Benjamin James
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Benjamin James has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Anatoly B. Rosenfeld
Centre for Medical Radiation Physics, University of Wollongong
6 shared publications - David Bolst
University of Wollongong
6 shared publications - Linh T. Tran
Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, Australia
6 shared publications - Marco Petasecca
Centre for Medical Radiation Physics, University of Wollongong
6 shared publications - Marco Povoli
Smart Sensors and Microsystems, SINTEF Digital, 0314 Oslo, Norway
6 shared publications - Michael L. F. Lerch
Centre for Medical Radiation Physics, University of Wollongong
6 shared publications
Latest Publications
- Open Access
- 30 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 12 (1) , 328
Silicon 3D Microdosimeters for Advanced Quality Assurance in Particle Therapy
The Centre for Medical Radiation Physics introduced the concept of Silicon On Insulator (SOI) microdosimeters with 3-Dimensional (3D) cylindrical sensitive volumes (SVs) mimicking the dimensions of cells in an array. Several designs of high-definition 3D SVs fabricated using 3D MEMS technology were implemented. 3D SVs were fabricated in different sizes and configurations with diameters between 18 and 30 µm, thicknesses of 2–50 µm and at a pitch of 50 µm in matrices with volumes of 20 × 20 and 50 × 50. SVs were segmented into sub-arrays to reduce capacitance and avoid pile up in high-dose rate pencil beam scanning applications. Detailed TCAD simulations and charge collection studies in individual SVs have been performed. The microdosimetry probe (MicroPlus) is composed of the silicon microdosimeter and low-noise front–end readout electronics housed in a PMMA waterproof sheath that allows measurements of lineal energies as low as 0.4 keV/µm in water or PMMA. Microdosimetric quantities measured with SOI microdosimeters and the MicroPlus probe were used to evaluate the relative biological effectiveness (RBE) of heavy ions and protons delivered by pencil-beam scanning and passive scattering systems in different particle therapy centres. The 3D detectors and MicroPlus probe developed for microdosimetry have the potential to provide confidence in the delivery of RBE optimized particle therapy when introduced into routine clinical practice.
- 30 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 12 (1) , 328
Open AccessSilicon 3D Microdosimeters for Advanced Quality Assurance in Particle Therapy
The Centre for Medical Radiation Physics introduced the concept of Silicon On Insulator (SOI) microdosimeters with 3-Dimensional (3D) cylindrical sensitive volumes (SVs) mimicking the dimensions of cells in an array. Several designs of high-definition 3D SVs fabricated using 3D MEMS technology were implemented. 3D SVs were fabricated in different sizes and configurations with diameters between 18 and 30 µm, thicknesses of 2–50 µm and at a pitch of 50 µm in matrices with volumes of 20 × 20 and 50 × 50. SVs were segmented into sub-arrays to reduce capacitance and avoid pile up in high-dose rate pencil beam scanning applications. Detailed TCAD simulations and charge collection studies in individual SVs have been performed. The microdosimetry probe (MicroPlus) is composed of the silicon microdosimeter and low-noise front–end readout electronics housed in a PMMA waterproof sheath that allows measurements of lineal energies as low as 0.4 keV/µm in water or PMMA. Microdosimetric quantities measured with SOI microdosimeters and the MicroPlus probe were used to evaluate the relative biological effectiveness (RBE) of heavy ions and protons delivered by pencil-beam scanning and passive scattering systems in different particle therapy centres. The 3D detectors and MicroPlus probe developed for microdosimetry have the potential to provide confidence in the delivery of RBE optimized particle therapy when introduced into routine clinical practice.
- 8 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (3) , 491-500
Application of an SOI Microdosimeter for Monitoring of Neutrons in Various Mixed Radiation Field Environments
Radiation monitoring in space radiation is complex due to galactic cosmic rays (GCRs), solar particle events (SPEs), and albedo particles. Thermal neutrons are an important component in the Moon radiation albedo field which can cause single event upset (SEU) in electronics when they interact with the 10 B present in electronic components. In this work, we studied an application of silicon on insulator (SOI) microdosimeters for neutron monitoring in various mixed radiation field environments. A 10- $\mu \text{m}$ SOI microdosimeter was utilized in conjunction with a 10 B 4 C thin-film converter to successfully measure the thermal neutron contribution out of field of a therapeutic proton beam as well as an 18-MV X-ray linear accelerator (LINAC). The microdosimeter was placed downstream of the Bragg peak (BP) as well as laterally out of field of the proton beam and at two positions along the treatment couch of the 18-MV LINAC. It was demonstrated that the 10- $\mu \text{m}$ SOI microdosimeter with 10 B 4 C converter is suitable for detection of thermal neutrons with excellent discrimination of gamma, fast and thermal neutron components in the presence of a gamma-neutron pulsed field of an 18-MV LINAC. To reduce the gamma contribution and further improve detection of neutrons in mixed radiation fields, a new $2 ~\mu \text{m}$ Mushroom-planar microdosimeter was fabricated and characterized in detail using an ion beam induced charge collection (IBIC) technique with 1.78 MeV $\text{H}e^{\mathrm {2+}}$ ions. It was demonstrated that this $2 ~\mu \text{m}$ SOI microdosimeter can be operated in a passive mode. The SOI microdosimeter with the 10 B 4 C converter can be recommended for the detection of thermal neutrons for SEU prediction in the mixed gamma-neutron fields during space missions, especially for the Moon mission.
- 8 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (3) , 491-500
Application of an SOI Microdosimeter for Monitoring of Neutrons in Various Mixed Radiation Field Environments
Radiation monitoring in space radiation is complex due to galactic cosmic rays (GCRs), solar particle events (SPEs), and albedo particles. Thermal neutrons are an important component in the Moon radiation albedo field which can cause single event upset (SEU) in electronics when they interact with the 10 B present in electronic components. In this work, we studied an application of silicon on insulator (SOI) microdosimeters for neutron monitoring in various mixed radiation field environments. A 10- $\mu \text{m}$ SOI microdosimeter was utilized in conjunction with a 10 B 4 C thin-film converter to successfully measure the thermal neutron contribution out of field of a therapeutic proton beam as well as an 18-MV X-ray linear accelerator (LINAC). The microdosimeter was placed downstream of the Bragg peak (BP) as well as laterally out of field of the proton beam and at two positions along the treatment couch of the 18-MV LINAC. It was demonstrated that the 10- $\mu \text{m}$ SOI microdosimeter with 10 B 4 C converter is suitable for detection of thermal neutrons with excellent discrimination of gamma, fast and thermal neutron components in the presence of a gamma-neutron pulsed field of an 18-MV LINAC. To reduce the gamma contribution and further improve detection of neutrons in mixed radiation fields, a new $2 ~\mu \text{m}$ Mushroom-planar microdosimeter was fabricated and characterized in detail using an ion beam induced charge collection (IBIC) technique with 1.78 MeV $\text{H}e^{\mathrm {2+}}$ ions. It was demonstrated that this $2 ~\mu \text{m}$ SOI microdosimeter can be operated in a passive mode. The SOI microdosimeter with the 10 B 4 C converter can be recommended for the detection of thermal neutrons for SEU prediction in the mixed gamma-neutron fields during space missions, especially for the Moon mission.
- 28 April 2021
- Published by Wiley in Medical Physics
- Vol. 48 (8) , 4532-4541
In‐field and out‐of‐field microdosimetric characterisation of a 62 MeV proton beam at CATANA
Purpose: A 5 and 10 μm thin silicon on insulator (SOI) 3D mushroom microdosimeter was used to characterize both the in‐field and out‐of‐field of a 62 MeV proton beam.Methods: The SOI mushroom microdosimeter consisted of an array of cylindrical sensitive volumes (SVs), developed by the Centre for Medical Radiation Physics, University of Wollongong, was irradiated with 62 MeV protons at the CATANA (Centro di AdroTerapia Applicazioni Nucleari Avanzate) facility in Catania, Italy, a facility dedicated to the radiation treatment of ocular melanomas. Dose mean lineal energy, (), values were obtained at various depths in PMMA along a pristine and spread out Bragg peak (SOBP). The measured microdosimetric spectra at each position were then used as inputs into the modified Microdosimetric Kinetic Model (MKM) to derive the RBE for absorbed dose in a middle of the SOBP 2Gy (RBED). Microdosimetric spectra were obtained with both the 5 and 10 μm 3D SOI microdosimeters, with a focus on the distal part of the BP. The in‐field and out‐of‐field measurement configurations along the Bragg curve were modeled in Geant4 for comparison with experimental results. Lateral out‐of‐field measurements were performed to study secondary particles’ contribution to normal tissue’s dose, up to 12 mm from the edge of the beam field, and quality factor and dose equivalent results were obtained.Results: Comparison between experimental and simulation results showed good agreement between one another for both the pristine and SOBP beams in terms of and RBED. Though a small discrepancy between experiment and simulation was seen at the entrance of the Bragg curve, where experimental results were slightly lower than Geant4. The dose equivalent value measured 12 mm from the edge of the target volume was 1.27 ± 0.15 mSv/Gy with a value of 2.52 ± 0.30, both of which agree within uncertainty with Geant4 simulation.Conclusions: These results demonstrate that SOI microdosimeters are an effective tool to predict RBED in‐field as well as dose equivalent monitoring out‐of‐field to provide insight to probability of second cancer generation.
- 28 April 2021
- Published by Wiley in Medical Physics
- Vol. 48 (8) , 4532-4541
In‐field and out‐of‐field microdosimetric characterisation of a 62 MeV proton beam at CATANA
Purpose: A 5 and 10 μm thin silicon on insulator (SOI) 3D mushroom microdosimeter was used to characterize both the in‐field and out‐of‐field of a 62 MeV proton beam.Methods: The SOI mushroom microdosimeter consisted of an array of cylindrical sensitive volumes (SVs), developed by the Centre for Medical Radiation Physics, University of Wollongong, was irradiated with 62 MeV protons at the CATANA (Centro di AdroTerapia Applicazioni Nucleari Avanzate) facility in Catania, Italy, a facility dedicated to the radiation treatment of ocular melanomas. Dose mean lineal energy, (), values were obtained at various depths in PMMA along a pristine and spread out Bragg peak (SOBP). The measured microdosimetric spectra at each position were then used as inputs into the modified Microdosimetric Kinetic Model (MKM) to derive the RBE for absorbed dose in a middle of the SOBP 2Gy (RBED). Microdosimetric spectra were obtained with both the 5 and 10 μm 3D SOI microdosimeters, with a focus on the distal part of the BP. The in‐field and out‐of‐field measurement configurations along the Bragg curve were modeled in Geant4 for comparison with experimental results. Lateral out‐of‐field measurements were performed to study secondary particles’ contribution to normal tissue’s dose, up to 12 mm from the edge of the beam field, and quality factor and dose equivalent results were obtained.Results: Comparison between experimental and simulation results showed good agreement between one another for both the pristine and SOBP beams in terms of and RBED. Though a small discrepancy between experiment and simulation was seen at the entrance of the Bragg curve, where experimental results were slightly lower than Geant4. The dose equivalent value measured 12 mm from the edge of the target volume was 1.27 ± 0.15 mSv/Gy with a value of 2.52 ± 0.30, both of which agree within uncertainty with Geant4 simulation.Conclusions: These results demonstrate that SOI microdosimeters are an effective tool to predict RBED in‐field as well as dose equivalent monitoring out‐of‐field to provide insight to probability of second cancer generation.
- 22 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (5) , 897-905
Radiation Shielding Evaluation of Spacecraft Walls Against Heavy Ions Using Microdosimetry
Despite the low contribution of heavy ions to the total fluence in the space radiation environment, their radiobiological effect on the human body is extremely high. In this article, we investigated the radiation field which resulted from the interaction of galactic cosmic rays (GCRs), specifically some heavy ions and energies, typically encountered in space with a realistic multilayer sample of the International Space Station (ISS) Columbus module's shielding wall. The quality factor, Q, and the normalized dose equivalent, H, derived from microdosimetric measurements for C, Ne, and Si ions behind different spacecraft wall configurations and materials are presented in this article. Particularly, carbon fiber, polyoxymethylene, and perspex with same areal density compared to currently used aluminum were investigated.
- 22 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (5) , 897-905
Radiation Shielding Evaluation of Spacecraft Walls Against Heavy Ions Using Microdosimetry
Despite the low contribution of heavy ions to the total fluence in the space radiation environment, their radiobiological effect on the human body is extremely high. In this article, we investigated the radiation field which resulted from the interaction of galactic cosmic rays (GCRs), specifically some heavy ions and energies, typically encountered in space with a realistic multilayer sample of the International Space Station (ISS) Columbus module's shielding wall. The quality factor, Q, and the normalized dose equivalent, H, derived from microdosimetric measurements for C, Ne, and Si ions behind different spacecraft wall configurations and materials are presented in this article. Particularly, carbon fiber, polyoxymethylene, and perspex with same areal density compared to currently used aluminum were investigated.
- 25 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (1) , 169-174
A Solid-State Microdosimeter for Dose and Radiation Quality Monitoring for Astronauts in Space
This article presents a study of the response of the silicon on insulator (SOI) microdosimeter with 3-D sensitive volumes (SVs) to 400 MeV/u 16 O and 500 MeV/u 56 Fe ions mimicking galactic cosmic rays outside and inside the International Space Station (ISS). An average quality factor (Q̅) and the dose equivalent (H) of the radiation field were obtained experimentally, and the results were compared with GEANT4 simulations.
- 25 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (1) , 169-174
A Solid-State Microdosimeter for Dose and Radiation Quality Monitoring for Astronauts in Space
This article presents a study of the response of the silicon on insulator (SOI) microdosimeter with 3-D sensitive volumes (SVs) to 400 MeV/u 16 O and 500 MeV/u 56 Fe ions mimicking galactic cosmic rays outside and inside the International Space Station (ISS). An average quality factor (Q̅) and the dose equivalent (H) of the radiation field were obtained experimentally, and the results were compared with GEANT4 simulations.
- 4 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (1) , 146-153
SOI Thin Microdosimeters for High LET Single-Event Upset Studies in Fe, O, Xe, and Cocktail Ion Beam Fields
The response of a 5 lm thin silicon on insulator (SOI) 3D microdosimeter was investigated for single event upset applications by measuring the LET of different high LET ions. The charge collection characteristics of the device was performed using the Ion Beam Induced Charge collection (IBIC) technique with 3 and 5.5 MeV He2+ ions incident on the microdosimeter. The microdosimeter was irradiated with 16O, 56Fe and 124Xe ions and was able to determine the LET within 5% for most configurations apart from 124Xe. It was observed that on average, measured LET was 12% lower for 30 MeV/u 124Xe ion traversing through different thickness Kapton absorbers in comparison to Geant4 simulations. This discrepancy can be partly attributed to uncertainties in the thickness of the energy degraders and thickness of the SOI layer of the devices. The effects of overlayer thickness variation is not easy observed for ions with much lower LET as O and Fe. Based on that it is difficult to make conclusion that plasma effect is observed for 30 MeV/u 124Xe ions and further research to be carried out for ion with LET higher than 12 MeV/µm.
- 4 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (1) , 146-153
SOI Thin Microdosimeters for High LET Single-Event Upset Studies in Fe, O, Xe, and Cocktail Ion Beam Fields
The response of a 5 lm thin silicon on insulator (SOI) 3D microdosimeter was investigated for single event upset applications by measuring the LET of different high LET ions. The charge collection characteristics of the device was performed using the Ion Beam Induced Charge collection (IBIC) technique with 3 and 5.5 MeV He2+ ions incident on the microdosimeter. The microdosimeter was irradiated with 16O, 56Fe and 124Xe ions and was able to determine the LET within 5% for most configurations apart from 124Xe. It was observed that on average, measured LET was 12% lower for 30 MeV/u 124Xe ion traversing through different thickness Kapton absorbers in comparison to Geant4 simulations. This discrepancy can be partly attributed to uncertainties in the thickness of the energy degraders and thickness of the SOI layer of the devices. The effects of overlayer thickness variation is not easy observed for ions with much lower LET as O and Fe. Based on that it is difficult to make conclusion that plasma effect is observed for 30 MeV/u 124Xe ions and further research to be carried out for ion with LET higher than 12 MeV/µm.
- 10 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 66 (1) , 320-326
SOI Thin Microdosimeter Detectors for Low-Energy Ions and Radiation Damage Studies
The responses of two silicon on insulator (SOI) 3D microdosimeters developed by the Centre for Medical Radiation Physics (CMRP) were investigated with a range of different low energy ions, with high linear energy transfer (LET). The two microdosimeters n-SOI and p-SOI were able to measure the LET of different ions including 7Li, 12C, 16O and 48Ti with ranges below 350 μm in silicon. No plasma effects were seen in the SOI microdosimeters when irradiated with the high LET ions. A Monte Carlo simulation using Geant4 was compared to the experimental measurements, whereby some discrepancies were observed for heavier ions at lower energies. This discrepancy can be partly attributed to uncertainties in the thickness of the energy degraders and overlayers of the devices. The microdosimetric measurements of low energy 16O ions were obtained and compared to a therapeutic 16O ion beam. The radiation hardness of the two devices was studied using the Ion Beam Induced Charge Collection technique (IBIC). Both types of microdosimeters when biased had no essential changes in charge collection efficiency (CCE) in the SV after irradiation with low energy ions.
- 10 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 66 (1) , 320-326
SOI Thin Microdosimeter Detectors for Low-Energy Ions and Radiation Damage Studies
The responses of two silicon on insulator (SOI) 3D microdosimeters developed by the Centre for Medical Radiation Physics (CMRP) were investigated with a range of different low energy ions, with high linear energy transfer (LET). The two microdosimeters n-SOI and p-SOI were able to measure the LET of different ions including 7Li, 12C, 16O and 48Ti with ranges below 350 μm in silicon. No plasma effects were seen in the SOI microdosimeters when irradiated with the high LET ions. A Monte Carlo simulation using Geant4 was compared to the experimental measurements, whereby some discrepancies were observed for heavier ions at lower energies. This discrepancy can be partly attributed to uncertainties in the thickness of the energy degraders and overlayers of the devices. The microdosimetric measurements of low energy 16O ions were obtained and compared to a therapeutic 16O ion beam. The radiation hardness of the two devices was studied using the Ion Beam Induced Charge Collection technique (IBIC). Both types of microdosimeters when biased had no essential changes in charge collection efficiency (CCE) in the SV after irradiation with low energy ions.