Takayuki Matsunuma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Takayuki Matsunuma has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Norihiko Iki
National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
12 shared publications - Osamu Kurata
National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
9 shared publications Hiro Yoshida
7 shared publications- Takehiko Segawa
National Institute of Advanced Industrial Science and Technology (AIST)
7 shared publications Hiromi Takeuchi
6 shared publicationsKatsuhiko Kadoguchi
6 shared publications
Latest Publications
- 19 August 2025
- Published by Elsevier in Aerospace Science and Technology
- Vol. 168
Hybrid plasma actuators for reducing passage vortex and tip leakage vortex in a linear turbine blade cascade at various Reynolds numbers
- 19 August 2025
- Published by Elsevier in Aerospace Science and Technology
- Vol. 168
Hybrid plasma actuators for reducing passage vortex and tip leakage vortex in a linear turbine blade cascade at various Reynolds numbers
- Open Access
Effect of Plasma Actuator Layout on the Passage Vortex Reduction in a Linear Turbine Cascade for a Wide Range of Reynolds Numbers
This study examined how various plasma actuator (PA) configurations affect the passage vortex (PV) reduction in a linear turbine cascade (LTC) utilizing dielectric barrier discharge PAs. The experiments were carried out under three specific layout conditions: axial placement of the PA, slanted placement at the blade inlet, and slanted placement inside the blade. Particle image velocimetry was employed to measure the velocity distribution of the secondary flow at the LTC exit, followed by an analysis of the streamline patterns, turbulence intensity distribution, and vorticity distribution. At a Reynolds number of 3.7 × 104, the PA with an oblique orientation at the blade inlet provided the most effective PV suppression. The average value of the secondary flow velocity and the peak vorticity value at the LTC exit decreased by 59.0% and 68.8%, respectively, compared to the no-control case. Furthermore, the wind tunnel blower’s rotation speed was modified, adjustments were made to the LTC’s mainstream velocity, and the Reynolds number transitioned from 1.0 × 104 to 9.9 × 104, approximately 10 times. When the slanted PA was used at the blade inlet, the PV suppression effect was the highest. The peak vorticity value owing to the PV at the LTC exit decreased by 62.9% at the lowest Reynolds number of 1.0 × 104. The Reynolds number increased with a higher mainstream velocity and decreased flow induced by the PA, consequently reducing the PV suppression effect. However, the drive of the PA was effective even under the most severe conditions (9.9 × 104), and the peak vorticity value was reduced by 20.2%.
Open AccessEffect of Plasma Actuator Layout on the Passage Vortex Reduction in a Linear Turbine Cascade for a Wide Range of Reynolds Numbers
This study examined how various plasma actuator (PA) configurations affect the passage vortex (PV) reduction in a linear turbine cascade (LTC) utilizing dielectric barrier discharge PAs. The experiments were carried out under three specific layout conditions: axial placement of the PA, slanted placement at the blade inlet, and slanted placement inside the blade. Particle image velocimetry was employed to measure the velocity distribution of the secondary flow at the LTC exit, followed by an analysis of the streamline patterns, turbulence intensity distribution, and vorticity distribution. At a Reynolds number of 3.7 × 104, the PA with an oblique orientation at the blade inlet provided the most effective PV suppression. The average value of the secondary flow velocity and the peak vorticity value at the LTC exit decreased by 59.0% and 68.8%, respectively, compared to the no-control case. Furthermore, the wind tunnel blower’s rotation speed was modified, adjustments were made to the LTC’s mainstream velocity, and the Reynolds number transitioned from 1.0 × 104 to 9.9 × 104, approximately 10 times. When the slanted PA was used at the blade inlet, the PV suppression effect was the highest. The peak vorticity value owing to the PV at the LTC exit decreased by 62.9% at the lowest Reynolds number of 1.0 × 104. The Reynolds number increased with a higher mainstream velocity and decreased flow induced by the PA, consequently reducing the PV suppression effect. However, the drive of the PA was effective even under the most severe conditions (9.9 × 104), and the peak vorticity value was reduced by 20.2%.
- Open Access
Active Flow Control for Passage Vortex Reduction in a Linear Turbine Cascade with Various Tip Clearance Sizes Using a Dielectric Barrier Discharge Plasma Actuator
In an axial-flow turbine of a jet engine used for aircraft propulsion, the passage vortex (PV) and tip leakage vortex (TLV) generated inside the blade passage deteriorate the aerodynamic performance. In this study, a dielectric barrier discharge plasma actuator (PA) was installed in the upstream endwall of the turbine cascade to suppress the PV. The effects of the presence or absence of tip clearance and the change in the size of the tip clearance on the vortex structure at the exit of the turbine cascade were observed by recording the flow velocity distributions using particle image velocimetry. In the absence of tip clearance, only the PV existed and was completely suppressed by the PA. By contrast, in the presence of tip clearance, a TLV occurred in addition to the PV. When the input voltage to the PA was varied with various tip clearance sizes, the change in the flow fields where the PV and TLV interfered was clarified. With tip clearance, the PV was suppressed as the input voltage increased; however, the TLV increased considerably. At each tip clearance size, changes in the center positions of the PV and TLV were observed at varying input voltages of the PA. With increasing input voltages of the PA, the center position of the PV moved to the pressure surface side of the tip of the adjacent blade, and the center position of the TLV moved toward the middle of the flow passage. With a larger tip clearance, the amount of movement at the center positions of both the PV and TLV increased.
Open AccessActive Flow Control for Passage Vortex Reduction in a Linear Turbine Cascade with Various Tip Clearance Sizes Using a Dielectric Barrier Discharge Plasma Actuator
In an axial-flow turbine of a jet engine used for aircraft propulsion, the passage vortex (PV) and tip leakage vortex (TLV) generated inside the blade passage deteriorate the aerodynamic performance. In this study, a dielectric barrier discharge plasma actuator (PA) was installed in the upstream endwall of the turbine cascade to suppress the PV. The effects of the presence or absence of tip clearance and the change in the size of the tip clearance on the vortex structure at the exit of the turbine cascade were observed by recording the flow velocity distributions using particle image velocimetry. In the absence of tip clearance, only the PV existed and was completely suppressed by the PA. By contrast, in the presence of tip clearance, a TLV occurred in addition to the PV. When the input voltage to the PA was varied with various tip clearance sizes, the change in the flow fields where the PV and TLV interfered was clarified. With tip clearance, the PV was suppressed as the input voltage increased; however, the TLV increased considerably. At each tip clearance size, changes in the center positions of the PV and TLV were observed at varying input voltages of the PA. With increasing input voltages of the PA, the center position of the PV moved to the pressure surface side of the tip of the adjacent blade, and the center position of the TLV moved toward the middle of the flow passage. With a larger tip clearance, the amount of movement at the center positions of both the PV and TLV increased.
- Open Access
- 24 February 2023
- Published by Elsevier in Aerospace Science and Technology
- Vol. 136
Vortex structure for reducing tip leakage flow of linear turbine cascade using dielectric barrier discharge plasma actuator
- 24 February 2023
- Published by Elsevier in Aerospace Science and Technology
- Vol. 136
Open AccessVortex structure for reducing tip leakage flow of linear turbine cascade using dielectric barrier discharge plasma actuator
- Open Access
Effects of Burst Ratio and Frequency on the Passage Vortex Reduction of a Linear Turbine Cascade Using a Dielectric Barrier Discharge Plasma Actuator
A dielectric barrier discharge plasma actuator was employed to reduce the passage vortex generated in a turbine cascade. This study focused on the burst mode drive of a plasma actuator and examined the relationship between flow field changes and the burst ratio and frequency. The non-dimensionalized burst frequency was fixed at F+ = 1.26, and the burst ratio was varied from 0.01 (1% operation) to 1 (100% operation, continuous mode). Generally, an increase in the burst ratio weakens the passage vortex, and the center of the passage vortex moves more toward the upper endwall surface and blade suction surface side. However, the velocity distribution, secondary flow streamlines, turbulence intensity distribution, and vorticity distribution did not change proportionally with changes in the burst ratio. Furthermore, the burst ratio was fixed at BR = 0.5, and the non-dimensional burst frequency varied from F+ = 0.013 to 62.9. Low burst frequencies led to a decrease in the peak velocity of the passage vortex, vorticity at the passage vortex center, and negative peak vorticity; however, an increase in the distance of the center of the passage vortex from the upper endwall surface and the turbulence intensity at the vortex center was observed. In contrast, high burst frequencies resulted in a decrease in the position of the vortex center and the turbulence intensity of the passage vortex center, while the peak velocity of the passage vortex, vorticity at the vortex center, and negative peak vorticity increased. The non-dimensionalized burst frequency around F+ = 1 is appropriate because both effects are balanced.
Open AccessEffects of Burst Ratio and Frequency on the Passage Vortex Reduction of a Linear Turbine Cascade Using a Dielectric Barrier Discharge Plasma Actuator
A dielectric barrier discharge plasma actuator was employed to reduce the passage vortex generated in a turbine cascade. This study focused on the burst mode drive of a plasma actuator and examined the relationship between flow field changes and the burst ratio and frequency. The non-dimensionalized burst frequency was fixed at F+ = 1.26, and the burst ratio was varied from 0.01 (1% operation) to 1 (100% operation, continuous mode). Generally, an increase in the burst ratio weakens the passage vortex, and the center of the passage vortex moves more toward the upper endwall surface and blade suction surface side. However, the velocity distribution, secondary flow streamlines, turbulence intensity distribution, and vorticity distribution did not change proportionally with changes in the burst ratio. Furthermore, the burst ratio was fixed at BR = 0.5, and the non-dimensional burst frequency varied from F+ = 0.013 to 62.9. Low burst frequencies led to a decrease in the peak velocity of the passage vortex, vorticity at the passage vortex center, and negative peak vorticity; however, an increase in the distance of the center of the passage vortex from the upper endwall surface and the turbulence intensity at the vortex center was observed. In contrast, high burst frequencies resulted in a decrease in the position of the vortex center and the turbulence intensity of the passage vortex center, while the peak velocity of the passage vortex, vorticity at the vortex center, and negative peak vorticity increased. The non-dimensionalized burst frequency around F+ = 1 is appropriate because both effects are balanced.
- Open Access
Effects of the Installation Location of a Dielectric Barrier Discharge Plasma Actuator on the Active Passage Vortex Control of a Turbine Cascade at Low Reynolds Numbers
Because axial flow turbines are widely used as the main components of jet engines and industrial gas turbines, their energy reduction effect is significant, even with a slight performance improvement. These turbines operate over a wide range of Reynolds numbers. However, at low Reynolds numbers below 1 × 105, the aerodynamic characteristics deteriorate greatly, due to the flow separation of the boundary layer on the blade suction surface and an increase in the secondary flow. In this study, an experiment to reduce the passage vortex was conducted using a dielectric barrier discharge plasma actuator, which is expected to operate with a new innovative active flow control technology. The plasma actuator was installed on the endwall of a linear turbine cascade in the test section of a wind tunnel. From the velocity distribution measured using particle image velocimetry, the secondary flow vector, turbulence intensity, and vorticity were analyzed. The input voltage and frequency of the plasma actuator were fixed at 12 kVp-p and 10 kHz, respectively. In particular, the optimum installation location of the plasma actuator was examined from upstream to mid-passage positions of the turbine cascade (normalized axial location of Z/Cax = −0.35 to 0.51). In addition, the effect of the Reynolds number was examined by varying it between Reout = 1.8 × 104 and 3.7 × 104. From the experimental results, it was found that the optimum location of the plasma actuator was immediately before the blade leading edge (Z/Cax = −0.20 to −0.06). This is because the inlet boundary layer can be accelerated near the blade leading edge, weakening the horseshoe vortex which initially causes the passage vortex. At a higher Reynolds number, the passage vortex suppression effect of the plasma actuator is weakened, because the flow induced by the plasma actuators becomes relatively weaker as the mainstream velocity increases with an increase in the Reynolds number.
Open AccessEffects of the Installation Location of a Dielectric Barrier Discharge Plasma Actuator on the Active Passage Vortex Control of a Turbine Cascade at Low Reynolds Numbers
Because axial flow turbines are widely used as the main components of jet engines and industrial gas turbines, their energy reduction effect is significant, even with a slight performance improvement. These turbines operate over a wide range of Reynolds numbers. However, at low Reynolds numbers below 1 × 105, the aerodynamic characteristics deteriorate greatly, due to the flow separation of the boundary layer on the blade suction surface and an increase in the secondary flow. In this study, an experiment to reduce the passage vortex was conducted using a dielectric barrier discharge plasma actuator, which is expected to operate with a new innovative active flow control technology. The plasma actuator was installed on the endwall of a linear turbine cascade in the test section of a wind tunnel. From the velocity distribution measured using particle image velocimetry, the secondary flow vector, turbulence intensity, and vorticity were analyzed. The input voltage and frequency of the plasma actuator were fixed at 12 kVp-p and 10 kHz, respectively. In particular, the optimum installation location of the plasma actuator was examined from upstream to mid-passage positions of the turbine cascade (normalized axial location of Z/Cax = −0.35 to 0.51). In addition, the effect of the Reynolds number was examined by varying it between Reout = 1.8 × 104 and 3.7 × 104. From the experimental results, it was found that the optimum location of the plasma actuator was immediately before the blade leading edge (Z/Cax = −0.20 to −0.06). This is because the inlet boundary layer can be accelerated near the blade leading edge, weakening the horseshoe vortex which initially causes the passage vortex. At a higher Reynolds number, the passage vortex suppression effect of the plasma actuator is weakened, because the flow induced by the plasma actuators becomes relatively weaker as the mainstream velocity increases with an increase in the Reynolds number.
- Open Access
Effects of Input Voltage and Freestream Velocity on Active Flow Control of Passage Vortex in a Linear Turbine Cascade Using Dielectric Barrier Discharge Plasma Actuator
Passage vortex exists as one of the typical secondary flows in turbomachines and generates a significant total pressure loss and degrades the aerodynamic performance. Herein, a dielectric barrier discharge (DBD) plasma actuator was utilized for an active flow control of the passage vortex in a linear turbine cascade. The plasma actuator was installed on the endwall, 10 mm upstream from the leading edge of the turbine cascade. The freestream velocity at the outlet of the linear turbine cascade was set to range from UFS,out = 2.4 m/s to 25.2 m/s, which corresponded to the Reynolds number ranging from Reout = 1.0 × 104 to 9.9 × 104. The two-dimensional velocity field at the outlet of the linear turbine cascade was experimentally analyzed by particle image velocimetry (PIV). At lower freestream velocity conditions, the passage vortex was almost negligible as a result of the plasma actuator operation (UPA,max/UFS,out = 1.17). Although the effect of the jet induced by the plasma actuator weakened as the freestream velocity increased, the magnitude of the peak vorticity was reduced under all freestream velocity conditions. Even at the highest freestream velocity condition of UFS,out = 25.2 m/s, the peak value of the vorticity was reduced approximately 17% by the plasma actuator operation at VAC = 15 kVp-p (UPA,max/UFS,out = 0.18).
Open AccessEffects of Input Voltage and Freestream Velocity on Active Flow Control of Passage Vortex in a Linear Turbine Cascade Using Dielectric Barrier Discharge Plasma Actuator
Passage vortex exists as one of the typical secondary flows in turbomachines and generates a significant total pressure loss and degrades the aerodynamic performance. Herein, a dielectric barrier discharge (DBD) plasma actuator was utilized for an active flow control of the passage vortex in a linear turbine cascade. The plasma actuator was installed on the endwall, 10 mm upstream from the leading edge of the turbine cascade. The freestream velocity at the outlet of the linear turbine cascade was set to range from UFS,out = 2.4 m/s to 25.2 m/s, which corresponded to the Reynolds number ranging from Reout = 1.0 × 104 to 9.9 × 104. The two-dimensional velocity field at the outlet of the linear turbine cascade was experimentally analyzed by particle image velocimetry (PIV). At lower freestream velocity conditions, the passage vortex was almost negligible as a result of the plasma actuator operation (UPA,max/UFS,out = 1.17). Although the effect of the jet induced by the plasma actuator weakened as the freestream velocity increased, the magnitude of the peak vorticity was reduced under all freestream velocity conditions. Even at the highest freestream velocity condition of UFS,out = 25.2 m/s, the peak value of the vorticity was reduced approximately 17% by the plasma actuator operation at VAC = 15 kVp-p (UPA,max/UFS,out = 0.18).
- 1 January 2019
- Published by Japan Society of Mechanical Engineers in Journal of Fluid Science and Technology
- Vol. 14  (2) , JFST0007
Effects of mainstream velocity and setting position on flow separation control of a curved wall using plasma actuators
- 1 January 2019
- Published by Japan Society of Mechanical Engineers in Journal of Fluid Science and Technology
- Vol. 14  (2) , JFST0007
Effects of mainstream velocity and setting position on flow separation control of a curved wall using plasma actuators
- 26 June 2017
- Published by ASME International
Success of Ammonia-Fired, Regenerator-Heated, Diffusion Combustion Gas Turbine Power Generation and Prospect of Low NOx Combustion With High Combustion Efficiency
To protect against global warming, a massive influx of renewable energy is expected. Although hydrogen is a renewable media, its storage and transportation in large quantity is difficult. Ammonia, however, is a hydrogen energy carrier and carbon-free fuel, and its storage and transportation technology is already established. Although ammonia combustion was studied in the 1960s in the USA, the development of an ammonia combustion gas turbine had been abandoned because combustion efficiency was unacceptably low. Since that time, in the combustion field, ammonia has been thought of as a fuel N additive in the study of NOx formation. Recent demand for hydrogen carrier revives the usage of ammonia combustion, but no one has attempted an actual design setup for ammonia combustion gas turbine power generation. The National Institute of Advanced Industrial Science and Technology (AIST) in Japan successfully performed ammonia-kerosene co-fired gas turbine power generation in 2014, and ammonia-fired gas turbine power generation in 2015. In the facilities, a regenerator-heated, diffusion-combustion micro-gas turbine is used, and its high combustor inlet temperature enables high thermal efficiency of ammonia combustion compared with that of methane combustion. Adoption of the regenerator increased combustor inlet temperature and enhanced flame stability in ammonia-air combustion. Although NOx emission from a gas turbine combustor is high, a Selective Catalytic Reduction (SCR) after gas turbine combustor reduces NOx emission to less than 10 ppm. This means that the ammonia combustion gas turbine design, abandoned in the 1960s for its unacceptably low combustion efficiency, has performed successfully with regenerator and SCR technology. However, the weakness of these facilities was that they required large-size SCR equipment in order to suppress a high concentration of NOx. Although NOx reduction in the combustion process is desirable, low NOx combustion technology is difficult because ammonia had been thought of as a source of fuel-NO. In the case of premixed ammonia-air flame, there exists a low emission window of NOx and NH3 in a certain equivalence ratio, but combustion intensity is very low because the laminar burning velocity of NH3-air is one-fifth that of CH4-air. This means that, when utilizing the window of premixed ammonia-air flame, scale-up of the combustion chamber or fuel additives for enhancement of flame stability is necessary. This study shows that the addition of H2 is effective for low NOx combustion with high combustion efficiency. In addition, H2 can be easily made from NH3 decomposition. The other option is diffusion combustion. Further research on low NOx combustion is needed.
- 26 June 2017
- Published by ASME International
Success of Ammonia-Fired, Regenerator-Heated, Diffusion Combustion Gas Turbine Power Generation and Prospect of Low NOx Combustion With High Combustion Efficiency
To protect against global warming, a massive influx of renewable energy is expected. Although hydrogen is a renewable media, its storage and transportation in large quantity is difficult. Ammonia, however, is a hydrogen energy carrier and carbon-free fuel, and its storage and transportation technology is already established. Although ammonia combustion was studied in the 1960s in the USA, the development of an ammonia combustion gas turbine had been abandoned because combustion efficiency was unacceptably low. Since that time, in the combustion field, ammonia has been thought of as a fuel N additive in the study of NOx formation. Recent demand for hydrogen carrier revives the usage of ammonia combustion, but no one has attempted an actual design setup for ammonia combustion gas turbine power generation. The National Institute of Advanced Industrial Science and Technology (AIST) in Japan successfully performed ammonia-kerosene co-fired gas turbine power generation in 2014, and ammonia-fired gas turbine power generation in 2015. In the facilities, a regenerator-heated, diffusion-combustion micro-gas turbine is used, and its high combustor inlet temperature enables high thermal efficiency of ammonia combustion compared with that of methane combustion. Adoption of the regenerator increased combustor inlet temperature and enhanced flame stability in ammonia-air combustion. Although NOx emission from a gas turbine combustor is high, a Selective Catalytic Reduction (SCR) after gas turbine combustor reduces NOx emission to less than 10 ppm. This means that the ammonia combustion gas turbine design, abandoned in the 1960s for its unacceptably low combustion efficiency, has performed successfully with regenerator and SCR technology. However, the weakness of these facilities was that they required large-size SCR equipment in order to suppress a high concentration of NOx. Although NOx reduction in the combustion process is desirable, low NOx combustion technology is difficult because ammonia had been thought of as a source of fuel-NO. In the case of premixed ammonia-air flame, there exists a low emission window of NOx and NH3 in a certain equivalence ratio, but combustion intensity is very low because the laminar burning velocity of NH3-air is one-fifth that of CH4-air. This means that, when utilizing the window of premixed ammonia-air flame, scale-up of the combustion chamber or fuel additives for enhancement of flame stability is necessary. This study shows that the addition of H2 is effective for low NOx combustion with high combustion efficiency. In addition, H2 can be easily made from NH3 decomposition. The other option is diffusion combustion. Further research on low NOx combustion is needed.
- 26 June 2017
- Published by ASME International
Operation and Flame Observation of Micro Gas Turbine Firing Ammonia
A demonstration test with the aim to show the potential of ammonia-fired power plant is planned using a micro gas turbine. 50kW class turbine system firing kerosene is selected as a base model. Over 40kW of power generation was achieved by firing ammonia gas only. Over 40kW of power generation was also achieved by firing mixture of ammonia and methane. However ammonia gas supply increases NOx in the exhaust gas dramatically. NOx concentration in the exhaust gas of gas turbine reached at over 600ppm. In the case of the gas turbine operation firing kerosene-ammonia with 31kW of power generation at 75,000rpm of rotating speed, the LHV (Lower Heating Value) ratio of ammonia to the total supplied fuel was changed from 0% to 100% in detail. NO emission increases rapidly to around 400ppm with ammonia at 7% of LHV ratio of ammonia. Then NO emission increases gradually to 600ppm with ammonia at 27% of LHV ratio of ammonia. NO emission has the peak around 60% of LHV ratio of ammonia. NO emission decreases below 500ppm at 100% of LHV ratio of ammonia. The gas turbine operation firing methane-ammonia with 31kW of power generation at 75,000rpm of rotating speed was also tried. NO emission increases rapidly to around 470ppm with ammonia at 7% of LHV ratio of ammonia. Then NO emission increases gradually to 600ppm with ammonia around 30% of LHV ratio of ammonia. NO emission has the peak at 65% of LHV ratio of ammonia. NO emission decreases below 500ppm at 100% of LHV ratio of ammonia. Since the ammonia flame in the prototype combustor seems to be inhomogeneous, ammonia combustion in the prototype combustor may have high NOx region and low NOx region. Therefore there is a possibility of low-NOx combustion. Flame observation was planned to know combustion state for improvement toward the low NOx combustor. Flame observation from the combustor exit was available by extending the combustor exit with the adaptor of the bent coaxial tubes and the quartz window. Swirling flames of ammonia, methane and methane-ammonia were observed near the center axis of the combustor. Flame observation at 39.1kW of power generation was succeeded. In the case of the flame observation, fuel consumption increased due to increase of the heat loss from the combustor. The emissions of NO and NH3 clearly depend on the combustion inlet temperature at 75,000rpm of rotating speed. The emissions of NO and NH3 in the case of the flame observation setting corresponds to the emission in the case of the normal setting at the condition that the power output is 11.2kW lower.
- 26 June 2017
- Published by ASME International
Operation and Flame Observation of Micro Gas Turbine Firing Ammonia
A demonstration test with the aim to show the potential of ammonia-fired power plant is planned using a micro gas turbine. 50kW class turbine system firing kerosene is selected as a base model. Over 40kW of power generation was achieved by firing ammonia gas only. Over 40kW of power generation was also achieved by firing mixture of ammonia and methane. However ammonia gas supply increases NOx in the exhaust gas dramatically. NOx concentration in the exhaust gas of gas turbine reached at over 600ppm. In the case of the gas turbine operation firing kerosene-ammonia with 31kW of power generation at 75,000rpm of rotating speed, the LHV (Lower Heating Value) ratio of ammonia to the total supplied fuel was changed from 0% to 100% in detail. NO emission increases rapidly to around 400ppm with ammonia at 7% of LHV ratio of ammonia. Then NO emission increases gradually to 600ppm with ammonia at 27% of LHV ratio of ammonia. NO emission has the peak around 60% of LHV ratio of ammonia. NO emission decreases below 500ppm at 100% of LHV ratio of ammonia. The gas turbine operation firing methane-ammonia with 31kW of power generation at 75,000rpm of rotating speed was also tried. NO emission increases rapidly to around 470ppm with ammonia at 7% of LHV ratio of ammonia. Then NO emission increases gradually to 600ppm with ammonia around 30% of LHV ratio of ammonia. NO emission has the peak at 65% of LHV ratio of ammonia. NO emission decreases below 500ppm at 100% of LHV ratio of ammonia. Since the ammonia flame in the prototype combustor seems to be inhomogeneous, ammonia combustion in the prototype combustor may have high NOx region and low NOx region. Therefore there is a possibility of low-NOx combustion. Flame observation was planned to know combustion state for improvement toward the low NOx combustor. Flame observation from the combustor exit was available by extending the combustor exit with the adaptor of the bent coaxial tubes and the quartz window. Swirling flames of ammonia, methane and methane-ammonia were observed near the center axis of the combustor. Flame observation at 39.1kW of power generation was succeeded. In the case of the flame observation, fuel consumption increased due to increase of the heat loss from the combustor. The emissions of NO and NH3 clearly depend on the combustion inlet temperature at 75,000rpm of rotating speed. The emissions of NO and NH3 in the case of the flame observation setting corresponds to the emission in the case of the normal setting at the condition that the power output is 11.2kW lower.