Fereydoon Abbassi Davani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Fereydoon Abbassi Davani has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
- Babak Shirani
Department of Nuclear Engineering, University of Isfahan, Isfahan, Iran
4 shared publications - Nikoo Darestani Farahani
Plasma and Nuclear Fusion Research School, Nuclear Science and Technology Research Institute, B. O. Box: 14399-51113, Tehran, Iran
4 shared publications F. Ghasemi
3 shared publications- Hossein Afarideh
Department of Energy Engineering and Physics, Amirkabir University of Technology (Tehran Polytechnic), Tehran, Iran
3 shared publications Zahra Shahbazi Rad
Radiation Application Department, Shahid Beheshti University, Tehran P.O. Box 1983969411, Iran
3 shared publicationsA. Sharghi Ido
Incubator Center of Technology Units of Shahid Beheshti University P.O. Box: 1983963113, Tehran, I. R. of Iran
2 shared publications
Latest Publications
- 29 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-8
Development of a Miniaturized Dipole Electromagnet for GFR Enhancement in an Accelerator Mass Spectrometer
In this study, the design and optimization of a dipole electromagnet pole tip are presented, with the aim of compacting the structure and enhancing the magnetic field quality across the Tanabe optimal width. The optimization process was conducted by introducing adjustable control points at the pole edges of this beam-bending precision instrument, using Genetic Algorithm (GA) and Particle Swarm Optimization (PSO) techniques, coupled with a 2D FEMM simulation code. The simulation results demonstrated a 15.9 % improvement in the horizontal Good Field Region (GFR) compared to the existing dipole in the ES150 ion accelerator’s mass spectrometer, achieving the field uniformity (1 × 10-3). Additionally, the proposed approach led to a 12.3 % reduction in the dipole electromagnet’s overall dimensions, while also reducing magnetic saturation at the edges by 60 % and enhancing manufacturability. Subsequent mass spectrometry of hydrogen ion beams confirmed the presence of H+, H2+, H3+ ions with relative abundances of 72.2 %, 8.9 %, and 18.9 %, respectively. The results validate the accuracy, effectiveness, and potential of the proposed design for future development in advanced diagnostic instrumentation.
- 29 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-8
Development of a Miniaturized Dipole Electromagnet for GFR Enhancement in an Accelerator Mass Spectrometer
In this study, the design and optimization of a dipole electromagnet pole tip are presented, with the aim of compacting the structure and enhancing the magnetic field quality across the Tanabe optimal width. The optimization process was conducted by introducing adjustable control points at the pole edges of this beam-bending precision instrument, using Genetic Algorithm (GA) and Particle Swarm Optimization (PSO) techniques, coupled with a 2D FEMM simulation code. The simulation results demonstrated a 15.9 % improvement in the horizontal Good Field Region (GFR) compared to the existing dipole in the ES150 ion accelerator’s mass spectrometer, achieving the field uniformity (1 × 10-3). Additionally, the proposed approach led to a 12.3 % reduction in the dipole electromagnet’s overall dimensions, while also reducing magnetic saturation at the edges by 60 % and enhancing manufacturability. Subsequent mass spectrometry of hydrogen ion beams confirmed the presence of H+, H2+, H3+ ions with relative abundances of 72.2 %, 8.9 %, and 18.9 %, respectively. The results validate the accuracy, effectiveness, and potential of the proposed design for future development in advanced diagnostic instrumentation.
- 15 April 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 66, 406-414
Characterization of hydrogen plasma bulk in 2.45 GHz ECR ion source
- 15 April 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 66, 406-414
Characterization of hydrogen plasma bulk in 2.45 GHz ECR ion source
- Open Access
- 1 March 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (3)
Characterization and modeling of plasma sheath in 2.45 GHz hydrogen ECR ion sources
In this article, we present a multi-fluid numerical model developed for application on electron cyclotron resonance ion sources (ECRIS). The 1D-model is matured to compute the density of the ion species in the plasma sheath in the presence of an inhomogeneous magnetic field of a 2.45 GHz ECRIS. The multi-fluid model in cylindrical coordinates is focused on solving the continuity and momentum equations of hydrogen plasma particles to characterize their sheath properties. In addition, 28 important processes, including volume and surface collisions, have been included in the COMSOL Multiphysics package to simulate the ECR plasma. We study the elementary processes containing electron–atom, electron–molecule, atom–molecule, molecule–molecule, and particle–wall interactions. Then, the results of the model and the simulation of a 2D-hydrogen plasma are reported, and future perspectives are discussed throughout the paper.
- 1 March 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (3)
Open AccessCharacterization and modeling of plasma sheath in 2.45 GHz hydrogen ECR ion sources
In this article, we present a multi-fluid numerical model developed for application on electron cyclotron resonance ion sources (ECRIS). The 1D-model is matured to compute the density of the ion species in the plasma sheath in the presence of an inhomogeneous magnetic field of a 2.45 GHz ECRIS. The multi-fluid model in cylindrical coordinates is focused on solving the continuity and momentum equations of hydrogen plasma particles to characterize their sheath properties. In addition, 28 important processes, including volume and surface collisions, have been included in the COMSOL Multiphysics package to simulate the ECR plasma. We study the elementary processes containing electron–atom, electron–molecule, atom–molecule, molecule–molecule, and particle–wall interactions. Then, the results of the model and the simulation of a 2D-hydrogen plasma are reported, and future perspectives are discussed throughout the paper.
- 15 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 49 (1) , 424-436
Time-Dependent Thermo-Electro-Magneto-Mechanical Analysis of the TF Coil in Damavand Upgrade Tokamak With Longer Pulse Operation
To reach a more efficient plasma operation, a new configuration is planned for Damavand tokamak toward a longer pulse scenario. The current pulses in the magnetic system will be ten-times extended. This introduces major thermal impacts on the toroidal field (TF) coils due to Joule heating in addition to electromagnetic loads. Each TF coil consists of a winding pack (WP) with epoxy-impregnated glass-mica tape enclosed in an aluminum case. In this work, the combined thermo-electro-magneto-mechanical behavior of the TF coil components is investigated in the long pulse operation. A computational fluid dynamics (CFD) model has been involved to simulate a water cooling in the TF coil using COMSOL. Therefore, the study involves various analyses on the Lorentz force density, thermal load due to the Joule heat, stabilized temperature, heat dissipation, stresses and strains, and TF deviation in vacuum vessel due to the TF coil deformation. Every shot introduces a rise in the temperature of the coil. Thus, depending on the cooling conditions, in a series of consecutive shots, the temperature reaches a limit which is crucial for the mechanical analysis. As a result, although the thermal stress on the WP is highly increased in every long pulse, the total stress (i.e., combined thermal-magnetic stress) decreases compared to the value in the presently short pulse operation. The total stress in the WP can be lower than its magnetic stress due to an increase in elasticity of the coil during the longer pulses, while this result is the opposite for the casing and the epoxy resin.
- 15 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 49 (1) , 424-436
Time-Dependent Thermo-Electro-Magneto-Mechanical Analysis of the TF Coil in Damavand Upgrade Tokamak With Longer Pulse Operation
To reach a more efficient plasma operation, a new configuration is planned for Damavand tokamak toward a longer pulse scenario. The current pulses in the magnetic system will be ten-times extended. This introduces major thermal impacts on the toroidal field (TF) coils due to Joule heating in addition to electromagnetic loads. Each TF coil consists of a winding pack (WP) with epoxy-impregnated glass-mica tape enclosed in an aluminum case. In this work, the combined thermo-electro-magneto-mechanical behavior of the TF coil components is investigated in the long pulse operation. A computational fluid dynamics (CFD) model has been involved to simulate a water cooling in the TF coil using COMSOL. Therefore, the study involves various analyses on the Lorentz force density, thermal load due to the Joule heat, stabilized temperature, heat dissipation, stresses and strains, and TF deviation in vacuum vessel due to the TF coil deformation. Every shot introduces a rise in the temperature of the coil. Thus, depending on the cooling conditions, in a series of consecutive shots, the temperature reaches a limit which is crucial for the mechanical analysis. As a result, although the thermal stress on the WP is highly increased in every long pulse, the total stress (i.e., combined thermal-magnetic stress) decreases compared to the value in the presently short pulse operation. The total stress in the WP can be lower than its magnetic stress due to an increase in elasticity of the coil during the longer pulses, while this result is the opposite for the casing and the epoxy resin.
- 1 June 2019
- Published by Elsevier in Fusion Engineering and Design
- Vol. 143, 1-9
Investigating different methods for calculating the lambda equilibrium parameter for the plasma column in the Damavand tokamak
- 1 June 2019
- Published by Elsevier in Fusion Engineering and Design
- Vol. 143, 1-9
Investigating different methods for calculating the lambda equilibrium parameter for the plasma column in the Damavand tokamak
- 1 May 2018
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 13 (05) , P05029
Monte Carlo study and design of system for implementation of Rotational Total Skin Electron Irradiation technique
Total skin electron irradiation technique is used in treatment of the mycosis fungoid. The implementation of this technique requires non-standard measurements and complex dosimetry methods. Depending on the linear accelerator (Linac) type, bunker size, room dimensions and dosimetry equipment, the design of instruments for appropriate set up and implementation of TSEI in different radiation therapy centers varies. The studies which have been done in this article provide an introduction to the implementing of this method for the first time in Iran and its results can be used for the centers with similar specifications in the world. This article determined the electron beam characteristic of TSEI for the only electron accelerator, located at the radiation center of the Seyed Alshohada Hospital of Isfahan (NEPTUN 10PC), by performing Monte Carlo simulations and using EGSnrc-based codes (BEAMnrc and DOSXYZnrc). For the best uniformity of the vertical profile, the optimal angle of gantry was defined at SSD=350 cm. The effect of the degrader plane that is located at a distance of 20 cm from the patient surface, was evaluated on the amount of energy reduction of the beam, the opening of the electron beam field and the homogeneity of the dose distribution. The transversal dose distribution from the whole treatment with Stanford technique (six dual fields) and Rotational technique was simulated in a CT-based anthropomorphic phantom. Also, the percentage depth dose in the head, neck, thorax, abdomen and legs was obtained for both methods. The simulation results show that the 20o angle between the horizontal and the beam central axis is optimal in order to provide the best vertical dose uniformity. The mean energy decreases from 6.1 MeV (the exit window) to 3 MeV (the treatment surface) by placing a degrader with 0.8 cm thickness in front of the treatment plane. FWHM of the angular distribution of the electron beam increased from 15o at SSD=100 cm to more than 30o on the treatment surface by traversing the PMMA degrader. The MC calculated percentage depth dose curves in different organs of anthropomorphic phantom for RTSEI indicates that the depth of maximum dose is on the surface of the phantom and Isodose curve of 80% is formed at a depth less than 4 mm. the results also show, with the degrader plane in front of the patient, the degree of homogeneity of the dose distribution for both Stanford and rotational techniques is the same.
- 1 May 2018
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 13 (05) , P05029
Monte Carlo study and design of system for implementation of Rotational Total Skin Electron Irradiation technique
Total skin electron irradiation technique is used in treatment of the mycosis fungoid. The implementation of this technique requires non-standard measurements and complex dosimetry methods. Depending on the linear accelerator (Linac) type, bunker size, room dimensions and dosimetry equipment, the design of instruments for appropriate set up and implementation of TSEI in different radiation therapy centers varies. The studies which have been done in this article provide an introduction to the implementing of this method for the first time in Iran and its results can be used for the centers with similar specifications in the world. This article determined the electron beam characteristic of TSEI for the only electron accelerator, located at the radiation center of the Seyed Alshohada Hospital of Isfahan (NEPTUN 10PC), by performing Monte Carlo simulations and using EGSnrc-based codes (BEAMnrc and DOSXYZnrc). For the best uniformity of the vertical profile, the optimal angle of gantry was defined at SSD=350 cm. The effect of the degrader plane that is located at a distance of 20 cm from the patient surface, was evaluated on the amount of energy reduction of the beam, the opening of the electron beam field and the homogeneity of the dose distribution. The transversal dose distribution from the whole treatment with Stanford technique (six dual fields) and Rotational technique was simulated in a CT-based anthropomorphic phantom. Also, the percentage depth dose in the head, neck, thorax, abdomen and legs was obtained for both methods. The simulation results show that the 20o angle between the horizontal and the beam central axis is optimal in order to provide the best vertical dose uniformity. The mean energy decreases from 6.1 MeV (the exit window) to 3 MeV (the treatment surface) by placing a degrader with 0.8 cm thickness in front of the treatment plane. FWHM of the angular distribution of the electron beam increased from 15o at SSD=100 cm to more than 30o on the treatment surface by traversing the PMMA degrader. The MC calculated percentage depth dose curves in different organs of anthropomorphic phantom for RTSEI indicates that the depth of maximum dose is on the surface of the phantom and Isodose curve of 80% is formed at a depth less than 4 mm. the results also show, with the degrader plane in front of the patient, the degree of homogeneity of the dose distribution for both Stanford and rotational techniques is the same.
- 1 November 2017
- Published by Pleiades Publishing Ltd in Physics of Atomic Nuclei
- Vol. 80 (6) , 1119-1125
Monte Carlo Simulation of a Segmented Detector for Low-Energy Electron Antineutrinos
Detection of low-energy electron antineutrinos is of importance for several purposes, such as ex-vessel reactor monitoring, neutrino oscillation studies, etc. The inverse beta decay (IBD) is the...
- 1 November 2017
- Published by Pleiades Publishing Ltd in Physics of Atomic Nuclei
- Vol. 80 (6) , 1119-1125
Monte Carlo Simulation of a Segmented Detector for Low-Energy Electron Antineutrinos
Detection of low-energy electron antineutrinos is of importance for several purposes, such as ex-vessel reactor monitoring, neutrino oscillation studies, etc. The inverse beta decay (IBD) is the...
- 1 September 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (9) , P09026
Design of a side coupled standing wave accelerating tube for NSTRI e-Linac
The design and construction of a 6 MeV electron linear accelerator (e-Linac) was defined in the Institute of Nuclear Science and Technology (NSTRI) for cargo inspection and medical applications. For this accelerator, a side coupled standing wave tube resonant at a frequency of 2998.5 MHZ in π/2 mode was selected. In this article, the authors provide a step-by-step explanation of the process of the design for this tube. The design and simulation of the accelerating and coupling cavities were carried out in five steps; (1) separate design of the accelerating and coupling cavities, (2) design of the coupling aperture between the cavities, (3) design of the entire structure for resonance at the nominal frequency, (4) design of the buncher, and (5) design of the power coupling port. At all design stages, in addition to finding the dimensions of the cavity, the impact of construction tolerances and simulation errors on the electromagnetic parameters were investigated. The values obtained for the coupling coefficient, coupling constant, quality factor and capture efficiency are 2.11, 0.011, 16203 and 36%, respectively. The results of beam dynamics study of the simulated tube in ASTRA have yielded a value of 5.14 π-mm-mrad for the horizontal emittance, 5.06 π-mm-mrad for the vertical emittance, 1.17 mm for the horizontal beam size, 1.16 mm for the vertical beam size and 1090 keV for the energy spread of the output beam.
- 1 September 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (9) , P09026
Design of a side coupled standing wave accelerating tube for NSTRI e-Linac
The design and construction of a 6 MeV electron linear accelerator (e-Linac) was defined in the Institute of Nuclear Science and Technology (NSTRI) for cargo inspection and medical applications. For this accelerator, a side coupled standing wave tube resonant at a frequency of 2998.5 MHZ in π/2 mode was selected. In this article, the authors provide a step-by-step explanation of the process of the design for this tube. The design and simulation of the accelerating and coupling cavities were carried out in five steps; (1) separate design of the accelerating and coupling cavities, (2) design of the coupling aperture between the cavities, (3) design of the entire structure for resonance at the nominal frequency, (4) design of the buncher, and (5) design of the power coupling port. At all design stages, in addition to finding the dimensions of the cavity, the impact of construction tolerances and simulation errors on the electromagnetic parameters were investigated. The values obtained for the coupling coefficient, coupling constant, quality factor and capture efficiency are 2.11, 0.011, 16203 and 36%, respectively. The results of beam dynamics study of the simulated tube in ASTRA have yielded a value of 5.14 π-mm-mrad for the horizontal emittance, 5.06 π-mm-mrad for the vertical emittance, 1.17 mm for the horizontal beam size, 1.16 mm for the vertical beam size and 1090 keV for the energy spread of the output beam.
- 1 April 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (4) , 043504
Experimental investigation on electrical characteristics and dose measurement of dielectric barrier discharge plasma device used for therapeutic application
In this research, a Dielectric Barrier Discharge (DBD) plasma device operating in air has been made. The electrical characteristics of this device like instantaneous power, dissipated power, and discharge capacitance have been measured. Also, the effects of applied voltage on the dissipated power and discharge capacitance of the device have been investigated. The determination of electrical parameters is important in DBD plasma device used in living tissue treatment for choosing the proper treatment doses and preventing the destructive effects. The non-thermal atmospheric pressure DBD plasma source was applied for studying the acceleration of blood coagulation time, in vitro and wound healing time, in vivo. The citrated blood drops coagulated within 5 s treatment time by DBD plasma. The effects of plasma temperature and electric field on blood coagulation have been studied as an affirmation of the applicability of the constructed device. Also, the effect of constructed DBD plasma on wound healing acceleration has been investigated.
- 1 April 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (4) , 043504
Experimental investigation on electrical characteristics and dose measurement of dielectric barrier discharge plasma device used for therapeutic application
In this research, a Dielectric Barrier Discharge (DBD) plasma device operating in air has been made. The electrical characteristics of this device like instantaneous power, dissipated power, and discharge capacitance have been measured. Also, the effects of applied voltage on the dissipated power and discharge capacitance of the device have been investigated. The determination of electrical parameters is important in DBD plasma device used in living tissue treatment for choosing the proper treatment doses and preventing the destructive effects. The non-thermal atmospheric pressure DBD plasma source was applied for studying the acceleration of blood coagulation time, in vitro and wound healing time, in vivo. The citrated blood drops coagulated within 5 s treatment time by DBD plasma. The effects of plasma temperature and electric field on blood coagulation have been studied as an affirmation of the applicability of the constructed device. Also, the effect of constructed DBD plasma on wound healing acceleration has been investigated.
- 1 December 2016
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 118, 140-148
Monte Carlo study of neutron-ambient dose equivalent to patient in treatment room
- 1 December 2016
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 118, 140-148
Monte Carlo study of neutron-ambient dose equivalent to patient in treatment room