TLTzung-Lin Lee

Tzung-Lin Lee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tzung-Lin Lee has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Novel Discontinuous PWM Method With Hybrid Three-Step Commutation to Reduce Common-Mode Voltage for Direct Matrix Converter

    by Sahel Solemanifard, Cheng-Chin Hu, Tzung-Lin Lee, Mohammadreza Lak

    The conventional discontinuous pulsewidth modulation (PWM) can provide several advantages in a direct matrix converter (DMC), such as less switching number and less execution time for modulation signals' calculation. However, it suffers from high common-mode voltage (CMV), which may cause damage to the DMC-based system. This article proposes a novel discontinuous PWM (DPWM) method to not only mitigate CMV but also further improve the conversion efficiency. In this method, the switching sequence is obtained in a new way using two medium and two small input line voltages, increasing the conversion efficiency. Besides, the proposed DPWM employs a rotating vector instead of a zero vector, which causes the CMV to reduce by 50% compared with the conventional DPWM. Notably, the proposed DPWM provides the above advantages while maintaining low total harmonic distortion (THD). Simulations and experiments have been conducted to verify the proposed DPWM method's effectiveness. The results of these tests support the claims made in the paper regarding the reduction of CMV, improved efficiency, and low THD.


  • A Modulation Method with Low Distortion for Isolated Three-phase AC-DC Matrix Converters

    by Tzu-Yen Hsu, Jun-Tong Kuo, Bo-Yi Li, Mohammadreza Lak, Tzung-Lin Lee

    This paper proposes a carrier-based symmetric eight-segment pulse width modulation (8SPWM) for the isolated three-phase AC-DC matrix converter to improve the quality of the three-phase input current. Moreover, it proposes a multi-step hybrid commutation strategy with improved transient response to avoid the short-circuit at the input terminal and the open-circuit at the output terminal caused by the bidirectional switch during commutation. The experimental results validate the effectiveness of the proposed modulation method and commutation strategy.

  • Implementation and Applications of Grid-Forming Inverter with SiC for Power Grid Conditioning

    by Tsorng-Juu Liang, Jiann-Fuh Chen, Le-Ren Chang-Chien, Jia-You Lee, Tzung-Lin Lee, Cheng-Chien Kuo, Yu-Jen Liu, Chao-Tsung Ma, Wen-Chung Chen, Kai-Hui Chen, et al.

    Sustainable energy technologies have become promising solutions to global warming and climate change. Operation of the electric power grid has been dominated in the past by synchronous generation, wherein conventional sustainable energy inverters are designed simply to feed maximum real power into the grid. With the increasing penetration of renewable energy, it is undergoing a rapid shift toward the power generation of inverter-based resources (IBRs). As a result, transitioning to a power grid with more IBRs requires introducing advanced inverter technology that can respond to various disturbances in frequency and voltage occurring on the grid. The grid-forming (GFM) inverter equipped with an energy storage system featuring frequency and voltage support functionalities is vital for the stability of the micro power grid system. The GFM inverter also offers PV output smoothing, low voltage ride through, and low frequency ride through. In addition, the GFM inverter functions as a voltage source inverter to supply energy under off-grid state when the main grid is in fault conditions. A SiC-based 30 kVA GFM inverter is presented with a 3-phase 3-level neutral-point-clamped (NPC) topology for high-frequency operation to achieve high efficiency and power density. Designchallenges in gate driver design, PCB layout, and thermal consideration are addressed. The performances of the designated GFMinverter are measured and tested under on-grid and off-grid operations to verify the functionalities of the advanced inverter, as well.


  • Open Access

    A Novel Three-Step Commutation Method for Direct Matrix Converter Free From Inrush Current and Voltage Error

    by Sahel Solemanifard, Yan-Xing Chen, Mohammadreza Lak, Tzung-Lin Lee

    The direct matrix converter is a well-accepted topology for AC/AC converters. The commutation method should be considered in the direct matrix converter topology to avoid failures caused by the input short circuit and output open circuit during commutations. The conventional three-step commutation method of input voltage not only avoids the aforementioned failures but also removes errors between actual and command output voltage. However, it increases the number of hard switching and the flow of inrush current originating from the mismatch between the turn-on and turn-off delay time of switches. This paper proposes a new three-step commutation method that eliminates inrush current and reduces the number of hard switching. In this way, the conversion efficiency is improved, and circuit hazards caused by inrush current are over. Meanwhile, the proposed commutation method keeps the advantage of canceling the voltage error of conventional three-step commutation. Noteworthy that the proposed commutation method is introduced based on a novel fixed-slope direct duty ratio PWM simplifying the practical implementation. The performance and effectiveness of the proposed method have been verified by simulation and experimental results.


  • A Common-Mode Voltage Elimination Method With Active Neutral Point Voltage Balancing Control for Three-Level T-Type Inverter

    by Mohammadreza Lak, Bing-Rong Chuang, Tzung-Lin Lee

    Nowadays, the three-level T-type inverters (3LT2Is) are widely employed in applications with high-performance requirements. The 3LT2Is commonly suffer from neutral point voltage (NPV) unbalance and common-mode voltage (CMV) variation. The medium vector pulse width modulation (MVPWM), which generates the reference voltage using medium and V0[OOO] zero voltage vectors, eliminates the CMV variation in 3LT2Is. However, it cannot keep the NPV balance, negatively affecting power quality. This paper proposes a hybrid method to simultaneously eliminate CMV variation and guarantee the NPV balance without topological change or extra hardware. The proposed method uses MVPWM when NPV is balanced, eliminating CMV variation. If NPV goes unbalanced, it utilizes novel high/low triangle PWM (H/LPWM) and MVPWM in a hybrid manner to balance the NPV. The H/LPWM, similar to MVPWM, synthesizes voltage using medium and V0[OOO] voltage vectors to maintain the CMV elimination advantage during the NPV balancing process. However, the difference between H/LPWMs and MVPWM switching patterns adjusts the average neutral point current to balance the NPV. Noteworthy that the proposed method provides NPV balancing ability for the entire power factor range. As a result, it is usable for various applications of 3LT2I, such as photovoltaic inverters, motor drives, etc. The proposed method is carrier-based which reduces the execution time and simplifies the practical implementation. The simulation study and experimental evaluation have been accomplished, and their results demonstrate the effectiveness of the proposed method.


  • Open Access

    A Hybrid Method for Three-Level T-Type Inverters to Eliminate Neutral Point Voltage Ripple and Control DC-Link Capacitors’ Voltage for Separate MPPT

    by Mohammadreza Lak, Ting-Lien Wu, Tzung-Lin Lee

    Nowadays, photovoltaic (PV) systems based on centralized topology with a three-level T-type (3LT 2 ) inverter are used to decrease investment costs and increase conversion efficiency. In this topology, the split capacitors of the DC-link can individually connected to PV arrays. Accordingly, DC-link capacitors’ voltage should separately controlled to track PV arrays’ maximum power point (MPP) voltage. However, the asymmetric control of capacitors’ voltage causes line voltage to unbalance and output current to distort. In this paper, a hybrid method based on dipolar variable injection and zero-sequence voltage injection concepts is proposed to simultaneously control the DC-link capacitors’ voltage of the 3LT 2 inverter and eliminate their voltages ripple. In the presence of partial shading, the proposed method can control the capacitors’ voltage of the DC-link to realize the separate MPP tracking while ensuring the balance of line voltages. Furthermore, the proposed method eliminates the voltage ripple on DC-link capacitors, inherently caused by the 3LT 2 inverter, to improve the DC-link lifetime and the PV system reliability. The simulation studies and practical experiments have been performed, and their results prove the validity of the proposed method, whether the PF is unity or non-unity.


  • A Hybrid Method to Eliminate Leakage Current and Balance Neutral Point Voltage for Photovoltaic Three-Level T-Type Inverter

    by Mohammadreza Lak, Yue-Ting Tsai, Bing-Rong Chuang, Tzung-Lin Lee, Mohammad Hassan Moradi

    Nowadays, neutral point voltage (NPV) balancing control and leakage current (LC) reduction methods are considered to improve the reliability of transformerless three-level T-type (3LT 2 ) inverter. Medium vector pulse width modulation (MVPWM) method can control the inverter operation to eliminate the LC; however, is powerless to balance the NPV. Alternatively, discontinuous PWM (DPWM) methods can be implemented to balance the NPV. In this article, a hybrid method for transformerless 3LT 2 inverter is proposed to simultaneously minimize the LC and accomplish balancing control in case of NPV unbalancing. The proposed method applies MVPWM switching patterns to eliminate LC while the NPV is balanced. If the NPV becomes unbalanced, it applies specific switching patterns of the DPWM methods as alternative patterns to balance the NPV with minimal LC. Accordingly, the proposed method not only maintains the LC elimination advantage of the MVPWM method but also realizes the NPV balancing capability without any topology modification or adding electrical components. Noteworthy, even the NPV balancing is accomplished with minimal flow of the LC. The proposed method is carrier-based PWM, which shortens execution time and simplifies practical implementation. Experimental tests have been accomplished and results demonstrate the effectiveness of the proposed method on adding the NPV balancing capability with minimal LC to the MVPWM method.


  • Open Access

    Decentralized Control of PV Inverter to Mitigate Voltage Rise in Resistive Feeder

    by Tzung-Lin Lee, Shang-Hung Hu, Shih-Sian Yang

    Increasing installation of photovoltaic (PV) in the distribution power system has resulted in serious voltage rise, limiting grid-connectable power. This scenario becomes significant in the low-voltage resistive feeder. This paper proposes a decentralized control for distributed PV inverters to mitigate voltage rise. Instead of MPPT (maximum power point tracking) mode, the proposed PV inverter is able to curtail its real power and compensate the reactive power according to the impedance at the installation location. The drooped characteristics between the output power and the impedance are developed so that the PV inverters are able to cooperatively suppress voltage rise based on their local voltage measurement only. Therefore, PV inverters are allowed to supply more power to the utility within voltage limitation. Simulations are conducted to guarantee the proposed control on improvement of voltage rise considering different parameter of feeder. A lab-scaled prototype circuit is established to verify effectiveness in a resistive feeder.


  • An Adaptive Control of DPWM for Clamped-Three-Level Photovoltaic Inverters With Unbalanced Neutral-Point Voltage

    by Mohammad M. Hashempour, Meng-Ying Yang, Tzung-Lin Lee

    An adaptive control of DPWM implementable in clamped-three-level inverters with two strings of PV panels in cascaded connection is proposed in this paper. The proposed modulation is developed based on the so-called circuit-level decoupling concept. It is able to provide balance line voltage even under unbalanced dc links. The unequal dc voltages appeared due to asymmetric MPPTs are controlled by proper injection of zero-sequence voltage to the common mode voltage while the total dc voltage is regulated based on the voltage commands generated by the MPPT of each string. Thus, both PV strings are able to be operated based on their MPPTs while there is almost no low-order harmonic distortion at the inverter output current. Compared with the previous methods, the high capability of the proposed method is evaluated by simulation study and experimental tests.


  • Real-Time Supervisory Control for Power Quality Improvement of Multi-Area Microgrids

    by Mohammad M. Hashempour, Tzung-Lin Lee, Mehdi Savaghebi, Josep M. Guerrero

    In this paper, the power quality (PQ) improvement of multi-area microgrids (MAMGs) is addressed. To this aim, mitigation of voltage harmonics and unbalance is considered by using distributed generators (DGs) and active power filters (APFs) in a proper way. As a novel approach, the main goal of the proposed method is to pick out redundant APFs and/or significantly reduce of DGs and APFs compensation workload by making collaboration between areas toward integrated PQ improvement of the MAMG. To achieve the desired PQ indices of different areas, supervisory control is planned for proper utilization of available compensators in time. By supervisory control, harmonic propagation between areas and the system unbalance are dealt with and systemic PQ improvement of the MAMG is provided. To this aim, scheduling framework is used to track the PQ situation of each area. Evaluation of the proposed control is carried out by a comprehensive simulation study in MATLAB/Simulink.