Masaya Takasaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Masaya Takasaki has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Keisuke Hasegawa
Department of Mechanical Science, Graduate School of Science and Engineering, Saitama University
3 shared publications - Hiroya Sugawara
Saitama University, Saitama, Japan
1 shared publication Masaya Fujimori
Department of Mechanical Engineering and System Design, Faculty of Engineering, Saitama University 2 , Saitama
1 shared publication- Mhia Md. Zaglul Shahadat
Rajshahi University of Engineering and Technology, Bangladesh
1 shared publication - Nahina Islam
Central Queensland University
1 shared publication - Syed Mamun R. Rasid
Rajshahi University of Engineering and Technology
1 shared publication
Latest Publications
- 1 September 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8 (17) , 175504
A six-axis vibration isolation Stewart platform based on displacement cancellation technique
A six-axis active vibration isolation system based on Stewart platform mechanism is developed and its performance is investigated in this study. The developed system comprises an end effector, referred to a Stewart platform, which is suspended by six identical active isolation units arranged in a mutually orthogonal configuration. Each individual unit consists of two magnetic suspension modules connected in series and independently controlled using a novel approach called the displacement cancellation technique. Consequently, each unit functions as a single-axis vibration isolation system. The efficacy of the end effector in achieving six-axis vibration isolation is evaluated by experimental investigations of its static and dynamic performance. Since the overall behavior of the isolation platform depends on the characteristics of individual unit, the detailed theoretical and experimental analyses of a single unit are carried out as well in this paper. Both theoretical predictions and experimental results demonstrate that the proposed system is effective to isolate both direct disturbances and ground-induced vibrations.
- 1 September 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8 (17) , 175504
A six-axis vibration isolation Stewart platform based on displacement cancellation technique
A six-axis active vibration isolation system based on Stewart platform mechanism is developed and its performance is investigated in this study. The developed system comprises an end effector, referred to a Stewart platform, which is suspended by six identical active isolation units arranged in a mutually orthogonal configuration. Each individual unit consists of two magnetic suspension modules connected in series and independently controlled using a novel approach called the displacement cancellation technique. Consequently, each unit functions as a single-axis vibration isolation system. The efficacy of the end effector in achieving six-axis vibration isolation is evaluated by experimental investigations of its static and dynamic performance. Since the overall behavior of the isolation platform depends on the characteristics of individual unit, the detailed theoretical and experimental analyses of a single unit are carried out as well in this paper. Both theoretical predictions and experimental results demonstrate that the proposed system is effective to isolate both direct disturbances and ground-induced vibrations.
- 9 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 18 (4) , 948-957
Aerial Push-Button With Two-Stage Tactile Feedback Using Reflected Airborne Ultrasound Focus
We developed a new aerial push-button with tactile feedback using focused airborne ultrasound. This study has two significant novelties compared to past related studies: 1) ultrasound emitters are equipped behind the user's finger and reflected ultrasound emission that is focused just above the solid plane placed under the finger presents tactile feedback to a finger pad, and 2) tactile feedback is presented at two stages during pressing motion; at the time of pushing the button and withdrawing the finger from it. The former has a significant advantage in apparatus implementation in that the input surface of the device can be composed of a generic thin plane including touch panels, potentially capable of presenting input touch feedback only when the user touches objects on the screen. We experimentally found that the two-stage tactile presentation is much more effective in strengthening perceived tactile stimulation and believability of input completion when compared with a conventional single-stage method. This study proposes a composition of an aerial push-button in much more practical use than ever. The proposed system composition is expected to be one of the simplest frameworks in the airborne ultrasound tactile interface.
- 9 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 18 (4) , 948-957
Aerial Push-Button With Two-Stage Tactile Feedback Using Reflected Airborne Ultrasound Focus
We developed a new aerial push-button with tactile feedback using focused airborne ultrasound. This study has two significant novelties compared to past related studies: 1) ultrasound emitters are equipped behind the user's finger and reflected ultrasound emission that is focused just above the solid plane placed under the finger presents tactile feedback to a finger pad, and 2) tactile feedback is presented at two stages during pressing motion; at the time of pushing the button and withdrawing the finger from it. The former has a significant advantage in apparatus implementation in that the input surface of the device can be composed of a generic thin plane including touch panels, potentially capable of presenting input touch feedback only when the user touches objects on the screen. We experimentally found that the two-stage tactile presentation is much more effective in strengthening perceived tactile stimulation and believability of input completion when compared with a conventional single-stage method. This study proposes a composition of an aerial push-button in much more practical use than ever. The proposed system composition is expected to be one of the simplest frameworks in the airborne ultrasound tactile interface.
- 25 March 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 137 (12)
Focusing of airborne ultrasound emitted by a flexurally vibrating plate using a transmission mask with spatially designed holes
We propose a focusing method of intense midair ultrasound out of ultrasonic emission from a single flexurally vibrating plate partially covered with a purposely designed amplitude mask. Many applications relying on nonlinear acoustic effects, such as radiation force employed in acoustic levitation, have been devised. For those applications, focused intense airborne ultrasound is conventionally formed using phased arrays of transducers or sound sources with specific fabricated shapes. However, the former strategies are costly, and the latter may require minute three-dimensional fabrication processes, which both hinder their utilization, especially in constructing a large ultrasound-emitting aperture. Our method offers a possible solution for this, where the amplitude masks are designed depending on the positions of nodes and antinodes of the vibrating plate. We experimentally demonstrate the successful formation of midair ultrasound focus at a desired position, which is localized in a region whose diameter is less than a few wavelengths. Our method only requires a monolithic plate, a driving transducer under the plate, and an amplitude mask fabricated out of laser machining of an acrylic plate. Magnification of the spatial scale of ultrasound apertures based on our method is much more readily and affordably achieved than conventional methods, leading to new midair ultrasound applications with the whole-room workspace.
- 25 March 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 137 (12)
Focusing of airborne ultrasound emitted by a flexurally vibrating plate using a transmission mask with spatially designed holes
We propose a focusing method of intense midair ultrasound out of ultrasonic emission from a single flexurally vibrating plate partially covered with a purposely designed amplitude mask. Many applications relying on nonlinear acoustic effects, such as radiation force employed in acoustic levitation, have been devised. For those applications, focused intense airborne ultrasound is conventionally formed using phased arrays of transducers or sound sources with specific fabricated shapes. However, the former strategies are costly, and the latter may require minute three-dimensional fabrication processes, which both hinder their utilization, especially in constructing a large ultrasound-emitting aperture. Our method offers a possible solution for this, where the amplitude masks are designed depending on the positions of nodes and antinodes of the vibrating plate. We experimentally demonstrate the successful formation of midair ultrasound focus at a desired position, which is localized in a region whose diameter is less than a few wavelengths. Our method only requires a monolithic plate, a driving transducer under the plate, and an amplitude mask fabricated out of laser machining of an acrylic plate. Magnification of the spatial scale of ultrasound apertures based on our method is much more readily and affordably achieved than conventional methods, leading to new midair ultrasound applications with the whole-room workspace.
- Open Access
- 27 January 2025
- Published by Elsevier in Applied Acoustics
- Vol. 231
Spatially variable parametric sound image presentation with sparsely arranged ultrasonic sources with controlled emission direction
- 27 January 2025
- Published by Elsevier in Applied Acoustics
- Vol. 231
Open AccessSpatially variable parametric sound image presentation with sparsely arranged ultrasonic sources with controlled emission direction