique protocol-dependent behaviors that should be considered for clinical implementation.
- 7 September 2022
- Published by Wiley in Medical Physics
- Vol. 50 (2) , 1096-1104
Calculation of scan length and size‐specific dose at longitudinal positions of body CT scans using dose equilibrium function
Background Dose evaluation at longitudinal positions of body computed tomography (CT) scans is useful for CT quality assurance programs and patient organ dose evaluation. Accurate estimates depend on both patient size and scan length. Purpose To propose practical evaluation of the average dose to the transverse slab of an axial image slice for adult body CT examinations, considering not only patient size but also scan length, and to compare the results with those of Monte Carlo (Geant4) simulation [D-sim(z)] and size-specific dose estimates at longitudinal positions of scans [SSDE(z)] from international standards (IEC publication no. 62985). Methods In a scan series, the total dose at each z-axis location was calculated using the input information identical to the SSDE(z) evaluation. Each axial image slice (slice thickness, 2.5 or 5 mm) was first considered independently. Its z-axis coverage and CTDIvol (from the DICOM headers) were used to directly calculate a z-axis dose profile for the average dose over the cross-section of a water phantom, using the approach to equilibrium function. The phantom diameter was taken to be equal to the patient water equivalent diameter at that slice. The above was repeated at all slices and the dose at each z-axis location was accumulated from all profiles, referred to as D-calc(z). For validation, we considered a cohort of 65 patients, who underwent chest and abdominopelvic examinations. The resultant D-calc(z) was compared with D-sim(z) and SSDE(z), both available in a previous paper. Results D-calc(z) evaluation could be used to accurately assess the scan range average dose, with an accuracy of 7.1%-8.7% for 65 patients in two examinations. On individual image slices, the maximum difference in magnitude between D-calc(z) and D-sim(z) [and between SSDE(z) and D-sim(z) in parentheses] was 37.5% (85%) [two edges (2 x 5 cm) of chest scan range], 17.8% (35.2%) (the remaining central region of chest scan), 26.8% (74.1%) [two edges (2 x 5 cm) of abdominopelvic scan range], and 14.2% (22.5%) (the remaining central region of abdominopelvic scan). Conclusions Identical input data are used for D-calc(z) and SSDE(z) evaluations. The latter is limited to the z-axis locations within scan range. At each image slice, SSDE(z) is equivalent to the midpoint dose of a fixed-mA scan of 15-30 cm (scan length). In contrast, D-calc(z) considers dose accumulation from varying scan length (from sub-centimeter to about 1 m) and tube current, and dose profile is also computed outside scan range. Besides greatly improving dose evaluation for individual image slices, D-calc(z) allows for evaluating dose accumulation from multiple series, which typically span different scan ranges. Our proposal may assist CT manufacturers and dose index monitoring software in assessing dose at longitudinal positions of body CT scans.
- 7 September 2022
- Published by Wiley in Medical Physics
- Vol. 50 (2) , 1096-1104
Calculation of scan length and size‐specific dose at longitudinal positions of body CT scans using dose equilibrium function
Background Dose evaluation at longitudinal positions of body computed tomography (CT) scans is useful for CT quality assurance programs and patient organ dose evaluation. Accurate estimates depend on both patient size and scan length. Purpose To propose practical evaluation of the average dose to the transverse slab of an axial image slice for adult body CT examinations, considering not only patient size but also scan length, and to compare the results with those of Monte Carlo (Geant4) simulation [D-sim(z)] and size-specific dose estimates at longitudinal positions of scans [SSDE(z)] from international standards (IEC publication no. 62985). Methods In a scan series, the total dose at each z-axis location was calculated using the input information identical to the SSDE(z) evaluation. Each axial image slice (slice thickness, 2.5 or 5 mm) was first considered independently. Its z-axis coverage and CTDIvol (from the DICOM headers) were used to directly calculate a z-axis dose profile for the average dose over the cross-section of a water phantom, using the approach to equilibrium function. The phantom diameter was taken to be equal to the patient water equivalent diameter at that slice. The above was repeated at all slices and the dose at each z-axis location was accumulated from all profiles, referred to as D-calc(z). For validation, we considered a cohort of 65 patients, who underwent chest and abdominopelvic examinations. The resultant D-calc(z) was compared with D-sim(z) and SSDE(z), both available in a previous paper. Results D-calc(z) evaluation could be used to accurately assess the scan range average dose, with an accuracy of 7.1%-8.7% for 65 patients in two examinations. On individual image slices, the maximum difference in magnitude between D-calc(z) and D-sim(z) [and between SSDE(z) and D-sim(z) in parentheses] was 37.5% (85%) [two edges (2 x 5 cm) of chest scan range], 17.8% (35.2%) (the remaining central region of chest scan), 26.8% (74.1%) [two edges (2 x 5 cm) of abdominopelvic scan range], and 14.2% (22.5%) (the remaining central region of abdominopelvic scan). Conclusions Identical input data are used for D-calc(z) and SSDE(z) evaluations. The latter is limited to the z-axis locations within scan range. At each image slice, SSDE(z) is equivalent to the midpoint dose of a fixed-mA scan of 15-30 cm (scan length). In contrast, D-calc(z) considers dose accumulation from varying scan length (from sub-centimeter to about 1 m) and tube current, and dose profile is also computed outside scan range. Besides greatly improving dose evaluation for individual image slices, D-calc(z) allows for evaluating dose accumulation from multiple series, which typically span different scan ranges. Our proposal may assist CT manufacturers and dose index monitoring software in assessing dose at longitudinal positions of body CT scans.
- 1 July 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1135) , 20211225
Patients undergoing multiple 18F-FDG PET/CT exams: Assessment of frequency, dose and disease classification
Objective: To analyse the frequency, demographics, primary disease and cumulative effective dose of patients undergoing two or more 18F-FDG PET/CT examinations in a year. Methods: In a retrospective study performed at a tertiary-care hospital, patients who underwent ≥2 18F-FDG PET/CT scans in a calendar year were identified for two consecutive years. The CT radiation dose was calculated using dose-length-product and sex-specific conversion factors. The primary malignancy of patients was retrieved from electronic medical records. Results: 10,714 18F-FDG PET/CT exams were performed for 6,831 unique patients in 2 years, yielding an average of 1.6 exams per patient. The maximum number of 18F-FDG PET/CT examinations any patient underwent in a single year was seven. 20.9% patients had ≥2 18F-FDG PET/CT exams in any single year. Thirty nine percent patients in the cohort were below 60 years age. The median dose for 18F-FDG PET/CT examination was 25.1 mSv and maximum value reaching 1.7 to 2.9 times the median value. Cumulative effective dose (CED) was≥100 mSv in 12–13% of the patients. The cumulative dose for both years combined demonstrated the 25th percentile, 50th percentile and 75th percentile as well as the mean to be over 100 mSv, with the 25th percentile being 109 mSv. The dominant primary malignancies contributing to serial 18F-FDG PET/CTs in decreasing frequency were melanoma, non-Hodgkin’s lymphoma (NHL), gastrointestinal cancer, breast cancer and Hodgkin’s lymphoma. Conclusions: A sizeable number of patients undergo≥2 18F-FDG PET/CT exams with one out of every eight patients receiving cumulative dose≥100 mSv and that includes patients with long-life expectancy. Advances in knowledge: The study found that one of five patients had≥2 18F-FDG PET/CT exams in a calendar year, one of four patients in two years and one of eight patients received cumulative dose≥100 mSv. Top malignancies associated with serial imaging in decreasing order of frequency included melanoma, non-Hodgkin’s lymphoma (NHL), gastrointestinal cancer, breast cancer and Hodgkin’s lymphoma.
- 1 July 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1135) , 20211225
Patients undergoing multiple 18F-FDG PET/CT exams: Assessment of frequency, dose and disease classification
Objective: To analyse the frequency, demographics, primary disease and cumulative effective dose of patients undergoing two or more 18F-FDG PET/CT examinations in a year. Methods: In a retrospective study performed at a tertiary-care hospital, patients who underwent ≥2 18F-FDG PET/CT scans in a calendar year were identified for two consecutive years. The CT radiation dose was calculated using dose-length-product and sex-specific conversion factors. The primary malignancy of patients was retrieved from electronic medical records. Results: 10,714 18F-FDG PET/CT exams were performed for 6,831 unique patients in 2 years, yielding an average of 1.6 exams per patient. The maximum number of 18F-FDG PET/CT examinations any patient underwent in a single year was seven. 20.9% patients had ≥2 18F-FDG PET/CT exams in any single year. Thirty nine percent patients in the cohort were below 60 years age. The median dose for 18F-FDG PET/CT examination was 25.1 mSv and maximum value reaching 1.7 to 2.9 times the median value. Cumulative effective dose (CED) was≥100 mSv in 12–13% of the patients. The cumulative dose for both years combined demonstrated the 25th percentile, 50th percentile and 75th percentile as well as the mean to be over 100 mSv, with the 25th percentile being 109 mSv. The dominant primary malignancies contributing to serial 18F-FDG PET/CTs in decreasing frequency were melanoma, non-Hodgkin’s lymphoma (NHL), gastrointestinal cancer, breast cancer and Hodgkin’s lymphoma. Conclusions: A sizeable number of patients undergo≥2 18F-FDG PET/CT exams with one out of every eight patients receiving cumulative dose≥100 mSv and that includes patients with long-life expectancy. Advances in knowledge: The study found that one of five patients had≥2 18F-FDG PET/CT exams in a calendar year, one of four patients in two years and one of eight patients received cumulative dose≥100 mSv. Top malignancies associated with serial imaging in decreasing order of frequency included melanoma, non-Hodgkin’s lymphoma (NHL), gastrointestinal cancer, breast cancer and Hodgkin’s lymphoma.