Radoslav Bortel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Radoslav Bortel has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Pavel Sovka
Dept. of Circuit Theory, Czech Technical University, Faculty of Electrical Engineering, Prague, Czech Republic
8 shared publications- Lukas Vojtech
Department of Telecommunication Engineering, Faculty of Electrical Engineering, Czech Technical University in Prague, Technicka 2, 166 27 Prague, Czech Republic
5 shared publications - Marek Neruda
Czech Technical University in Prague, Technicka 2, Prague 6, Czech Republic
4 shared publications Jan Sebek
Department of Electrical and Computer Engineering, Kansas State University, 1701D Platt st., Manhattan, KS, 66506, USA
3 shared publicationsJiri Skapa
3 shared publications- Punit Prakash
Department of Biomedical Engineering, The George Washington University
3 shared publications
Latest Publications
- 9 July 2019
- Published by Wiley in Medical Physics
- Vol. 46 (10) , 4291-4303
Broadband lung dielectric properties over the ablative temperature range: Experimental measurements and parametric models
Purpose: Computational models of microwave tissue ablation are widely used to guide the development of ablation devices, and are increasingly being used for the development of treatment planning and monitoring platforms. Knowledge of temperature‐dependent dielectric properties of lung tissue is essential for accurate modeling of microwave ablation (MWA) of the lung.Methods: We employed the open‐ended coaxial probe method, coupled with a custom tissue heating apparatus, to measure dielectric properties of ex vivo porcine and bovine lung tissue at temperatures ranging between 31 and 150 C, over the frequency range 500 MHz to 6 GHz. Furthermore, we employed numerical optimization techniques to provide parametric models for characterizing the broadband temperature‐dependent dielectric properties of tissue, and their variability across tissue samples, suitable for use in computational models of microwave tissue ablation.Results: Rapid decreases in both relative permittivity and effective conductivity were observed in the temperature range from 94 to 108 C. Over the measured frequency range, both relative permittivity and effective conductivity were suitably modeled by piecewise linear functions [root mean square error (RMSE) = 1.0952 for permittivity and 0.0650 S/m for conductivity]. Detailed characterization of the variability in lung tissue properties was provided to enable uncertainty quantification of models of MWA.Conclusions: The reported dielectric properties of lung tissue, and parametric models which also capture their distribution, will aid the development of computational models of microwave lung ablation.
- 9 July 2019
- Published by Wiley in Medical Physics
- Vol. 46 (10) , 4291-4303
Broadband lung dielectric properties over the ablative temperature range: Experimental measurements and parametric models
Purpose: Computational models of microwave tissue ablation are widely used to guide the development of ablation devices, and are increasingly being used for the development of treatment planning and monitoring platforms. Knowledge of temperature‐dependent dielectric properties of lung tissue is essential for accurate modeling of microwave ablation (MWA) of the lung.Methods: We employed the open‐ended coaxial probe method, coupled with a custom tissue heating apparatus, to measure dielectric properties of ex vivo porcine and bovine lung tissue at temperatures ranging between 31 and 150 C, over the frequency range 500 MHz to 6 GHz. Furthermore, we employed numerical optimization techniques to provide parametric models for characterizing the broadband temperature‐dependent dielectric properties of tissue, and their variability across tissue samples, suitable for use in computational models of microwave tissue ablation.Results: Rapid decreases in both relative permittivity and effective conductivity were observed in the temperature range from 94 to 108 C. Over the measured frequency range, both relative permittivity and effective conductivity were suitably modeled by piecewise linear functions [root mean square error (RMSE) = 1.0952 for permittivity and 0.0650 S/m for conductivity]. Detailed characterization of the variability in lung tissue properties was provided to enable uncertainty quantification of models of MWA.Conclusions: The reported dielectric properties of lung tissue, and parametric models which also capture their distribution, will aid the development of computational models of microwave lung ablation.
- Open Access
- 14 August 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (8) , e0201900
Suppression of overlearning in independent component analysis used for removal of muscular artifacts from electroencephalographic records
This paper addresses the overlearning problem in the independent component analysis (ICA) used for the removal of muscular artifacts from electroencephalographic (EEG) records. We note that for short EEG records with high number of channels the ICA fails to separate artifact-free EEG and muscular artifacts, which has been previously attributed to the phenomenon called overlearning. We address this problem by projecting an EEG record into several subspaces with a lower dimension, and perform the ICA on each subspace separately. Due to a reduced dimension of the subspaces, the overlearning is suppressed, and muscular artifacts are better separated. Once the muscular artifacts are removed, the signals in the individual subspaces are combined to provide an artifact free EEG record. We show that for short signals and high number of EEG channels our approach outperforms the currently available ICA based algorithms for muscular artifact removal. The proposed technique can efficiently suppress ICA overlearning for short signal segments of high density EEG signals.
- 14 August 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (8) , e0201900
Open AccessSuppression of overlearning in independent component analysis used for removal of muscular artifacts from electroencephalographic records
This paper addresses the overlearning problem in the independent component analysis (ICA) used for the removal of muscular artifacts from electroencephalographic (EEG) records. We note that for short EEG records with high number of channels the ICA fails to separate artifact-free EEG and muscular artifacts, which has been previously attributed to the phenomenon called overlearning. We address this problem by projecting an EEG record into several subspaces with a lower dimension, and perform the ICA on each subspace separately. Due to a reduced dimension of the subspaces, the overlearning is suppressed, and muscular artifacts are better separated. Once the muscular artifacts are removed, the signals in the individual subspaces are combined to provide an artifact free EEG record. We show that for short signals and high number of EEG channels our approach outperforms the currently available ICA based algorithms for muscular artifact removal. The proposed technique can efficiently suppress ICA overlearning for short signal segments of high density EEG signals.
- 5 July 2016
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 33 (1) , 51-60
Analysis of minimally invasive directional antennas for microwave tissue ablation
Purpose: Microwave ablation (MWA) applicators capable of creating directional heating patterns offer the potential of simplifying treatment of targets in proximity to critical structures and avoiding the need for piercing the tumour volume. This work reports on improved directional MWA antennas with the objectives of minimising device diameter for percutaneous use (≤ ∼13 gauge) and yielding larger ablation zones. Methods: Two directional MWA antenna designs, with a modified monopole radiating element and spherical and parabolic reflectors are proposed. A 3D-coupled electromagnetic heat transfer with temperature-dependent material properties was implemented to characterise MWA at 40 and 77 W, for 5 and 10 min. Simulations were also used to assess antenna impedance matching within liver, kidney, lung, bone and brain tissue. The two antenna designs were fabricated and experimentally evaluated with ablations in ex vivo tissue at the two power levels and treatment durations (n = 5 repetitions for each group). Results: The computed specific absorption rate (SAR) patterns for both antennas were similar, although simulations indicated slightly greater forward penetration for the parabolic antenna. Based on simulations for antennas inserted within different tissues, the proposed antenna design appears to offer good impedance matching for a variety of tissue types. Experiments in ex vivo tissue showed radial ablation depths of 19 ± 0.9 mm in the forward direction for the applicator with spherical reflector and 18.7 ± 0.7 mm for the applicator with parabolic reflector. Conclusion: These results suggest the applicator may be suitable for creating localised directional ablation zones for treating small and medium-sized targets with a percutaneous approach.
- 5 July 2016
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 33 (1) , 51-60
Analysis of minimally invasive directional antennas for microwave tissue ablation
Purpose: Microwave ablation (MWA) applicators capable of creating directional heating patterns offer the potential of simplifying treatment of targets in proximity to critical structures and avoiding the need for piercing the tumour volume. This work reports on improved directional MWA antennas with the objectives of minimising device diameter for percutaneous use (≤ ∼13 gauge) and yielding larger ablation zones. Methods: Two directional MWA antenna designs, with a modified monopole radiating element and spherical and parabolic reflectors are proposed. A 3D-coupled electromagnetic heat transfer with temperature-dependent material properties was implemented to characterise MWA at 40 and 77 W, for 5 and 10 min. Simulations were also used to assess antenna impedance matching within liver, kidney, lung, bone and brain tissue. The two antenna designs were fabricated and experimentally evaluated with ablations in ex vivo tissue at the two power levels and treatment durations (n = 5 repetitions for each group). Results: The computed specific absorption rate (SAR) patterns for both antennas were similar, although simulations indicated slightly greater forward penetration for the parabolic antenna. Based on simulations for antennas inserted within different tissues, the proposed antenna design appears to offer good impedance matching for a variety of tissue types. Experiments in ex vivo tissue showed radial ablation depths of 19 ± 0.9 mm in the forward direction for the applicator with spherical reflector and 18.7 ± 0.7 mm for the applicator with parabolic reflector. Conclusion: These results suggest the applicator may be suitable for creating localised directional ablation zones for treating small and medium-sized targets with a percutaneous approach.
- 3 May 2016
- Published by Wiley in Medical Physics
- Vol. 43 (5) , 2649-2661
Sensitivity of microwave ablation models to tissue biophysical properties: A first step toward probabilistic modeling and treatment planning
Purpose: Computational models of microwave ablation (MWA) are widely used during the design optimization of novel devices and are under consideration for patient-specific treatment planning. The objective of this study was to assess the sensitivity of computational models of MWA to tissue biophysical properties. Methods: The Morris method was employed to assess the global sensitivity of the coupled electromagnetic–thermal model, which was implemented with the finite element method (FEM). The FEM model incorporated temperature dependencies of tissue physical properties. The variability of the model was studied using six different outputs to characterize the size and shape of the ablation zone, as well as impedance matching of the ablationantenna. Furthermore, the sensitivity results were statistically analyzed and absolute influence of each input parameter was quantified. A framework for systematically incorporating model uncertainties for treatment planning was suggested. Results: A total of 1221 simulations, incorporating 111 randomly sampled starting points, were performed. Tissue dielectric parameters, specifically relative permittivity, effective conductivity, and the threshold temperature at which they transitioned to lower values (i.e., signifying desiccation), were identified as the most influential parameters for the shape of the ablation zone and antenna impedance matching. Of the thermal parameters considered in this study, the nominal blood perfusion rate and the temperature interval across which the tissue changes phase were identified as the most influential. The latent heat of tissuewatervaporization and the volumetric heat capacity of the vaporized tissue were recognized as the least influential parameters. Based on the evaluation of absolute changes, the most important parameter (perfusion) had approximately 40.23 times greater influence on ablation area than the least important parameter (volumetric heat capacity of vaporized tissue). Another significant input parameter (permittivity) had 22.26 times higher influence on the deviation of ablation edge shape from a sphere than one of the less important parameters (latent heat of livertissuevaporization). Conclusions: Dielectric parameters, blood perfusion rate, and the temperature interval across which the tissue changes phase were found to have the most significant impact on MWA model outputs. The latent heat of tissuewatervaporization and the volumetric heat capacity of the vaporized tissue were recognized as the least influential parameters. Uncertainties in model outputs identified in this study can be incorporated to provide probabilistic maps of expected ablation outcome for patient-specific treatment planning.
- 3 May 2016
- Published by Wiley in Medical Physics
- Vol. 43 (5) , 2649-2661
Sensitivity of microwave ablation models to tissue biophysical properties: A first step toward probabilistic modeling and treatment planning
Purpose: Computational models of microwave ablation (MWA) are widely used during the design optimization of novel devices and are under consideration for patient-specific treatment planning. The objective of this study was to assess the sensitivity of computational models of MWA to tissue biophysical properties. Methods: The Morris method was employed to assess the global sensitivity of the coupled electromagnetic–thermal model, which was implemented with the finite element method (FEM). The FEM model incorporated temperature dependencies of tissue physical properties. The variability of the model was studied using six different outputs to characterize the size and shape of the ablation zone, as well as impedance matching of the ablationantenna. Furthermore, the sensitivity results were statistically analyzed and absolute influence of each input parameter was quantified. A framework for systematically incorporating model uncertainties for treatment planning was suggested. Results: A total of 1221 simulations, incorporating 111 randomly sampled starting points, were performed. Tissue dielectric parameters, specifically relative permittivity, effective conductivity, and the threshold temperature at which they transitioned to lower values (i.e., signifying desiccation), were identified as the most influential parameters for the shape of the ablation zone and antenna impedance matching. Of the thermal parameters considered in this study, the nominal blood perfusion rate and the temperature interval across which the tissue changes phase were identified as the most influential. The latent heat of tissuewatervaporization and the volumetric heat capacity of the vaporized tissue were recognized as the least influential parameters. Based on the evaluation of absolute changes, the most important parameter (perfusion) had approximately 40.23 times greater influence on ablation area than the least important parameter (volumetric heat capacity of vaporized tissue). Another significant input parameter (permittivity) had 22.26 times higher influence on the deviation of ablation edge shape from a sphere than one of the less important parameters (latent heat of livertissuevaporization). Conclusions: Dielectric parameters, blood perfusion rate, and the temperature interval across which the tissue changes phase were found to have the most significant impact on MWA model outputs. The latent heat of tissuewatervaporization and the volumetric heat capacity of the vaporized tissue were recognized as the least influential parameters. Uncertainties in model outputs identified in this study can be incorporated to provide probabilistic maps of expected ablation outcome for patient-specific treatment planning.
- Open Access
- 23 December 2015
- Published by VSB - Technical University of Ostrava in Advances in Electrical and Electronic Engineering
- Vol. 13 (5) , 484 - 490
GNSS/RFID Active Transponder Design
The paper describes a design of global navigation satellite system (GNSS)/Radio frequency identification (RFID) active transponder which is primarily designed for localization of objects as a part of localization system designated for efficient handling of situations with mass casualties. The precise localization is improved by differential GNSS. The block diagram of such GNSS/RFID active transponder is described including main operation procedures of the firmware. Measurement of the localization by algorithms of RTKLIB library and by algorithms of GNSS module is compared. Dynamic tests, i.e. GNSS/RFID active transponder placed in the moving car (50~kmph), and static tests, i.e. GNSS/RFID active transponder placed in the position for 15~min, are performed.
- 23 December 2015
- Published by VSB - Technical University of Ostrava in Advances in Electrical and Electronic Engineering
- Vol. 13 (5) , 484 - 490
Open AccessGNSS/RFID Active Transponder Design
The paper describes a design of global navigation satellite system (GNSS)/Radio frequency identification (RFID) active transponder which is primarily designed for localization of objects as a part of localization system designated for efficient handling of situations with mass casualties. The precise localization is improved by differential GNSS. The block diagram of such GNSS/RFID active transponder is described including main operation procedures of the firmware. Measurement of the localization by algorithms of RTKLIB library and by algorithms of GNSS module is compared. Dynamic tests, i.e. GNSS/RFID active transponder placed in the moving car (50~kmph), and static tests, i.e. GNSS/RFID active transponder placed in the position for 15~min, are performed.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 4-11
Design of RFID outdoor localization system: RFID locator for disaster management
This paper presents an RFID outdoor localization system that is able to localize hundreds of active transponders in the area of one square kilometer using three RFID receiving stations. The RFID outdoor locator is designed for the tracking of casualties during mass disasters. Active transponders are included in triage tags that are fastened to all casualties during the first wave of rescue operations. Direction of arrival of each transponder and GPS position of three receiving stations determine the position of each active transponder in the area. The location of the transponder is displayed on a mobile terminal in maps. The paper describes a design and simulations of such system. The precision of localization of realized prototypes of the system is measured. The results and applications using the proposed RFID outdoor locator are discussed.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 4-11
Design of RFID outdoor localization system: RFID locator for disaster management
This paper presents an RFID outdoor localization system that is able to localize hundreds of active transponders in the area of one square kilometer using three RFID receiving stations. The RFID outdoor locator is designed for the tracking of casualties during mass disasters. Active transponders are included in triage tags that are fastened to all casualties during the first wave of rescue operations. Direction of arrival of each transponder and GPS position of three receiving stations determine the position of each active transponder in the area. The location of the transponder is displayed on a mobile terminal in maps. The paper describes a design and simulations of such system. The precision of localization of realized prototypes of the system is measured. The results and applications using the proposed RFID outdoor locator are discussed.
- 1 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 168-171
UHF RFID tag design for disaster management
This paper deals with the Ultra High Frequency (UHF) Radio Frequency Identification (RFID) tag design as a part of RFID localization system primarily designated for mass disasters. The design of RFID tag considers many casualties in an area of hundreds square meters, human body impedance, battery lifetime, maximal output power, resistant encapsulation etc. All requirements are taken into account in the design of several versions of RFID tag and the best one is chosen. Subsequently the design is manufactured and measured. Results show the designed RFID tag prototype is suitable for application in a disaster management.
- 1 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 168-171
UHF RFID tag design for disaster management
This paper deals with the Ultra High Frequency (UHF) Radio Frequency Identification (RFID) tag design as a part of RFID localization system primarily designated for mass disasters. The design of RFID tag considers many casualties in an area of hundreds square meters, human body impedance, battery lifetime, maximal output power, resistant encapsulation etc. All requirements are taken into account in the design of several versions of RFID tag and the best one is chosen. Subsequently the design is manufactured and measured. Results show the designed RFID tag prototype is suitable for application in a disaster management.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 586-589
Outdoor localization technique using active RFID technology aimed for security and disaster management applications
With the implementation of the principle of the Internet of Things raises demands for new services as well as technical requirements that enable their implementation. One of the fields is the localization of wounded in mass disasters. Currently, the identification is performed by paper / plastic triage tags, which are used to label wounded victim at first contact with rescue unit based on the state of the causality. Automatic identification using active RFID technology is in such a case a solution which permits remote technically sophisticated surveillance of the situation. It is advantageous to use active RFID tags as a low-power transmitter, which is an immense advantage comparison with GPS technology. Lifetime of such tag can be several months. Managed active RFID tags can localize wounded objects within the range of a few hundred meters in free space and indicate the degree of severity of the injury of individual causalities. RFID readers, i.e. locators placed in that area, evaluate the direction of arrival of each tag and transmit obtained information to the computer system, which calculates the position of each RFID tag using sophisticated signal processing methods. This information can be displayed in a specific map including classification of tags, their movement or history. This paper focuses on the testing and experimental verification of such a system. The results of the experiment verify the concept of an RFID locator with achieved accuracy of 2.1 m in the area of 100 × 100 m.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 586-589
Outdoor localization technique using active RFID technology aimed for security and disaster management applications
With the implementation of the principle of the Internet of Things raises demands for new services as well as technical requirements that enable their implementation. One of the fields is the localization of wounded in mass disasters. Currently, the identification is performed by paper / plastic triage tags, which are used to label wounded victim at first contact with rescue unit based on the state of the causality. Automatic identification using active RFID technology is in such a case a solution which permits remote technically sophisticated surveillance of the situation. It is advantageous to use active RFID tags as a low-power transmitter, which is an immense advantage comparison with GPS technology. Lifetime of such tag can be several months. Managed active RFID tags can localize wounded objects within the range of a few hundred meters in free space and indicate the degree of severity of the injury of individual causalities. RFID readers, i.e. locators placed in that area, evaluate the direction of arrival of each tag and transmit obtained information to the computer system, which calculates the position of each RFID tag using sophisticated signal processing methods. This information can be displayed in a specific map including classification of tags, their movement or history. This paper focuses on the testing and experimental verification of such a system. The results of the experiment verify the concept of an RFID locator with achieved accuracy of 2.1 m in the area of 100 × 100 m.
- Open Access
- 19 November 2013
- Published by VSB - Technical University of Ostrava in Advances in Electrical and Electronic Engineering
- Vol. 11 (5) , 410 - 414
Wearable Textile Electrodes for ECG Measurement
Wearable Textile Electrodes for ECG Measurement
- 19 November 2013
- Published by VSB - Technical University of Ostrava in Advances in Electrical and Electronic Engineering
- Vol. 11 (5) , 410 - 414
Open AccessWearable Textile Electrodes for ECG Measurement
Wearable Textile Electrodes for ECG Measurement
- 11 October 2013
- Published by Elsevier in Signal Processing
- Vol. 96, 310-314
Approximation of the null distribution of the multiple coherence estimated with segment overlapping
- 11 October 2013
- Published by Elsevier in Signal Processing
- Vol. 96, 310-314
Approximation of the null distribution of the multiple coherence estimated with segment overlapping