Jaeyeon Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jaeyeon Park has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Shenghui Cui
Department of Electrical and Computer Engineering and SNU Electric Power Research Institute, Seoul National University, Seoul, South Korea
7 shared publications - Dong-Joon Kim
Department of Electrical and Computer Engineering and SNU Electric Power Research Institute, Seoul National University, Seoul, South Korea
5 shared publications - Jae-Jung Jung
School of Electronic and Electrical Engineering, Kyungpook National University, Daegu, Republic of Korea
3 shared publications - Jisun Ham
Department of Electrical and Computer Engineering and SNU Electric Power Research Institute, Seoul National University, Seoul, South Korea
2 shared publications - Junyeol Maeng
Department of Electrical and Computer Engineering and SNU Electric Power Research Institute, Seoul National University, Seoul, South Korea
2 shared publications - Seung-Ki Sul
Seoul National University, Seoul, South Korea
2 shared publications
Latest Publications
- 16 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (9) , 16503-16521
Improved Decoupled Control of Modular Multilevel Converter Under Constraint of Nearest Level Modulation via Disturbance Observer Design
Nearest level modulation is widely used in modular multilevel converters (MMCs) for its simplicity, but it introduces significant quantization effects on arm-voltage synthesis when the number of submodules (SMs) is small, as in medium-voltage applications. Although the indirect modulation method enables fully decoupled control of ac-side current, dc-side current, and SM capacitor energy, its performance relies on accurate arm voltage synthesis, making it incompatible with the large quantization errors induced by NLM. To address this challenge, this paper proposes a disturbance observer (DOB)-based compensation scheme, which is integrated into the indirect modulation framework. The proposed method compensates for the arm voltage synthesis error as a disturbance, thereby restoring the decoupled control performance of the indirect-modulated MMC without modifying the NLM and decoupled control structure, which is easy to implement. The validity and effectiveness of the proposed method in improving current quality and decoupled control performance are verified through both simulation and experimental results.
- 16 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (9) , 16503-16521
Improved Decoupled Control of Modular Multilevel Converter Under Constraint of Nearest Level Modulation via Disturbance Observer Design
Nearest level modulation is widely used in modular multilevel converters (MMCs) for its simplicity, but it introduces significant quantization effects on arm-voltage synthesis when the number of submodules (SMs) is small, as in medium-voltage applications. Although the indirect modulation method enables fully decoupled control of ac-side current, dc-side current, and SM capacitor energy, its performance relies on accurate arm voltage synthesis, making it incompatible with the large quantization errors induced by NLM. To address this challenge, this paper proposes a disturbance observer (DOB)-based compensation scheme, which is integrated into the indirect modulation framework. The proposed method compensates for the arm voltage synthesis error as a disturbance, thereby restoring the decoupled control performance of the indirect-modulated MMC without modifying the NLM and decoupled control structure, which is easy to implement. The validity and effectiveness of the proposed method in improving current quality and decoupled control performance are verified through both simulation and experimental results.
- 16 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (6) , 10324-10342
Fault-Tolerant Independent Pole Control Scheme of Zigzag MMC for Bipolar MVDC Distribution Systems
This article presents a fault-tolerant independent pole control scheme for a zigzag modular multilevel converter (MMC) targeting bipolar medium-voltage direct-current (MVDC) distribution systems. An MMC which adopts a zigzag transformer as an ac grid interface transformer, namely zigzag MMC, has inherent bipole operation capability with unbalanced loads of positive and negative poles on the dc side. Nevertheless, this topology has not been thoroughly investigated for its ability to maintain independent control of each pole in the case of a fault in the other. With a conventional MMC control which relies on normal operation of both poles, a fault in a single pole is likely to impact the overall operation of the converter. To tackle this problem, the proposed control scheme separates the arm current controllers and energy balancing controllers within upper and lower arms individually. Additional power reference coupling is introduced to indirectly inject circulating currents when both poles are healthy like the conventional MMC. When a single pole fault occurs, a seamless energy-balancing mode transition can be achieved by modifying inputs to current reference calculators. An ac-side single line-to-ground (SLG) fault ride through strategy can also be integrated without compromising the independence of both poles. A point-to-point zigzag-MMC based bipolar MVDC distribution system is tested by controller hardware-in-the-loop est setup. The test results under single pole-to-ground fault and ac SLG fault validate the effectiveness of the proposed control scheme. Moreover, experimental results using a downscaled MMC prototype and a zigzag transformer further demonstrate the performance of the proposed control scheme under abrupt single-pole blocking and ac SLG fault conditions.
- 16 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (6) , 10324-10342
Fault-Tolerant Independent Pole Control Scheme of Zigzag MMC for Bipolar MVDC Distribution Systems
This article presents a fault-tolerant independent pole control scheme for a zigzag modular multilevel converter (MMC) targeting bipolar medium-voltage direct-current (MVDC) distribution systems. An MMC which adopts a zigzag transformer as an ac grid interface transformer, namely zigzag MMC, has inherent bipole operation capability with unbalanced loads of positive and negative poles on the dc side. Nevertheless, this topology has not been thoroughly investigated for its ability to maintain independent control of each pole in the case of a fault in the other. With a conventional MMC control which relies on normal operation of both poles, a fault in a single pole is likely to impact the overall operation of the converter. To tackle this problem, the proposed control scheme separates the arm current controllers and energy balancing controllers within upper and lower arms individually. Additional power reference coupling is introduced to indirectly inject circulating currents when both poles are healthy like the conventional MMC. When a single pole fault occurs, a seamless energy-balancing mode transition can be achieved by modifying inputs to current reference calculators. An ac-side single line-to-ground (SLG) fault ride through strategy can also be integrated without compromising the independence of both poles. A point-to-point zigzag-MMC based bipolar MVDC distribution system is tested by controller hardware-in-the-loop est setup. The test results under single pole-to-ground fault and ac SLG fault validate the effectiveness of the proposed control scheme. Moreover, experimental results using a downscaled MMC prototype and a zigzag transformer further demonstrate the performance of the proposed control scheme under abrupt single-pole blocking and ac SLG fault conditions.
- 10 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (5) , 8409-8427
Partial Power-Hardware-in-the-Loop Test for In-Situ Dynamic and Steady-State Validation of a Single Submodule in a Megawatt-Scale MMC
Modular multilevel converter (MMC) has been highlighted as a scalable power converter for high-power applications. As a unit power block, submodule (SM) is a key component to achieve the scalability and reliability of the MMC. Therefore, it is important to test an SM under various operating conditions during the development stage before the final full assembly. To reduce the development cost and time, various methods have been presented to test a single SM without a full MMC assembly. Recently, owing to the advancement of processing power, real-time simulators are beginning to be incorporated to test an MMC controller as a controller-hardware-in-the-loop-simulation. This article proposes the realization of a versatile powering test scheme for a single SM combining a real-time simulator, referred to as partial power-hardware-in-the-loop (partial PHIL) test. For demonstration, an industrial SM for a 5 MW MMC-based motor drive system is tested using the partial PHIL test with full-scale voltage and current levels. Various operating conditions are considered, including initial boosting operation, magnetization of the induction motor at standstill, full-load operation, and a step change in speed reference.
- 10 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (5) , 8409-8427
Partial Power-Hardware-in-the-Loop Test for In-Situ Dynamic and Steady-State Validation of a Single Submodule in a Megawatt-Scale MMC
Modular multilevel converter (MMC) has been highlighted as a scalable power converter for high-power applications. As a unit power block, submodule (SM) is a key component to achieve the scalability and reliability of the MMC. Therefore, it is important to test an SM under various operating conditions during the development stage before the final full assembly. To reduce the development cost and time, various methods have been presented to test a single SM without a full MMC assembly. Recently, owing to the advancement of processing power, real-time simulators are beginning to be incorporated to test an MMC controller as a controller-hardware-in-the-loop-simulation. This article proposes the realization of a versatile powering test scheme for a single SM combining a real-time simulator, referred to as partial power-hardware-in-the-loop (partial PHIL) test. For demonstration, an industrial SM for a 5 MW MMC-based motor drive system is tested using the partial PHIL test with full-scale voltage and current levels. Various operating conditions are considered, including initial boosting operation, magnetization of the induction motor at standstill, full-load operation, and a step change in speed reference.
- Open Access
- 27 September 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 172
A supercapacitor size minimization and energy management strategy for E-STATCOM connected to weak grid
- 27 September 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 172
Open AccessA supercapacitor size minimization and energy management strategy for E-STATCOM connected to weak grid
- 10 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (7) , 1-11
Equivalent Circuit Extraction of MI-HTS Coil Including High-Frequency Region for Electromagnetic Transient Simulation With Voltage-Source Converter
Combining metal-insulation high-temperature superconductor (MI-HTS), power electronics presents a promising potential to implement reliable magnetic energy storage systems. A modern power converter, typically implemented as a voltage-source converter (VSC), utilizes power semiconductors with switching frequencies ranging from several kHz to hundreds of kHz. From a VSC design perspective, analyzing the current flowing into power semiconductors at the microsecond timescale is essential to prevent converter failure due to overcurrent. Thus, to reduce the risk of operation failure of VSC, it is crucial to simulate the operation of VSC with MI-HTS not only the long-term behavior but also the short-term dynamics before commissioning. This article presents a practical method to develop an equivalent circuit of MI-HTS, enabling the replication of its current response at the microsecond timescale within electromagnetic transient simulations. This circuit can be used to verify the operation of MI-HTS and VSC, including control algorithms, by considering characteristics of leakage currents in MI-HTS under pulsed voltage from the VSC. The proposed method utilizes measured frequency response data and a rational approximation algorithm to extract an equivalent circuit. The proposed procedure is validated through a comparison of simulated and experimental results from closed-loop current control of a 37.2 mH MI-HTS coil driven by a VSC with a switching frequency of 2 kHz.
- 10 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (7) , 1-11
Equivalent Circuit Extraction of MI-HTS Coil Including High-Frequency Region for Electromagnetic Transient Simulation With Voltage-Source Converter
Combining metal-insulation high-temperature superconductor (MI-HTS), power electronics presents a promising potential to implement reliable magnetic energy storage systems. A modern power converter, typically implemented as a voltage-source converter (VSC), utilizes power semiconductors with switching frequencies ranging from several kHz to hundreds of kHz. From a VSC design perspective, analyzing the current flowing into power semiconductors at the microsecond timescale is essential to prevent converter failure due to overcurrent. Thus, to reduce the risk of operation failure of VSC, it is crucial to simulate the operation of VSC with MI-HTS not only the long-term behavior but also the short-term dynamics before commissioning. This article presents a practical method to develop an equivalent circuit of MI-HTS, enabling the replication of its current response at the microsecond timescale within electromagnetic transient simulations. This circuit can be used to verify the operation of MI-HTS and VSC, including control algorithms, by considering characteristics of leakage currents in MI-HTS under pulsed voltage from the VSC. The proposed method utilizes measured frequency response data and a rational approximation algorithm to extract an equivalent circuit. The proposed procedure is validated through a comparison of simulated and experimental results from closed-loop current control of a 37.2 mH MI-HTS coil driven by a VSC with a switching frequency of 2 kHz.