Maria Isabel Vega Martinez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Maria Isabel Vega Martinez has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Nicholas Sharp
Material Measurement Laboratory National Institute of Standards and Technology Gaithersburg MD 20899 USA
3 shared publications - Colleen Bryan Sallee
National Institute of Standards and Technology (NIST), Chemical Sciences Division , Gaithersburg, MD 20899, USA
2 shared publications - John R. Sieber
National Institute of Standards and Technology
2 shared publications - Rick L. Paul
Chemical Sciences Division, National Institute of Standards and Technology, Gaithersburg, USA
2 shared publications - Adam L. Pintar
National Institute of Standards and Technology
1 shared publication - Anthony F Marlow1 shared publication
Latest Publications
- 26 June 2025
- Published by Wiley in Geostandards and Geoanalytical Research
- Vol. 49 (4) , 781-798
A Comparison of Bulk with Micro‐Volume Elemental Values for NIST SRM 610 and NIST SRM 612
NIST SRM 610 and 612 (Trace Elements in Glass) are routinely used for microanalytical measurements but were designed to be bulk‐scale reference materials. This study investigates an approach to quantify the differences between values for elements obtained using the bulk techniques ICP‐OES, INAA and CNPGAA, and values obtained using the predominant microanalytical technique LA‐ICP‐MS. The results from bulk techniques and LA‐ICP‐MS were also compared with currently accepted mass fractions reported in the Certificates of Analysis (CoA) and the literature. The element suite measured was based on the needs of the forensic and geological microanalysis communities, and included B, Ce, Hf, K, La, Li, Ti and Zr. These additional elements are either not included or do not have uncertainty values in the CoAs for NIST SRMs 610 and 612 but are available as community consensus values, which include uncertainties. The measurement results were processed using Monte Carlo (MC) uncertainty analysis for each technique to provide a comprehensive calculation of expanded uncertainties for use in future research. Measurements of mass fractions of the same element both within and between fragments in the LA‐ICP‐MS data were observed to be correlated due to the use of only one calibration material, which was Float Glass Standard (FGS) 2, as that reference material is not directly traceable to NIST SRMs 610 and 612, and is predominantly used in the forensic community. The MC treatment was expected to cause increases in the overall uncertainty values compared with traditional Guide to the Expression of Uncertainty in Measurement (GUM) treatment for all measurements, which was the case for LA‐ICP‐MS measurements of all elements in NIST SRM 610 and NIST SRM 612 (except for Mn in NIST SRM 610). However, for bulk measurements of Ce, Li and Rb in NIST SRM 610, and bulk measurements of Li, Mn, Ti and Zr for NIST SRM 612, the uncertainty decreased due to MC more precisely determining the uncertainty contribution compared with a more conservative approximation from GUM. All results were compared by using E n scores to assess the relative agreement between bulk‐ and micro‐scale measurements, CoA values and to community consensus values. The findings point out the limitations of the current forensic glass reference materials for high precision microanalytical measurements, especially due to the relatively high uncertainty values associated with Float Glass Standard (FGS) 2. This situation underscores the need for new reference materials specifically designed for homogeneity at the micro‐scale for trace element measurement.
- 26 June 2025
- Published by Wiley in Geostandards and Geoanalytical Research
- Vol. 49 (4) , 781-798
A Comparison of Bulk with Micro‐Volume Elemental Values for NIST SRM 610 and NIST SRM 612
NIST SRM 610 and 612 (Trace Elements in Glass) are routinely used for microanalytical measurements but were designed to be bulk‐scale reference materials. This study investigates an approach to quantify the differences between values for elements obtained using the bulk techniques ICP‐OES, INAA and CNPGAA, and values obtained using the predominant microanalytical technique LA‐ICP‐MS. The results from bulk techniques and LA‐ICP‐MS were also compared with currently accepted mass fractions reported in the Certificates of Analysis (CoA) and the literature. The element suite measured was based on the needs of the forensic and geological microanalysis communities, and included B, Ce, Hf, K, La, Li, Ti and Zr. These additional elements are either not included or do not have uncertainty values in the CoAs for NIST SRMs 610 and 612 but are available as community consensus values, which include uncertainties. The measurement results were processed using Monte Carlo (MC) uncertainty analysis for each technique to provide a comprehensive calculation of expanded uncertainties for use in future research. Measurements of mass fractions of the same element both within and between fragments in the LA‐ICP‐MS data were observed to be correlated due to the use of only one calibration material, which was Float Glass Standard (FGS) 2, as that reference material is not directly traceable to NIST SRMs 610 and 612, and is predominantly used in the forensic community. The MC treatment was expected to cause increases in the overall uncertainty values compared with traditional Guide to the Expression of Uncertainty in Measurement (GUM) treatment for all measurements, which was the case for LA‐ICP‐MS measurements of all elements in NIST SRM 610 and NIST SRM 612 (except for Mn in NIST SRM 610). However, for bulk measurements of Ce, Li and Rb in NIST SRM 610, and bulk measurements of Li, Mn, Ti and Zr for NIST SRM 612, the uncertainty decreased due to MC more precisely determining the uncertainty contribution compared with a more conservative approximation from GUM. All results were compared by using E n scores to assess the relative agreement between bulk‐ and micro‐scale measurements, CoA values and to community consensus values. The findings point out the limitations of the current forensic glass reference materials for high precision microanalytical measurements, especially due to the relatively high uncertainty values associated with Float Glass Standard (FGS) 2. This situation underscores the need for new reference materials specifically designed for homogeneity at the micro‐scale for trace element measurement.
- 1 January 2025
- Published by National Institute of Standards and Technology (NIST)
Certification of Standard Reference Material® 1568c Rice Flour
The National Institute of Standards and Technology (NIST) SRM 1568c Rice Flour has value assignments for over 30 analytes, including arsenic species. This material is intended to be used for the evaluation of methods for the determination of elements and arsenic species in this and similar matrices. The material was purchased from commercial vendors. Measurement results were obtained from NIST, National Metrology Institute of Japan (NMIJ), and interlaboratory comparison exercises. This document describes the material, sample preparations, results, and data analysis.
- 1 January 2025
- Published by National Institute of Standards and Technology (NIST)
Certification of Standard Reference Material® 1568c Rice Flour
The National Institute of Standards and Technology (NIST) SRM 1568c Rice Flour has value assignments for over 30 analytes, including arsenic species. This material is intended to be used for the evaluation of methods for the determination of elements and arsenic species in this and similar matrices. The material was purchased from commercial vendors. Measurement results were obtained from NIST, National Metrology Institute of Japan (NMIJ), and interlaboratory comparison exercises. This document describes the material, sample preparations, results, and data analysis.