EWErjun Wu

Erjun Wu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Erjun Wu has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Numerical Investigation of the Sound Insulation Performance of Sandwich RC Slabs with Interlayer Inclined Rebar Connectors

    by Erjun Wu, Jianxiang Wang, Yonghao Wang

    To balance load-bearing capacity and acoustic insulation, this study proposes a sandwich reinforced concrete (RC) slab with W-shaped interlayer inclined rebar connectors and investigates their influence on acoustic bridging. A three-dimensional vibro-acoustic finite element modeling approach was adapted to analyze airborne sound insulation and impact sound pressure levels in the frequency domain and was validated against experimental results. Parametric analyses were then conducted to evaluate the effects of connector number, connector geometry, anchorage-end treatment, and core-layer parameters. The results revealed distinct frequency-dependent behavior. The introduction of connectors produced a stable dip in airborne sound insulation near 400 Hz and a pronounced impact-sound peak within 200–400 Hz, both associated with connector-controlled coupled characteristic frequencies. Increasing the number of connectors strengthened interlayer stiffness coupling and intensified acoustic bridging in these frequency ranges. By contrast, optimizing the connector structure or introducing a compliant end layer reduced coupling and improved acoustic insulation. Overall, acoustic performance can be improved by reducing the equivalent coupling stiffness of the connectors, enhancing energy dissipation at the connector ends, and appropriately selecting the core-layer parameters. These measures help suppress the characteristic-frequency response and improve mid- to high-frequency sound insulation.

  • Open Access

    Numerical Study on the Vibration Characteristics of Concrete Sandwich Panels With Diagonal Bar Connectors

    by Abdelrahman Ali, Erjun Wu

    This paper presents a three‐dimensional finite element investigation of the vibration characteristics of concrete sandwich panels with diagonal bar connectors, focusing on how connector design influences natural frequencies and mode shapes to improve sound insulation. Using ABAQUS, we developed a numerical model incorporating concrete wythes, an expanded polystyrene (EPS) foam core, and dumbbell‐shaped hybrid glass fiber‐reinforced polymer (GFRP)‐steel connectors. A parametric study examined the effects of boundary conditions, connector inclination angle (30°, 45°, 60°), connector material (hybrid GFRP‐steel vs. GFRP alone), core material (graphite polystyrene [GPS] vs. EPS foam), connector distribution, and panel aspect ratio (2.8:1 vs. 1:1). The fixed‐fixed boundary condition, yielding a fundamental frequency of 56.03 Hz, was selected as the baseline for parametric comparison due to its theoretical alignment and mode shape stability. Diagonal connectors substantially increased structural stiffness, with the 45° inclined configuration achieving a 37.9% increase in fundamental frequency over unstiffened panels, outperforming vertical connectors (29.6% increase). Shallower angles (30°) produced the highest frequencies (58.52 Hz), while steeper angles (60°) yielded lower frequencies (54.49 Hz); mode shape analysis revealed 45° as a transitional angle where bending‐torsion coupling occurs. Although the 30° configuration maximizes frequency, the 45° configuration is recommended for practical applications because it balances stiffness enhancement with regular mode shapes. Hybrid GFRP‐steel connectors produced 6.4% higher frequencies than GFRP alone, demonstrating that increased stiffness outweighs steel’s mass penalty. Core material was the most influential parameter: GPS foam ( E = 20 MPa, ρ = 23.5 kg/m 3 ) produced frequencies up to 24.7% higher than EPS foam ( E = 5 MPa, ρ = 35 kg/m 3 ) in higher modes. Square panels (1:1) exhibited fundamental frequencies 103% higher than those of rectangular panels (2.8:1). Connector and core optimization can shift natural frequencies above the critical excitation ranges (50–60 Hz) from traffic and machinery, enabling resonance avoidance without adding mass, a sustainable approach consistent with lightweight construction demands. While direct sound transmission loss calculations are beyond the scope of this purely structural modal analysis, the results suggest that shifting natural frequencies away from common excitation bands may reduce resonance‐induced sound transmission. This provides a theoretical basis for future vibroacoustic investigations aimed at quantifying the sound insulation benefits of optimized connector configurations.

  • Open Access

    Effect of reinforcement ratios on shear behavior of concrete beams strengthened with CFRP sheets

    by Bashir H. Osman, Erjun Wu, Bohai Ji, Suhaib S. Abdulhameed

    Carbon fiber reinforcement polymer (CFRP) sheets are the most commonly materials that are used to strengthen reinforced concrete members due to high strength-to-weight ratio, excellent mechanical strength, and good fatigue properties. In this research program seven reinforced concrete beams were tested under four points loading with different shear span-to-depth ratios avd <!--mathContainer--> <!--Loading Mathjax--> , longitudinal and vertical reinforcement ratios. A numerical analysis using ANSYS software program was done by modeling 27 reinforced concrete beams with and without CFRP sheets. The beam dimensions, concrete strength, strengthening configuration of the CFRP sheets (full wrapped, U shape, and side bonding), and FRP thickness were considered as the main parameters of the numerical analysis. A comparison between the finite element (FE) results and the ACI standard code demonstrated the validity of the computational models in capturing the structural response of FRP contribution with variation varied from (10–16)%, (12–20)% and (13–19)% for full wrapping, U-jacketing, and side bonding, respectively. The finite element models were able to accurately predict the load capacities for the simulated RC beams strengthened in shear with CFRP composites. The results obtained using ANSYS finite element are relatively identical to the experimental ones, showing reasonable agreement with variation not more than 5% in all the specimens.


  • Experimental study on column underpinning joints with inclined steel bars

    by Erjun Wu, Ning Dong, Kaijun Yuan

    Column underpinning joints play an important role in monolithic moving, jacking up and renovation or reinforcing of buildings. However, existing methods of improving the bearing capacity of joints usually cause damage to columns and the constructions are complex. A new column underpinning method with inclined rectangular ribbed steel bars was thus developed. Six specimens were tested experimentally under vertical static load. The inclination angle and the number of inclined steel bars were considered as the main parameters. Tests were carried out to study the mechanical performance of the column underpinning joints, especially bearing capacity. The results indicate that, compared with a specimen without inclined bars, the addition of inclined bars in joints improves the bearing capacity by a maximum of 143·7%. Analysis revealed that the bearing capacity of joints with inclined bars is mainly composed of three parts – the vertical component of force in inclined bars, partial cohesion strength and the shear strength resulting from friction at the interface between new and old concrete. The failure of all specimens was sliding failure at the interface, except for one specimen that failed due to crushing of the columns.


  • Repair technique of pre-cracked reinforced concrete (RC) beams with transverse openings strengthened with steel plate under sustained load

    by Bashir H. Osman, Erjun Wu, Ji Bohai, Mohammad Abdallah

    This paper presents a repairing technique of the steel plate that effectively strengthen RC members, control both the failure modes and the stress distribution around the beam chords and enhance the serviceability of pre-cracked RC beams with openings. Furthermore, to evaluate the usage of a temporary pre-stressed force that was applied on the RC beam so as to close all of the presence shear cracks before the steel plate application. Two un-strengthened control beams, five beams that were pre-cracked before the application of the steel plate, and one beam that was strengthened without pre-cracking were tested. Cracking was first induced, followed by repair using various strengthening technique, and then the beams were tested to failure. The advantages of the shear strengthening of RC beams that were obtained using this technique are based on the closing of all the existing cracks around the openings via epoxy injection. The results show that both the pre-existing damage level and the steel plate strengthening have a significant effect on strengthening effectiveness and failure mode at the ultimate strength. An analytical equation for predicting the shear strength of pre-damaged RC beams with circular openings was then proposed, and the obtained results later compared with those from the tests, results were in accordance.