Ruslan Hummatov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ruslan Hummatov has a total of 105 co-authors. Here are the top co-authors by number of shared publications:
- Antoine R. Miniussi
NASA Goddard Space Flight Center, Greenbelt, USA
5 shared publications - Kazuhiro Sakai
Center for Space Sciences and Technology, University of Maryland, Baltimore, MD, USA
5 shared publications - Caroline A. Kilbourne
NASA / Goddard Space Flight Center
4 shared publications - Fred Michael Finkbeiner
Sigma Space Corp./Hexagon US Federal, Lanham, MD, USA
4 shared publications - Stephen James Smith
NASA Goddard Space Flight Center (GSFC), Greenbelt, MD, USA
4 shared publications Daniel S. Swetz
National Institute of Standards and Technology, Boulder, USA
3 shared publications
Latest Publications
- Open Access
- 6 November 2024
- Published by Springer Nature in Communications Engineering
- Vol. 3 (1) , 1-9
Kinetic inductance current sensor for visible to near-infrared wavelength transition-edge sensor readout
Single-photon detectors based on the superconducting transition-edge sensor are used in a number of visible to near-infrared applications, particularly for photon-number-resolving measurements in quantum information science. To be practical for large-scale spectroscopic imaging or photonic quantum computing applications, the size of visible to near-infrared transition-edge sensor arrays and their associated readouts must be increased from a few pixels to many thousands. In this manuscript, we introduce the kinetic inductance current sensor, a scalable readout technology that exploits the nonlinear kinetic inductance in a superconducting resonator to make sensitive current measurements. Kinetic inductance current sensors can replace superconducting quantum interference devices for many applications because of their ability to measure fast, high slew-rate signals, their compatibility with standard microwave frequency-division multiplexing techniques, and their relatively simple fabrication. Here, we demonstrate the readout of a visible to near-infrared transition-edge sensor using a kinetic inductance current sensor with 3.7 MHz of bandwidth. We measure a readout noise of $$1.4\,{{{\rm{pA}}}}/\sqrt{{{{\rm{Hz}}}}}$$ , considerably below the detector noise at frequencies of interest, and an energy resolution of (0.137 ± 0.001) eV at 0.8 eV, comparable to resolutions observed with non-multiplexed superconducting quantum interference device readouts.- 6 November 2024
- Published by Springer Nature in Communications Engineering
- Vol. 3 (1) , 1-9
Open AccessKinetic inductance current sensor for visible to near-infrared wavelength transition-edge sensor readout
Single-photon detectors based on the superconducting transition-edge sensor are used in a number of visible to near-infrared applications, particularly for photon-number-resolving measurements in quantum information science. To be practical for large-scale spectroscopic imaging or photonic quantum computing applications, the size of visible to near-infrared transition-edge sensor arrays and their associated readouts must be increased from a few pixels to many thousands. In this manuscript, we introduce the kinetic inductance current sensor, a scalable readout technology that exploits the nonlinear kinetic inductance in a superconducting resonator to make sensitive current measurements. Kinetic inductance current sensors can replace superconducting quantum interference devices for many applications because of their ability to measure fast, high slew-rate signals, their compatibility with standard microwave frequency-division multiplexing techniques, and their relatively simple fabrication. Here, we demonstrate the readout of a visible to near-infrared transition-edge sensor using a kinetic inductance current sensor with 3.7 MHz of bandwidth. We measure a readout noise of $$1.4\,{{{\rm{pA}}}}/\sqrt{{{{\rm{Hz}}}}}$$ , considerably below the detector noise at frequencies of interest, and an energy resolution of (0.137 ± 0.001) eV at 0.8 eV, comparable to resolutions observed with non-multiplexed superconducting quantum interference device readouts. - Open Access
- 16 June 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 133 (23)
Fast transition-edge sensors suitable for photonic quantum computing
Photon-number resolving transition-edge sensors (TESs) with near unity system detection efficiency enable novel approaches to quantum computing, for example, heralding robust Gottesman–Kitaev–Preskill qubit states. Increasing the speed of the detectors increases the rate at which these states can be heralded. In addition, depending on the details of the scheme, faster detectors can reduce the complexities of the hardware implementation. In previous work, we demonstrated that adding a small amount of gold between the tungsten film and silicon substrate can increase thermal conductance and reduce detector recovery time. In that study, the readout electronics imposed limitations on stable biasing conditions of the TES detector, and the TES could only be biased at higher than ideal values. In this report, we demonstrate the operation of the TES illuminated by a heavily attenuated pulsed laser running at 1 MHz repetition rate and examine the limits to adding gold to speed up device recovery times using a higher bandwidth readout system. The best performance was achieved by combining a 15×15μm2 tungsten TES with 5μm3 of gold, which resulted in a recovery time faster than 250 ns, with an energy resolution of 0.25 eV full-width at half maximum at 0.8 eV photon energy.
- 16 June 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 133 (23)
Open AccessFast transition-edge sensors suitable for photonic quantum computing
Photon-number resolving transition-edge sensors (TESs) with near unity system detection efficiency enable novel approaches to quantum computing, for example, heralding robust Gottesman–Kitaev–Preskill qubit states. Increasing the speed of the detectors increases the rate at which these states can be heralded. In addition, depending on the details of the scheme, faster detectors can reduce the complexities of the hardware implementation. In previous work, we demonstrated that adding a small amount of gold between the tungsten film and silicon substrate can increase thermal conductance and reduce detector recovery time. In that study, the readout electronics imposed limitations on stable biasing conditions of the TES detector, and the TES could only be biased at higher than ideal values. In this report, we demonstrate the operation of the TES illuminated by a heavily attenuated pulsed laser running at 1 MHz repetition rate and examine the limits to adding gold to speed up device recovery times using a higher bandwidth readout system. The best performance was achieved by combining a 15×15μm2 tungsten TES with 5μm3 of gold, which resulted in a recovery time faster than 250 ns, with an energy resolution of 0.25 eV full-width at half maximum at 0.8 eV photon energy.
- 11 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-5
Mitigation of Finite Bandwidth Effects in Time-Division-Multiplexed SQUID Readout of TES Arrays
Time division multiplexing (TDM) is being developed as the readout technology of the X-ray integral field unit (X-IFU), a 3,168-pixel X-ray transition-edge sensor (TES) imaging spectrometer that is part of the European Space Agency's Athena satellite mission. Recent improvements in the low X-ray event count rate performance of TDM have been driven by increases in multiplexer bandwidth and the mitigation of settling transients. These methods and design changes have improved the 32-row multiplexed resolution of a NASA LPA 2.5a array from an initial (2.73 ± 0.03) eV to (1.97 ± 0.01) eV resolution at 5.9 keV. We discuss these recent advances in TDM readout, which have been implemented in an 8-column × 32-row spectrometer that will be deployed at the Lawrence Livermore National Laboratory electron beam ion trap (EBIT) facility, and present a model that will inform the design of future systems.
- 11 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-5
Mitigation of Finite Bandwidth Effects in Time-Division-Multiplexed SQUID Readout of TES Arrays
Time division multiplexing (TDM) is being developed as the readout technology of the X-ray integral field unit (X-IFU), a 3,168-pixel X-ray transition-edge sensor (TES) imaging spectrometer that is part of the European Space Agency's Athena satellite mission. Recent improvements in the low X-ray event count rate performance of TDM have been driven by increases in multiplexer bandwidth and the mitigation of settling transients. These methods and design changes have improved the 32-row multiplexed resolution of a NASA LPA 2.5a array from an initial (2.73 ± 0.03) eV to (1.97 ± 0.01) eV resolution at 5.9 keV. We discuss these recent advances in TDM readout, which have been implemented in an 8-column × 32-row spectrometer that will be deployed at the Lawrence Livermore National Laboratory electron beam ion trap (EBIT) facility, and present a model that will inform the design of future systems.
- 24 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-6
Performance of a Broad-Band, High-Resolution, Transition-Edge Sensor Spectrometer for X-ray Astrophysics
Future X-ray astrophysics experiments require multiplexed readout of high fill-factor, kilo-pixel arrays of transition-edge sensors (TESs), with very high spectral resolution over a broad range of energies. In this paper we report on a prototype kilo-pixel array of Mo/Au TESs readout with 8-column by 32-row time-division multiplexing (TDM). This system is being used to demonstrate the critical detector and readout technology for ESA's Athena X-IFU, and when complete will be used in laboratory astrophysics experiments. Our array and TDM readout have demonstrated a combined full-width-at-half-maximum energy resolution, including > 200 pixels, of: 1.95 eV for Ti-Kα (4.5 keV), 1.97 eV for Mn-Kα (5.9 keV), 2.16 eV for Co-Kα (6.9 keV), 2.33 eV for Cu-Kα (8 keV), 3.26 eV for Br-Kα (11.9 keV). The 1 sigma statistical errors are ≤0.01 eV for all spectra. These results meet the broad-band resolution requirements for X-IFU with margin.
- 24 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-6
Performance of a Broad-Band, High-Resolution, Transition-Edge Sensor Spectrometer for X-ray Astrophysics
Future X-ray astrophysics experiments require multiplexed readout of high fill-factor, kilo-pixel arrays of transition-edge sensors (TESs), with very high spectral resolution over a broad range of energies. In this paper we report on a prototype kilo-pixel array of Mo/Au TESs readout with 8-column by 32-row time-division multiplexing (TDM). This system is being used to demonstrate the critical detector and readout technology for ESA's Athena X-IFU, and when complete will be used in laboratory astrophysics experiments. Our array and TDM readout have demonstrated a combined full-width-at-half-maximum energy resolution, including > 200 pixels, of: 1.95 eV for Ti-Kα (4.5 keV), 1.97 eV for Mn-Kα (5.9 keV), 2.16 eV for Co-Kα (6.9 keV), 2.33 eV for Cu-Kα (8 keV), 3.26 eV for Br-Kα (11.9 keV). The 1 sigma statistical errors are ≤0.01 eV for all spectra. These results meet the broad-band resolution requirements for X-IFU with margin.
- 7 March 2020
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (1-2) , 393-400
Quantum Efficiency Study and Reflectivity Enhancement of Au/Bi Absorbers
- 7 March 2020
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (1-2) , 393-400
Quantum Efficiency Study and Reflectivity Enhancement of Au/Bi Absorbers
- Open Access
- 23 April 2019
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 125 (16) , 164503
Thermal fluctuation noise in Mo/Au superconducting transition-edge sensor microcalorimeters
In many superconducting transition-edge sensor (TES) microcalorimeters, the measured electrical noise exceeds theoretical estimates based on a thermal model of a single body thermally connected to a heat bath. Here, we report on noise and complex impedance measurements of a range of designs of TESs made with a Mo/Au bilayer. We have fitted the measured data using a two-body model, where the x-ray absorber and the TES are connected by an internal thermal conductance Gae. We find that the so-called excess noise measured in these devices is consistent with the noise generated from the internal thermal fluctuations between the x-ray absorber and the TES. Our fitted parameters are consistent with the origin of Gae being from the finite thermal conductance of the TES itself. These results suggest that even in these relatively low resistance Mo/Au TESs, the internal thermal conductance of the TES may add significant additional noise and could account for all the measured excess noise. Furthermore, we find that around regions of the superconducting transition with rapidly changing derivative of resistance with respect to temperature, an additional noise mechanism may dominate. These observations may lead to a greater understanding of TES devices and allow the design of TES microcalorimeters with improved performance.
- 23 April 2019
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 125 (16) , 164503
Open AccessThermal fluctuation noise in Mo/Au superconducting transition-edge sensor microcalorimeters
In many superconducting transition-edge sensor (TES) microcalorimeters, the measured electrical noise exceeds theoretical estimates based on a thermal model of a single body thermally connected to a heat bath. Here, we report on noise and complex impedance measurements of a range of designs of TESs made with a Mo/Au bilayer. We have fitted the measured data using a two-body model, where the x-ray absorber and the TES are connected by an internal thermal conductance Gae. We find that the so-called excess noise measured in these devices is consistent with the noise generated from the internal thermal fluctuations between the x-ray absorber and the TES. Our fitted parameters are consistent with the origin of Gae being from the finite thermal conductance of the TES itself. These results suggest that even in these relatively low resistance Mo/Au TESs, the internal thermal conductance of the TES may add significant additional noise and could account for all the measured excess noise. Furthermore, we find that around regions of the superconducting transition with rapidly changing derivative of resistance with respect to temperature, an additional noise mechanism may dominate. These observations may lead to a greater understanding of TES devices and allow the design of TES microcalorimeters with improved performance.
- Open Access
- 8 April 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 5 (02) , 021008-11
Multiabsorber transition-edge sensors for x-ray astronomy
Transition-edge sensors (TESs) are sensitive microcalorimeters under the development for a variety of applications in photon and particle spectroscopy.1,2 These devices consist of a thin superconducting film that is electrically biased in the highly temperature sensitive superconducting-to-normal transition region. Absorption of photon or particle energy causes a change in resistance of the sensor, which is measured as a current change by a superconducting quantum interference device (SQUID) ammeter. We are currently pursuing large format TES arrays3,4 to meet the requirements of proposed future x-ray astronomy missions.5,6 These applications require high fill-factor, kilo-pixel arrays capable of achieving full-width-half maximum (FWHM) energy resolution, , of typically a few electron volts in the energy range 0.3 to 10 keV. The maximum number of pixels used in TES arrays is constrained by a number of practical challenges. Position-sensitive microcalorimeters are an alternative approach that provides a means to increase the number of pixels within an array, at some compromise in performance, without the commensurate increase in the number of readout components, wires, and electrical connections. Although position-sensitive microcalorimeters have been investigated in a variety of different forms,7 8. 9. 10. – 11 our recent focus has been on the use of multiabsorber TESs commonly referred to as “hydras.”12,13 These devices consist of a series of individual x-ray absorbers with a different thermal conductance or “link” to a single TES. Each of these links acts as a thermal low-pass filter that gives rise to a different characteristic pulse shape for an x-ray absorbed in each pixel of the hydra. Thus these detectors can be used to provide larger focal plane coverage, or improved angular resolution for the same coverage, at some expense of performance (energy resolution and counting-rate) when compared to arrays of independent pixels. This type of detector has been proposed for a variety of different x-ray mission concepts over the past decade such as the international x-ray observatory (IXO).11,12 For IXO, the hydras were proposed as a way to increase the size of the focal-plane array around a core main array of single-pixel TESs and thus provide a greatly expanded instrument field-of-view (FOV) with only a limited increase in complexity. Results from prototype 4-pixel hydras have demonstrated to 6 eV at an x-ray energy of 5.9 keV for devices with a 0.25-mm absorber pitch.12,13- 8 April 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 5 (02) , 021008-11
Open AccessMultiabsorber transition-edge sensors for x-ray astronomy
Transition-edge sensors (TESs) are sensitive microcalorimeters under the development for a variety of applications in photon and particle spectroscopy.1,2 These devices consist of a thin superconducting film that is electrically biased in the highly temperature sensitive superconducting-to-normal transition region. Absorption of photon or particle energy causes a change in resistance of the sensor, which is measured as a current change by a superconducting quantum interference device (SQUID) ammeter. We are currently pursuing large format TES arrays3,4 to meet the requirements of proposed future x-ray astronomy missions.5,6 These applications require high fill-factor, kilo-pixel arrays capable of achieving full-width-half maximum (FWHM) energy resolution, , of typically a few electron volts in the energy range 0.3 to 10 keV. The maximum number of pixels used in TES arrays is constrained by a number of practical challenges. Position-sensitive microcalorimeters are an alternative approach that provides a means to increase the number of pixels within an array, at some compromise in performance, without the commensurate increase in the number of readout components, wires, and electrical connections. Although position-sensitive microcalorimeters have been investigated in a variety of different forms,7 8. 9. 10. – 11 our recent focus has been on the use of multiabsorber TESs commonly referred to as “hydras.”12,13 These devices consist of a series of individual x-ray absorbers with a different thermal conductance or “link” to a single TES. Each of these links acts as a thermal low-pass filter that gives rise to a different characteristic pulse shape for an x-ray absorbed in each pixel of the hydra. Thus these detectors can be used to provide larger focal plane coverage, or improved angular resolution for the same coverage, at some expense of performance (energy resolution and counting-rate) when compared to arrays of independent pixels. This type of detector has been proposed for a variety of different x-ray mission concepts over the past decade such as the international x-ray observatory (IXO).11,12 For IXO, the hydras were proposed as a way to increase the size of the focal-plane array around a core main array of single-pixel TESs and thus provide a greatly expanded instrument field-of-view (FOV) with only a limited increase in complexity. Results from prototype 4-pixel hydras have demonstrated to 6 eV at an x-ray energy of 5.9 keV for devices with a 0.25-mm absorber pitch.12,13 - 6 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
Extended Line Spread Function of TES Microcalorimeters With Au/Bi Absorbers
Microcalorimeters have the potential to provide line shapes well-described by a single Gaussian broadening term of few-eV width. This attribute makes the detectors especially well suited for x-ray astrophysics observations; however, lowlevel non-Gaussian broadening terms are expected and must be characterized. These terms depend on the composition of the xray absorber, the detailed x-ray absorption physics, the device thermalization processes, and the incident x-ray energy. Here we present the first measurements targeted at understanding the extended line-spread function (LSF) of x-ray microcalorimeter pixels under development for the X-ray Integral Field Unit (XIFU) on the Athena X-ray Observatory. These pixels are comprised of Mo/Au transition-edge sensors (TESs) with overhanging electroplated Au/Bi absorbers. We measured the line shapes using monochromatic x-ray sources with < 1 eV width at several xray energies (0.85, 0.93, 1.25, 1.5, 5.4, and 8.0 keV) across the instrument bandpass (0.3-12 keV) and modeled the line profiles. These results are compared to the extended LSF of the Hitomi microcalorimeter pixels that used HgTe absorbers.
- 6 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
Extended Line Spread Function of TES Microcalorimeters With Au/Bi Absorbers
Microcalorimeters have the potential to provide line shapes well-described by a single Gaussian broadening term of few-eV width. This attribute makes the detectors especially well suited for x-ray astrophysics observations; however, lowlevel non-Gaussian broadening terms are expected and must be characterized. These terms depend on the composition of the xray absorber, the detailed x-ray absorption physics, the device thermalization processes, and the incident x-ray energy. Here we present the first measurements targeted at understanding the extended line-spread function (LSF) of x-ray microcalorimeter pixels under development for the X-ray Integral Field Unit (XIFU) on the Athena X-ray Observatory. These pixels are comprised of Mo/Au transition-edge sensors (TESs) with overhanging electroplated Au/Bi absorbers. We measured the line shapes using monochromatic x-ray sources with < 1 eV width at several xray energies (0.85, 0.93, 1.25, 1.5, 5.4, and 8.0 keV) across the instrument bandpass (0.3-12 keV) and modeled the line profiles. These results are compared to the extended LSF of the Hitomi microcalorimeter pixels that used HgTe absorbers.
- 10 May 2018
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 193 (5-6) , 752-757
Fabrication of High-Resolution Gamma-Ray Metallic Magnetic Calorimeters with Ag:Er Sensor and Thick Electroplated Absorbers
- 10 May 2018
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 193 (5-6) , 752-757
Fabrication of High-Resolution Gamma-Ray Metallic Magnetic Calorimeters with Ag:Er Sensor and Thick Electroplated Absorbers
- Open Access
- 9 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 27 (4) , 1-5
Tantalum Passive Persistence Shunts for On-Chip Current Trapping in Metallic Magnetic Calorimetry
Ultrahigh resolution photon detectors based on metallic magnetic calorimeters (MMCs) employ a weakly magnetized paramagnetic sensor to measure the energy of the absorbed particles. MMCs can require large on-chip magnetizing currents of order ~100 mA to achieve optimal performance. To minimize noise injected from room-temperature current supplies, it is useful to trap these currents in on-chip persistent superconducting loops. These loops have so far used electrically heated persistent current switches. However, wire count can be reduced and design flexibility increased by using a passive superconducting persistent current switch with a T c intermediate between T c of the Nb loop and the operating temperature of the MMC. In addition, it is desirable for the T c of the switch to be above the regeneration temperature on singleshot adiabatic demagnetization refrigerators (ADRs). We present passive persistent current switch measurements obtained with Ta film grown on a 100 Å Nb base layer. We have demonstrated trapping of up to 150 mA with no evidence of flux creep over 20 h, and persistence of 100 mA trapped current through several regeneration cycles of our ADR with a regeneration temperature of ~2 K.
- 9 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 27 (4) , 1-5
Open AccessTantalum Passive Persistence Shunts for On-Chip Current Trapping in Metallic Magnetic Calorimetry
Ultrahigh resolution photon detectors based on metallic magnetic calorimeters (MMCs) employ a weakly magnetized paramagnetic sensor to measure the energy of the absorbed particles. MMCs can require large on-chip magnetizing currents of order ~100 mA to achieve optimal performance. To minimize noise injected from room-temperature current supplies, it is useful to trap these currents in on-chip persistent superconducting loops. These loops have so far used electrically heated persistent current switches. However, wire count can be reduced and design flexibility increased by using a passive superconducting persistent current switch with a T c intermediate between T c of the Nb loop and the operating temperature of the MMC. In addition, it is desirable for the T c of the switch to be above the regeneration temperature on singleshot adiabatic demagnetization refrigerators (ADRs). We present passive persistent current switch measurements obtained with Ta film grown on a 100 Å Nb base layer. We have demonstrated trapping of up to 150 mA with no evidence of flux creep over 20 h, and persistence of 100 mA trapped current through several regeneration cycles of our ADR with a regeneration temperature of ~2 K.