Monssef Drissi-Habti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Monssef Drissi-Habti has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Valter Carvelli
Politecnico di Milano
5 shared publications - Manepalli Sriharsha
COSYS Department, Université Gustave Eiffel, F-77447 Marne-la-Vallée, France
3 shared publications - Neginhal Abhijit
COSYS Department, Université Gustave Eiffel, F-77447 Marne-la-Vallée, France
3 shared publications Venkadesh Raman
PRES LUNAM IFSTTAR
3 shared publications- Abdelghani Matine
COSYS Department, Université Gustave Eiffel, F-77447 Marne-la-Vallée, France
2 shared publications - Aghiad Khadour
Components and Systems Department, Université Paris-Est, IFSTTAR, 77420 Champs-sur-Marne, France
2 shared publications
Latest Publications
- 26 March 2026
- Published by Springer Nature
- p. 91-102
The Role of Affordances in Autonomous Vehicle Technology Use Cases: A Comparative Analysis of the United States and France
- 26 March 2026
- Published by Springer Nature
- p. 91-102
The Role of Affordances in Autonomous Vehicle Technology Use Cases: A Comparative Analysis of the United States and France
- Open Access
- 22 January 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (2) , 932
New Concept of Dual-Sinusoid Distributed Fiber-Optic Sensors Antiphase-Placed for the SHM of Smart Composite Structures for Offshore
This work is a follow-up to previous research by our team and is devoted to studying a dual-sinusoidal placement of distributed fiber-optic sensors (FOSs) that are embedded inside an adhesive joint between two composite laminates. The constructed smart continuous fiber-reinforced polymer composite structure is well suited to the structural health monitoring (SHM) system for offshore wind turbine blades. Three main drawbacks of SHM through embedded distributed FOSs, however, have been identified in this article, so their impact must be analyzed. Despite existing research, the influence of the dual-sinusoidal placement under various loading conditions on structural mechanical behavior and sensing functionality has not been considered yet since its introduction. Thus, this study aims to identify the resulting strain patterns and sensing capabilities from an optimized dual-sinusoidal placement of FOSs in various loading cases through finite element modeling. Ultimately, this work illustrates the strain-measuring advantages of dual-sinusoidal FOSs, explains the correspondence between the strains measured by FOSs and that of host structures, and discusses the balance among mechanical influences, sensing functions, and monitoring coverage. It is worth noting that the current work is a still introductory concept that aims at refining key parameters that have been emphasized in previous research, before starting an applied study that will consider both numerical and validation steps on real large smart composite structures.
- 22 January 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (2) , 932
Open AccessNew Concept of Dual-Sinusoid Distributed Fiber-Optic Sensors Antiphase-Placed for the SHM of Smart Composite Structures for Offshore
This work is a follow-up to previous research by our team and is devoted to studying a dual-sinusoidal placement of distributed fiber-optic sensors (FOSs) that are embedded inside an adhesive joint between two composite laminates. The constructed smart continuous fiber-reinforced polymer composite structure is well suited to the structural health monitoring (SHM) system for offshore wind turbine blades. Three main drawbacks of SHM through embedded distributed FOSs, however, have been identified in this article, so their impact must be analyzed. Despite existing research, the influence of the dual-sinusoidal placement under various loading conditions on structural mechanical behavior and sensing functionality has not been considered yet since its introduction. Thus, this study aims to identify the resulting strain patterns and sensing capabilities from an optimized dual-sinusoidal placement of FOSs in various loading cases through finite element modeling. Ultimately, this work illustrates the strain-measuring advantages of dual-sinusoidal FOSs, explains the correspondence between the strains measured by FOSs and that of host structures, and discusses the balance among mechanical influences, sensing functions, and monitoring coverage. It is worth noting that the current work is a still introductory concept that aims at refining key parameters that have been emphasized in previous research, before starting an applied study that will consider both numerical and validation steps on real large smart composite structures.
- Open Access
Electric Cable Insulator Damage Monitoring by Lasso Regression
Since the discovery of electricity, electric cables have become ubiquitous in human constructions, from machines to buildings. Insulators play a crucial role in ensuring the proper functioning of these cables, so it is important to monitor their possible damage, which can be caused by environmental contamination, severe temperature variations, and electrical and mechanical stress. While shunt conductance is a direct health indicator of cable insulation, measuring the cable average shunt conductance is not sufficient for the detection of localized insulator damage, since localized conductance variations are diluted over a long cable length in such measurements. The objective of this paper is to assess the feasibility of reflectometry techniques for the monitoring of insulator damage in electric cables. To this end, the estimation of localized conductance variations is investigated based on electrical measurements made at one end of a cable. To avoid estimating a large number of discretized conductance values along a long cable, the proposed method relies on sparse regression, which automatically focuses on localized conductance variations at unknown positions caused by accidental insulator damage. In order to efficiently apply sparse regression techniques, the telegrapher’s equations describing electric wave propagation in cables are transformed through several steps into a simple linear regression form. Then, Lasso (Least Absolute Shrinkage and Selection Operator) regression is applied to process the voltage and current data collected at a single end of the monitored cable. Numerical simulations show the potential of this method for fast estimation of localized shunt conductance variations.
Open AccessElectric Cable Insulator Damage Monitoring by Lasso Regression
Since the discovery of electricity, electric cables have become ubiquitous in human constructions, from machines to buildings. Insulators play a crucial role in ensuring the proper functioning of these cables, so it is important to monitor their possible damage, which can be caused by environmental contamination, severe temperature variations, and electrical and mechanical stress. While shunt conductance is a direct health indicator of cable insulation, measuring the cable average shunt conductance is not sufficient for the detection of localized insulator damage, since localized conductance variations are diluted over a long cable length in such measurements. The objective of this paper is to assess the feasibility of reflectometry techniques for the monitoring of insulator damage in electric cables. To this end, the estimation of localized conductance variations is investigated based on electrical measurements made at one end of a cable. To avoid estimating a large number of discretized conductance values along a long cable, the proposed method relies on sparse regression, which automatically focuses on localized conductance variations at unknown positions caused by accidental insulator damage. In order to efficiently apply sparse regression techniques, the telegrapher’s equations describing electric wave propagation in cables are transformed through several steps into a simple linear regression form. Then, Lasso (Least Absolute Shrinkage and Selection Operator) regression is applied to process the voltage and current data collected at a single end of the monitored cable. Numerical simulations show the potential of this method for fast estimation of localized shunt conductance variations.
- Open Access
Preliminary Multiphysics Modeling of Electric High-Voltage Cable of Offshore Wind-Farms
During manufacture, handling, transportation, installation and operation, mechanical overstress can affect the electrical and thermal properties of the conductor. As the wires in general are made of copper, which is a very plastically deforming material, these stresses will gradually generate plastic deformations of the copper until the wires start to fail. The objective of this article is to study, by numerical modeling (using Comsol and Abaqus), the impact of damage mechanisms on the electrical and thermal properties of a submarine cable phase. The influence of plasticity and gradual copper wire failure on the physical behavior (electric and thermal) of the phase was assessed. The heat differences between a healthy conductor vs. a damaged one (either deformed plastically and/or with failed wires) derived from the numerical model may be an accurate indicator of the level of damage of wires, thus furthering advanced warning before being obliged to stop the exploitation because a mandatory heavy maintenance of the cables must be scheduled. Note that this can also be achieved by using an optical fiber as a sensor for structural health monitoring. This study will then make it possible to evaluate the impact of the modification of the resistance on the thermal behavior of the cable. All of these simulations will be carried out on one phase of a 36 kV 120 mm² copper submarine cable. Colloquially these are called “copper cables”, meaning cables with Cu conductors (120 mm2 is the smallest conductor cross-section for array cables, which are usually 3-phase cables).
Open AccessPreliminary Multiphysics Modeling of Electric High-Voltage Cable of Offshore Wind-Farms
During manufacture, handling, transportation, installation and operation, mechanical overstress can affect the electrical and thermal properties of the conductor. As the wires in general are made of copper, which is a very plastically deforming material, these stresses will gradually generate plastic deformations of the copper until the wires start to fail. The objective of this article is to study, by numerical modeling (using Comsol and Abaqus), the impact of damage mechanisms on the electrical and thermal properties of a submarine cable phase. The influence of plasticity and gradual copper wire failure on the physical behavior (electric and thermal) of the phase was assessed. The heat differences between a healthy conductor vs. a damaged one (either deformed plastically and/or with failed wires) derived from the numerical model may be an accurate indicator of the level of damage of wires, thus furthering advanced warning before being obliged to stop the exploitation because a mandatory heavy maintenance of the cables must be scheduled. Note that this can also be achieved by using an optical fiber as a sensor for structural health monitoring. This study will then make it possible to evaluate the impact of the modification of the resistance on the thermal behavior of the cable. All of these simulations will be carried out on one phase of a 36 kV 120 mm² copper submarine cable. Colloquially these are called “copper cables”, meaning cables with Cu conductors (120 mm2 is the smallest conductor cross-section for array cables, which are usually 3-phase cables).
- Open Access
Numerical Modeling of the Micromechanics Damage of an Offshore Electrical High-Voltage Phase
Due to the strong growth of offshore renewable energies, research and engineering in this field is constantly expanding. One of the centerpieces of these technologies is the high-voltage electrical cable, generally made of copper, to transport the energy produced from the offshore farm to the onshore station. The critical nature of these cables lies in the proven resistance that they must demonstrate during stays underwater for several years, even decades, in difficult environmental conditions, which begin at the handling, shipping and underground burial stage. The marine environment can lead to deformation of the copper wires well beyond the limit of proportionality and, consequently, to breakage. Copper, although being an exceptional electrical conductor, has very poor mechanical properties. The plasticity generated by the excessive deformation of copper wires affects all of the physical properties of copper. When plasticity develops, electrical transport is affected and the heat within copper increases, but care should be given to not exceed 90 °C, as this would result in the shutdown of the cable with dramatic economic consequences. The work carried out in this article, which is part of the National Project EMODI as well as the European Project FLOW-CAM, aims at studying the mechanical behavior of the phase in order to correlate the deformation levels reached to the phase geometry as well as operating mechanisms of damage which reflect the proliferation of microstructural defects within the conductor. To do this, we propose a numerical model using Abaqus. Correct description of the effects of several parameters (geometry of the phase) and plasticity development on the performance of the phase were simulated and discussed.
Open AccessNumerical Modeling of the Micromechanics Damage of an Offshore Electrical High-Voltage Phase
Due to the strong growth of offshore renewable energies, research and engineering in this field is constantly expanding. One of the centerpieces of these technologies is the high-voltage electrical cable, generally made of copper, to transport the energy produced from the offshore farm to the onshore station. The critical nature of these cables lies in the proven resistance that they must demonstrate during stays underwater for several years, even decades, in difficult environmental conditions, which begin at the handling, shipping and underground burial stage. The marine environment can lead to deformation of the copper wires well beyond the limit of proportionality and, consequently, to breakage. Copper, although being an exceptional electrical conductor, has very poor mechanical properties. The plasticity generated by the excessive deformation of copper wires affects all of the physical properties of copper. When plasticity develops, electrical transport is affected and the heat within copper increases, but care should be given to not exceed 90 °C, as this would result in the shutdown of the cable with dramatic economic consequences. The work carried out in this article, which is part of the National Project EMODI as well as the European Project FLOW-CAM, aims at studying the mechanical behavior of the phase in order to correlate the deformation levels reached to the phase geometry as well as operating mechanisms of damage which reflect the proliferation of microstructural defects within the conductor. To do this, we propose a numerical model using Abaqus. Correct description of the effects of several parameters (geometry of the phase) and plasticity development on the performance of the phase were simulated and discussed.
- Open Access
Modelling Electro-Mechanical Behaviour of an XLPE Insulation Layer for Hi-Voltage Composite Power Cables: Effect of Voids on Onset of Coalescence
The harshness of the submarine environment represents a serious threat for immersed high voltage power cables, extensively used for offshore wind farms, which in turn are supposed to last for at least 20 years for their total investment to be economically viable. The Crosslinked Polyethylene (XLPE) used for the insulating layer of the cables may suffer different degradation phenomena, leading to unexpected breakdowns and rises in costs. In this work, numerical simulations have been developed to study the mechanisms by which micrometric pores inside XLPE can enlarge and coalesce (namely, water treeing) when the insulation is subjected to the intense electric field generated by hi-voltage wires. The study aim is to predict material plasticization next to voids, which is supposed to represent the onset of coalescence of neighboring pores. A microscale-level finite element coupled electro-mechanics model has been developed to describe the interactions between the intense electric fields and the subsequent Maxwell stresses in a dielectric. The roles of different influencing parameters such as distance, relative volumes, and the shape of two neighboring voids in a representative unit volume are considered. Finally, the behavior of a generic microstructure characterized by randomly distributed voids immersed in an electric field is simulated.
Open AccessModelling Electro-Mechanical Behaviour of an XLPE Insulation Layer for Hi-Voltage Composite Power Cables: Effect of Voids on Onset of Coalescence
The harshness of the submarine environment represents a serious threat for immersed high voltage power cables, extensively used for offshore wind farms, which in turn are supposed to last for at least 20 years for their total investment to be economically viable. The Crosslinked Polyethylene (XLPE) used for the insulating layer of the cables may suffer different degradation phenomena, leading to unexpected breakdowns and rises in costs. In this work, numerical simulations have been developed to study the mechanisms by which micrometric pores inside XLPE can enlarge and coalesce (namely, water treeing) when the insulation is subjected to the intense electric field generated by hi-voltage wires. The study aim is to predict material plasticization next to voids, which is supposed to represent the onset of coalescence of neighboring pores. A microscale-level finite element coupled electro-mechanics model has been developed to describe the interactions between the intense electric fields and the subsequent Maxwell stresses in a dielectric. The roles of different influencing parameters such as distance, relative volumes, and the shape of two neighboring voids in a representative unit volume are considered. Finally, the behavior of a generic microstructure characterized by randomly distributed voids immersed in an electric field is simulated.
- Open Access
A Review on Multi-Terminal High Voltage Direct Current Networks for Wind Power Integration
With the growing pressure to substitute fossil fuel-based generation, Renewable Energy Sources (RES) have become one of the main solutions from the power sector in the fight against climate change. Offshore wind farms, for example, are an interesting alternative to increase renewable power production, but they represent a challenge when being interconnected to the grid, since new installations are being pushed further off the coast due to noise and visual pollution restrictions. In this context, Multi-Terminal High Voltage Direct Current (MT-HVDC) networks are the most preferred technology for this purpose and for onshore grid reinforcements. They also enable the delivery of power from the shore to offshore Oil and Gas (O&G) production platforms, which can help lower the emissions in the transition away from fossil fuels. In this work, we review relevant aspects of the operation and control of MT-HVDC networks for wind power integration. The review approaches topics such as the main characteristics of MT-HVDC projects under discussion/commissioned around the world, rising challenges in the control and the operation of MT-HVDC networks and the modeling and the control of the Modular Multilevel Converter (MMC) stations. To illustrate the challenges on designing the control system of a MT-HVDC network and to corroborate the technical discussions, a simulation of a three-terminal MT-HVDC network integrating wind power generation and offshore O&G production units to the onshore grid is performed in Matlab’s Simscape Electrical toolbox. The results highlight the main differences between two alternatives to design the control system for an MT-HVDC network.
Open AccessA Review on Multi-Terminal High Voltage Direct Current Networks for Wind Power Integration
With the growing pressure to substitute fossil fuel-based generation, Renewable Energy Sources (RES) have become one of the main solutions from the power sector in the fight against climate change. Offshore wind farms, for example, are an interesting alternative to increase renewable power production, but they represent a challenge when being interconnected to the grid, since new installations are being pushed further off the coast due to noise and visual pollution restrictions. In this context, Multi-Terminal High Voltage Direct Current (MT-HVDC) networks are the most preferred technology for this purpose and for onshore grid reinforcements. They also enable the delivery of power from the shore to offshore Oil and Gas (O&G) production platforms, which can help lower the emissions in the transition away from fossil fuels. In this work, we review relevant aspects of the operation and control of MT-HVDC networks for wind power integration. The review approaches topics such as the main characteristics of MT-HVDC projects under discussion/commissioned around the world, rising challenges in the control and the operation of MT-HVDC networks and the modeling and the control of the Modular Multilevel Converter (MMC) stations. To illustrate the challenges on designing the control system of a MT-HVDC network and to corroborate the technical discussions, a simulation of a three-terminal MT-HVDC network integrating wind power generation and offshore O&G production units to the onshore grid is performed in Matlab’s Simscape Electrical toolbox. The results highlight the main differences between two alternatives to design the control system for an MT-HVDC network.
- Open Access
Fiber-Optic Sensors (FOS) for Smart High Voltage Composite Cables—Numerical Simulation of Multi-Parameter Bending Effects Generated by Irregular Seabed Topography
Offshore renewable energy requires reliable high-voltage electric power cables to transport electricity to onshore stations. These power cables are critical infrastructures that are shipped to deep seas through shipping and handling operations and, once mounted, must then evolve in extreme conditions (sea, salt, wind, water-pressure, seabed topography, etc.). All of these operations and working conditions can lead to yielding of copper conductors, often resulting in electric shutdown. Indeed, copper is an excellent electric conductor (conductivity), but its mechanical properties are very poor. If any negligence occurs during the shipping and/or handling operations, copper can undergo plasticity, with effects on both mechanical and electric properties. It is therefore of prime importance to establish a reliable structural health-monitoring (SHM) technique that will enable the continuous recording of copper strain and temperature along a cable, and this has been proven using fiber-optic (FOS) sensors, when the phase is under tensile loading. In this prospective article, the scope is to maintain previous simulations and thus show that by the judicious placement of FOS, one can monitor strain and temperature within cables that are submitted to a bending. This article does not aim to deal directly with the case of a cable that undergoes bending on sloppy areas in seabeds. The idea behind the work is to suggest a concept for the use of embedded fiber-optic sensors and to think about all of what remains to be done as research in order to further suggest this technology to cable manufacturers.
Open AccessFiber-Optic Sensors (FOS) for Smart High Voltage Composite Cables—Numerical Simulation of Multi-Parameter Bending Effects Generated by Irregular Seabed Topography
Offshore renewable energy requires reliable high-voltage electric power cables to transport electricity to onshore stations. These power cables are critical infrastructures that are shipped to deep seas through shipping and handling operations and, once mounted, must then evolve in extreme conditions (sea, salt, wind, water-pressure, seabed topography, etc.). All of these operations and working conditions can lead to yielding of copper conductors, often resulting in electric shutdown. Indeed, copper is an excellent electric conductor (conductivity), but its mechanical properties are very poor. If any negligence occurs during the shipping and/or handling operations, copper can undergo plasticity, with effects on both mechanical and electric properties. It is therefore of prime importance to establish a reliable structural health-monitoring (SHM) technique that will enable the continuous recording of copper strain and temperature along a cable, and this has been proven using fiber-optic (FOS) sensors, when the phase is under tensile loading. In this prospective article, the scope is to maintain previous simulations and thus show that by the judicious placement of FOS, one can monitor strain and temperature within cables that are submitted to a bending. This article does not aim to deal directly with the case of a cable that undergoes bending on sloppy areas in seabeds. The idea behind the work is to suggest a concept for the use of embedded fiber-optic sensors and to think about all of what remains to be done as research in order to further suggest this technology to cable manufacturers.
- Open Access
Concept of Placement of Fiber-Optic Sensor in Smart Energy Transport Cable under Tensile Loading
Due to the exponential growth in offshore renewable energies and structures such as floating offshore wind turbines and wave power converters, the research and engineering in this field is experiencing exceptional development. This emergence of offshore renewable energy requires power cables which are usually made up of copper to transport this energy ashore. These power cables are critical structures that must withstand harsh environmental conditions, handling, and shipping, at high seas which can cause copper wires to deform well above the limit of proportionality and consequently break. Copper, being an excellent electric conductor, has, however, very weak mechanical properties. If plasticity propagates inside copper not only will the mechanical properties be affected, but the electrical properties are also disrupted. Constantly monitoring such large-scale structures can be carried out by providing continuous strain using fiber-optic sensors (FOSs). The embedding of optical fibers within the cables (not within the phase) is practiced. Nevertheless, these optical fibers are first introduced into a cylinder of larger diameter than the optical fiber before this same fiber is embedded within the insulator surrounding the phases. Therefore, this type of embedding can in no way give a precise idea of the true deformation of the copper wires inside the phase. In this article, a set of numerical simulations are carried-out on a single phase (we are not yet working on the whole cable) with the aim of conceptualizing the placement of FOSs that will monitor strain and temperature within the conductor. It is well known that copper wire must never exceed temperatures above 90 °C, as this will result in shutdown of the whole system and therefore result in heavy maintenance, which would be a real catastrophe, economically speaking. This research explores the option of embedding sensors in several areas of the phase and how this can enable obtaining strain values that are representative of what really is happening in the conductor. It is, therefore, the primary objective of the current preliminary model to try to prove that the principle of embedding sensors in between copper wires can be envisaged, in particular to obtain an accurate idea about strain tensor of helical ones (multi-parameter strain sensing). The challenge is to ensure that they are not plastically deformed and hence able to transport electricity without exceeding or even becoming closer to 90 °C (fear of shutdown). The research solely focuses on mechanical aspects of the sensors. There are certainly some others, pertaining to sensors physics, instrumentation, and engineering, that are of prime importance, too. The upstream strategy of this research is to come up with a general concept that can be refined later by including, step by step, all the aspects listed above.
Open AccessConcept of Placement of Fiber-Optic Sensor in Smart Energy Transport Cable under Tensile Loading
Due to the exponential growth in offshore renewable energies and structures such as floating offshore wind turbines and wave power converters, the research and engineering in this field is experiencing exceptional development. This emergence of offshore renewable energy requires power cables which are usually made up of copper to transport this energy ashore. These power cables are critical structures that must withstand harsh environmental conditions, handling, and shipping, at high seas which can cause copper wires to deform well above the limit of proportionality and consequently break. Copper, being an excellent electric conductor, has, however, very weak mechanical properties. If plasticity propagates inside copper not only will the mechanical properties be affected, but the electrical properties are also disrupted. Constantly monitoring such large-scale structures can be carried out by providing continuous strain using fiber-optic sensors (FOSs). The embedding of optical fibers within the cables (not within the phase) is practiced. Nevertheless, these optical fibers are first introduced into a cylinder of larger diameter than the optical fiber before this same fiber is embedded within the insulator surrounding the phases. Therefore, this type of embedding can in no way give a precise idea of the true deformation of the copper wires inside the phase. In this article, a set of numerical simulations are carried-out on a single phase (we are not yet working on the whole cable) with the aim of conceptualizing the placement of FOSs that will monitor strain and temperature within the conductor. It is well known that copper wire must never exceed temperatures above 90 °C, as this will result in shutdown of the whole system and therefore result in heavy maintenance, which would be a real catastrophe, economically speaking. This research explores the option of embedding sensors in several areas of the phase and how this can enable obtaining strain values that are representative of what really is happening in the conductor. It is, therefore, the primary objective of the current preliminary model to try to prove that the principle of embedding sensors in between copper wires can be envisaged, in particular to obtain an accurate idea about strain tensor of helical ones (multi-parameter strain sensing). The challenge is to ensure that they are not plastically deformed and hence able to transport electricity without exceeding or even becoming closer to 90 °C (fear of shutdown). The research solely focuses on mechanical aspects of the sensors. There are certainly some others, pertaining to sensors physics, instrumentation, and engineering, that are of prime importance, too. The upstream strategy of this research is to come up with a general concept that can be refined later by including, step by step, all the aspects listed above.
- Open Access
Numerical Simulation of Aging by Water-Trees of XPLE Insulator Used in a Single Hi-Voltage Phase of Smart Composite Power Cables for Offshore Farms
Submarine power cables are expected to last 20 years without maintenance to be considered technologically reliable enough and economically beneficial. One of the main issues facing this target is the development of what is called commonly water-trees (nanometer-sized flaws filled with residual humidity), that form within XLPE (cross-linked Polyethylene) insulators and then migrate towards copper, thus leading to its corrosion and further to possible shut-down. Water trees are resulting from the coalescence of nanovoids filled with residual humidity that migrate towards copper under the combined effects of electrical forces and plastic deformation. The nanovoids are originated during manufacturing, shipping, handling and embedding in deep seas. The formation of these nanovoids leads to the degradation of the service lifetime of submarine power cables. Current research is intended to come up with a way to go a little further towards the generalization of coalescence of n nanovoids. In the perspective of multi-physics modeling, a preliminary 3D finite element model was built. Although water voids are distributed randomly inside XLPE, in this study, two extreme cases where the voids are present parallel and perpendicular to the copper surface, were considered for simplification. This will enable checking the electric field effect on neighbouring voids, in both cases as well as the influence of the proximity of the conductor on the plasticity of voids, that further leads to their coalescence. It is worthwhile to note that assessing water-trees formation and propagation through an experimental campaign of ageing tests may extend over decades. It would therefore be an exceptional opportunity to be able to get insight into this mechanism through numerical modeling that needs a much shorter time. The premilinary model suggested is expected to be extended in the future so that to include more variables (distribution and shapes of nano-voids, water pressure, molecular modeling, electric discharge.
Open AccessNumerical Simulation of Aging by Water-Trees of XPLE Insulator Used in a Single Hi-Voltage Phase of Smart Composite Power Cables for Offshore Farms
Submarine power cables are expected to last 20 years without maintenance to be considered technologically reliable enough and economically beneficial. One of the main issues facing this target is the development of what is called commonly water-trees (nanometer-sized flaws filled with residual humidity), that form within XLPE (cross-linked Polyethylene) insulators and then migrate towards copper, thus leading to its corrosion and further to possible shut-down. Water trees are resulting from the coalescence of nanovoids filled with residual humidity that migrate towards copper under the combined effects of electrical forces and plastic deformation. The nanovoids are originated during manufacturing, shipping, handling and embedding in deep seas. The formation of these nanovoids leads to the degradation of the service lifetime of submarine power cables. Current research is intended to come up with a way to go a little further towards the generalization of coalescence of n nanovoids. In the perspective of multi-physics modeling, a preliminary 3D finite element model was built. Although water voids are distributed randomly inside XLPE, in this study, two extreme cases where the voids are present parallel and perpendicular to the copper surface, were considered for simplification. This will enable checking the electric field effect on neighbouring voids, in both cases as well as the influence of the proximity of the conductor on the plasticity of voids, that further leads to their coalescence. It is worthwhile to note that assessing water-trees formation and propagation through an experimental campaign of ageing tests may extend over decades. It would therefore be an exceptional opportunity to be able to get insight into this mechanism through numerical modeling that needs a much shorter time. The premilinary model suggested is expected to be extended in the future so that to include more variables (distribution and shapes of nano-voids, water pressure, molecular modeling, electric discharge.