KYKai Yang

Kai Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kai Yang has a total of 141 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Quantifying variation in DLP‐ to‐ effective‐dose conversion factors in CT using a Monte Carlo‐based dose‐estimation software

    by Jelena M. Mihailovic, Renxin Chu, Da Zhang, Andrew M. Hernandez, Kai Yang, Lifeng Yu

    Background: A common method to estimate the effective dose in CT is to multiply the dose length product in a CT scan by a conversion factor (k). The k‐factors are determined by dividing the effective dose (calculated using a weighted summation of organ doses) by the dose length product (DLP) for specific digital phantoms. The k‐factors determined in this way may vary substantially depending on the effective dose calculation methods and phantom models used. Purpose: The purpose of this study was to estimate variation associated with different acquisition and patient characteristics in the quantification of k‐factors. Methods: K‐factors were calculated using VirtualDoseCT for a diverse set of computational phantoms representing different patient models, scanner models, and seven CT exams. The tube potential varied from 80 to 120 kV. The scan length was varied by ± 5 cm relative to the default setting. The CTDIvol was set to 10 mGy when tube current modulation was not used; otherwise, the software default was used. A multivariable regression method was employed to derive an empirical formula for k‐factors, along with model‐uncertainty analysis and Sobol's sensitivity analysis to identify the influence of each variable. Results: K‐factors for all exams increased with kV. Negative dependence of k‐factors on BMI was observed, with lower values in males than in females. Moderate to high variation was observed in the quantification of k‐factors without TCM, which remained unchanged with TCM. Based on Sobol's indices (0.8–1), k‐factors were influenced most by scan length and patient size for adults, and scan length and age for pediatric phantoms. Discussion: The study showed that a large spread in k‐factors was predominantly influenced by scan length, patient size and age. The heterogeneity in k‐factors may lead to large heterogeneity in the effective dose estimate if the DLP×k method is used. These results indicate that age and size specific k‐factors to estimate effective dose from DLP may be warranted. Conclusions: A set of k‐factors should be established to account for these factors and improve effective dose estimations.

  • Cumulative dose in pediatric CT “frequent flyers”: cohort results and risk review

    by Sjirk J Westra, Andrew E Ferretti, Theodore A Marschall, Xinhua Li, Kai Yang, Bob Liu, Madan M Rehani

    Background Published surveys have documented increasing cumulative radiation doses from the increased use of CT over recent decades, but pediatric data on this are sparse. Objective To determine what percentage of pediatric patients receive a high cumulative effective dose (CED) from repeated CT scans in our practice, and to examine the reasons for this. Materials and methods Our dose monitoring software maintains a record of CED in all patients undergoing CT. Those who received a CED ≥50 mSv and ≥100 mSv were tabulated for further analysis. The highest dose outliers were flagged for analysis of clinical rationales of CT use, calculation of cumulative absorbed dose profiles, and outcomes. Results From 2013-2023, we performed CT in 10,199 patients aged 0-19 years, of whom 75% had one, 14% had two, 5% had three, 3% had four, and 3% had five or more CTs. Of our cohort, 97 (0.95%) reached the CED dose threshold of 50 mSv at age 16.0±3.0 (16.9) years [mean±SD (median)], and 20 (0.20%) also reached the 100 mSv threshold at age 16.2±1.8 (16.5) years. The highest CED values occurred in patients with serious and catastrophic conditions, in overweight adolescents, and because of repeated high-dose multiphasic acquisitions and CT-guided interventions. Conclusion Most of our patients (89%) had only 1-2 CT scans. Although only 0.95% and 0.20% of our pediatric patients experienced CEDs more than 50 mSv and 100 mSv (respectively) from repeated CT scans, these groups deserve close attention, as they often continue to accumulate doses throughout childhood and beyond. Graphical abstract


  • Open Access

    Comparing energy-integrating detector and photon-counting detector-based breast cone beam CTs for microcalcification detection via Monte Carlo simulation

    by Ahad Ollah Ezzati, Xiaoyu Hu, Miao Qi, Youfang Lai, Yuncheng Zhong, Kai Yang, Xun Jia

    Objective. Microcalcification ( µ Calc) detection plays an important role in breast cancer screening. Electronic noise in energy-integrating detectors (EIDs) is the major challenge for this task in current breast cone-beam CT (bCBCT) due to the tight dose constraint for breast imaging. bCBCT with a photon counting detector (PCD) can potentially offer a higher spatial resolution and lower noise. This study performed a direct comparison of bCBCTs with the two detector types via GPU-based Monte Carlo (MC) simulation. Approach. We employed Virtual Clinical Trial for Regulatory Evaluation toolkit to generate a realistic breast phantom with a 0.25 mm 3 voxel size, 80% fat fraction and 14 cm diameter. We considered a bCBCT system with a 60 kV x-ray source filtered with 0.3 mm Cu and detector response functions for PCD and EID. A total of 360 projections were simulated with a total number of 3.15 × 10 12 photons, corresponding to ∼4 mGy mean glandular dose, comparable to a two-view mammography. We modified our GPU-based MC simulation code to incorporate analytical descriptions of µ Calcs of spherical shapes with diameters ranging from 0.1 to 0.4 mm, in 0.1 mm increments, into the voxelized phantom. A nichrome wire with 0.07 mm diameter was simulated to calculate the modulation transfer functions (MTFs). bCBCT images were reconstructed with the Feldkamp–Davis–Kress algorithm, and image quality and µ Calc detection performance were evaluated. Main results. EID-bCBCT had more profound image noise due to electronic noise. The image intensity standard deviations estimated within a region of interest were 0.055 cm −1 for EID-bCBCT and 0.038 cm −1 for PCD-bCBCT, respectively. µ Calcs and breast anatomy such as ligaments were more visible in the PCD-bCBCT images. The 10% MTF cutoffs were 5.5 and 9.5 lp mm −1 for EID-bCBCT and PCD-bCBCT, respectively. Contrast-to-noise ratio ranged in 1.20–9.13 for EID-bCBCT and 3.07–14.74 for PCD-bCBCT, depending on µ Calc sizes. Significance. We compared EID- and PCD-based bCBCT for µ Calc detection using GPU-based MC simulations in a clinically realistic setting. Our results demonstrate a potential advantage of PCD-bCBCT for this detection task.

  • Head-to-head comparison of analog-filament vs a digital-CNT x-ray sources: a paradigm shift in radiology

    by Yile Fang, Amar Prasad Gupta, Matthew Tivnan, Jake Hecla, Darash Desai, Dufan Wu, Kai Yang, Tim Moulton, Wolfgang Krull, Rajiv Gupta

    X-ray imaging has advanced significantly with the adoption of digital detectors; however, the x-ray sources themselves have remained largely unchanged, relying on conventional analog-filament tubes. The emergence of digital-CNT x-ray sources introduces a paradigm shift by offering lower energy consumption, enhanced dose control, and improved operational stability. This study provides a head-to-head comparison between analog-filament and digital-CNT x-ray sources by evaluating their power efficiency, radiation dose output, current stability, image quality, and environmental impact. Our results reveal that digital-CNT x-ray sources are 75% smaller in volume and 50% lighter than analog-filament tubes, contributing to easier integration into portable imaging systems. Furthermore, energy consumption analysis shows that digital-CNT sources require 17% less power to produce equivalent x-ray output. Pulse dose measurements indicate a 40% reduction in radiation exposure with digital-CNT sources due to their precise digital switching capabilities. Image quality assessments, performed using cadaver hand and line phantom imaging, demonstrate that while both sources deliver comparable performance in standard imaging conditions, analog-filament tubes offer slightly superior spatial resolution at high magnifications because of their smaller electron emission area. Additionally, an environmental impact evaluation shows that the manufacturing process for digital-CNT tubes is more environmentally friendly compared to analog-filament tubes. These comprehensive findings highlight digital-CNT x-ray sources as a transformative technology poised to replace analog-filament systems in a wide range of clinical applications


  • Frequency-based texture analysis of non-Gaussian properties of digital breast tomosynthesis images and comparison across two vendors

    by Kai Yang, Craig K. Abbey, Bruno Barufaldi, Xinhua Li, Theodore A. Marschall, Bob Liu

    PurposeWe aim to analyze higher-order textural components of digital breast tomosynthesis (DBT) images to quantify differences in the appearance of breast parenchyma produced by different vendors.ApproachWe included consecutive women who had normal screening DBT exams in January 2018 from a GE system and in adjacent years from Hologic systems. Laplacian fractional entropy (LFE), as a measure of non-Gaussian statistical properties of breast tissue texture, was calculated from for-presentation Craniocaudal (CC) view DBT slices and synthetic mammograms (SMs) through frequency-based filtering with Gabor filters, which were considered mathematical models for human visual response to image textures. The LFE values were compared within and across subjects and vendors along with secondary parameters (laterality, year-to-year, modality, and breast density) via two-way analysis of variance (ANOVA) tests using frequency as one of the two independent variables, and a P-value <0.05 was considered statistically significant.ResultsA total of 8529 CC view DBT slices and SM images from 73 screening exams in 25 women were analyzed. Significant differences in LFE were observed for different frequencies (P<0.001) and across vendors (GE versus Hologic DBT: P<0.001, GE versus Hologic SM: P<0.001).ConclusionSignificant differences in perception of breast parenchyma textures among two DBT vendors were demonstrated via higher-order non-Gaussian statistical properties. This finding extends previously observed differences in anatomical noise power spectra in DBT images and provides quantitative evidence to support caution in across-vendor comparative reading and will be beneficial to facilitate future development of vendor-neutral artificial intelligence algorithms for breast cancer screening.


  • Optimizing energy threshold selection for low-concentration contrast agent quantification in small animal photon-counting CT

    by Xiaoyu Hu, Yuncheng Zhong, Xun Jia, Kai Yang

    Objective. Gold nanoparticles (GNPs) are widely used for biological research and applications. The in-vivo concentration of GNPs is usually low due to biological safety concerns, thus posing a challenge for imaging. This work investigates on optimal energy threshold selection in photon-counting detector(PCD)-based CT (PCCT) for the quantification of low-concentration GNPs. Approach. We derived the mathematical expression of the upper bound of the material decomposition error in the gold image. Comprehensive simulations were implemented for cylindrical phantom with inserts of different GNP concentrations. CT scans of this phantom were simulated with a 140 kVp x-ray beam under a realistic pre-clinical CT dose range. The PCD energy thresholds from 30 to 110 keV were enumerated for 2,3-channel PCCT and the optimal energy thresholds were determined by searching for the lowest decomposition error. Main results. The optimal energy threshold(s) to minimize the decomposition error in gold image was 44 keV for the 2-channel PCCT and { 34 , 40 } keV for the 3-channel case. Numerical results also validated the derived upper bounds of the decomposition error. Significance. This work addressed the need for selecting appropriate energy thresholds for accurate quantification of contrast agent distributions in pre-clinical PCCT. Both the analytical expression of the upper bound of material decomposition error and simulation results showed that the balanced consideration on photon counting noise levels and the numerical properties of the decomposition matrix is required in selecting the appropriate energy thresholds to achieve the most accurate material decomposition.


  • Preoperative Chest CT Myosteatosis Indicates Worse Postoperative Survival in Stage 0–IIB Non–Small Cell Lung Cancer

    by Lea Mantz, Nathaniel D. Mercaldo, Judit Simon, Philipp Kaess, Kai Yang, Anna-Sophia W. Dietrich, P. Erik Tonnesen, Amelie S. Troschel, J. Peter Marquardt, Daniel A. Sehi, et al.

    Myosteatosis markers at preoperative chest CT were associated with worse survival after resection of stage 0–IIB non–small cell lung cancer, independent of the skeletal muscle index and subcutaneous adipose tissue.


  • CT image quality evaluation in the age of deep learning: trade-off between functionality and fidelity

    by Kai Yang, Jinjin Cao, Nisanard Pisuchpen, Avinash Kambadakone, Rajiv Gupta, Theodore Marschall, Xinhua Li, Bob Liu

    Objective To quantitatively compare DLIR and ASiR-V with realistic anatomical images. Methods CT scans of an anthropomorphic phantom were acquired using three routine protocols (brain, chest, and abdomen) at four dose levels, with images reconstructed at five levels of ASiR-V and three levels of DLIR. Noise power spectrum (NPS) was estimated using a difference image by subtracting two matching images from repeated scans. Using the max-dose FBP reconstruction as the ground truth, the structure similarity index (SSIM) and gradient magnitude (GM) of difference images were evaluated. Image noise magnitude (σ), frequency location of the NPS peak (fpeak), mean SSIM (MSSIM), and mean GM (MGM) were used as quantitative metrics to compare image quality, for each anatomical region, protocol, algorithm, dose level, and slice thickness. Results Image noise had a strong (R2 > 0.99) power law relationship with dose for all algorithms. For the abdomen and chest, fpeak shifted from 0.3 (FBP) down to 0.15 mm-1 (ASiR-V 100%) with increasing ASiR-V strength but remained 0.3 mm-1 for all DLIR levels. fpeak shifted down for the brain protocol with increasing DLIR levels. Three levels of DLIR produced similar image noise levels as ASiR-V 40%, 80%, and 100%, respectively. DLIR had lower MSSIM but higher MGM than ASiR-V while matching imaging noise. Conclusion Compared to ASiR-V, DLIR presents trade-offs between functionality and fidelity: it has a noise texture closer to FBP and more edge enhancement, but reduced structure similarity. These trade-offs and unique protocol-dependent behaviors of DLIR should be considered during clinical implementation and deployment. Key Points • DLIR reconstructed images demonstrate closer noise texture and lower structure similarity to FBP while producing equivalent noise levels comparable to ASiR-V. • DLIR has additional edge enhancement as compared to ASiR-V. • DLIR has unique protocol-dependent behaviors that should be considered for clinical implementation.


  • Small animal photon counting cone-beam CT on a preclinical radiation research platform to improve radiation dose calculation accuracy

    by Xiaoyu Hu, Yuncheng Zhong, Youfang Lai, Chenyang Shen, Kai Yang, Xun Jia

    Objective. Cone beam CT (CBCT) in preclinical small animal irradiation platforms provides essential information for image guidance and radiation dose calculation for experiment planning. This project developed a photon-counting detector (PCD)-based multi(3)-energy (ME-)CBCT on a small animal irradiator to improve the accuracy of material differentiation and hence dose calculation, and compared to conventional flat panel detector (FPD)-based CBCT. Approach. We constructed a mechanical structure to mount a PCD to an existing preclinical irradiator platform and built a data acquisition pipeline to acquire x-ray projection data with a 100 kVp x-ray beam using three different energy thresholds in a single gantry rotation. We implemented an energy threshold optimization scheme to determine optimal thresholds to balance signal-to-noise ratios (SNRs) among energy channels. Pixel-based detector response calibration was performed to remove ring artifacts in reconstructed CBCT images. Feldkamp–Davis–Kress method was employed to reconstruct CBCT images and a total-variance regularization-based optimization model was used to decompose CBCT images into bone and water material images. We compared dose calculation results using PCD-based ME-CBCT with that of FPD-based CBCT. Main results. The optimal nominal energy thresholds were determined as 26, 56, and 90 keV, under which SNRs in a selected region-of-interest in the water region were 6.11, 5.91 and 5.93 in the three energy channels, respectively. Compared with dose calculation results using FPD-based CBCT, using PCD-based ME-CBCT reduced the mean relative error from 49.5% to 16.4% in bone regions and from 7.5% to 6.9% in soft tissue regions. Significance. PCD-based ME-CBCT is beneficial in improving radiation dose calculation accuracy in experiment planning of preclinical small animal irradiation researches.