Archita Hati
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Archita Hati has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Craig W. Nelson
National Institute of Standards and Technology, Boulder, CO, USA
10 shared publications - Marco Pomponio
National Institute of Standards and Technology, Boulder, CO, USA
8 shared publications Craig W. Nelson
Time and Frequency Division, National Institute of Standards and Technology, Boulder, CO/USA
5 shared publications- Nicholas V. Nardelli
National Institute of Standards and Technology
4 shared publications - Tara Michele Fortier
National Institute of Standards and Technology 325 Broadway 80305 Boulder Colorado USA
4 shared publications - Andrew D. Ludlow
National Institute of Standards and Technology, Boulder, CO, USA
3 shared publications
Latest Publications
- Open Access
- 9 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 6, 44-52
Flicker Suppressed Direct Digital Phase and Amplitude Noise Measurements
In this article, we present a new and innovative technique that reduces the close-to-the-carrier noise floors in direct digital measurement systems. For a 100 MHz carrier, with respect to our previous state-of-the-art direct digital measurement system, we report a noise floor reduction of over 35 dB in the flicker region for both phase and amplitude noise, and greater than a factor of 20 improvement in Allan deviation. Moreover, this technique reduces the impact of analog-to-digital converter’s voltage reference noise and aperture jitter on the system noise floor, allowing the construction of multichannel systems for timescale applications while maintaining the same performance levels. We call this new method flicker-suppressed direct digital. At 100 MHz for a single channel, we report single sideband residual phase noise floor of ℒ(1 Hz) = −147 dBc/Hz, with a flicker corner of about 0.03 Hz. The single channel residual Allan deviation noise floor for the same carrier is less than 1.3×10−16 at 1 second averaging time (τ ) with a 0.5 Hz bandwidth. Further improvement can be achieved with the use of cross-correlation techniques. To our knowledge, this represents the lowest flicker noise and Allan deviation performance ever reported for a digital measurement system.
- 9 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 6, 44-52
Open AccessFlicker Suppressed Direct Digital Phase and Amplitude Noise Measurements
In this article, we present a new and innovative technique that reduces the close-to-the-carrier noise floors in direct digital measurement systems. For a 100 MHz carrier, with respect to our previous state-of-the-art direct digital measurement system, we report a noise floor reduction of over 35 dB in the flicker region for both phase and amplitude noise, and greater than a factor of 20 improvement in Allan deviation. Moreover, this technique reduces the impact of analog-to-digital converter’s voltage reference noise and aperture jitter on the system noise floor, allowing the construction of multichannel systems for timescale applications while maintaining the same performance levels. We call this new method flicker-suppressed direct digital. At 100 MHz for a single channel, we report single sideband residual phase noise floor of ℒ(1 Hz) = −147 dBc/Hz, with a flicker corner of about 0.03 Hz. The single channel residual Allan deviation noise floor for the same carrier is less than 1.3×10−16 at 1 second averaging time (τ ) with a 0.5 Hz bandwidth. Further improvement can be achieved with the use of cross-correlation techniques. To our knowledge, this represents the lowest flicker noise and Allan deviation performance ever reported for a digital measurement system.
- Open Access
- 8 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 5, 127-134
Radio Frequency From Optical With Instabilities Below 10-15-Generation and Measurement
This paper presents a frequency synthesis that achieves exceptional stability by transferring optical signals to the radio frequency (RF) domain at 100 MHz. We describe and characterize two synthesis chains composed of a cryogenic silicon cavity-stabilized laser at 1542 nm and an ultra-low expansion (ULE) glass cavity at 1157 nm, both converted to 10 GHz signals via Ti:Sapphire and Er/Yb:glass optical frequency combs (OFCs). The 10 GHz microwave outputs are further divided down to 100 MHz using a commercial microwave prescaler, which exhibits a residual frequency instability of$\sigma _{y}({1}~\text {s})\lt {10}^{-{15}}$ and low 10-18 level at a few thousand seconds. Measurements are performed using a newly developed custom ultra-low-noise digital measurement system and are compared to the carrier-suppression technique. The new system enables high-sensitivity evaluation across the entire synthesis chain, from the optical and microwave heterodynes as well as the direct RF signals. Results show an absolute instability of${\sigma }_{y}({1}~\text {s})~\approx ~{4.7}\times {10}^{-{16}}$ at 100 MHz. This represents the first demonstration of such low instability at 100 MHz, corresponding to a phase noise of −140 dBc/Hz at a 1 Hz offset and significantly surpassing earlier systems. These advancements open new opportunities for precision metrology and timing systems.- 8 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 5, 127-134
Open AccessRadio Frequency From Optical With Instabilities Below 10-15-Generation and Measurement
This paper presents a frequency synthesis that achieves exceptional stability by transferring optical signals to the radio frequency (RF) domain at 100 MHz. We describe and characterize two synthesis chains composed of a cryogenic silicon cavity-stabilized laser at 1542 nm and an ultra-low expansion (ULE) glass cavity at 1157 nm, both converted to 10 GHz signals via Ti:Sapphire and Er/Yb:glass optical frequency combs (OFCs). The 10 GHz microwave outputs are further divided down to 100 MHz using a commercial microwave prescaler, which exhibits a residual frequency instability of$\sigma _{y}({1}~\text {s})\lt {10}^{-{15}}$ and low 10-18 level at a few thousand seconds. Measurements are performed using a newly developed custom ultra-low-noise digital measurement system and are compared to the carrier-suppression technique. The new system enables high-sensitivity evaluation across the entire synthesis chain, from the optical and microwave heterodynes as well as the direct RF signals. Results show an absolute instability of${\sigma }_{y}({1}~\text {s})~\approx ~{4.7}\times {10}^{-{16}}$ at 100 MHz. This represents the first demonstration of such low instability at 100 MHz, corresponding to a phase noise of −140 dBc/Hz at a 1 Hz offset and significantly surpassing earlier systems. These advancements open new opportunities for precision metrology and timing systems. - Open Access
Radio Frequency from Optical with Instabilities below $10^{-15}$- Generation and Measurement
This paper presents a frequency synthesis that achieves exceptional stability by transferring optical signals to the radio frequency (RF) domain at 100 MHz. We describe and characterize two synthesis chains composed of a cryogenic silicon cavity-stabilized laser at 1542 nm and an ultra-low expansion (ULE) glass cavity at 1157 nm, both converted to 10 GHz signals via Ti:Sapphire and Er/Yb:glass optical frequency combs (OFCs). The 10 GHz microwave outputs are further divided down to 100 MHz using a commercial microwave prescaler, which exhibits a residual frequency instability of $σ_y(1~\text{s})<10^{-15}$ and low $10^{-18}$ level at a few thousand seconds. Measurements are performed using a newly developed custom ultra-low-noise digital measurement system and are compared to the carrier-suppression technique. The new system enables high-sensitivity evaluation across the entire synthesis chain, from the optical and microwave heterodynes as well as the direct RF signals. Results show an absolute instability of $σ_y(1~\text{s})~\approx~4.7\times10^{-16}$ at 100 MHz. This represents the first demonstration of such low instability at 100 MHz, corresponding to a phase noise of -140 dBc/Hz at a 1 Hz offset and significantly surpassing earlier systems. These advancements open new opportunities for precision metrology and timing systems.Open AccessRadio Frequency from Optical with Instabilities below $10^{-15}$- Generation and Measurement
This paper presents a frequency synthesis that achieves exceptional stability by transferring optical signals to the radio frequency (RF) domain at 100 MHz. We describe and characterize two synthesis chains composed of a cryogenic silicon cavity-stabilized laser at 1542 nm and an ultra-low expansion (ULE) glass cavity at 1157 nm, both converted to 10 GHz signals via Ti:Sapphire and Er/Yb:glass optical frequency combs (OFCs). The 10 GHz microwave outputs are further divided down to 100 MHz using a commercial microwave prescaler, which exhibits a residual frequency instability of $σ_y(1~\text{s})<10^{-15}$ and low $10^{-18}$ level at a few thousand seconds. Measurements are performed using a newly developed custom ultra-low-noise digital measurement system and are compared to the carrier-suppression technique. The new system enables high-sensitivity evaluation across the entire synthesis chain, from the optical and microwave heterodynes as well as the direct RF signals. Results show an absolute instability of $σ_y(1~\text{s})~\approx~4.7\times10^{-16}$ at 100 MHz. This represents the first demonstration of such low instability at 100 MHz, corresponding to a phase noise of -140 dBc/Hz at a 1 Hz offset and significantly surpassing earlier systems. These advancements open new opportunities for precision metrology and timing systems. - Top Cited Papers
- 14 January 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (2) , 646-649
Deployment of a transportable Yb optical lattice clock
We report on the first deployment of a ytterbium (Yb) transportable optical lattice clock (TOLC), commercially shipping the clock 3000 km from Boulder, Colorado, to Washington DC. The system, composed of a rigidly mounted optical reference cavity, an atomic physics package, and an optical frequency comb, fully realizes an independent frequency standard for comparisons in the optical and microwave domains. The shipped Yb TOLC was fully operational within 2 days of arrival, enabling frequency comparison with a rubidium (Rb) fountain at the United States Naval Observatory (USNO). To the best of our knowledge, this represents the first deployment of a fully independent TOLC, including the frequency comb, coherently uniting the optical stability of the Yb TOLC to the microwave output of the Rb fountain.
- 14 January 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (2) , 646-649
Top Cited PapersDeployment of a transportable Yb optical lattice clock
We report on the first deployment of a ytterbium (Yb) transportable optical lattice clock (TOLC), commercially shipping the clock 3000 km from Boulder, Colorado, to Washington DC. The system, composed of a rigidly mounted optical reference cavity, an atomic physics package, and an optical frequency comb, fully realizes an independent frequency standard for comparisons in the optical and microwave domains. The shipped Yb TOLC was fully operational within 2 days of arrival, enabling frequency comparison with a rubidium (Rb) fountain at the United States Naval Observatory (USNO). To the best of our knowledge, this represents the first deployment of a fully independent TOLC, including the frequency comb, coherently uniting the optical stability of the Yb TOLC to the microwave output of the Rb fountain.
- Open Access
- 28 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 4, 160-170
Direct Digital Simultaneous Phase-Amplitude Noise and Allan Deviation Measurement System
In this paper, we present a direct digital measurement system capable of simultaneously measuring phase noise, amplitude noise, and Allan deviation with and without cross-correlation. The residual phase noise of the single-channel system achieves L (1 Hz) = −143 dBc/Hz for a 10 MHz input signal and an Allan deviation noise floor of 3.2 × 10 −15 at 1 second averaging time (τ). The system’s performance improves as expected with cross-correlation, resulting in an average-limited residual white noise floor of −185 dBc/Hz after only a few minutes of averaging, an improvement of 30 dB compared to a single-channel system. It also reaches an average limited flicker phase noise floor of L (1 Hz) = −160 dBc/Hz within two days, with an Allan deviation of 5 × 10 −16 @ τ = 1 second. To our knowledge, this represents the lowest noise performance ever reported for a digital measurement system. Our solution is based on a pair of high-performance analog-to-digital converters and a single system-on-achip (SoC) with multiple processors and a field programmable gate array (FPGA). The architecture allows for processing all data samples in real-time without dead-time between calculation frames, enabling the fastest averaging possible during cross-correlation.
- 28 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 4, 160-170
Open AccessDirect Digital Simultaneous Phase-Amplitude Noise and Allan Deviation Measurement System
In this paper, we present a direct digital measurement system capable of simultaneously measuring phase noise, amplitude noise, and Allan deviation with and without cross-correlation. The residual phase noise of the single-channel system achieves L (1 Hz) = −143 dBc/Hz for a 10 MHz input signal and an Allan deviation noise floor of 3.2 × 10 −15 at 1 second averaging time (τ). The system’s performance improves as expected with cross-correlation, resulting in an average-limited residual white noise floor of −185 dBc/Hz after only a few minutes of averaging, an improvement of 30 dB compared to a single-channel system. It also reaches an average limited flicker phase noise floor of L (1 Hz) = −160 dBc/Hz within two days, with an Allan deviation of 5 × 10 −16 @ τ = 1 second. To our knowledge, this represents the lowest noise performance ever reported for a digital measurement system. Our solution is based on a pair of high-performance analog-to-digital converters and a single system-on-achip (SoC) with multiple processors and a field programmable gate array (FPGA). The architecture allows for processing all data samples in real-time without dead-time between calculation frames, enabling the fastest averaging possible during cross-correlation.
- 25 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
Ultra-Low Phase Noise Frequency Division With Array of Direct Digital Synthesizers
In this article, we present a four-channel direct digital synthesis (DDS) design that operates with a common clock ranging from 500 MHz to 24 GHz and generates output frequencies up to 1.75 GHz. A key feature of this board is its custom field-programmable gate array (FPGA)-based synchronization method, which ensures alignment accuracy of 170 ps between the channels, enabling precise frequency and phase relationship settings. In addition, the DDS board incorporates a user-friendly web interface that allows for continuous control and monitoring capabilities over TCP/IP. Multiple synchronized channels can be power-combined to produce a low-phase noise output due to coherent addition of the common carriers and the noncoherent addition of the residual DDS noise. By exploiting these principles and combining eight parallel channels of two DDS boards, we achieve exceptional residual phase noise performance, with $\mathscr {L}(1 \text {Hz}) = -147 \text {dBc/Hz}$ and $\mathscr {L}(100 \text {kHz}) = -180 \text {dBc/Hz}$ for a 9.765625 MHz output signal. These noise levels surpass the previously reported results achieved with regenerative frequency dividers. We also present a method for obtaining accurate residual noise measurements using an absolute phase modulation (PM) noise and amplitude modulation (AM) noise analyzer. Furthermore, we analyze the phase alignment tolerances required to minimize the AM-to-PM and PM-to-AM conversion that commonly occurs in power-combined signals. Finally, we demonstrate the synthesis of a highly stable 9.765625 MHz signal obtained from a cavity-stabilized optical frequency comb (OFC), with an absolute white phase noise of ${-180} \text {dBc/Hz}$ .
- 25 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
Ultra-Low Phase Noise Frequency Division With Array of Direct Digital Synthesizers
In this article, we present a four-channel direct digital synthesis (DDS) design that operates with a common clock ranging from 500 MHz to 24 GHz and generates output frequencies up to 1.75 GHz. A key feature of this board is its custom field-programmable gate array (FPGA)-based synchronization method, which ensures alignment accuracy of 170 ps between the channels, enabling precise frequency and phase relationship settings. In addition, the DDS board incorporates a user-friendly web interface that allows for continuous control and monitoring capabilities over TCP/IP. Multiple synchronized channels can be power-combined to produce a low-phase noise output due to coherent addition of the common carriers and the noncoherent addition of the residual DDS noise. By exploiting these principles and combining eight parallel channels of two DDS boards, we achieve exceptional residual phase noise performance, with $\mathscr {L}(1 \text {Hz}) = -147 \text {dBc/Hz}$ and $\mathscr {L}(100 \text {kHz}) = -180 \text {dBc/Hz}$ for a 9.765625 MHz output signal. These noise levels surpass the previously reported results achieved with regenerative frequency dividers. We also present a method for obtaining accurate residual noise measurements using an absolute phase modulation (PM) noise and amplitude modulation (AM) noise analyzer. Furthermore, we analyze the phase alignment tolerances required to minimize the AM-to-PM and PM-to-AM conversion that commonly occurs in power-combined signals. Finally, we demonstrate the synthesis of a highly stable 9.765625 MHz signal obtained from a cavity-stabilized optical frequency comb (OFC), with an absolute white phase noise of ${-180} \text {dBc/Hz}$ .
- 12 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (2) , 332-339
Ultralow PM and AM Noise Generation With an Ensemble of Phase-Coherent Oscillators
This article investigates the performance of an array of multiple phase-coherent power-combined oscillators (PPOs) in terms of phase modulation (PM) noise and amplitude modulation (AM) noise. The array consists of six individual oscillator modules that generate three distinct frequencies: 10, 100 MHz, and 1 GHz. By meticulously aligning the phases, we observed a notable improvement of approximately 7.8 dB in the white frequency region for the power-combined signal’s AM and PM noise. This closely matches the theoretical value of ${{10}\log _{{10}}{(}{k}{)}}$ dB, where ${k}$ is the total number of oscillators. The enhancement arises from the fact that when multiple sources are combined, the power of each source adds coherently, while the random noise adds noncoherently. Our experiments resulted in single-sideband (SSB) white phase noise levels of −182, −191, and −168 dBc/Hz for 10, 100 MHz, and 1 GHz, respectively. The corresponding white AM noise levels are approximately −191, −194, and −182 dBc/Hz. Notably, these noise levels represent some of the lowest ever reported at these frequencies. However, the AM noise results for frequencies close to the carrier do not achieve the theoretical 7.8-dB improvement due to PM-to-AM conversion caused by imperfect phase alignment of the individual summed signals. Furthermore, we discuss the use of carrier-suppressed noise measurement and propose a novel, straightforward technique for optimizing phase alignment to minimize PM-to-AM and AM-to-PM conversion in phase-coherent oscillator arrays.
- 12 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (2) , 332-339
Ultralow PM and AM Noise Generation With an Ensemble of Phase-Coherent Oscillators
This article investigates the performance of an array of multiple phase-coherent power-combined oscillators (PPOs) in terms of phase modulation (PM) noise and amplitude modulation (AM) noise. The array consists of six individual oscillator modules that generate three distinct frequencies: 10, 100 MHz, and 1 GHz. By meticulously aligning the phases, we observed a notable improvement of approximately 7.8 dB in the white frequency region for the power-combined signal’s AM and PM noise. This closely matches the theoretical value of ${{10}\log _{{10}}{(}{k}{)}}$ dB, where ${k}$ is the total number of oscillators. The enhancement arises from the fact that when multiple sources are combined, the power of each source adds coherently, while the random noise adds noncoherently. Our experiments resulted in single-sideband (SSB) white phase noise levels of −182, −191, and −168 dBc/Hz for 10, 100 MHz, and 1 GHz, respectively. The corresponding white AM noise levels are approximately −191, −194, and −182 dBc/Hz. Notably, these noise levels represent some of the lowest ever reported at these frequencies. However, the AM noise results for frequencies close to the carrier do not achieve the theoretical 7.8-dB improvement due to PM-to-AM conversion caused by imperfect phase alignment of the individual summed signals. Furthermore, we discuss the use of carrier-suppressed noise measurement and propose a novel, straightforward technique for optimizing phase alignment to minimize PM-to-AM and AM-to-PM conversion in phase-coherent oscillator arrays.
- 27 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-9
A Simple Optimization Method for Generating High-Purity Amplitude and Phase Modulation
We present a simple method for the adjustment of an in-phase (I) and quadrature-phase (Q) Armstrong-type modulator for use as a calibrator in precision noise metrology. The availability of relatively pure levels of both amplitude modulation (AM) and phase modulation (PM) can greatly simplify the optimal alignment and calibration of metrology equipment such as AM and PM noise measurement systems. The phase and amplitude imbalance of the components that constitute an IQ modulator results in an undesired combination of AM and PM. These impairments must be corrected to generate the pure signals required for metrology. Our proposed method corrects for these non-ideal impairments without needing a calibrated IQ demodulator and offers a high-purity AM/PM signal with spurious modulations as low as 1 ppm. We present the calibration procedure and uncertainty analysis of such a modulator when used as a calibrator for a PM and AM noise measurement system.
- 27 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-9
A Simple Optimization Method for Generating High-Purity Amplitude and Phase Modulation
We present a simple method for the adjustment of an in-phase (I) and quadrature-phase (Q) Armstrong-type modulator for use as a calibrator in precision noise metrology. The availability of relatively pure levels of both amplitude modulation (AM) and phase modulation (PM) can greatly simplify the optimal alignment and calibration of metrology equipment such as AM and PM noise measurement systems. The phase and amplitude imbalance of the components that constitute an IQ modulator results in an undesired combination of AM and PM. These impairments must be corrected to generate the pure signals required for metrology. Our proposed method corrects for these non-ideal impairments without needing a calibrated IQ demodulator and offers a high-purity AM/PM signal with spurious modulations as low as 1 ppm. We present the calibration procedure and uncertainty analysis of such a modulator when used as a calibrator for a PM and AM noise measurement system.
- 7 March 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12016, 1201604-14
Precision optical and microwave synthesis of atomic clock frequencies with optical frequency combs
Low noise microwave signals, generated by coherent division from optical atomic clock signals with an optical frequency comb, are amongst the lowest noise and highest stability of both room temperature and cryogenic electronic sources. The latter conversion is necessary for the realization of timescales, and redefinition of the SI second, from next generation atomic clocks. To this end, I will describe a highly robust technique that uses feedforward to suppress noise in optical-to-microwave division. This technique also supports the simultaneous conversion of multiple independent optical signals to microwave signals with a single comb, permitting the independent synthesis of microwave signals from multiple atomic clocks with accuracy near 1 part in 10-18.
- 7 March 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12016, 1201604-14
Precision optical and microwave synthesis of atomic clock frequencies with optical frequency combs
Low noise microwave signals, generated by coherent division from optical atomic clock signals with an optical frequency comb, are amongst the lowest noise and highest stability of both room temperature and cryogenic electronic sources. The latter conversion is necessary for the realization of timescales, and redefinition of the SI second, from next generation atomic clocks. To this end, I will describe a highly robust technique that uses feedforward to suppress noise in optical-to-microwave division. This technique also supports the simultaneous conversion of multiple independent optical signals to microwave signals with a single comb, permitting the independent synthesis of microwave signals from multiple atomic clocks with accuracy near 1 part in 10-18.
- Open Access
- 1 February 2022
- Published by AIP Publishing in APL Photonics
- Vol. 7 (2)
10 GHz generation with ultra-low phase noise via the transfer oscillator technique
Coherent frequency division of high-stability optical sources permits the extraction of microwave signals with ultra-high spectral purity, enabling their application to systems that demand high timing precision. To date, the highest performance systems have required tight phase stabilization of laboratory grade optical frequency combs to Fabry-Perot optical reference cavities for faithful optical-to-microwave frequency division. This requirement limits the technology to highly-controlled laboratory environments. Here, we employ a transfer oscillator technique, which employs digital and RF analog electronics to coherently suppress additive optical frequency comb noise. This removes the stabilization requirement and allows for the extraction of multiple independent microwave outputs from a single comb, while at the same time, permitting low-noise microwave generation from combs with higher noise profiles. Using this method we transferred the phase stability of two high-Finesse optical sources at 1157 nm and 1070 nm to two independent 10 GHz signals using a single frequency comb. We demonstrated absolute phase noise below -106 dBc/Hz at 1-Hz from carrier with corresponding 1 second fractional frequency instability below 2x10-15. Finally, the latter phase noise levels were attainable for comb linewidths broadened up to 2 MHz, demonstrating the potential for out-of-lab use with low SWaP lasers.
- 1 February 2022
- Published by AIP Publishing in APL Photonics
- Vol. 7 (2)
Open Access10 GHz generation with ultra-low phase noise via the transfer oscillator technique
Coherent frequency division of high-stability optical sources permits the extraction of microwave signals with ultra-high spectral purity, enabling their application to systems that demand high timing precision. To date, the highest performance systems have required tight phase stabilization of laboratory grade optical frequency combs to Fabry-Perot optical reference cavities for faithful optical-to-microwave frequency division. This requirement limits the technology to highly-controlled laboratory environments. Here, we employ a transfer oscillator technique, which employs digital and RF analog electronics to coherently suppress additive optical frequency comb noise. This removes the stabilization requirement and allows for the extraction of multiple independent microwave outputs from a single comb, while at the same time, permitting low-noise microwave generation from combs with higher noise profiles. Using this method we transferred the phase stability of two high-Finesse optical sources at 1157 nm and 1070 nm to two independent 10 GHz signals using a single frequency comb. We demonstrated absolute phase noise below -106 dBc/Hz at 1-Hz from carrier with corresponding 1 second fractional frequency instability below 2x10-15. Finally, the latter phase noise levels were attainable for comb linewidths broadened up to 2 MHz, demonstrating the potential for out-of-lab use with low SWaP lasers.