Abdelghani Matine
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Abdelghani Matine has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Monssef Drissi-Habti
Department of Components and Systems, Université Gustave Eiffel, 77447 Marne-la-Vallée, France
2 shared publications - Fouad Ech-Cheikh
COSYS Department, Université Gustave Eiffel, F-77447 Marne-la-Vallée, France
1 shared publication
Latest Publications
- Open Access
Preliminary Multiphysics Modeling of Electric High-Voltage Cable of Offshore Wind-Farms
During manufacture, handling, transportation, installation and operation, mechanical overstress can affect the electrical and thermal properties of the conductor. As the wires in general are made of copper, which is a very plastically deforming material, these stresses will gradually generate plastic deformations of the copper until the wires start to fail. The objective of this article is to study, by numerical modeling (using Comsol and Abaqus), the impact of damage mechanisms on the electrical and thermal properties of a submarine cable phase. The influence of plasticity and gradual copper wire failure on the physical behavior (electric and thermal) of the phase was assessed. The heat differences between a healthy conductor vs. a damaged one (either deformed plastically and/or with failed wires) derived from the numerical model may be an accurate indicator of the level of damage of wires, thus furthering advanced warning before being obliged to stop the exploitation because a mandatory heavy maintenance of the cables must be scheduled. Note that this can also be achieved by using an optical fiber as a sensor for structural health monitoring. This study will then make it possible to evaluate the impact of the modification of the resistance on the thermal behavior of the cable. All of these simulations will be carried out on one phase of a 36 kV 120 mm² copper submarine cable. Colloquially these are called “copper cables”, meaning cables with Cu conductors (120 mm2 is the smallest conductor cross-section for array cables, which are usually 3-phase cables).
Open AccessPreliminary Multiphysics Modeling of Electric High-Voltage Cable of Offshore Wind-Farms
During manufacture, handling, transportation, installation and operation, mechanical overstress can affect the electrical and thermal properties of the conductor. As the wires in general are made of copper, which is a very plastically deforming material, these stresses will gradually generate plastic deformations of the copper until the wires start to fail. The objective of this article is to study, by numerical modeling (using Comsol and Abaqus), the impact of damage mechanisms on the electrical and thermal properties of a submarine cable phase. The influence of plasticity and gradual copper wire failure on the physical behavior (electric and thermal) of the phase was assessed. The heat differences between a healthy conductor vs. a damaged one (either deformed plastically and/or with failed wires) derived from the numerical model may be an accurate indicator of the level of damage of wires, thus furthering advanced warning before being obliged to stop the exploitation because a mandatory heavy maintenance of the cables must be scheduled. Note that this can also be achieved by using an optical fiber as a sensor for structural health monitoring. This study will then make it possible to evaluate the impact of the modification of the resistance on the thermal behavior of the cable. All of these simulations will be carried out on one phase of a 36 kV 120 mm² copper submarine cable. Colloquially these are called “copper cables”, meaning cables with Cu conductors (120 mm2 is the smallest conductor cross-section for array cables, which are usually 3-phase cables).
- Open Access
On-Coupling Mechanical, Electrical and Thermal Behavior of Submarine Power Phases
Floating offshore renewable energies (OREs), such as offshore floating wind turbines (wind energy) or wave power (wave and wave energy), are increasingly in demand. Submarine cables that transmit the energy produced from offshore farms all the way to onshore stations are critical structures that must be able to work perfectly over 20 years without any maintenance. In order to reduce the significant costs associated with electrical cables, it is important to optimize the dimensioning of the components of these cables, or to develop structural monitoring techniques that target zero and/or minimum maintenance over their lifespan. In this paper, we FEM of the impact of damage mechanisms of the conductor part of a submarine power phase on its mechanical, electrical, and thermal behavior. The main damage mechanisms are local plasticity and wire failure. The first mechanical study made it possible to obtain the elasto-plastic behavior of the conductor. The electrical study took into consideration the deformed geometry of the conductor in the elasto-plastic domain, as well as the non-homogeneous distribution of the electrical conductivity of the conductor. Their influence on the electrical resistance of the conductor was then analyzed. Finally, we studied the impact of plasticity and conductor failure on the thermal behavior of the phase. The temperature differences obtained in the numerical analysis of this work may be used further to help preventive and curative maintenance of the cables, for example, by using an optical fiber as sensor for structural health monitoring.
Open AccessOn-Coupling Mechanical, Electrical and Thermal Behavior of Submarine Power Phases
Floating offshore renewable energies (OREs), such as offshore floating wind turbines (wind energy) or wave power (wave and wave energy), are increasingly in demand. Submarine cables that transmit the energy produced from offshore farms all the way to onshore stations are critical structures that must be able to work perfectly over 20 years without any maintenance. In order to reduce the significant costs associated with electrical cables, it is important to optimize the dimensioning of the components of these cables, or to develop structural monitoring techniques that target zero and/or minimum maintenance over their lifespan. In this paper, we FEM of the impact of damage mechanisms of the conductor part of a submarine power phase on its mechanical, electrical, and thermal behavior. The main damage mechanisms are local plasticity and wire failure. The first mechanical study made it possible to obtain the elasto-plastic behavior of the conductor. The electrical study took into consideration the deformed geometry of the conductor in the elasto-plastic domain, as well as the non-homogeneous distribution of the electrical conductivity of the conductor. Their influence on the electrical resistance of the conductor was then analyzed. Finally, we studied the impact of plasticity and conductor failure on the thermal behavior of the phase. The temperature differences obtained in the numerical analysis of this work may be used further to help preventive and curative maintenance of the cables, for example, by using an optical fiber as sensor for structural health monitoring.